This contribution provides an overview of the BAMline synchrotron radiation beamline, which specializes in hard X-ray spectroscopy techniques for materials research. The BAMline offers X-ray absorption spectroscopy (XAS), x-ray fluorescence spectroscopy (XRF), and tomography to study materials' electronic structure, chemical composition, and structure. Key capabilities include standard and dispersive XAS for electronic structure, micro-XRF for elemental mapping, coded aperture imaging, and depth-resolved grazing exit XAS. The BAMline enables in situ characterization during materials synthesis and functions for energy, catalysis, corrosion, biology, and cultural heritage applications.
Ongoing developments like the implementation of machine learning techniques for experiment optimization and data analysis will be discussed. For instance, Bayesian optimization is being used to improve beamline alignment and scanning. An outlook to the future, where the BAMline will continue pioneering dynamic and multi-scale characterization, aided by advanced data science methods, to provide unique insights into materials research, will be given.
Time is the most valuable parameter in synchrotron experiments. This is costly and some of the experiments suffer from low efficiency due to low counting statistics. With today's high processing power long experiments are run in a shorter time and increase efficiency. With optimization algorithms time in "counting-hungry" experiments reduced by factor of 10. Our project is to develop a new method to analyze the chemical properties of complex materials non-destructively and efficiently, such as high entropy materials subjected to corrosion processes. A better understanding of the corrosion process will help to develop corrosion-resistant materials and reduce the cost of corrosion damage, which averages around 2.5 trillion USD annually.
The components that are used in structural and in high temperature applications generally face significant challenges with respect to oxidation behaviours and metalworking processes. In most of the cases, harsh environmental conditions lead materials to degrade due to corrosion. To thoroughly investigate the corrosion processes and to determine oxidation states of metal components within the reaction products, we need special analytical tools. Grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect this information in sub-micrometre depth range.
In order to obtain structural information, such as regarding oxidation states or atomic/molecular geometric arrangement, the GEXRF approach can also be combined with the X-ray absorption spectroscopy (XAS) method. The position and energy sensitive detector, with 264x264 pixel detector area, provides information regarding the signal emitted from the sample as a function of the emission angle and thus allows depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which can be controlled with a resolution of 0.5 eV provides XANES data to determine oxidation states.
We address the feasibility of our setup and provide a new optimization procedure (Bayesian Optimization and Gaussian Regression) to decrease measuring time. The results settle on a conceptual study on a reference sample (Cr-Oxide layer (300nm) on Cr layer (500nm) on Si wafer).
The components that are used in structural and in high temperature applications generally face significant challenges with respect to oxidation behaviours and metalworking processes. In most of the cases, harsh environmental conditions lead materials to degrade due to corrosion. To thoroughly investigate the corrosion processes and to determine oxidation states of metal components within the reaction products, we need special analytical tools. Grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect this information in sub-micrometre depth range.
In order to obtain structural information, such as regarding oxidation states or atomic/molecular geometric arrangement, the GEXRF approach can also be combined with the X-ray absorption spectroscopy (XAS) method. The position and energy sensitive detector, with 264x264 pixel detector area, provides information regarding the signal emitted from the sample as a function of the emission angle and thus allows depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which can be controlled with a resolution of 0.5 eV provides XANES data to determine oxidation states.
We address the feasibility of our setup and provide a new optimization procedure (Bayesian Optimization and Gaussian Regression) to decrease measuring time. The results settle on a conceptual study on a reference sample (Cr-Oxide layer (300nm) on Cr layer (500nm) on Si wafer).
Compositionally complex alloys (CCAs) are a new class of alloys containing at least 5 elements with concentrations between 5 and 35 atomic percent. Due to their adjustable composition, which enables modifications of mechanical properties (such as hardness, strength and ductility etc) and their stability at high temperatures, CCAs have been the focus of various studies [1,2]. Especially the corrosion behavior of CCAs has been a wide research interest.
