Wissenschaftliche Artikel der BAM
Filtern
Dokumenttyp
- Zeitschriftenartikel (325)
Sprache
- Englisch (325) (entfernen)
Referierte Publikation
- ja (325) (entfernen)
Schlagworte
- Fluorescence (50)
- Quantum yield (35)
- Sensor (23)
- Lifetime (21)
- Quality assurance (20)
- Dye (18)
- Photophysics (18)
- Nano (16)
- Synthesis (13)
- Magnetic resonance imaging (12)
- Photoluminescence (12)
- Cancer (11)
- Imaging (11)
- NIR (11)
- Lanthanide (10)
- Nanomaterial (10)
- Nanoparticle (10)
- Immunoassay (9)
- Method (9)
- Particle (9)
- Electrochemistry (8)
- ICP-MS (8)
- Mass spectrometry (8)
- Mechanism (8)
- Nanoparticles (8)
- Quantum dots (8)
- Reference material (8)
- Energy transfer (7)
- Molecularly imprinted polymers (7)
- Raman spectroscopy (7)
- Soil (7)
- Contrast agent (6)
- ELISA (6)
- Gadolinium (6)
- Luminescence (6)
- MRI (6)
- Mass Spectrometry (6)
- Mycotoxins (6)
- Optical probe (6)
- PH (6)
- Surface chemistry (6)
- Traceability (6)
- Upconversion nanoparticle (6)
- Affinity chromatography (5)
- Core-shell particles (5)
- Cr(III) (5)
- Flow cytometry (5)
- Laser ablation (5)
- Ligand (5)
- Microscopy (5)
- Multiplexing (5)
- Single particle (5)
- Aggregation (4)
- Analytical Chemistry (4)
- Brightness (4)
- Cement (4)
- Industry 4.0 (4)
- Interlaboratory comparison (4)
- LA-ICP-MS (4)
- LC-MS/MS (4)
- Lab-on-a-chip (4)
- Metabolomics (4)
- Nitrotyrosine (4)
- Polymer (4)
- Quantitative spectroscopy (4)
- Raman microspectroscopy (4)
- Reproducibility (4)
- SWIR (4)
- Signal enhancement (4)
- XPS (4)
- XRF (4)
- Air pollution (3)
- Allergy (3)
- BODIPY (3)
- Bead (3)
- Biosensing (3)
- Bisphenol A (3)
- Brain (3)
- Calibration (3)
- Coating (3)
- Complex (3)
- Copper (3)
- Corrosion (3)
- Crystal (3)
- DNA origami (3)
- Ergot alkaloids (3)
- Excitation power density (3)
- Extracellular matrix (3)
- Food (3)
- Food analysis (3)
- Gadofosveset (3)
- Gas chromatography (3)
- General Medicine (3)
- HRMS (3)
- High-resolution mass spectrometry (3)
- Human serum (3)
- Hydrolysis (3)
- Iron oxide (3)
- Isotope dilution (3)
- Isotope ratio (3)
- LIBS (3)
- MOF (3)
- Mass Spectroscopy (3)
- Mechanochemistry (3)
- Molecular imaging (3)
- Molecular imprinting (3)
- Monoclonal antibody (3)
- Mycotoxin (3)
- NMR (3)
- Nitration (3)
- Optical spectroscopy (3)
- PFAS (3)
- Pollution (3)
- Quantification (3)
- Reference materials (3)
- Screening (3)
- Sensitization (3)
- Spectroscopy (3)
- Switch (3)
- Transformation products (3)
- Tyrosine (3)
- Uncertainty (3)
- Upconversion (3)
- AAS (2)
- Absolute isotope ratio (2)
- Adsorption (2)
- Aggregation induced emission (2)
- Amorphous carbon (2)
- Amperometry (2)
- Antibiotics (2)
- Antibody (2)
- Antikörper (2)
- Aromatic amino acid analysis (2)
- Atherosclerosis (2)
- Bacteria (2)
- Barcoding (2)
- Bead-based assay (2)
- Biochemistry (2)
- Biocides (2)
- CONSENS (2)
- Certified reference material (2)
- Charge transfer (2)
- Chromatography (2)
- Comparability (2)
- Core−shell particles (2)
- Cuprorivaite (2)
- Cytotoxicity (2)
- Degradation (2)
- Delta scale (2)
- Derivatization (2)
- Diagnosis (2)
- Diagnostics (2)
- Dimerization (2)
- Dityrosine (2)
- Documentation (2)
- Egyptian blue (2)
- Electron microscopy (2)
- Emission spectroscopy (2)
- Endocrine disruptor (2)
- Endokrine Disruptoren (2)
- Enhancement (2)
- Environmental Chemistry (2)
- Fatty acid metabolism (2)
- Fertilizer (2)
- Ferumoxytol (2)
- Fluoride (2)
- General Earth and Planetary Sciences (2)
- Glyphosate (2)
- HPLC (2)
- HPLC-MS/MS (2)
- HTS (2)
- Health, Toxicology and Mutagenesis (2)
- Heart failure (2)
- Hybridoma (2)
- Hydrazinolysis (2)
- ICP-OES (2)
- Indium phosphide (2)
- Indoor air (2)
- Inflammation (2)
- Iron (2)
- Isotope (2)
- Isotope ratios (2)
- LIF (2)
- Label (2)
- Lanthanides (2)
- Lateral flow assay (2)
- Life sciences (2)
- Limit of detection (2)
- Lipidomic profile (2)
- Lithium (2)
- MALDI (2)
- MALDI-TOF MS (2)
- MC-ICP-MS (2)
- Magnetic beads (2)
- Measurement uncertainty (2)
- Mercury (2)
- Mesoporous materials (2)
- Metabolic stress (2)
- Method development (2)
- Metrology (2)
- Microbeads (2)
- Microfluidics (2)
- Modelling (2)
- Modular Production (2)
- Monolithic column (2)
- Nanomaterials (2)
- Nickel (2)
- Nitrogen oxides (2)
- Nontarget analysis (2)
- Open Science (2)
- Optical detection (2)
- Origami (2)
- Oxygen (2)
- Ozone (2)
- Passivation (2)
- Peptide (2)
- Peptide library (2)
- Phenylalanine (2)
- Phosphorylated peptides (2)
- Photodegradation (2)
- Probe (2)
- Process Analytical Technology (2)
- Production (2)
- Prostate cancer (2)
- Protein (2)
- Protein nitration (2)
- Quality Control (2)
- Quality control (2)
- Quantum dot (2)
- Raman (2)
- Real-time process monitoring (2)
- Sapphire (2)
- Self-assembly (2)
- Sensors (2)
- Sequence coverage (2)
- Sewage sludge (2)
- Shell (2)
- Sialic acid (2)
- Single molecule (2)
- Software (2)
- Solid state NMR (2)
- Sr isotopes (2)
- Standardization (2)
- Standards (2)
- Surface (2)
- Synthetic peptides (2)
- Sythesis (2)
- Test strips (2)
- Theory (2)
- Thermal desorption (2)
- Toxicity (2)
- Transformation product (2)
- Triple isotope fractionation (2)
- Triplet-triplet annihilation (2)
- Tumor (2)
- Tumor metabolism (2)
- Ultrafine particles (2)
- Upconversion nanoparticles (2)
- Validation (2)
- Water analysis (2)
- Yb(III) complex (2)
- ZIF (2)
- ZIF-8 (2)
- 1-indanol (1)
- 150th anniversary (1)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 280 nm (1)
- 6xHis (1)
- AAA (1)
- AAAA (1)
- ABC (1)
- ABID (1)
- AF4 (1)
- AIE (1)
- AIS (1)
