This contribution provides an overview of the BAMline synchrotron radiation beamline, which specializes in hard X-ray spectroscopy techniques for materials research. The BAMline offers X-ray absorption spectroscopy (XAS), x-ray fluorescence spectroscopy (XRF), and tomography to study materials' electronic structure, chemical composition, and structure. Key capabilities include standard and dispersive XAS for electronic structure, micro-XRF for elemental mapping, coded aperture imaging, and depth-resolved grazing exit XAS. The BAMline enables in situ characterization during materials synthesis and functions for energy, catalysis, corrosion, biology, and cultural heritage applications.
Ongoing developments like the implementation of machine learning techniques for experiment optimization and data analysis will be discussed. For instance, Bayesian optimization is being used to improve beamline alignment and scanning. An outlook to the future, where the BAMline will continue pioneering dynamic and multi-scale characterization, aided by advanced data science methods, to provide unique insights into materials research, will be given.
Time is the most valuable parameter in synchrotron experiments. This is costly and some of the experiments suffer from low efficiency due to low counting statistics. With today's high processing power long experiments are run in a shorter time and increase efficiency. With optimization algorithms time in "counting-hungry" experiments reduced by factor of 10. Our project is to develop a new method to analyze the chemical properties of complex materials non-destructively and efficiently, such as high entropy materials subjected to corrosion processes. A better understanding of the corrosion process will help to develop corrosion-resistant materials and reduce the cost of corrosion damage, which averages around 2.5 trillion USD annually.
The components that are used in structural and in high temperature applications generally face significant challenges with respect to oxidation behaviours and metalworking processes. In most of the cases, harsh environmental conditions lead materials to degrade due to corrosion. To thoroughly investigate the corrosion processes and to determine oxidation states of metal components within the reaction products, we need special analytical tools. Grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect this information in sub-micrometre depth range.
In order to obtain structural information, such as regarding oxidation states or atomic/molecular geometric arrangement, the GEXRF approach can also be combined with the X-ray absorption spectroscopy (XAS) method. The position and energy sensitive detector, with 264x264 pixel detector area, provides information regarding the signal emitted from the sample as a function of the emission angle and thus allows depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which can be controlled with a resolution of 0.5 eV provides XANES data to determine oxidation states.
We address the feasibility of our setup and provide a new optimization procedure (Bayesian Optimization and Gaussian Regression) to decrease measuring time. The results settle on a conceptual study on a reference sample (Cr-Oxide layer (300nm) on Cr layer (500nm) on Si wafer).
The components that are used in structural and in high temperature applications generally face significant challenges with respect to oxidation behaviours and metalworking processes. In most of the cases, harsh environmental conditions lead materials to degrade due to corrosion. To thoroughly investigate the corrosion processes and to determine oxidation states of metal components within the reaction products, we need special analytical tools. Grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect this information in sub-micrometre depth range.
In order to obtain structural information, such as regarding oxidation states or atomic/molecular geometric arrangement, the GEXRF approach can also be combined with the X-ray absorption spectroscopy (XAS) method. The position and energy sensitive detector, with 264x264 pixel detector area, provides information regarding the signal emitted from the sample as a function of the emission angle and thus allows depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which can be controlled with a resolution of 0.5 eV provides XANES data to determine oxidation states.
We address the feasibility of our setup and provide a new optimization procedure (Bayesian Optimization and Gaussian Regression) to decrease measuring time. The results settle on a conceptual study on a reference sample (Cr-Oxide layer (300nm) on Cr layer (500nm) on Si wafer).
Compositionally complex alloys (CCAs) are a new class of alloys containing at least 5 elements with concentrations between 5 and 35 atomic percent. Due to their adjustable composition, which enables modifications of mechanical properties (such as hardness, strength and ductility etc) and their stability at high temperatures, CCAs have been the focus of various studies [1,2]. Especially the corrosion behavior of CCAs has been a wide research interest.
However, there are only few studies that deals with the degradation process on such materials, which is highly relevant for the safety aspect for future component design. To thoroughly investigate the corrosion processes and to determine oxidation states of metal components within the reaction products, we need special analytical tools. Since the grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect notable information regarding the high temperature oxidation, we consider it as a useful method to investigate how CCAs behave in corrosive environments.