However, there are only few studies that deals with the degradation process on such materials, which is highly relevant for the safety aspect for future component design. To thoroughly investigate the corrosion processes and to determine oxidation states of metal components within the reaction products, we need special analytical tools. Since the grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect notable information regarding the high temperature oxidation, we consider it as a useful method to investigate how CCAs behave in corrosive environments.
The main idea of grazing geometry is to enhance the fluorescence signal of the surface. This enables highly sensitive surface analyses of thin protective film on surface in sub-micrometer scale [3]. When compared to a conventional CCD-based camera, the advantage and most important feature of the detector system (Color X-Ray Camera (CXC)) is that each pixel is an energy sensitive detector. The position and area sensitive detector, with 264x264 pixel detector area, provides information regarding the signal emitted from the sample as a function of the emission angle and thus allows depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which can be controlled with a resolution of 0.5 eV provides XANES data to determine oxidation states.
In this contribution, we address the feasibility of our setup and new optimization procedure (Bayesian Optimization and Gaussian Regression). The results of a conceptual study regarding layer properties of the reference sample (Cr-Oxide layer (300nm) on Cr layer (500nm) on Si wafer) and CrCoNi (Cr-Oxide (>1µm) layer on CrCoNi substrate) medium entropy alloy.
High entropy alloys (HEAs) are considered as a new class of alloys containing at least 5 elements with concentrations between 5 and 35 atomic percent. There has been a growing interest in HEAs in the material research field in recent years. Due to their adjustable composition, which enables the modifications of mechanical properties (such as hardness, strength and ductility etc) and their stability at high temperatures, HEAs have been the focus of various studies.
Especially the corrosion behavior of HEAs has been a wide research interest. Since the grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect notable information regarding the high temperature oxidation, we consider it as a useful method to investigate how HEAs behave in corrosive environments.
The main idea of grazing geometry is to enhance the fluorescence signal of the surface. This enables highly sensitive surface analyses of thin protective film on surface in sub-micrometer scale. Position-sensitive area detectors provide information regarding the signal emitted from the sample as a function of emission angle and thus allow depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which lays within a specific energy range provides XANES data to determine oxidation states. Moreover, since GEXRF profiles can also be simulated through physical models (Urbach 1999), they enable us to determine the layer thickness of a given sample in a non-destructive way.
In this contribution, we present the preliminary results of a conceptual study regarding layer properties of CrCoNi medium entropy alloy. The successful implementation of such methodological concept will pave the way for the investigation of more complex alloys with multiple layers, which is planned for the later phases of the project.
High entropy alloys (HEAs) are considered as a new class of alloys containing at least 5 elements with concentrations between 5 and 35 atomic percent. There has been a growing interest in HEAs in the material research field in recent years. Due to their adjustable composition, which enables the modifications of mechanical properties (such as hardness, strength and ductility etc) and their stability at high temperatures, HEAs have been the focus of various studies.
Especially the corrosion behavior of HEAs has been a wide research interest. Since the grazing exit X-ray fluorescence (GEXRF) offers a non-destructive way to collect notable information regarding the high temperature oxidation, we consider it as a useful method to investigate how HEAs behave in corrosive environments.
The main idea of grazing geometry is to enhance the fluorescence signal of the surface. This enables highly sensitive surface analyses of thin protective film on surface in sub-micrometer scale. Position-sensitive area detectors provide information regarding the signal emitted from the sample as a function of emission angle and thus allow depth-sensitive analysis. Furthermore, the data collected from samples of an incidence energy which lays within a specific energy range provides XANES data to determine oxidation states. Moreover, since GEXRF profiles can also be simulated through physical models (Urbach 1999), they enable us to determine the layer thickness of a given sample in a non-destructive way.
In this contribution, we present the preliminary results of a conceptual study regarding layer properties of CrCoNi medium entropy alloy. The successful implementation of such methodological concept will pave the way for the investigation of more complex alloys with multiple layers, which is planned for the later phases of the project.
