Präsentation
Filtern
Dokumenttyp
- Vortrag (409)
- Posterpräsentation (84)
- Beitrag zu einem Tagungsband (9)
Sprache
- Englisch (326)
- Deutsch (175)
- Mehrsprachig (1)
Schlagworte
- Safety (26)
- Hydrogen (24)
- Gefahrgut (21)
- Gefahrguttransport (21)
- Ageing (20)
- Gefahrgutverpackungen (18)
- Wasserstoff (18)
- Transport (17)
- Drop test (15)
- Dangerous Goods Database (14)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (502) (entfernen)
Biofuels, particularly biodiesel, have gained significant attention as an alternative to traditional fossil fuels in recent years. Unlike diesel, which contains hundreds of compounds, biodiesel only contains a few compounds in the C16-C18 carbon chain. However, the use of biodiesel in automobile and transportation applications can result in problems of degradation or even damage in materials. Among the commonly used polymer materials, fluorocarbon (FKM) shows excellent performance and high stability and compatibility towards oil, diesel, ethanol, and other chemicals. FKM is a family of fluorocarbon-based fluoroelastomer materials, which provide excellent high-temperature and chemical stability compared to other elastomers. As a result, FKM is widely used in chemical processes such as petroleum refining, where it is used for sealings, pumps, and other components.
Im Rahmen der von der BAM und anderen Partnern ins Leben gerufenen Initiative „Digitale Qualitätsinfrastruktur“ liegt der Fokus u.a. auf der Entwicklung von neuen Zertifizierungsworkflows. Dabei ist eine besondere Bedeutung dem Zusammenführen von Operational Technology (OT) und Informationstechnik (IT) beizumessen. Zur Datenintegration aus der Sensor-Feldebene einer Versuchs-wasserstofftankstelle wurde eine solche Infrastruktur zunächst in einer Laborumgebung aufgebaut.
Die Umweltwirkungen auf ein Material werden als Überlapp der Funktionskurven von Materialempfindlichkeit und einwirkenden Umweltparametern betrachtet. Wenn entweder die Empfindlichkeit oder die Beanspruchungen Null sind, ergibt sich auch keine Umweltwirkung und bei beidseitig Werten größer Null das jeweilige Produkt der beiden. Die Akkumulation der nicht-reversiblen Effekte über die Zeit und allen Eigenschaftsänderungen entspricht der Alterung des Materials für den jeweiligen Expositionszeitraum.
Die digitale Umweltsimulation gliedert sich hier in drei Teilaspekte. Ein erster, rein materialwissenschaftlicher Teil hat die Aufgabe, alle relevanten Materialempfindlichkeiten experimentell zu quantifizieren. Ein zweiter – unter Umständen numerischer Teil – hat die Aufgabe, das Bauteil und seine Einbaulage zu digitalisieren und aus den makroskopischen Umgebungsbedingungen die relevanten mikroklimatischen Umweltparameter für alle Oberflächen- oder Volumenelemente zu bestimmen. In einem dritten Teil werden die Einwirkungen über den betrachteten Zeitraum berechnet und kumuliert. Dieses Konzept, das auf den so genannten Expositions-Reaktions-Funktionen (ERF) basiert, wird an Beispielen der Photoxidation erläutert. Dieses Vorgehen wurde schon beim ViPQuali-Projekt als Numerische Umweltsimulation umgesetzt.
Überprüft werden muss das Modell unbedingt an einer realitätsnahen Validierungsbeanspruchung. Hier werden die ermittelten ERFs mit über den kompletten Beanspruchungszeitraum geloggten Umweltparametern gekoppelt, um die berechnete mit der experimentell erfahrenen Alterungswirkung zu vergleichen. Nur so kann sichergestellt sein, dass alle für die Anwendungsumgebung relevanten Materialempfindlichkeiten einbezogen wurden.
Evaluation of Heat Fluxes in Fire Reference Test Conducted in BAM Propane Gas Fire Test Facility
(2024)
Packages for the transport of intermediate- and high-level radioactive waste are designed to withstand severe accidents. The International Atomic Energy Agency (IAEA) has established specific mechanical and thermal tests. Packages for the transport of radioactive material must withstand these tests to comply with the Regulations for the Safe Transport of Radioactive Materials IAEA [IAEA (2018)]. A fire reference package was developed with the primary objective to demonstrate that the fire meets the regulatory requirements. Another aim is to characterise the boundary conditions of the actual fire as input parameters for thermo-mechanical simulations. A simple method to characterise the boundary conditions of a real steady state fire with a fire reference package is presented. The thermal test mainly consists of a 30 minute fully engulfing 800°C pool fire or an equally severe fire, such as a propane gas fire. The fire reference tests are performed prior to the actual fire test with the real package. The heat fluxes into the package depend substantially on the fire characteristics and the surface temperature of the package. To investigate local and overall heat fluxes over a wide range of surface temperatures in this test facility a fire reference package was designed for repeated use. The fire reference package presented in this paper represents the outer geometry of a small transport container for radioactive material and is used as a device in civil engineering. It is designed as a closed steel sheet cylinder with a wall thickness of 10 mm, a length of 182 mm and a diameter of 102 mm. The package was instrumented with thermocouples and filled with heat resistant insulation material. Open-air fire tests were performed in a BAM propane gas fire test facility with the fire reference package. The measured temperatures are used to determine the changes of heat fluxes into the fire reference package in relation to the package surface temperature. The calculated heat fluxes allow its fitting to express the thermal exposure as simple mathematical boundary condition. Therefore, in a first approach, fire properties such as adiabatic surface temperature (AST) as proposed by Wickström et al. (2007), convection coefficient and emissivity are determined mathematically fitting the heat flux development presented in this paper. The evaluated results provide an initial picture of local fire characteristics of the conducted propane gas fire and are a further development of previous works from Feldkamp et al. (2020). The results can be used in thermal and thermo-mechanical models to simulate the load on the real transport package in fire. The test shows that the examined propane gas fire covers the IAEA-fire over a wide range of surface temperatures with the chosen test stand parameters.