The main idea of grazing geometry is to enhance the fluorescence signal of the surface. This enables highly sensitive surface analyses of thin protective film on surface in sub-micrometer scale [3]. When compared to a conventional CCD-based camera, the advantage and most important feature of the detector system (Color X-Ray Camera (CXC)) is that each pixel is an energy sensitive detector. The position and area sensitive detector, with 264x264 pixel detector area, provides information regarding the signal emitted from the sample as a function of the emission angle and thus allows depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which can be controlled with a resolution of 0.5 eV provides XANES data to determine oxidation states.
In this contribution, we address the feasibility of our setup and new optimization procedure (Bayesian Optimization and Gaussian Regression). The results of a conceptual study regarding layer properties of the reference sample (Cr-Oxide layer (300nm) on Cr layer (500nm) on Si wafer) and CrCoNi (Cr-Oxide (>1µm) layer on CrCoNi substrate) medium entropy alloy.
High entropy alloys (HEAs) are considered as a new class of alloys containing at least 5 elements with concentrations between 5 and 35 atomic percent. There has been a growing interest in HEAs in the material research field in recent years. Due to their adjustable composition, which enables the modifications of mechanical properties (such as hardness, strength and ductility etc) and their stability at high temperatures, HEAs have been the focus of various studies.
Especially the corrosion behavior of HEAs has been a wide research interest. Since the grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect notable information regarding the high temperature oxidation, we consider it as a useful method to investigate how HEAs behave in corrosive environments.
The main idea of grazing geometry is to enhance the fluorescence signal of the surface. This enables highly sensitive surface analyses of thin protective film on surface in sub-micrometer scale. Position-sensitive area detectors provide information regarding the signal emitted from the sample as a function of emission angle and thus allow depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which lays within a specific energy range provides XANES data to determine oxidation states. Moreover, since GEXRF profiles can also be simulated through physical models (Urbach 1999), they enable us to determine the layer thickness of a given sample in a non-destructive way.
In this contribution, we present the preliminary results of a conceptual study regarding layer properties of CrCoNi medium entropy alloy. The successful implementation of such methodological concept will pave the way for the investigation of more complex alloys with multiple layers, which is planned for the later phases of the project.
High entropy alloys (HEAs) are considered as a new class of alloys containing at least 5 elements with concentrations between 5 and 35 atomic percent. There has been a growing interest in HEAs in the material research field in recent years. Due to their adjustable composition, which enables the modifications of mechanical properties (such as hardness, strength and ductility etc) and their stability at high temperatures, HEAs have been the focus of various studies.
Especially the corrosion behavior of HEAs has been a wide research interest. Since the grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect notable information regarding the high temperature oxidation, we consider it as a useful method to investigate how HEAs behave in corrosive environments.
The main idea of grazing geometry is to enhance the fluorescence signal of the surface. This enables highly sensitive surface analyses of thin protective film on surface in sub-micrometer scale. Position-sensitive area detectors provide information regarding the signal emitted from the sample as a function of emission angle and thus allow depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which lays within a specific energy range provides XANES data to determine oxidation states. Moreover, since GEXRF profiles can also be simulated through physical models (Urbach 1999), they enable us to determine the layer thickness of a given sample in a non-destructive way.
In this contribution, we present the preliminary results of a conceptual study regarding layer properties of CrCoNi medium entropy alloy. The successful implementation of such methodological concept will pave the way for the investigation of more complex alloys with multiple layers, which is planned for the later phases of the project.