- ATCUN (1)
- Aautomatisation (1)
- Absorption (1)
- Abwasser (1)
- Acoustic (1)
- Acoustic resonance (1)
- Acrylamide (1)
- Acute myocardial infarction (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Adulteration (1)
- Advanced Materials (1)
- Advanced material (1)
- Advanced materials (1)
- Advanced nanomaterials (1)
- Affinity (1)
- Affinity Chromatography (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity extraction (1)
- AgInS (1)
- Aggregates (1)
- Aggregation-induced emission (1)
- Aging (1)
- Agriculture (1)
- Air filter samples (1)
- Air particulate matter (1)
- Air sampling (1)
- Airport (1)
- AlCl (1)
- Alanine scan (1)
- Algorithms (1)
- Altenuene (1)
- Alternaria mycotoxins (1)
- Aluminum (1)
- Aluminum oxide (1)
- Alzheimer’s disease (1)
- Amino acid analysis (1)
- Amoxicillin (1)
- Amplification (1)
- Amyloid-beta (1)
- Analysis (1)
- Analytical methods (1)
- Analytical sciences (1)
- Aneurysm (1)
- Angiography (1)
- Angiotensin II (1)
- Anhydrite (1)
- Aniline (1)
- Animal slurry (1)
- Anion recognition (1)
- Antagonists (1)
- Anthropocene (1)
- Antibodies (1)
- Antibody Purification (1)
- Antibody identification (1)
- Antibody-gated indicator delivery (1)
- Antifouling surface (1)
- Antigens (1)
- Antimicrobial resistance (1)
- App (1)
- Application (1)
- Aqueous quantum dot (1)
- Aqueous synthesis (1)
- Arabidopsis (1)
- Argon (1)
- Array (1)
- Arsenite (1)
- Artificial Neural Networks (1)
- Artificial intelligence (1)
- Artificial neural networks (1)
- Artificial weathering (1)
- Ash content (1)
- Aspergillus (1)
- Assay (1)
- Atherosclerotic plaques (1)
- Atmospheric aerosol (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Atomic and molecular physics, and optics (1)
- Atomic force microscopy (1)
- Atomic weight (1)
- Augenbohne (1)
- Autoantibodies (1)
- Automated Purification (1)
- Automated image analysis (1)
- Automation (1)
- Autophagy (1)
- Aviation (1)
- Aza-BODIPY (1)
- BAM (1)
- BCA test (1)
- BODIPY dyes (1)
- BODIPY probe (1)
- BODIPYs (1)
- BPA removal (1)
- Back-side integration (1)
- Bacterial lipopolysaccharides (1)
- Bacterial lysates (1)
- Ball milling (1)
- Bassanite (1)
- Bead injections (1)
- Benchmarking study (1)
- Benchtop NMR (1)
- Benz[a]anthracene (BaA) (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Benzin (1)
- Benzo[a]pyrene (BaP) (1)
- Benzothiadiazole (1)
- Benzoxadiazole dyes (1)
- Beschichtung (1)
- Bet v 1 (1)
- Betula pendula (1)
- Binary gas mixture (1)
- Binder (1)
- Binding molecule (1)
- Bioanalysis (1)
- Biochip (1)
- Bioconjugation (1)
- Biodiesel (1)
- Biodiesel fuel (1)
- Biofilm (1)
- Bioinformatics (1)
- Biology (1)
- Biomarker (1)
- Biomarkers (1)
- Biomimicry (1)
- Biosensor (1)
- Biosensoren (1)
- Biosensors (1)
- Bioseparation (1)
- Biosilicification (1)
- Biosynthesis (1)
- Biotechnology (1)
- Biotests (1)
- Birch pollen allergen (1)
- Bismuth (1)
- Boden (1)
- Boltzmann plot (1)
- Bombs (1)
- Boron compound (1)
- Borosilicate Glass (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Building material (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Byproducts (1)
- C-C coupling (1)
- CE/MC-ICP-MS (1)
- CEA (1)
- CO2 + n-alkanes (1)
- COVID-19 (1)
- CRP (1)
- CUINS2 nanocrystals (1)
- CaCl emission bands (1)
- Cadmium (1)
- Calcite (1)
- Calcium (1)
- Calcium carbonate (1)
- Calcium carbonates (1)
- Calibrated fluorescence measurements (1)
- Calibration-free analysis (1)
- Cancer awareness measure (1)
- Cancer cells (1)
- Cancer risk (1)
- Canine olfactometry (1)
- Carbamazepine (1)
- Cardiac troponin (1)
- Cardiolipins (1)
- Cardiovascular (1)
- Carrier (1)
- Carrier protein (1)
- Carriers (1)
- Cconventional method (1)
- Cell proliferation (1)
- Cell studies (1)
- Cellular substructure (1)
- Cellulose (1)
- Cerium oxide (1)
- Charged dyes (1)
- Chelate (1)
- Chemical Process Control (1)
- Chemical Safety (1)
- Chemical evolution (1)
- Chemical protein modification (1)
- Chemiluminescence (1)
- Chemodosimeter (1)
- Chemometrics (1)
- Chicken antibodies (1)
- Chirality (1)
- Chlorides (1)
- Chlorine (1)
- Chlorine determination (1)
- Chloroanilines (1)
- Ciaaw.org (1)
- Citation (1)
- Citizen Science (1)
- Citrullinated (1)
- Classical primary measurement method (CPM) (1)
- Classification (1)
- Cleaning (1)
- Cleavage (1)
- Climate (1)
- Clinical Biochemistry (1)
- Cobaloxime complex (1)
- Cocoa (1)
- Collaborative trial (1)
- Collagen (1)
- Collection (1)
- Colloidal semiconductor nanocrystals (1)
- Color (1)
- Column holder (1)
- Combinatorial chemistry (1)
- Combinatorial peptide library (1)
- Combustion (1)
- Combustion Ion Chromatography (1)
- Combustion ion chromatography (CIC) (1)
- Commercial metal-organic frameworks (1)
- Commercialization (1)
- Compartmentalization (1)
- Complexation (1)
- Compound-independent calibration (1)
- Concentration step (1)
- Concrete (1)
- Conformation (1)
- Conjugate (1)
- Construction (1)
- Construction products (1)
- Consumer Products (1)
- Continuous Processes (1)
- Continuous Sensor (1)
- Continuous processes (1)
- Conventional isotope ratio (1)
- Converter material (1)
- Coordination polymer (1)
- Core-shell (1)
- Core–shell particles (1)
- Corona virus (1)
- Corophium volutator (1)
- Corundum (1)
- Cr(III) complex (1)
- Cross section (1)
- Cross-sectioning (1)
- Cryoadsorption (1)
- Cucurbituril (1)
- Cyber-Physical Systems (1)
- Cyber-physical system (1)
- Cyclic voltammetry (1)
- Cyclometalated iridium (III) complexes (1)
- Cytoplasm (1)
- DFA (1)
- DFT (1)
- DHAP (1)
- DNA (1)
- DNA radiation damage (1)
