Präsentation
Filtern
Dokumenttyp
- Vortrag (568)
- Posterpräsentation (356)
- Zeitschriftenartikel (2)
Sprache
- Englisch (793)
- Deutsch (129)
- Mehrsprachig (4)
Schlagworte
- Fluorescence (75)
- Immunoassay (38)
- Nanoparticle (37)
- LIBS (33)
- Process Analytical Technology (33)
- Dye (29)
- Laser ablation (26)
- Metrology (26)
- PFAS (26)
- Quantum yield (26)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (926) (entfernen)
Communities worldwide face significant threats from Explosive Remnants of War (ERW), which endanger lives and restrict land usage. From forest fires due to ERWs or in ERW-contaminated areas (e.g., in Jüterbog, Germany) to broader global challenges (e.g., the Ukrainian conflict), the need for efficient detection and removal of these remnants, especially for humanitarian demining, is paramount. Traditional methods, like manual demining, have severe limitations in safety and efficiency. Here, we introduce an innovative solution to these challenges: “Chemosensing Smart Dust.” This technology uses chemoselective dyes that change their fluorescence properties when exposed to explosives like 2,4,6-trinitrotoluene (TNT). Fluorescence-based detection offers superior sensitivity, reduced likelihood of false positives, and enhanced accuracy of explosive detection. Drones, equipped with excitation lasers or LEDs, deploy the Chemosensing Smart Dust over areas of interest and actively detect the fluorescence changes using high-resolution cameras, offering a rapid, safe, and adaptable detection method. Beyond demining, this innovative approach has potential applications in monitoring polluted areas, homeland security, and emergency response.
Climate and air quality are of fundamental interest worldwide.
Gas metrology provides profound solutions to measurement tasks on climate and air quality, e.g., when greenhouse gases or pollutants are to be quantified.
Metrological capabilities are demonstrated through participation in the framework of the CIPM Mutual Recognition Arrangement (CIPM MRA).
In Germany, this is covered by three institutes: Bundesanstalt für Materialforschung und -prüfung (BAM), Physikalisch-Technische Bundesanstalt (PTB), and Umweltbundesamt (UBA).
Together, the three laboratories realize the unit mole by means of the national gas standards and offer services to their customers that are backed-up by internationally accepted calibration and measurement capabilities (CMCs).
SWIR luminescent nanomaterials – key chemical parameters for bright probes for in vivo bioimaging
(2024)
A current challenge for studying physio-pathological phenomena and diseaserelated processes in living organisms with non-invasive optical bioimaging is the development of bright optical reporters that enable deep tissue penetration, a high detection sensitivity, and a high spatial and temporal resolution. The focus of this project are nanomaterials, which absorb and emit in the shortwave infrared (SWIR) between ~900–2500 nm where scattering, absorption, and autofluorescence of the tissue are strongly reduced compared to the visible and NIR.
Metabolomics
(2024)
Oxidative degradation processes of tetrabromobisphenol A (TBBPA), a brominated flame retardant (BFR) in wood, plastics and electronics, were investigated by electrochemistry (EC) coupled online to electrospray ionization mass spectrometry (ESI/MS). Oxidative phase I and II metabolites production was achieved using an electrochemical flow-through cell equipped with a boron doped diamond electrode. Structural elucidation and prediction of oxidative metabolism pathways of TBBPA according to type II ipso-substitution were based on retention time, m/z ratio in negative mode and fragmentation pattern. Using the data obtained through high resolution MS analysis and the identification of single electron transfer (SET) as the initial step of a two-electron oxidation provided the necessary information to propose a mechanism for the electrochemical oxidation of TBBPA. Oxidation reactions involving aromatic hydroxylation and β-scission were the main degradation observed when studying the electrochemical behavior of TBBPA. Computational chemistry experiments using density functional theory (DFT) allowed to identify mono-hydroxylated reaction intermediate and dismissed the mechanism involving two concurrent hydroxylation. TBBPA oxidation products were compared to known metabolites of its biological and environmental degradation confirming the ability of electrochemistry to simulate β-scission reactions.
Der Vortrag beschreibt den Stand der Arbeiten an der BAM, Fachbereich Umweltanalytik zur Entwicklung von Sensoren für die Wasseranalytik. Er stellt die bisherigen Arbeiten da, die ausgehend von ELISAs, zunehmend portable Plattformen wie FPIA und LFIA umfassen. Beas-based Formate werden von mikrotiterplatten-basierten Techniken auf mikrofluidische Lab-on-Chip-Systeme übertragen, die bei geeigneter Miniaturisierung und Automatisierung als Sensorsysteme angesehen werden können. Der Vortrag endet mit einem Blick auf ein laufendes Monitoring-Projekt von anthropogenen Markern in Abwasser und charakterisiert die Treiber, die die Entwicklung von Sensoren für die Wasseranalytik in den letzten Jahren vorantreiben.
This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, micro reactions, pump and probe diagnostics, tomography,
temporal and spatial resolution. Basis of plasma computer modeling will be presented.
An overview of personal experience with laser-induced plasma (LIP) will be given. The combination of LIP with laser-induced fluorescence, atomic absorption, Raman spectroscopy and spatial heterodyne spectroscopy for elemental and isotopic analysis will be discussed. Unusual applications of LIP will be covered, such as LIP-based lasers and LIP-based chemical reactors.
In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. VOC in combination may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. Emission concentrations can become further elevated in new or refurbished buildings where the rate of air exchange with fresh ambient air may be limited due to improved energy saving aspects. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use (building) materials proved to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable emission reference materials (ERM). For the emission test chamber procedure according to EN 16516, no artificial ERM is commercially available. The EU-funded EMPIR project MetrIAQ aims to fill this gap by developing new and improved ERMs. The goal is to obtain a material with a reproducible and temporally constant compound release (less than 10 % variability over 14 days). Two approaches were tested: the impregnation of porous materials with VOC, and the encapsulation of VOC in polymer microcapsules. Impregnation is performed with help of an autoclave and supercritical CO2. The encapsulation is done by interfacial polymerisation on VOC droplets. For both approaches, synthesis and/or material parameters were varied to obtain an optimal ERM. Findings about the optimisation of ERM generation, as well as performance of the best emission reference materials, will be presented.
Optical biosensors often show remarkable performance and can be configured in many ways for sensitive, selective, and rapid measurements. However, the high-quality and advanced optical assemblies required to read out the sensor signals, for example, Total Internal Reflection Fluorescence (TIRF) or Supercritical Angle Fluorescence (SAF) microscopy, which necessitate complex and expensive optical elements. Particularly in optical method development, researchers or developers are often confronted with limitations because conventional manufacturing processes for optical elements can be restrictive in terms of design, material, time, and cost. Modern and high-resolution 3D printing techniques make it possible to overcome these challenges and enable the fabrication of individualized and personalized free-form optical components, which can reduce costs and significantly shorten the prototyping timeline—from months to hours. In this work, we use a modern, high-resolution (< 22 µm) commercial Liquid Crystal Display (LCD)-based 3D printer, for which we spectroscopically and physically characterized commercial photo-resins printable with the LCD technique in the first step (Figure 1). The aim was not only to produce a printed element with a high surface quality that mitigates the inner filter effects caused by attenuation (high optical density (OD) due to reflection and scattering), but also to select a material with a high refractive index (RI>1.5) and high transmission values (>90% transmittance) in the visible to near-infrared spectral range (approx. 450 – 900 nm) that exhibits little or no autofluorescence. Using a selection of suitable resins, lenses and free-form optical elements were manufactured for comparison with standard glass or plastic counterparts.