Wissenschaftliche Artikel der BAM
Filtern
Dokumenttyp
- Zeitschriftenartikel (34)
- Sonstiges (6)
Schlagworte
- Affinity chromatography (6)
- ELISA (5)
- IgG (5)
- Biosensor (4)
- Fluorescence (4)
- HPLC (4)
- Immunoassay (4)
- Immunosensor (4)
- Lab-on-a-chip (4)
- Mass spectrometry (4)
- Nitrotyrosine (4)
- Protein A (4)
- Reference material (4)
- Reproducibility (4)
- Traceability (4)
- Allergy (3)
- Antibodies (3)
- Diagnostics (3)
- FPLC (3)
- Hybridoma (3)
- Immunocapture (3)
- Immunoglobulins (3)
- Monoclonal antibody (3)
- Nitration (3)
- Protein G (3)
- Quality Control (3)
- Tyrosine (3)
- Affinity Chromatography (2)
- Affinitätschromatographie (2)
- Air pollution (2)
- Antibody coating (2)
- Aromatic amino acid analysis (2)
- Biochip (2)
- Chromatography (2)
- Copper (2)
- Dityrosine (2)
- Documentation (2)
- HTS (2)
- Immunoaffinity extraction (2)
- Immunoprecipitation (2)
- MALDI (2)
- Magnetic resonance imaging (2)
- Metrology (2)
- Microarray (2)
- Monoclonal Antibodies (2)
- Monolithic column (2)
- Nanoparticles (2)
- Nickel (2)
- Nitrogen oxides (2)
- Open Science (2)
- Peptide (2)
- Peptide library (2)
- Phenylalanine (2)
- Protein nitration (2)
- Proximity-enhanced reaction (2)
- Purification (2)
- Quality control (2)
- Regeneration (2)
- Sapphire (2)
- Screening (2)
- Sequence coverage (2)
- Synthetic peptides (2)
- 150th anniversary (1)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 280 nm (1)
- 6xHis (1)
- AAA (1)
- AAAA (1)
- ABC (1)
- ABID (1)
- ATCUN (1)
- Aautomatisation (1)
- Acute myocardial infarction (1)
- Additive Fertigung (1)
- Additive Manufacturing (1)
- Affinity (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity extraction (1)
- Affinitätsextraktion (1)
- Agarose (1)
- Air filter samples (1)
- Air particulate matter (1)
- Airport (1)
- Alanine scan (1)
- Aluminum oxide (1)
- Amino acid analysis (1)
- Amplification (1)
- Analysis (1)
- Analytical sciences (1)
- Anthropocene (1)
- Antibody Purification (1)
- Antibody identification (1)
- Antibody-gated indicator delivery (1)
- Antikörper (1)
- Array (1)
- Atmospheric aerosol (1)
- Augenbohne (1)
- Automated Purification (1)
- Aviation (1)
- BAM (1)
- BCA test (1)
- Back-side integration (1)
- Bacterial lysates (1)
- Benchmarking study (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Bet v 1 (1)
- Betula pendula (1)
- Binder (1)
- Binding molecule (1)
- Bioanalysis (1)
- Biochemistry (1)
- Bioconjugation (1)
- Bioinformatics (1)
- Biomarker (1)
- Biosensing (1)
- Biosensors (1)
- Bioseparation (1)
- Biotechnology (1)
- Birch pollen allergen (1)
- Bombs (1)
- Border surveillance (1)
- Borosilicate Glass (1)
- Borosilicatglas (1)
- Borosilikatglas (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Byproducts (1)
- COVID-19 (1)
- Calibration (1)
- Cardiac troponin (1)
- Cardiovascular (1)
- Carrier (1)
- Carrier protein (1)
- Carrier-Material (1)
- Chelate (1)
- Chemical evolution (1)
- Chemical protein modification (1)
- Chemiluminescence (1)
- Chicken antibodies (1)
- Chirality (1)
- Citation (1)
- Citizen Science (1)
- Cleavage (1)
- Click chemistry (1)
- Clones (1)
- Cmos (1)
- Collection (1)
- Column holder (1)
- Combinatorial chemistry (1)
- Combinatorial peptide library (1)
- Combustion (1)
- Commercialization (1)
- Compartmentalization (1)
- Competitive Immunoassay (1)
- Compound-independent calibration (1)
- Concentration step (1)
- Confiscation (1)
- Conformation (1)
- Construction (1)
- Continuous Sensor (1)
- Contrast agent (1)
- Corona virus (1)
- Corundum (1)
- Crosslinker (1)
- Customs (1)
- Cytoplasm (1)
- DHAP (1)
- Damage-associated molecular patterns (DAMPs) (1)
- De novo peptide sequencing (1)
- Deep learning-based tools (1)
- Degradation (1)
- Dendrimer (1)
- Derivatization (1)
- Detection (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Diesel exhaust (1)
- Digital immunoassay (1)
- Dimerization (1)
- Dityrosine crosslinking (1)
- Docking (1)
- Down Stream Processing (1)
- Downstream Processing (1)
- Downstream processing (1)
- Druckstabilität (1)
- Drug search (1)
- Drug trafficking (1)
- EDTAD (1)
- Editorial (1)
- Elastin-specific contrast agent ESMA (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Emergency (1)