- DNA strand breaks (1)
- DPA (1)
- Damage-associated molecular patterns (DAMPs) (1)
- Data (1)
- Data Fusion (1)
- Data infrastructures (1)
- Data processing (1)
- De novo peptide sequencing (1)
- Deep learning-based tools (1)
- Degradation of refrigerants (1)
- Delta isotope standard (1)
- Delta value (1)
- Dendrimer (1)
- Density data (1)
- Design of experiment (1)
- Deterioration (1)
- Development (1)
- Diagnostic Antibodies (1)
- Diastolic dysfunction (1)
- Diatomic molecule (1)
- Diclofenac (1)
- Diesel exhaust (1)
- Diffusion (1)
- Digestion (1)
- Digital Transformation (1)
- Digital holographic cytometry (1)
- Digital immunoassay (1)
- Digital representations (1)
- Digital twins (1)
- Digital workflows (1)
- Dip-stick assay (1)
- Disinfection (1)
- Dissolution (1)
- Dityrosine crosslinking (1)
- Docking (1)
- Down Stream Processing (1)
- Downstream processing (1)
- Drug Discovery (1)
- Dual sensing (1)
- Dual-color labeling glycan (1)
- Dyad (1)
- Dye loading optimisation (1)
- Dye monomers (1)
- Dye release (1)
- Dyes (1)
- Dyes/pigments (1)
- Dynamic calibration gas mixtures (1)
- EC/MS (1)
- ECR (1)
- EDTAD (1)
- EP-3533 (1)
- ESMA (1)
- EXAFS (1)
- Early Earth (1)
- Ecotoxicity (1)
- Editorial (1)
- Elastin (1)
- Elastin-specific contrast agent ESMA (1)
- Elastin-specific molecular agent (1)
- Electrochemical (1)
- Electrochemical titration (1)
- Electron transfer (1)
- Elektrochemie (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Emergency (1)
- Emission testing (1)
- Enantiomeric excess ee (1)
- Encapsulation (1)
- Encoding (1)
- Endokriner Disruptor (1)
- Enhancement strategy (1)
- Environment (1)
- Environmental Engineering (1)
- Environmental pollutants (1)
- Environmental simulations (1)
- Environmental speciation (1)
- Enzyme (1)
- Enzyme-Linked Immunosorbent Assay (1)
- Equation of state (1)
- Error correction (1)
- Escherichia coli (1)
- Esterification (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- European Reference Material (1)
- Ex vivo (1)
- Excimers (1)
- Excitation (1)
- Exhaust (1)
- Exocytosis (1)
- Experiment (1)
- Explosives detection (1)
- Exposure (1)
- Extractable organically bound fluorine (EOF) (1)
- Extraction (1)
- FFF-3D printer (1)
- FFF-3D printing (1)
- FPLC (1)
- FRET (1)
- Feature selection (1)
- Fenton (1)
- Fenton’s reagent (1)
- Finow Canal (1)
- Flexible crystals (1)
- Flourescence (1)
- Flourescin (1)
- Flow injection immunoassay (1)
- Fluorescein (1)
- Fluorescence Polarization (1)
- Fluorescence label (1)
- Fluorescence life time (1)
- Fluorescence spectroscopy (1)
- Fluorescence standard (1)
- Fluorescent dyes (1)
- Fluorescent probes (1)
- Fluorescent sensors (1)
- Fluoreszenz (1)
- Fluorides (1)
- Fluorination (1)
- Fluoroacetic acid (1)
- Fluorophilic interactions (1)
- Folding chirality (1)
- Food fermentation (1)
- Food safety (1)
- Forsterite (1)
- Fourier transform spectroscopy (1)
- Fow injection analysis (1)
- Fragmentation pathway (1)
- Freisetzung (1)
- Fully aromatic frameworks (1)
- Functional group quantification (1)
- Functional monomers (1)
- Fungicide (1)
- Funtional Groups (1)
- Fusarium (1)
- Fusarium mycotoxin (1)
- GC/MS (1)
- GC/MS-MS (1)
- GF-MAS (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Galvanic anodes (1)
- Gamma-hydroxybutyric acid (1)
- Gas analysis (1)
- Gas chromatography (GC) (1)
- Gas sensing (1)
- Gasoline (1)
- Gated materials (1)
- Gd-DOTA (1)
- General Chemistry (1)
- Genotoxicity testing (1)
- Geological material (1)
- Ggadolinium (1)
- Github (1)
- Glass Support (1)
- Gold (1)
- Gold nanocluster (1)
- Gold nanoparticles (1)
- Graphene (1)
- Graphite furnace (1)
- Grass pollen (1)
- Green light excitation (1)
- Ground water (1)
- Groundwater (1)
- Group profile (1)
- Guanidinium receptors (1)
- Gypsum (1)
- HAXPES (1)
- HF free Digestion (1)
- HPLC-DAD/FLD (1)
- HR-CS-MAS (1)
- Hafnium (1)
- Hay fever (1)
- Heart attack (1)
- Heat accumulation (1)
- Heat flow (1)
- Heavy chains (1)
- Hemihydrate (1)
- Hepatocellular carcinoma (1)
- HexaHis-Tag (1)
- High entropy alloy (1)
- High pH (1)
- High pressure experiments (1)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-fired gypsum mortar (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- High-resolution continuum source molecular absorption spectrometry (1)
- High-throughput (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Hot-electrons (1)
- Human Plasma (1)
- Human leukocyte antigen (HLA) (1)
- Human papillomavirus (1)
- Human serum albumin (1)
- Hydrated silicate melts (1)
- Hydration (1)
- Hydrochloric acid (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrodynamic model (1)
- Hydrogen Storage (1)
- Hydrogen adsorption (1)
- Hydrogen adsorption storage (1)
- Hydrogen uptake reproducibility (1)
- Hydrogen-containing gas mixture (1)
- Hydrothermal fluid (1)
- Hydroxy warfarin (1)
- ICP-MS/MS (1)
- ICP-TOFMS (1)
- ICP-ToF-MS (1)
- ID-MS (1)
- ILC (1)
- IMAC purification (1)
- IR spectroscopy; conductometry (1)
- ISO REMCO (1)
- Identity (1)
- IgE (1)
- IgG (1)
- IgG determination (1)
- IgY (1)
- Image analysis (1)
- Image segmentation (1)
- Imaging Technique (1)
- Imidazole (1)
- Immunassay (1)
- Immunoaffinity extraction (1)
- Immunoassays (1)
- Immunocapture (1)
- Immunoglobulin E (1)
- Immunoglobulins (1)
- Immunohistochemistry (1)
- Immunology (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Impact (1)
- Imprinting (1)
- Impurites (1)
- In situ (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In vivo (1)
- In-house calibration solution (1)