Polymer electrolyte membranes (PEM) are polymers which act as separator in an electrochemical cell and allow ionic charge flow to close the circuit. Widely used membranes are perfluorinated sulfonic-acid (PFSA) ionomers (e.g. Nafion™), a class of ion-conducting polymers with remarkable ion conductivity and chemical-mechanical stability. A nanoscopic water system around the sulfonic acid capped side-chains of the otherwise hydrophobic polymer allows the ion transport. Only approx. 14 molecules of water per sulfonic group are present in the fully hydrated state. In vanadium redox flow batteries (VRFB) ideally only protons are transported. The weak ion selectivity of Nafion™ is the main cause for the transportation of vanadium, briefly vanadium crossover, in VRFBs a system we have investigated more closely, lately. The consequences of crossover are a concentration imbalance and a self-discharge of the battery, which leads to a decrease of the capacity. The development of efficient energy storage systems is crucial for the transformation towards a renewable energy based economy. The VRFB has a great potential as a commercial electrochemical energy storage system due to properties including, but not limited to, no cross-contamination, a long cycle-life and a theoretically unlimited capacity. VRFB consists of two half-cells, which are linked to electrolyte tanks and separated by a membrane. The membrane plays a major role in overall cell performance. So far, vanadium transportation models, which include diffusion, migration, electroosmotic convection and pressure gradients, are inconsistent. There is no agreement in the literature on the diffusion coefficients of vanadium species (e.g. published diffusion coefficients of V2+ are located between 3.13·10-12 m²s-1 and 9.44·10-12 m²s-1) indicate that thevanadium crossover is not well understood and there is a lack on a more fundamental level. Since the membrane transport is the rate-determining step of the crossover as well as of the proton exchange it is extremely important to understand these phenomena on a fundamental level. This will eventually allow us to design better membranes. Alternative materials need to show equivalent performance compared with Nafion™ and ideally be more selective regarding ion cross-membrane transport.There are several options to approach the chemistry i.e. the interaction of dissolved and bound ions inside the confined water body of ionomeric membranes. Vanadium ions are a versatile model as UV/VIS data can be used to distinguish between the 5 species V2+, V3+, VO2+, VO2+ and V2O33+ of the electrolyte. Infrared spectroscopy has been applied to study the interaction of sulfonic groups and the ions. Molecular dynamic modeling is another approach to study the distribution and distances of ions. We now introduce X-ray absorption near edge structure spectroscopy (XANES) to study species and species changes inside Nafion™ and a novel membrane based on poly(1,1-difluoroethylene) (PVDF). We evaluated the methods and investigated the influence of irradiation, temperature and hydration on the measurements.
Vanadium redoxflow batteries (VRFB)are currently one of the most promising candidates for stationary energys torage.For large scale applications the ion conducting membranes currently in use need to be improved. Ideally,they need to become more cost efficient and selective regarding the vanadium crossover.For a better understanding of the vanadium crossover, the development of reliable analytical methods and procedures, that elucidate uptake and transport of vanadium ions in the membrane, is necessary. First, we present the uptake of V2+,V3+,VO2+, VO2+ and V2O33+ in Nafion™ and in a novel membrane based onpoly(1,1-difluoroethylene)(PVDF). In preliminary discharge/charge experiments the ETFE-based membrane, the precursor of PVDF-based membrane, performed comparable to Nafion™. The methods of choice for speciation are UV/Vis and X-ray absorption near edge structure spectroscopy (XANES). According to the results, V2O33+, formed from VO2+ and VO2+, diffuses also into the membrane. In present models, the diffusion of V2O33+ is neglected. In addition,we study whether reactions could take place inside the membranes’ nanoscopic water body using XANES. Exposing Nafion™ from one site with V3+a nd from the other site with VO2+ realized the experiment. The results verified that VO2+ was formed inside the membrane. However,in present models reactions inside the membrane are neglected, too.