Polymer electrolyte membranes (PEM) are polymers which act as separator in an electrochemical cell and allow ionic charge flow to close the circuit. Widely used membranes are perfluorinated sulfonic-acid (PFSA) ionomers (e.g. Nafion™), a class of ion-conducting polymers with remarkable ion conductivity and chemical-mechanical stability. A nanoscopic water system around the sulfonic acid capped side-chains of the otherwise hydrophobic polymer allows the ion transport. Only approx. 14 molecules of water per sulfonic group are present in the fully hydrated state. In vanadium redox flow batteries (VRFB) ideally only protons are transported. The weak ion selectivity of Nafion™ is the main cause for the transportation of vanadium, briefly vanadium crossover, in VRFBs a system we have investigated more closely, lately. The consequences of crossover are a concentration imbalance and a self-discharge of the battery, which leads to a decrease of the capacity. The development of efficient energy storage systems is crucial for the transformation towards a renewable energy based economy. The VRFB has a great potential as a commercial electrochemical energy storage system due to properties including, but not limited to, no cross-contamination, a long cycle-life and a theoretically unlimited capacity. VRFB consists of two half-cells, which are linked to electrolyte tanks and separated by a membrane. The membrane plays a major role in overall cell performance. So far, vanadium transportation models, which include diffusion, migration, electroosmotic convection and pressure gradients, are inconsistent. There is no agreement in the literature on the diffusion coefficients of vanadium species (e.g. published diffusion coefficients of V2+ are located between 3.13·10-12 m²s-1 and 9.44·10-12 m²s-1) indicate that thevanadium crossover is not well understood and there is a lack on a more fundamental level. Since the membrane transport is the rate-determining step of the crossover as well as of the proton exchange it is extremely important to understand these phenomena on a fundamental level. This will eventually allow us to design better membranes. Alternative materials need to show equivalent performance compared with Nafion™ and ideally be more selective regarding ion cross-membrane transport.There are several options to approach the chemistry i.e. the interaction of dissolved and bound ions inside the confined water body of ionomeric membranes. Vanadium ions are a versatile model as UV/VIS data can be used to distinguish between the 5 species V2+, V3+, VO2+, VO2+ and V2O33+ of the electrolyte. Infrared spectroscopy has been applied to study the interaction of sulfonic groups and the ions. Molecular dynamic modeling is another approach to study the distribution and distances of ions. We now introduce X-ray absorption near edge structure spectroscopy (XANES) to study species and species changes inside Nafion™ and a novel membrane based on poly(1,1-difluoroethylene) (PVDF). We evaluated the methods and investigated the influence of irradiation, temperature and hydration on the measurements.
Vanadium redoxflow batteries (VRFB)are currently one of the most promising candidates for stationary energys torage.For large scale applications the ion conducting membranes currently in use need to be improved. Ideally,they need to become more cost efficient and selective regarding the vanadium crossover.For a better understanding of the vanadium crossover, the development of reliable analytical methods and procedures, that elucidate uptake and transport of vanadium ions in the membrane, is necessary. First, we present the uptake of V2+,V3+,VO2+, VO2+ and V2O33+ in Nafion™ and in a novel membrane based onpoly(1,1-difluoroethylene)(PVDF). In preliminary discharge/charge experiments the ETFE-based membrane, the precursor of PVDF-based membrane, performed comparable to Nafion™. The methods of choice for speciation are UV/Vis and X-ray absorption near edge structure spectroscopy (XANES). According to the results, V2O33+, formed from VO2+ and VO2+, diffuses also into the membrane. In present models, the diffusion of V2O33+ is neglected. In addition,we study whether reactions could take place inside the membranes’ nanoscopic water body using XANES. Exposing Nafion™ from one site with V3+a nd from the other site with VO2+ realized the experiment. The results verified that VO2+ was formed inside the membrane. However,in present models reactions inside the membrane are neglected, too.
Synchrotron radiation sources with their unique properties in terms of intensity, polarization and adjustability offer a wide range of possibilities in materials research. A basic introduction about the creation and special properties of synchrotron radiation will be given. Examples of current work at BAMline, the high-energy measuring facility of the Federal Institute for Materials Research and Testing at the synchrotron BESSY, are used to illustrate the possibilities and limitations of existing measuring methods. It will be shown how the formation of corrosion layers can be tracked, how the abrasion of implants leads to the introduction of heavy metals into the surrounding bone matrix and how the detection of smallest impurities in gold is possible by optimizing the measuring conditions. Finally, an outlook at the hardware and software developments to be expected in the coming years is given.
In a rapidly evolving world, the demand on raw materials is increasing steadily and many technologies are dependent on a secure supply of hi-tech metals. Recently, scandium (Sc) has attracted attention since its use in high strength Al-alloys and solid-oxide-fuel-cells strongly improves the performance of those materials.
The element Sc is not exceptionally rare but quite resistant to geochemical enrichment processes, it is scarcely found enriched to high concentrations and is recovered as a by-product. Since Sc enrichment in Greek bauxite residues was shown by Ochsenkühn-Petropoulou et. al (1994), intensive research on this material and development of efficient Sc-recovery methods is ongoing.
This study investigates Sc-bearing species in bauxite residues from alumina production. It aims to provide direct evidence about the Sc-speciation’s in those secondary resources and tries to find the link to speciation’s in primary resources, e.g. bauxites and laterites.