- In-situ analysis (1)
- In-situ process monitoring (1)
- In-vivo (1)
- Indicator displacement assay (1)
- Indoor air quality (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inductively coupled plasma mass spectroscopy (1)
- Inductively‑coupled mass spectrometry (1)
- Industrial gypsum (1)
- Inert gases (1)
- Infrared thermography (1)
- Inhibition (1)
- Inline Analytics (1)
- Inorganic chemical analysis (1)
- Inorganic impurities (1)
- Instrumental isotope fractionation (1)
- Inter layer time (1)
- Interferometric spectroscopy (1)
- Intermixing (1)
- Internal standard (1)
- Ion mobility spectrometry (1)
- Ionophore (1)
- Ionophore antibiotics (1)
- Iposomes (1)
- Iridium (1)
- Isotope Dilution (1)
- Isotope Labelling (1)
- Isotope amount ratio (1)
- Isotope delta value (1)
- Isotope dilution (ID) (1)
- Isotope dilution mass spectrometry (1)
- Isotope reference material (1)
- Isotope-labeled (1)
- Isotopic analysis (1)
- Isotopic fractionation (1)
- Isotopologue Distribution (1)
- Iterative real-time optimization (1)
- Jahrestag (1)
- Job plot (1)
- Kjeldahl (1)
- Knowledge graphs (1)
- LA/ICP-MS Imaging (1)
- LC-UV absorbance (1)
- LC/HRMS (1)
- LC/MS-MS (1)
- LFIA (1)
- LSVEC (1)
- Lab-on-a-Chip (1)
- Laboratory 4.0 (1)
- Lacunary Keggin ion (1)
- Ladder sequencing (1)
- Lasalocid (1)
- Laser Ablation (1)
- Laser ablation-inductively coupled plasma-mass spectrometry (1)
- Laser ablation-inductively coupled plasma-mass spectroscopy (1)
- Laser induced breakdown Spectrocopy (LIBS) (1)
- Laser induced breakdown spectroscopy (1)
- Laser induced plasma (1)
- Laser induced plasma deposition (1)
- Laser powder bed fusion (1)
- Laser-induced breakdown spectroscopy (1)
- Laser-induced dielectric breakdown (LIDB) (1)
- Laser-induced fluorescence (1)
- Layer-by-Layer (1)
- Layers (1)
- Leaching (1)
- Lead (1)
- Legacy pollution (1)
- LiYF4 (1)
- Library (1)
- Life science (1)
- Lifetime encoding (1)
- Lifetime-encoded beads (1)
- Light chain (1)
- Light chains (1)
- Light harvesting (1)
- Lipidomics (1)
- Lipids (1)
- Liquid chromatography (1)
- Liquid chromatography (LC) (1)
- Liver X receptor (1)
- Lluminescence (1)
- Longst luminescence lifetime (1)
- Low-cost (1)
- Low-energy electrons (1)
- Luminescent lifetime (1)
- Luminol (1)
- Lymnaea stagnalis (1)
- Lysergic acid hydrazide (1)
- Lysosome (1)
- MALDI-TOF-MS (1)
- MC-TIMS (1)
- MIC (1)
- MICAP-MS (1)
- MLCT (1)
- MOF´s (1)
- MOSH/MOAH (1)
- MR Angiography (1)
- MR imaging (1)
- MST (1)
- MW-AES (1)
- MYCN (1)
- Machine learning (1)
- Macrophages (1)
- Magnesium (1)
- Magnesium carbonates (1)
- Magnetic (1)
- Magnetic nanocatalyst (1)
- Mass spectrometry (MS) (1)
- Mass-Spectrometry (1)
- Massenspektrometrie (1)
- Material sciences (1)
- Materials informatics (1)
- Mechanical properties (1)
- Medical diagnostics (1)
- Medicinal application (1)
- Medicine (1)
- Medium entropy alloy (1)
- MefHySto (1)
- Mercury speciation (1)
- Meso Portland cement (1)
- Mesofluidics (1)
- Mesoporous particles (1)
- Metabolic Flux (1)
- Metabolization (1)
- Metal cluster (1)
- Metal toxicity (1)
- Metal uptake (1)
- Metalloprotein (1)
- Metals (1)
- Metal−organic frameworks (1)
- Methanol oxidation (1)
- Methylanilines (1)
- Methylmercury (1)
- Metrology in chemistry (1)
- Microarray (1)
- Microbe interactions (1)
- Microfluidic (1)
- Microfluidic mixing (1)
- Microfluidic system (1)
- Micrometeorites (1)
- Microorganism (1)
- Microplastic-induced effects (1)
- Microplatic (1)
- Microscope slides (1)
- Microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) (1)
- Microwave-assisted synthesis (1)
- Mikrofluidik (1)
- Mikroplastik (1)
- Miller and Urey (1)
- Mineral identification (1)
- Mineral oil hydrocarobons (1)
- Mineral paragenesis (1)
- Miniaturization (1)
- Missing fragmentation sites (1)
- Mixed surface (1)
- Mixture toxicity (1)
- Mobile analytics (1)
- Mobile phase (1)
- Model Predictive Control (1)
- Modeling (1)
- Modified mycotoxins (1)
- Modifier adaptation (1)
- Molecular Biology (1)
- Molecular MRI (1)
- Molecular Organic Frameworks (1)
- Molecular marker (1)
- Molecular spectra (1)
- Molecular-MRI (1)
- Molecularly Imprinted Polymers (1)
- Molecule (1)
- Monensin (1)
- Monoclonal Antibodies (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Monomer (1)
- Monte Carlo algorithm (1)
- Mounting media (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multi-element analysis (1)
- Multi-prinicpal element alloys (MPEAs) (1)
- Multiple sclerosis (1)
- Multiple-injection sample-standard bracketing (1)
- Multiplex (1)
- Multiplexed assay (1)
- Multivariate (1)
- Multivariate data analysis (1)
- Multivariate methods (1)
- Murchison meteorite (1)
- NIR Spectroscopy (1)
- NIR dyes (1)
- NIR-I (1)
- NIR-II fluorescence (1)
- NIST (1)
- NIST-mAb 8671 (1)
- NMR Spectroscopy (1)
- NSE (1)
- Nanaoparticle (1)
- Nanaoparticles (1)
- Nano-carrier (1)
- Nanocarrier (1)
- Nanolenses (1)
- Nanomaterial design (1)
- Nanoparticle characterization (1)
- Nanoparticle dimers (1)
- Nanopartikel (1)
- Nanopowder (1)
- Nanosafety (Safe-by-design) (1)
- Nanoscience (1)
- Nanosciences (1)
- Nanostructures (1)
- Neoallergen (1)
- Neoepitopes (1)
- Neural networks (1)
- Neutral dyes (1)
- Nickel chelate (1)
- Nile Red (1)
- Nitrogen dioxide (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Nitrogen monoxide (1)
- Nitrogen plasma (1)
- Non-targeted analysis (1)
- Nonspecific binding (NSB) (1)
- Nuclear Magnetic Resonance Spectroscopy (1)
- Nuclear receptor (1)
- Nucleocapsid (1)
- OBOC library (1)
- Ochratoxin A (1)
- Oil spills (1)