- Enantiomeric excess ee (1)
- Encapsulation (1)
- Enhancement (1)
- Environment (1)
- Environmental pollutants (1)
- Error correction (1)
- Escherichia coli (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- Evanescent wave (1)
- Exhaust (1)
- Experiment (1)
- Explosiven (1)
- Explosives detection (1)
- False Positives (1)
- Flow injection immunoassay (1)
- Fluorescence label (1)
- Folding chirality (1)
- Gadofosveset (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Gated materials (1)
- Gesteuerten Nanopartikeln (1)
- Github (1)
- Glasmonolith (1)
- Glass (1)
- Glass Support (1)
- Grass pollen (1)
- Hapten Immunoassay (1)
- Hay fever (1)
- Heart attack (1)
- Heavy chains (1)
- Herceptin (1)
- HexaHis-Tag (1)
- High pH (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-throughput (1)
- Highspeed (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Human Plasma (1)
- Hydrochloric acid (1)
- Hydrolysis (1)
- IMAC purification (1)
- Identity (1)
- IgE (1)
- IgG determination (1)
- IgY (1)
- Illicit drug (1)
- Immobilisierung (1)
- Immunglobulin (1)
- Immunglobuline (1)
- Immunoassays (1)
- Immunoglobulin E (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Impact (1)
- Impurites (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inflammation (1)
- Inhibition (1)
- Internal standard (1)
- International drug trade (1)
- Jahrestag (1)
- Kjeldahl (1)
- LC-UV absorbance (1)
- LIF (1)
- Lab on a chip (1)
- Lab-on-a-Chip (1)
- Label (1)
- Ladder sequencing (1)
- Laser-induced fluorescence (1)
- Lateral flow assay (1)
- Library (1)
- Life sciences (1)
- Light chain (1)
- Light chains (1)
- Limit of detection (1)
- Low-cost (1)
- Luminol (1)
- MALDI-TOF MS (1)
- MR Angiography (1)
- MST (1)
- Material sciences (1)
- Mesoporous particles (1)
- Metalloprotein (1)
- Method (1)
- Microfluidic mixing (1)
- Microfluidic system (1)
- Microfluidics (1)
- Micrometeorites (1)
- Miller and Urey (1)
- Miniaturization (1)
- Missing fragmentation sites (1)
- Mobile phase (1)
- Molecular-MRI (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Multiplex (1)
- Multiplexing (1)
- Murchison meteorite (1)
- NIST (1)
- NIST-mAb 8671 (1)
- Nanocarrier (1)
- Nanoparticle (1)
- Nanoscience (1)
- Narcotics (1)
- Neoallergen (1)
- Neoepitopes (1)
- Nickel chelate (1)
- Nonspecific binding (NSB) (1)
- Nucleocapsid (1)
- OBOC library (1)
- Oligomerization (1)
- On-chip screening (1)
- One-bead-one-compound library (1)
- Online biosensor (1)
- Online detection (1)
- Open science (1)
- Optical detection (1)
- Orbitrap (1)
- Oriented immobilization (1)
- Ozone (1)
- PIC technology (1)
- Pattern recognition receptor (1)
- Peer review (1)
- Peptide aptamers (1)
- Peptide binder (1)
- Peptide folding (1)
- Peptide mass fingerprinting (1)
- Peptides (1)
- Permethrin (1)
- Peroxidase (1)
- Pflanzenvirus (1)
- Pharmaceutical (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phl p 5 (1)
- Phleum pratense (1)
- Photonic biosensor (1)
- Plant virus (1)
- Plasma (1)
- Polishing (1)
- Pollen extract (1)
- Pollutant (1)
- Polyclonal Antibodies (1)
- Polyglycerol (1)
- Porous rock (1)
- Prebiotic chemistry (1)
- Preprocessing (1)
- Primordial soup (1)
- Protein (1)
- Protein Purification (1)
- Protein content (1)
- Protein degradation (1)
- Protein folding (1)
- Protein hydrolysis (1)
- Protein oligomerization (1)
- Protein oligomers (1)
- Protein quantification (1)
- Protein test (1)
- Proteinoid (1)
- Purity (1)
- Quality assurance (1)
- Quantitative protein analysis (1)
- RBD (1)
- Racemate (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Reference materials (1)
- References (1)
- Reinigung (1)
- Replication (1)
- Replication crisis (1)
- Reproducibility crisis (1)
- Resonance wavelength shift (1)
- Ring resonator (1)
- Robustness (1)
- SBA-15 (1)
- SBA-16 (1)
- SPR (1)
- Schlangenbohne (1)
- Scientific publication (1)
- Security (1)
- Segregation (1)
- Self-assembled monolayers (SAM) (1)
- Self-assembly (1)
- Sensor (1)
- Separation (1)
- Sequencing (1)
- Sequencing algorithm (1)
- Serum (1)
- Silanization (1)
- Single molecule (1)
- Sintered Material (1)
- Software (1)