Therefore, Sc K edge XANES (X-ray absorption near edge structure) spectroscopy is performed using synchrotron radiation to determine the presence of certain Sc-components and distinguish between adsorbed and chemically bonded Sc as was shown for lateritic deposits in Australia by Chassé et al. 2016. For comparison, reference standards of Sc-bearing and Sc-adsorbed species are synthesized. Indirect inferences from leaching behavior of bauxites, in cases supported by analyses with LA-ICP-MS, suggest Sc to be associated with either iron- or aluminum phases (Vind et al. 2017); (Suss et al.). It remains unclear how different primary materials influence Sc-speciation in the bauxite residue. Therefore, a comparison between different European bauxite residues is made in this study. The investigations should help to understand Sc chemistry and
behavior in different primary and secondary materials and provide fundamentals for metallurgical processing. The research is incorporated in the SCALE project (GA No. 730105) funded by EU Horizon 2020 research and innovation program.
XAFS@BAMline
(2018)
X-ray Absorption fine structure spectroscopy (XAFS) is a frequently employed technique in order to investigate structural composition and Change of chemical compounds such as catalytic species or corrosion processes. These structural properties are essential (i) to understand underlying reaction mechanism and (ii) to further improve the design of materials.
While XAFS measurements are usually performed with ionization Chambers or simple fluorescence detectors, we at BAMline specialize in measurements with innovative set-ups that meet Specialrequirements such as time resolution, (3D-) spatial Resolution or demanding sample environments.
This contribution presents various available XAFS configurations with their corresponding applications. In particular, these comprise single -shot XAFS for time- resolved measurements, grazing-exit XAFS with energy and a spatially resolved detector for the characterization of thin films and an in situ grazing incidence Setup for the characterization of corrosion layers.
Additionally,the possibility of analyzing Minute samples in total-reflection geometry is demonstrated.
X-ray absorption fine structure spectroscopy (XAFS) is a frequently employed technique in order to investigate structural composition and change of chemical compounds such as catalytic species. These structural properties are essential (i) to understand underlying reaction mechanism and (ii) to further improve the design of efficient catalysts.
This investigation is based on a newly developed XAFS setup comprising both time- and lateral-resolved XAFS information simultaneously in a single-shot (S2XAFS). The primary broadband beam is generated by a filter/X-ray-mirror combination (bandpass). The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by an area sensitive detector with a theta to 2 theta geometry. This facile, stable and scanningless setup was tested at the BAMline @ BESSY-II (Berlin, Germany).
This contribution focuses on further experimental optimizations allowing the characterization of supported vanadium oxide (VOx) based catalysts at the lower hard X-ray regime (5 to 6 keV). First S2XAFS measurements of these catalysts are presented herein. Supported VOx catalysts show promising results in the oxidation of methane to formaldehyde.
S2XAFS allows determining the structural composition of the metal (i.e. vanadium) based on a fast and smart setup. It is therefore an ideal tool to identify crucial roles of chemical compounds in catalytic reactions.
Ferritic high temperature alloys are widely used as boiler tube and heat exchanger materials in coal, biomass and co-fired power plants. All technologies have in common that the applied materials are exposed to different temperatures, process pressures and reactive atmospheres that lead to a change of the material properties and a further degradation of the material. Material changes caused by aging in highly corrosive and toxic gases such as SO2 are mainly studied ex situ after the reaction is finished. The solid material is deposited in the atmosphere for a certain period of time, and material changes are then examined by various microscopic techniques such as optical microscopy (OM), electron microprobe analysis (EMPA), scanning electron microscopy (SEM and TEM) and X-ray diffraction (XRD). Nevertheless, extensive efforts were made to study material changes of high temperature alloys under oxidizing and reducing atmospheres by environmental scanning electron microscopy or in situ TEM techniques However, the possibilities of microscopic in situ techniques are very limited for the use of highly corrosive and toxic gases such as SO2. Since Sulfur induced corrosion at temperatures relevant for coal and biomass fired power plants, which is causing breakaway oxidation and sulfide precipitation at grain boundaries, is still of scientific interest, the current work focuses on the effect of SO2 in an initial stage of corrosion of ferritic alloys. For the analysis of early stages of combined oxidation and sulphidation processes of Fe-Cr model alloys the usage of a light furnace to conduct a rapid reactive annealing experiment is feasible. Previous studies presented distinct results of the influence of chromium on early high temperature corrosion by SO2 by this technique and subsequent classical metallographic analyses. However, it is still not possible to trace the corrosion mechanism in real time by conducting single aging experiments. The current work introduces two different approaches to study the initial stages of high temperature oxidation processes by applying above state of the art X-ray diffraction and spectroscopy methods. One part focuses on the real time observation of the formation of corrosion products such as oxides and sulfides by energy dispersive X-ray diffraction (EDXRD). The potential of this technique to study crystallization and growth processes of thin films in a reactive environment in real time was previously shown for different compound semiconductors. This approach was now applied to follow oxidation and sulphidation processes of ferritic model alloys in SO2 and SO2/H2O environments. The diffraction signals of the X-rays were detected during the corrosion process and the peak area and positions were analyzed as a function of time. This procedure enables monitoring external oxide growth and material loss in real time in an early stage of corrosion.