- Oligomerization (1)
- Oligonucleotides (1)
- On-chip screening (1)
- On-line CE/MC-ICP-MS (1)
- On-site detection (1)
- One-bead-one-compound library (1)
- Online NMR Spectroscopy (1)
- Online NMR spectroscopy (1)
- Online biosensor (1)
- Online detection (1)
- Ontologies (1)
- Open science (1)
- Optical assay (1)
- Optical imaging (1)
- Optically active surfaces (1)
- Orbitrap (1)
- Organic Synthesis (1)
- Organic contaminants (1)
- Organic-inorganic hybrid composites (1)
- Organic–inorganic nanostructures (1)
- Osmotic minipumps (1)
- Oxidative metabolism (1)
- Oxygen evolution reaction (1)
- Oxygen isotope ratios (1)
- Oxygen sensitive (1)
- PAHs (1)
- PCA (1)
- PDT (1)
- PIC technology (1)
- PLSR (1)
- PSA (1)
- Packing density (1)
- Pants (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle architecture (1)
- Particle synthesis (1)
- Pattern recognition receptor (1)
- Pd(II) (1)
- Peer review (1)
- Peptide aptamers (1)
- Peptide binder (1)
- Peptide folding (1)
- Peptide mass fingerprinting (1)
- Peptide probe (1)
- Peptides (1)
- Peptides and Proteins (1)
- Per- and Polyfluoroalkyl substances (PFAS) (1)
- Per- and polyfluorinated alkyl substances (PFASs) (1)
- Perfluorooctanoic Acid (PFOA) (1)
- Permethrin (1)
- Peroxidase (1)
- Perturbed-Chain Statistical Association Fluid Theory (1)
- Pesticide (1)
- Petroleum (1)
- Pflanzenvirus (1)
- Pflanzenwachstum (1)
- Ph (1)
- Pharmaceutical (1)
- Pharmaceutical Science (1)
- Phase Imaging (1)
- Phenanthrene (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phl p 5 (1)
- Phleum pratense (1)
- Phosphinine (1)
- Phospholipids (1)
- Phosphor (1)
- Phosphorescence (1)
- Phosphorus elimination (1)
- Phosphorus recovery (1)
- Photocatalysis (1)
- Photocatalytic reduction (1)
- Photochemistry (1)
- Photoinduced Electron Transfer (1)
- Photoinduced electron transfer (1)
- Photonic biosensor (1)
- Photosensitization (1)
- Photostability (1)
- Physical and theoretical chemistry (1)
- Physical twin (1)
- Physico-chemical characterisation of minerals (1)
- Phytoliths (1)
- Planck function (1)
- Plant virus (1)
- Plant-model mismatch (1)
- Plasma chemistry (1)
- Plasmonic heating (1)
- Plastic deformation (1)
- Polarised light microscopy (1)
- Polarity (1)
- Polishing (1)
- Pollen (1)
- Pollen extract (1)
- Pollutant (1)
- Polyclonal Antibodies (1)
- Polycyclic aromatic hydrocarbon (PAH) (1)
- Polycyclic aromatic hydrocarbons (1)
- Polyelektrolyt (1)
- Polyglycerol (1)
- Polymer particles (1)
- Polymer-based products (1)
- Polymere (1)
- Polymerization (1)
- Polymers (1)
- Polyoxometalates (1)
- Polystyrene microparticles (1)
- Pore fluids (1)
- Porous rock (1)
- Porphyrin (1)
- Portable (1)
- Portland clinker (1)
- Potash (1)
- Powder X-ray diffraction (1)
- Power density (1)
- Pphotophysics (1)
- Prebiotic chemistry (1)
- Precision agriculture (1)
- Precision farming (1)
- Preprocessing (1)
- Primary difference measurement method (PDM) (1)
- Primary transfer standards (PTSs) (1)
- Primordial soup (1)
- Principal component analysis (PCA) (1)
- Priority effect (1)
- Process Analytical Tecnology (1)
- Process Industry (1)
- Process analytical technology (1)
- Process industry (1)
- Process intelligence (1)
- Process monitoring (1)
- Programmed cell death (1)
- Proinflammatory cytokines (1)
- Protein A (1)
- Protein Purification (1)
- Protein content (1)
- Protein degradation (1)
- Protein folding (1)
- Protein hydrolysis (1)
- Protein oligomerization (1)
- Protein oligomers (1)
- Protein quantification (1)
- Protein test (1)
- Protein-modification (1)
- Proteinoid (1)
- Provenance (1)
- Provenancing (1)
- Proximal soil sensing (1)
- Pseudomonas aeruginosa (1)
- Pt(111) (1)
- Pt(II) (1)
- PtNP (1)
- Public Health, Environmental and Occupational Health (1)
- Purification (1)
- Purity (1)
- Quality assurancemechanism (1)
- Quantitative Analysis (1)
- Quantitative determination (1)
- Quantitative protein analysis (1)
- Quantum chemistry (1)
- Quartz (1)
- R package (1)
- RBD (1)
- REMPI (1)
- Racemate (1)
- Rainwater (1)
- Raman-spectroscopy (1)
- Rapid test (1)
- Rat/human liver microsomes (1)
- Ratiometric (1)
- Reactor control (1)
- Real-time imaging (1)
- Real-time quality control (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Redox (1)
- Redox switch (1)
- Reference (1)
- Reference Material (1)
- Reference Materials (1)
- Reference data (1)
- References (1)
- Regeneration (1)
- Reliability (1)
- Remediation (1)
- Renal disease (1)
- Replication (1)
- Replication crisis (1)
- Reporter (1)
- Reproducibility crisis (1)
- Resistance (1)
- Resonance wavelength shift (1)
- Reverse microemulsion (1)
- Reversible covalent hydrazine chemistry (RCHC) (1)
- Rheumatoid arthritis (1)
- Rhizopus (1)
- Rhizopus and Aspergillus oryzae (1)
- Rhodamine (1)
- Ring resonator (1)
- River water sulfate (1)
- Robustness (1)
- Rosamine (1)
- Roughness (1)
- Ruthenium(II) complexes (1)
- SA conjugates (1)
- SAXS (1)
- SBA-15 (1)
- SBA-16 (1)
- SEM (1)
- SERDS (1)
- SERS (1)
- SIDA-LC-MS/MS (1)
- SKPFM (1)
- SOM-SM (1)
- SPR (1)
- SVOC (1)
- Safe by design (1)
- Salicylic acid (1)
- Salinomycin (1)
- Salts (1)
- Sample preparation (1)
- Scale anchor (1)
- Scale conversion (1)
- Scattering (1)
- Schlangenbohne (1)
- Schlieren Imaging (1)
- Schnelltest (1)
- Scientific publication (1)
- Seawater (1)
- Security (1)
- Sediment (1)
- Segregation (1)
- Selenium (1)
- Self-absorption (1)
- Self-assembled monolayers (SAM) (1)
- Semiconductor (1)
- Semiconductor nanocrystals (1)
- Semiconductor quantum dot (1)
- Sensor Materials (1)