- Solid support (1)
- Solid-phase extraction (SPE) (1)
- Special issue (1)
- Spike protein (1)
- Stabilization (1)
- Stationäre Phase (1)
- Surface derivatization (1)
- Surface plasmon resonance (1)
- Surrogate citations (1)
- TLR4 activation (1)
- Target (1)
- Terephthalic acid (1)
- Terrorism (1)
- Therapeutic Antibodies (1)
- Tholins (1)
- Titan-Halterung (1)
- Toll-like receptor 4 (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Trastuzumab (1)
- Trennung (1)
- Trust (1)
- Tryptic digest (1)
- Tryptophan (1)
- Type-I pyrethroids (1)
- Ultrasensitive (1)
- Upscaling (1)
- Validation (1)
- Vigna unguiculata (1)
- Visualization (1)
- Wipe test (1)
- Zenodo (1)
- biokompatibel (1)
- gesintert (1)
- self-replication (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (40) (entfernen)
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, EDS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids were used to introduce functional groups for further conjugations. The common crosslinker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter was oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower non-specific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). A binding capacity of 1.8 mg IgG per gram of corundum powder was achieved. The advantages of corundum include the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, convenient handling, and flexible application.
Current trends in materials and life sciences are flanked by the need to push detection limits to single molecules or single cells, enable the characterization of increasingly complex matrices or sophisticated nanostructures, speed up the time of analysis, reduce instrument complexity and costs, and improve the reliability of data. This requires suitable analytical tools such as spectroscopic, separation and imaging techniques, mass spectrometry, and hyphenated techniques as well as sensors and their adaptation to application-specific challenges in the environmental, food, consumer product, health sector, nanotechnology, and bioanalysis. Increasing concerns about health threatening known or emerging pollutants in drinking water, consumer products, and food and about the safety of nanomaterials led to a new awareness of the importance of analytical sciences. Another important driver in this direction is the increasing demand by legislation, particularly in view of the 17 sustainable development goals by the United Nations addressing clean energy, industry, and innovation, sustainable cities, clean water, and responsible consumption and production. In this respect, also the development of analytical methods that enable the characterization of material flows in production processes and support recycling concepts of precious raw materials becomes more and more relevant. In the future, this will provide the basis for greener production in the chemical industry utilizing recycled or sustainable starting materials.
This makes analytical chemistry an essential player in terms of the circular economy helping to increase the sustainability of production processes. In the life sciences sector, products based on proteins, such as therapeutic and diagnostic antibodies, increase in importance. These increasingly biotechnologically produced functional biomolecules pose a high level of complexity of matrix and structural features that can be met only by highly advanced methods for separation, characterization, and detection. In addition, metrological traceability and target definition are still significant challenges for the future, particularly in the life sciences.
However, innovative reference materials as required for the health and food sector and the characterization of advanced materials can only be developed when suitable analytical protocols are available. The so-called reproducibility crisis in sciences underlines the importance of improved measures of quality control for all kinds of measurements and material characterization. This calls for thorough method validation concepts, suitable reference materials, and regular interlaboratory comparisons of measurements as well as better training of scientists in analytical sciences.