The other part of the current work presents the possibilities of X-ray absorption near edge structure spectroscopy (XANES) to characterize oxide scales and their growth mechanisms. Precise phase identification and quantification of corrosion products in a multi-phase oxide/sulfide scale is a pre-requisite to understand diffusion paths of metal ions and gas components. It is a challenging task to distinguish structurally similar reaction products such as Fe3O4 and FeCr2O4 especially in thin films with texture effects by diffraction. To illustrate for example Cr-out diffusion of an alloy throughout an inner and external oxide scale the differentiation of Fe3O4 and FeCr2O4 is indispensable. XANES uses the photoionization effect at the metal absorption edge in an aging product and accesses by this structural and chemical information. The current work uses XANES at the Fe-K and Cr-K absorption edge to identify various aging products grown as thin layers on alloys after short time aging experiments. A reaction chamber for combining high temperature oxidation experiments with surface sensitive X-ray absorption near edge structure spectroscopy will be introduced and first results of XANES on scales at high temperatures will be presented.
Ferritic-martensitic alloys with 12-16 % Cr in weight are subject to devices for various energy systems, such as coal power plants and waste incineration plants. These materials are exposed to a highly corrosive environment which lead to a degradation of the material. Especially the simultaneous oxidation and sulfidation is thereby of special interest. Proper spatially resolved measurements that determine not only chemical compositions but phases are rare. However, precise phase identification and quantification of corrosion products within the multi-phase corrosion scales is a key aspect to understand diffusion paths of metal ions and gas ions/molecules. This study investigated Fe-Cr model alloys with Cr contents from 0 to 13 % in weight in 0.5 % SO2 and 99.5 % Ar atmosphere to aim in a fundamental and systematic analysis. Samples were aged at 650 °C for time scales from 12 h to 250 h. The results presented here correspond to depth dependent phase identification of oxide and sulphide phases in the corrosion scales by using X-ray absorption near edge spectroscopy (XANES). Per sample a series of ca. 20 spots (1-5 µm spot size) from scale-gas to scale-metal interface were measured. XANES spectroscopy was performed at the Fe-K edge (7.11 keV) on polished cross sections. The collected spectra were fitted to a combination of reference materials to quantify the present phases at different positions within the scale.The phase distribution differs with Cr content and the Cr diffusion through pure Fe-oxide and mixed Fe-Cr-oxide phases is discussed.
The BAMline at the synchrotron BESSY II in Berlin supplies users with up to date analytical x-ray methods for the energy range between 5 and 50 keV. Additional to XRF with micron Resolution it provides amongst other things the possibility to use TXRF and XANES. Especially the use of
the so-called Color X-Ray Camera (CXC) opens the possibility to use new and effective detection schemes, which allow to measure simultaneously distributions of elements or Absorption spectra in a motionless mode.
In this talk the analytical possibilities at the BAMline for samples with biological Background will be introduced. The available methods will be presented and discussed for various examples.
A perspective for the future use for XANES in grazing emission and TXRF geometries for plant materials will be given.
Metal reducing bacteria (MRB) are capable of utilizing different metals, such as iron, chromium, manganese or uranium as well as many organic compounds, as electron acceptors for their metabolism. Via direct and indirect electron transfer processes MRB are able to convert insoluble passive film species like Fe(III)-oxides to soluble Fe(II)-oxides and hydroxides. This weakening of the passive film not only leads to an acceleration of the general corrosion processes, but also increases the susceptibility of stainless steels to pitting corrosion. Electron transfer mechanisms are not yet fully understood and the role of bacteria in corrosion processes is controversially discussed in the literature. Moreover, recent research indicates that the secretion of electron shuttles like riboflavins by MRB also contributes to the extracellular electron transfer.