The ongoing geo-political conflicts and the increasing need for the implementation of measures to improve the energetic system sustainability are increasing the importance of tanks for storing cryogenic fluids in the energy industry. The most common example of cryogenic tank applications is the transport of natural gas and hydrogen in their liquid form (LNG and LH2 respectively) for which, considering the same transport volume cryogenic storage ensures significantly higher transport capacities with respect storage based solely on overpressure.
A common feature of all cryogenic transported fluids is that their condition must be maintained minimizing heat leaks from the environment as much as possible. This is achieved by the implementation of thermal super Insulations (TSI) systems based on e. g. rock wool, perlites, microspheres, multilayer insulations (MLI), and vacuum which have proven to be effective in applications. However, due to the relatively short period of use in some applications, the small number of documented incidents, and the still few investigations carried out in the field, the exploitation of such systems in the cryogenic fluids transport sector still suffers from insufficient knowledge about the course and consequences of incidents. Accidents involving collisions, fires, and their combination are quite common in the transportation sector and may generate extraordinary loads on the tank and its insulation system, eventually leading to tank failure.
The present study focuses on the behavior of TSI systems in tanks when it is exposed to an external heat source representative of a hydrocarbon fire scenario. This may cause an increase of the heat flux into a tank by several orders of magnitude with respect to normal design conditions, thus inducing severe and in the TSI, causing the rapid release of flammable gas and even resulting in a Boiling Liquide Expanding Vapour Explosion (BLEVE).
To study such scenarios a test rig was developed at BAM that allows testing of TSI at industrial conditions and enables subsequent analysis of TSI samples. This test rig considers the typical double-walled design of tanks for cryogenic fluids with vacuum and an additional insulating material in the interspace. Adjustable electrical heating elements simulate the fire on one side of the double wall. This process allows the implementation of repeatable heat loads of up to 100 kW/m². The other side of the double wall is represented by a fluid-supported heat exchanger, which allows the simulation of cold or cryogenic conditions in the test rig, and to determine the heat flux transmitted through the double wall. Thus, the test rig allows thermal loading and performance analysis of TSI samples at the same time.
In the presentation, the results of diverse tested TSI systems will be presented and discussed. As a result of this study, the list of advantages and disadvantages for the choice of tested TSI expands. Within the test, all samples degraded as a consequence of a hydrocarbon fire-orientated thermal load. Strong differences in the behavior of the tested TSI systems over temperature, location, and time were observed. Additionally, the tested MLI insulations were significantly more resistant to their base materials. These results are relevant for the design, the definition of national and international regulations, the Risk assessment, and the development of safety concepts for cryogenic tanks.
Der Wasserstofftransport auf der Straße ist wichtig und wird wie der noch geringe Transport auf der Schiene weiter stark zunehmen. Die bisherige Effizienzsteigerungen sind über Werkstoff- und Designänderungen vom Vollstahl über umfangsumwickelte Stahl- bis zu Compositespeichern mit Kunststofflinern erfolgt.
Hinzu kam die auf Basis der BAM-GGR 022 an Vorbedingungen geknüpfte Prüffristverlängerung von 5 auf 10 Jahre. Die wiederkehrende Prüfung von großen Transporteinheiten bedeutet jedes Mal einen Stillstand von gut 8 Wochen. Entsprechend steht mit Blick auf die weitere Effizienzsteigerung die Reduktion des Prüfaufwands im Fokus.
Eine Effizienzsteigerung kann nach aktueller Rechtslage geschehen, indem die hydraulische Prüfung auf eine Gasdruckprüfung umgestellt wird. Dies könnte zukünftig mit geeigneten Arbeitsschutzmaßnahmen pneumatisch durchgeführt werden – auch ohne Rechtsänderung.
Ein deutlich größerer Schritt in Richtung Verbesserung des Aufwands- zu Nutzenverhältnis ließe sich erreichen, indem die zerstörungsfreie Prüfung nicht mehr nur als Arbeitsschutz-motiviertes, begleitendes, sondern als zentrales Prüfverfahren ausgebaut wird. Gerade wenn – wie für die Schallemissionsanalyse erwartet – eine relativ gute Abschätzung des Berstdruckes möglich ist, könnte auf die 100%-Prüfung verzichtet werden und bis zu einem kritischen Alter nur auf Stichprobenprüfung basieren, was allerdings erhebliche Rechtsänderung erfordert und auch neue Werkezuge der Informationsverwaltung.
Als Vorlage für einen praktischen Ansatz zur Rechtsänderungen inkl. Informationsverwaltung wird auf die SV 674 in Verbindung mit 6.2.3.5.3ff ADR/RID verwiesen. Dies kombiniert mit einer digitalen Lebenslaufakte, die auf der digitalen Qualitätssicherung (QI-digital) beruht, wäre ein mächtiges Werkzeug für eine Verbesserung des Aufwands- zu Nutzenverhältnis und so auch eine Lösung des mit der stark steigenden Anzahl der Transporteinheiten absehbaren Kapazitätsproblems in der wiederkehrenden Prüfung.