The important contribution of analytical sciences to these developments is highlighted by a broad collection of research papers, trend articles, and critical reviews from these different application fields. Special emphasis is dedicated to often-overlooked quality assurance and reference materials.
MALDI-TOF-MS-Based Identification of Monoclonal Murine Anti-SARS-CoV-2 Antibodies within One Hour
(2022)
During the SARS-CoV-2 pandemic, many virus-binding monoclonal antibodies have been developed for clinical and diagnostic purposes. This underlines the importance of antibodies as universal bioanalytical reagents. However, little attention is given to the reproducibility crisis that scientific studies are still facing to date. In a recent study, not even half of all research antibodies mentioned in publications could be identified at all. This should spark more efforts in the search for practical solutions for the traceability of antibodies. For this purpose, we used 35 monoclonal antibodies against SARS-CoV-2 to demonstrate how sequence-independent antibody identification can be achieved by simple means applied to the protein. First, we examined the intact and light chain masses of the antibodies relative to the reference material NIST-mAb 8671. Already half of the antibodies could be identified based solely on these two parameters. In addition, we developed two complementary peptide mass fingerprinting methods with MALDI-TOF-MS that can be performed in 60 min and had a combined sequence coverage of over 80%. One method is based on the partial acidic hydrolysis of the protein by 5 mM of sulfuric acid at 99 degrees C. Furthermore, we established a fast way for a tryptic digest without an alkylation step. We were able to show that the distinction of clones is possible simply by a brief visual comparison of the mass spectra. In this work, two clones originating from the same immunization gave the same fingerprints. Later, a hybridoma sequencing confirmed the sequence identity of these sister clones. In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0. This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
Fast and accurate determination of the protein content of a sample is an important and non-trivial task of many biochemical, biomedical, food chemical, pharmaceutical, and environmental research activities. Different methods of total protein determination are used for a wide range of proteins with highly variable properties in complex matrices. These methods usually work reasonably well for proteins under controlled conditions, but the results for non-standard and complex samples are often questionable. Here, we compare new and well-established methods, including traditional amino acid analysis (AAA), aromatic amino acid analysis (AAAA) based on the amino acids phenylalanine and tyrosine, reversed-phase liquid chromatography of intact proteins with UV absorbance measurements at 220 and 280 nm (LC-220, LC-280), and colorimetric assays like Coomassie Blue G-250 dye-binding assay (Bradford) and bicinchoninic acid (BCA) assay. We investigated different samples, including proteins with challenging properties, chemical modifications, mixtures, and complex matrices like air particulate matter and pollen extracts. All methods yielded accurate and precise results for the protein and matrix used for calibration. AAA, AAAA with fluorescence detection, and the LC-220 method yielded robust results even under more challenging conditions (variable analytes and matrices). These methods turned out to be well-suited for reliable determination of the protein content in a wide range of samples, such as air particulate matter and pollen.
The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue for public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 7 ppt (23 pM) of cocaine with a response time of 90 s and a total assay time below 3 min. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement.
The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue in public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect ultra-small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 23 pM (7 ppt) of cocaine with a response time of 90 seconds and a total assay time below 3 minutes. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement.
The allergenic and inflammatory potential of proteins can be enhanced by chemical modification upon exposure to atmospheric or physiological oxidants. The molecular mechanisms and kinetics of such modifications, however, have not yet been fully resolved. We investigated the oligomerization and nitration of the grass pollen allergen Phl p 5 by ozone (O3), nitrogen dioxide (NO2), and peroxynitrite (ONOO–). Within several hours of exposure to atmospherically relevant concentration levels of O3 and NO2, up to 50% of Phl p 5 were converted into protein oligomers, likely by formation of dityrosine cross-links. Assuming that tyrosine residues are the preferential site of nitration, up to 10% of the 12 tyrosine residues per protein monomer were nitrated. For the reaction with peroxynitrite, the largest oligomer mass fractions (up to 50%) were found for equimolar concentrations of peroxynitrite over tyrosine residues. With excess peroxynitrite, the nitration degrees increased up to 40% whereas the oligomer mass fractions decreased to 20%. Our results suggest that protein oligomerization and nitration are competing processes, which is consistent with a two-step mechanism involving a reactive oxygen intermediate (ROI), as observed for other proteins. The modified proteins can promote pro-inflammatory cellular signaling that may contribute to chronic inflammation and allergies in response to air pollution.
Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial, we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules.
After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.
A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 minute. Due to the glass material's excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nanofiltration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run.
A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 min. Due to the glass material’s excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nano-filtration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run.