This project aims at clarifying the chemical and electrochemical interaction mechanisms of MRB with stainless steel surfaces. To investigate the changes in the oxide chemistry on the stainless steel surface in the presence of biomolecules and MRB a new flow cell has been designed and constructed which enables the collection of XANES (X-ray Absorption Near Edge Structure) spectra in fluorescence mode at the Fe K-edge and electrochemical analysis. Availability of oxygen and the pre-exposure of the MRB to Fe(III) during cultivation have been investigated as parameters with significant effect on the corrosion rates. XANES analysis is supplemented by ex-situ X-Ray Photoelectron Spectroscopy (XPS) and Fourier Transform Infrared Reflection Absorption Spectroscopy (FT-IRRAS) to complete the surface characterisation in terms of the oxide chemistry and the composition of organic residues. Complementary electrochemical quartz crystal microbalance (e-QCM) measurements have been performed to quantify the kinetics of bacterial attachment and biofilm formation. Together with the frequency shift, the evolution of the dissipation signal has been analyzed to investigate the changes in viscosity and structure of the biofilm from initial stages up to maturation. Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM) has been used to study the structure and viscoelastic properties of the biofilms after e-QCM experiments.
The presentation will summarize our results on the effects of individual surface and environment related parameters on the chemical/electrochemical interaction mechanisms of MRB leading to passive film degradation on stainless steel surfaces and provide useful insights from a fundamental aspect for the development of novel mitigation strategies for microbiologically influenced corrosion.
News from the BAMline
(2017)
Airborne particulate matter is a topic of growing interest. Particles with aerodynamic diameters less than 10 μm (PM 10) and especially the fine fraction below 2.5 μm (PM2.5) are of particular importance, as they can enter the human respiratory system and cause acute and
chronic respiratory or cardiovascular diseases. The mass distribution of airborne particles in dependence of their diameters is well-known, but also the abundance and temporal variation of trace elements in air (mass concentrations down to the pg/m³ range) are crucial.
These elements originate from various natural (abrasion, erosion) and anthropogenic sources (combustion, road traffic), which complicate the discrimination between harmless and toxic emissions. Some new methods of investigation are therefore needed and X-ray fluorescence spectroscopy has ascertained ist huge potential in this matter, thanks to the possibility to determine simultaneously, in a time-resolved manner, the mass concentrations of critical elements which can be considered as markers of a potential toxic source. A method for the quantitative Analysis of airborne particles directly collected on sample substrates (30 mm quartz reflectors and 1" Si wafers suited for total-reflection X-ray fluorescence analysis (TXRF) will be presented.
Samplings were performed using a three- stage Dekati™ PM10 impactor (>10 μm, 2.5 to 10 μm and 1 to 2.5 μm) and a four-stage Sioutas Personal Cascade Impactor (>2.5 μm, 1 to 2.5 μm,0.5 to 1 μm and 0.25 to 0.5 μm) at indoor and outdoor sites at the Atominstitut (Vienna, Austria). Quantitative results of two outdoor test sampling campaigns (July 2016 and January 2017) will be presented and discussed. Low detection limits were assessed via TXRF and range from several 10 to several 100 pg/m³ depending on the element and particle size fraction.
Ferritic steels with chromium contents up to 13 wt% are used as materials for power plant components as boiler materials (< 2 wt% Cr) and super heater tubes (> 9 wt% Cr). These materials are subject to aggressive corrosion caused by hot gases such as CO2, H2O, O2 and SO2. Especially SO2 causes fatal corrosion even as a minor component. To examine sulfurous corrosion mechanisms, experiments with pure SO2 were conducted. A proper analysis of the material changes requires phase identification and quantification with a high lateral resolution within the corrosion scale.
Metal reducing bacteria (MRB) are able to utilize various materials such as iron, uranium and manganese as well as many organic compounds as electron acceptors. This process leads to the conversion of Fe(III) containing passive film species to soluble Fe(II) oxides and hydroxides. The reduction process triggers the acceleration of general and local corrosion processes. Electron transfer mechanisms are not yet fully understood. In literature it has been controversially discussed to which extend secreted electron shuttles contribute to the extracellular electron transfer (EET).
To understand the chemical and electrochemical interaction mechanisms of MRB with steel surfaces this project combines a variety of in-situ techniques. The changes in oxide chemistry on Fe/steel surfaces in the presence of biomolecules and MRB are under investigation using a newly designed electrochemical cell for in situ XANES (x-ray absorption near edge structure) spectroscopy. Electrochemical quartz crystal microbalance (eQCM) studies support the spectroscopic investigations to gain information about the kinetics of attachment processes and changes in biofilm viscosity. The biofilm structure and composition as well as cell viability are investigated by complementary ex situ spectroscopic and microscopic analysis.