- Sequence dependence (1)
- Sequencing (1)
- Sequencing algorithm (1)
- Serum (1)
- Shadowgraphy (1)
- Silica and polystyrene nanoparticles (1)
- Silica coating (1)
- Silica diagenesis (1)
- Silicon (1)
- Simulation (1)
- Single Cell (1)
- Single enhancement (1)
- Single particle ICP-MS (1)
- Single-cell analysis (1)
- Singlet oxygen (1)
- Sintered Material (1)
- Small-angle scattering (1)
- Smart sensors (1)
- Smart test laboratories (1)
- Smartphone readout (1)
- Soil contact (1)
- Soil heterogeneity (1)
- Sol-gel process (1)
- Solar cells (1)
- Solar concentrator (1)
- Solar energy (1)
- Solid (1)
- Solid state (1)
- Solid state emission (1)
- Solid-phase extraction (SPE) (1)
- Sorghum (1)
- Spark plasma sintering (1)
- Spatial heterodyne spectrometer (1)
- Special issue (1)
- Specific probe (1)
- Spectoscopic imaging (1)
- Spectrometer (1)
- Spectrometry (1)
- Spectroscopy / Instrumentation (1)
- Spectroscopy / Theory (1)
- Speed of sound (1)
- Spike protein (1)
- Sr isotope analysis (1)
- SsNMR (1)
- Stability (1)
- Stable isotopes (1)
- Standard atomic weight (1)
- Statistics (1)
- Steel (1)
- Stepwise growth (1)
- Stranski–Krastanow growth (1)
- Strontium isotope (1)
- Structural Biology (1)
- Structure-property relationship (1)
- Sub-4nm particles (1)
- Substance release (1)
- Sulfide sensing (1)
- Sulfur (1)
- Sulfur isotopes (1)
- Sulphur isotope (1)
- Sum Parameter (1)
- Sum Parameter Method (1)
- Sum parameter method (1)
- Supported catalyst (1)
- Supramolecular Chemistry (1)
- Surface Chemistry (1)
- Surface coating (1)
- Surface ligand (1)
- Surface plasmon resonance (1)
- Surface waters (1)
- Surface-enhanced Raman scattering (1)
- Surrogate citations (1)
- Sustainable Production (1)
- Suzuki coupling (1)
- Suzuki-Miyaura coupling (1)
- Swell-capture (1)
- Synchrotron FTIR (1)
- TEM (1)
- TFA (1)
- TLR4 activation (1)
- Tantalum oxyfluorides (1)
- Target (1)
- Tau (1)
- Temperature (1)
- Temperature Control (1)
- Terephthalic acid (1)
- Terrorism (1)
- Test strip (1)
- Teststreifen (1)
- Tetracyclin (1)
- Tetramethylammonium hydroxide (1)
- Theranostic (1)
- Therapeutic Antibodies (1)
- Thermocouple (1)
- Thermodynamic analysis (1)
- Thermography (1)
- Thick shells (1)
- Thickness (1)
- Tholins (1)
- Tissue (1)
- Titanium dioxide (1)
- ToF-SIMS (1)
- Toll-like receptor 4 (1)
- Tomography (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Total element determination (1)
- Toxicity testing (1)
- Toys (1)
- Trace Analysis (1)
- Transferrin (1)
- Transformation (1)
- Transient signal (1)
- Transpassive dissolution (1)
- Truffle (1)
- Truffle Aroma (1)
- Trust (1)
- Tryptic digest (1)
- Tryptophan (1)
- Tuber melanosporum (1)
- Type-I pyrethroids (1)
- UV Vis (1)
- UV radiation (1)
- UV–Vis spectroscopy (1)
- Ultrasensitive (1)
- Umweltschadstoffe (1)
- Upconverion (1)
- Upconverstion (1)
- Upscaling (1)
- Uptake studies (1)
- VO (1)
- VVOC (1)
- Validate method (1)
- Validation trial (1)
- Vanadium (1)
- Vanadium oxide catalysts (1)
- Vegetable edible oil (1)
- Veterinary drugs (1)
- Vigna unguiculata (1)
- Virial coefficients (1)
- Visualization (1)
- Vocabulary providers (1)
- Volatile organic compounds (1)
- Volatile organic compounds; (1)
- Volumetric uptake (1)
- WD-XRF (1)
- WWTP (1)
- Warfarin (1)
- Wasser (1)
- Wastewater (1)
- Water (1)
- Water contact (1)
- Wipe test (1)
- Wood chips (1)
- Work function (1)
- X-Ray analysis (1)
- X-Ray fluorescence (1)
- X-ray (1)
- X-ray diffraction (1)
- X-ray spectroscopy (1)
- XANES (1)
- YES assay (1)
- Yerba mate tea (1)
- Ytterbium (1)
- Zearalenone (1)
- Zearalenone sulfate (1)
- Zellulose (1)
- Zenodo (1)
- Zeolithe (1)
- Zinc (1)
- Zinc oxide (1)
- a-zearalenol (1)
- calibration (1)
- compost (1)
- dye (1)
- lank characterization (1)
- magnetic nanocatalysts (1)
- pH probe (1)
- photoluminescence (1)
- self-replication (1)
- spICP-MS (1)
- species-specific isotope information (1)
- tandard addition (1)
- temperature (1)
- thermophysical properties (1)
- transmission mode (1)
- β-Lactam (1)
- γ-H2AX assay (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (325) (entfernen)
Paper des Monats
- ja (11)
The presence of endocrine-disrupting compounds (EDCs) in water poses a significant threat to human and animal health, as recognized by regulatory agencies throughout the world. The Yeast Estrogen Screen (YES) assay is an excellent method to evaluate the presence of these compounds in water due to its simplicity and capacity to assess the bioaccessible forms/fractions of these compounds. In the presence of a compound with estrogenic activity, Saccharomyces cerevisiae cells, containing a lacZ reporter gene encoding the enzyme β-galactosidase, are induced, the enzyme is synthesised, and released to the extracellular medium. In this work, a YES-based approach encompassing the use of a lacZ reporter gene modified strain of S. cerevisiae, microcarriers as solid support, and a fluorescent substrate, fluorescein di-β-D-galactopyranoside, is proposed, allowing for the assessment of EDCs’ presence after only 2 h of incubation. The proposed method provided an EC50 of 0.17 ± 0.03 nM and an LLOQ of 0.03 nM, expressed as 17β-estradiol. The assessment of different EDCs provided EC50 values between 0.16 and 1.2 × 103 nM. After application to wastewaters, similar results were obtained for EDCs screening, much faster, compared to the conventional 45 h spectrophotometric procedure using a commercial kit, showing potential for onsite high-throughput screening of environmental contamination.