Combining spectroscopic techniques and eQCM data with electrochemical measurements, biological processes and the resulting degradation of steel surfaces can be observed in a non-destructive manner. Selecting model systems and a defined biological medium allows the determination of individual effects of diverse surface and environmental parameters. The fundamental understanding of bacterial attachment mechanisms and initial steps of biofilm formation will contribute to the development of new antifouling strategies.
Time-resolved studies on the formation of maghemite nanoparticles combining fast-XANES and SAXS
(2016)
Iron oxide nanoparticles find application in different areas like sensing, magnetic storage media, and biomedicine, due to their magnetic properties and environment-friendliness.
In the present contribution, we report on the in situ investigation of an iron oxide nanoparticle synthesis by coupled X-ray absorption near-edge structure (XANES) and small-angle X-ray scattering (SAXS). The combination provides simultaneously information about the size of particles (SAXS) and on the oxidation state and the local structure of the iron atoms (XANES). The co-precipitation synthesis was exemplary studied, using a stabilization agent to decelerate the fast precipitation of the iron oxides. This allows to detect intermediates in situ. The measurements were performed using a custom-made acoustic levitator as sample holder. From the data, a mechanism was derived indicating different phases of particle Formation and oxidation state changes.
The role of metal reducing bacteria (MRB) in corrosion is being controversially discussed in the literature. They can utilize metals including iron, uranium and manganese as well as many organic compounds as electron acceptors. The reduction of Fe(III) compounds to soluble Fe(II) species leads to the destruction of passive films on steel, resulting in acceleration of general and local corrosion processes. Recent research shows that the secretion of electron shuttles like riboflavins also contribute to the extracellular electron transfer (EET).
The aim of this project is to understand the chemical and electrochemical interaction mechanisms of MRB with steel surfaces by means of combined in situ techniques. An electrochemical XANES (x-ray absorption near edge spectroscopy) cell has been designed to study the changes of passive film chemistry in the presence of biomolecules and MRB. Electrochemical quartz crystal microbalance (eQCM) is used for studying the kinetics of bacterial cell attachment and diffusion of biomolecules in model biofilms. In situ investigations are complemented by ex situ spectroscopic and microscopic analysis to investigate the biofilm structure, composition and cell viability.
Via the combination of electrochemical methods with spectroscopic techniques and QCM we are able to follow biological processes and resulting degradation of steel surfaces in a non-destructive manner. The selection of model systems and a defined biological medium allows the identification of the effects of individual surface and environmental parameters. The fundamental understanding of bacterial attachment mechanisms and initial steps of biofilm formation will contribute to the development of new antifouling strategies.
Wilson´s disease (WD) is a rare genetic disorder of the copper metabolism, causing the accumulation of copper in different organs, including the liver, the central nervous system and cornea. This way, WD initiates manifold hepatic, neurological or psychiatric symptoms. To learn about the elemental distribution and present species in WD, liver samples were analyzed by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), micro X-ray fluorescence (μXRF) and X-ray absorption near edge structure spectroscopy (XANES).
Within this work, LA-ICP-MS was applied to study the distribution of copper and iron in human liver samples, which were collected by a liver biopsy of WD and control patients within a medical investigation. The analysis by LA-ICP-MS was performed with a 213 nm Nd:YAG laser using a spatial resolution of 10 μm and a scan rate of 20 μm/s. In a next step, copper and iron were quantified by LA-ICP-MS using homemade matrix-matched standards made of gelatin. Results showed an inhomogeneous copper and iron distribution in human liver with hotspots up to several thousand micrograms per gram liver within the hepatocytes.
Additionally, results for the elemental distribution in WD were validated by means of synchrotron radiation-based μXRF with a beam size of 4 μm at the BAMline at BESSYII (Helmholtz-Zentrum Berlin). Furthermore, XANES was performed to identify the present oxidation states of copper in WD, indicating a mixture of copper(I) and copper(II) within the liver tissue.
In the contemporary medicine, rhodanine staining is routinely used to determine the copper distribution in liver tissues. Nevertheless, this method does not provide results with a high sensitivity in comparison to LA-ICP-MS. Therefore, the presented LA-ICP-MS method offers a new possible diagnostic tool. These results may also contribute to a better understanding of Wilson´s disease and its development.
Airborne particulate matter is an issue of growing concern in industrialized countries.
Particles with diameters of less than 10 μm, in particular those with less 2.5 μm, are of special
concern, as they can enter the human lungs and contribute to various cardiovascular and
respiratory diseases. As the composition and health effects of airborne particles in urban, rural
and industrial outdoor air has been studied abundantly, our focus lies on the analysis of
airborne particle samples collected indoors, which may also have a significant effect on
human health, depending on the chemical composition of the particles and the chemical
bonding state, in which elements are present. This chemical speciation can be obtained using
X-ray absorption near edge structure (XANES) analysis, which requires a tunable excitation
source and therefore has to be carried out at synchrotron facilities. For this work, samples
were collected in office rooms of the Atominstitut building.
The BAMline at BESSYII, Berlin, features a double-multilayer monochromator (DMM) and a
double-crystal monochromator (DCM). The DCM offers an energy resolution E/ΔE of around
103, which makes it suitable for X-ray absorption fine structure (XAFS) applications. The
Atominstitut SR-TXRF vacuum chamber, formerly located at HASYLAB, Beamline L, is
now available at the BAMline. The chamber offers a sample changer for up to 8 quartz
carriers suitable for total reflection X-ray fluorescence analysis (TXRF) and was equipped
with a 30 mm² silicon drift detector (SDD). Aerosol samples were produced using a modified
three-stage Dekati™ impactor. For this work, only the coarse (2.5 to 10 μm, Stage 2) and the
fine particle fraction (1 to 2.5 μm, Stage 3), were of interest. XANES analysis was performed
for the elements Cr, Cu and Zn. Oxidation states of these 3 elements will be presented.
The X-ray Fluorescence beamline at ELETTRA operates in partnership with the IAEA an
ultra-high vacuum instrument with a 7-axis manipulator suitable for a variety of X-ray
analytical techniques, such as grazing incidence X-ray fluorescence analysis (GI-XRF),
TXRF, X-ray reflectometry (XRR) and XANES. Samples were produced using a four-stage
Sioutas Personal Cascade Impactor. With this impactor, it is possible to produce sizefractionated
samples down to the sub-μm range (Stages: A > 2.5 μm, B 1 to 2.5 μm, C 0.5 to
1 μm and D 0.25 to 0.5 μm). Direct sampling was performed on siliconized 25 mm Si wafers
suitable for TXRF. Cu-K edge SR-TXRF-XANES analysis was carried out for samples of all
impactor stages. Results of these experiments will be shown.
Airborne particulate matter is an issue of growing concern in industrialized countries. Particles with diameters of less than 10 μm (especially those smaller than 2.5 μm) can enter the human respiratory system and contribute to various diseases depending on their chemical composition and the chemical bonding state, in which elements are present. This chemical speciation can be obtained using X-ray absorption near-edge structure analysis (XANES), which requires a tunable excitation source and therefore has to be carried out at synchrotron facilities. Our special interest lies on the analysis of indoor airborne particulate matter, as particle composition and health effects of outdoor particles have been studied abundantly. For this work, samples were collected in various office rooms in the Atominstitut (ATI) building.
The BAMline at BESSYII features a double-multilayer monochromator (DMM) and a double-crystal monochromator (DCM). The DCM offers an energy resolution E/ΔE of around 103, which makes it suitable for XANES applications. The ATI SR-TXRF vacuum chamber, formerly located at HASYLAB, Beamline L, is now available at the BAMline. The chamber offers a sample changer for up to 8 quartz reflectors and a 30 mm² silicon drift detector (SDD) was used. Aerosol samples were produced using a modified three-stage Dekati™ impactor. For this work, only the coarse (2.5 to 10 μm) and the fine particle fraction (1 to 2.5 μm), were of interest. XANES results of Cr, Cu and Zn will be presented on this poster.
The X-ray Fluorescence beamline at ELETTRA operates in partnership with the IAEA an ultra-high vacuum instrument with a 7-axis manipulator suitable for a variety of X-ray analytical techniques, such as grazing incidence and total reflection X-ray fluorescence analysis (GI-XRF and TXRF), X-ray reflectometry (XRR) and XANES. Samples were produced using a four-stage Sioutas Personal Cascade Impactor. With this impactor, it is possible to produce size-fractionated samples down to the sub-μm range (Stages: A > 2.5 μm, B 1 to 2.5 μm, C 0.5 to 1 μm and D 0.25 to 0.5 μm). Direct sampling was performed on siliconized 25 mm Si wafers suitable for TXRF. Cu-K edge SR-TXRF-XANES analysis was carried out for samples of all impactor stages. Results of these experiments will be shown.