Peptide pools consist of short amino acid sequences and have proven to be versatile tools in various research areas in immunology and clinical applications. They are commercially available in many different compositions and variants. However, unlike other reagents that consist of only one or a few compounds, peptide pools are highly complex products which makes their quality control a major challenge. Quantitative peptide analysis usually requires sophisticated methods, in most cases isotope-labeled standards and reference materials. Usually, this would be prohibitively laborious and expensive. Therefore, an approach is needed to provide a practical and feasible method for quality control of peptide pools. With insufficient quality control, the use of such products could lead to incorrect experimental results, worsening the well-known reproducibility crisis in the biomedical sciences. Here we propose the use of ultra-high performance liquid chromatography (UHPLC) with two detectors, a standard UV detector at 214 nm for quantitative analysis and a high-resolution mass spectrometer (HRMS) for identity confirmation. To be cost-efficient and fast, quantification and identification are performed in one chromatographic run. An optimized protocol is shown, and different peak integration methods are compared and discussed. This work was performed using a peptide pool known as CEF advanced, which consists of 32 peptides derived from cytomegalovirus (CMV), Epstein–Barr virus (EBV) and influenza virus, ranging from 8 to 12 amino acids in length.
The non-steroidal anti-inflammatory drug (NSAID) diclofenac (DCF) is an important environmental contaminant occurring in surface waters all over the world, because, after excretion, it is not adequately removed from wastewater in sewage treatment plants. To be able to monitor this pollutant, highly efficient analytical methods are needed, including immunoassays. In a medical research project, monoclonal antibodies against diclofenac and its metabolites had been produced. Based on this monoclonal anti-DCF antibody, a new indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed and applied for environmental samples. The introduction of a spacer between diclofenac and the carrier protein in the coating conjugate led to higher sensitivity. With a test midpoint of 3 mg L−1 and a measurement range of 1–30 mg L−1, the system is not sensitive enough for direct analysis of surface water. However, this assay is quite robust against matrix influences and can be used for wastewater. Without adjustment of the calibration, organic solvents up to 5%, natural organic matter (NOM) up to 10 mg L−1, humic acids up to 2.5 mg L−1, and salt concentrations up to 6 g L−1 NaCl and 75 mg L−1 CaCl2 are tolerated. The antibody is also stable in a pH range from 3 to 12. Cross-reactivity (CR) of 1% or less was determined for the metabolites 40-hydroxydiclofenac (40-OH-DCF), 5-hydroxydiclofenac (5-OH-DCF), DCF lactam, and other NSAIDs. Relevant cross-reactivity occurred only with an amide derivative of DCF, 6-aminohexanoic acid (DCF-Ahx), aceclofenac (ACF) and DCF methyl ester (DCF-Me) with 150%, 61% and 44%, respectively. These substances, however, have not been found in samples. Only DCF-acyl glucuronide with a cross-reactivity of 57% is of some relevance. For the first time, photodegradation products were tested for cross-reactivity. With the ELISA based on this antibody, water samples were analysed. In sewage treatment plant effluents, concentrations in the range of 1.9–5.2 mg L−1 were determined directly, with recoveries compared to HPLC-MS/MS averaging 136%.
Concentrations in lakes ranged from 3 to 4.4 ng L−1 and were, after pre-concentration, determined with an average recovery of 100%
A systematic series of industrial-relevant polystyrene-based anion exchange resins that are functionalized with hydro- or fluorocarbon chains are compared regarding their adsorption behavior toward perfluorocarboxylic acids (PFCA) in respect to their charge, chain length, and type of chain. The results clearly show the dominance of electrostatic interactions in the adsorption process as uncharged adsorber materials showed no adsorption at all. In contrast, the charged adsorber materials showed in general a PFCA removal of 80% to 30% over the experiment depending on effluent fraction.
Unexpectedly, for perfluorobutanoic acid (PFBA) the highest removal rate is found with consistently >90%. Despite observing significant benefits in the adsorption of PFCA for fluoroalkylated adsorbers in comparison to their non-fluorinated counterparts, this effect of fluoroalkylation is comparatively small and can not be clearly attributed to fluorophilic interactions between the fluoroalkyl chains. These findings help clarifying that the introduction of fluorocarbon moieties in adsorber materials is not necessary in order to remove fluorocarbon molecules from the environment.
Changes in Black Truffle (Tuber melanosporum) Aroma during Storage under Different Conditions
(2024)
The enticing aroma of truffles is a key factor for their culinary value. Although all truffle species tend to be pricy, the most intensely aromatic species are the most sought after. Research into the aroma of truffles encompasses various disciplines including chemistry, biology, and sensory science. This study focusses on the chemical composition of the aroma of black truffles (Tuber melanosporum) and the changes occurring under different storage conditions. For this, truffle samples were stored under different treatments, at different temperatures, and measured over a total storage time of 12 days. Measurements of the truffle aroma profiles were taken with SPME/GC–MS at regular intervals. To handle the ample data collected, a systematic approach utilizing multivariate data analysis techniques was taken. This approach led to a vast amount of data which we made publicly available for future exploration. Results reveal the complexity of aroma changes, with 695 compounds identified, highlighting the need for a comprehensive understanding. Principal component analyses offer initial insights into truffle composition, while individual compounds may serve as markers for age (formic acid, 1-methylpropyl ester), freshness (2-Methyl-1-propanal; 1-(methylthio)-propane), freezing (tetrahydrofuran), salt treatment (1-chloropentane), or heat exposure (4-hydroxy-3-methyl-2-butanone). This research suggests that heat treatment or salt contact significantly affects truffle aroma, while freezing and cutting have less pronounced effects in comparison. The enrichment of compounds showing significant changes during storage was investigated with a metabolomic pathway analysis. The involvement of some of the enriched compounds on the pyruvate/glycolysis and sulfur pathways was shown.
Amphiphilic nanogels (ANGs) are promising carriers for hydrophobic cargos such as drugs, dyes, and catalysts.
Loading content and release kinetics of these compounds are controlled by type and number of hydrophobic groups in the amphiphilic copolymer network. Thus, understanding the interactions between cargo and colloidal carrier is mandatory for a tailor-made and cargo-specific ANG design. To systematically explore the influence of the network composition on these interactions, we prepared a set of ANGs of different amphiphilicity and loaded these ANGs with varying concentrations of the solvatochromic dye Nile Red (NR). Here, NR acts as a hydrophobic model cargo to optically probe the polarity of its microenvironment. Analysis of the NR emission spectra as well as measurements of the fluorescence quantum yields and decay kinetics revealed a decrease in the polarity of the NR microenvironment with increasing hydrophobicity of the hydrophobic groups in the ANG network and dye–dye interactions at higher loading concentrations. At low NR concentrations, the hydrophobic cargo NR is encapsulated in the hydrophobic domains. Increasing NR concentrations resulted in probe molecules located in a more hydrophilic environment, i.e., at the nanodomain border, and favored dye–dye interactions and NR aggregation.
These results correlate well with release experiments, indicating first NR release from more hydrophilic network locations. Overall, our findings demonstrate the importance to understand carrier–drug interactions for efficient loading and controlled release profiles in amphiphilic nanogels.
On-line coupled high performance liquid chromatography-gas chromatography-flame ionisation detection (HPLC-GC-FID) was used to compare the effect of hydrogen, helium and nitrogen as carrier gases on the chromatographic characteristics for the quantification of mineral oil hydrocarbon (MOH) traces in food related matrices. After optimisation of chromatographic parameters nitrogen carrier gas exhibited characteristics equivalent to hydrogen and helium regarding requirements set by current guidelines and standardisation such as linear range, quantification limit and carry over. Though nitrogen expectedly led to greater peak widths, all required separations of standard compounds were sufficient and humps of saturated mineral oil hydrocarbons (MOSH) and aromatic mineral oil hydrocarbons (MOAH) were appropriate to enable quantitation similar to situations where hydrogen or helium had been used. Slightly increased peak widths of individual hump components did not affect shapes and widths of the MOSH and MOAH humps were not significantly affected by the use of nitrogen as carrier gas. Notably, nitrogen carrier gas led to less solvent peak tailing and smaller baseline offset. Overall, nitrogen may be regarded as viable alternative to hydrogen or helium and may even extend the range of quantifiable compounds to highly volatile hydrocarbon eluting directly after the solvent peak.
Scattering luminescent materials dispersed in liquid and solid matrices and luminescent powders are increasingly relevant for fundamental research and industry. Examples are luminescent nano- and microparticles and phosphors of different compositions in various matrices or incorporated into ceramics with applications in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. The key parameter to characterize the performance of these materials is the photoluminescence/fluorescence quantum yield (Φf), i.e., the number of emitted photons per number of absorbed photons. To identify and quantify the sources of uncertainty of absolute measurements of Φf of scattering samples, the first interlaboratory comparison (ILC) of three laboratories from academia and industry was performed by following identical measurement protocols. Thereby, two types ofcommercial stand-alone integrating sphere setups with different illumination and detection geometries were utilized for measuring the Φf of transparent and scattering dye solutions and solid phosphors, namely, YAG:Ce optoceramics of varying surface roughness, used as converter materials for blue light emitting diodes. Special emphasis was dedicated to the influence of the measurement geometry, the optical properties of the blank utilized to determine the number of photons of the incident excitation light absorbed by the sample, and the sample-specific surface roughness. While the Φf values of the liquid samples matched between instruments, Φf measurements of the optoceramics with different blanks revealed substantial differences. The ILC results underline the importance of the measurement geometry, sample position, and blank for reliable Φf data of scattering the YAG:Ce optoceramics, with the blank’s optical properties accounting for uncertainties exceeding 20%.
The ability to controllably move gaseous ions is an essential aspect of ion-based spectrometry (e.g., mass spectrometry and ion mobility spectrometry) as well as materials processing. At higher pressures, ion motion is largely governed by diffusion and multiple collisions with neutral gas molecules. Thus, high-pressure ion optics based on electrostatics require large fields, radio frequency drives, complicated geometries, and/or partially transmissive grids that become contaminated. Here, we demonstrate that low-power standing acoustic waves can be used to guide, block, focus, and separate beams of ions akin to electrostatic ion optics. Ions preferentially travel through the static-pressure regions (“nodes”) while neutral gas does not appear to be impacted by the acoustic field structure and continues along a straight trajectory. This acoustic ion manipulation (AIM) approach has broad implications for ion manipulation techniques at high pressure, while expanding our fundamental understanding of the behavior of ions in gases.
Ergot alkaloids (EAs) formed by Claviceps fungi are one of the most common food contaminants worldwide, affecting cereals such as rye, wheat, and barley. To accurately determine the level of contamination and to monitor EAs maximum levels set by the European Union, the six most common EAs (so-called priority EAs) and their corresponding epimers are quantified using high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS). The quantification of EAs in complex food matrices without appropriate internal tandards is challenging but currently carried out in the standard method EN 7425:2021 due to their commercial unavailability. To address the need for isotopically labeled EAs, we focus on two semi-synthetic approaches for the synthesis of these reference standards. Therefore, we investigate the feasibility of the N6-demethylation of native ergotamine to yield norergotamine, which can subsequently be remethylated with an isotopically labeled methylating reagent, such as iodomethane (13CD3-I), to yield isotopically labeled ergotamine and its C8-epimer ergotaminine. Testing the isotopically labeled ergotamine/-inine against native ergotamine/-inine with HPLC coupled to high-resolution HR-MS/MS proved the structure of ergotamine-13CD3 and ergotaminine-13CD3. Thus, for the first time, we can describe their synthesis from unlabeled, native ergotamine. Furthermore, this approach is promising as a universal way to synthesize other isotopically labeled EAs.