Due to the ageing of the infrastructure facilities, a reliable assessment of the condition of concrete structures is of great interest to plan timely and appropriate measures. In concrete structures, pittingcorrosion of the reinforcement is the predominant deterioration mechanism affecting serviceability and eventually structural performance. Determination of quantitative chloride ingress is not only necessary to obtain valuable information on the current condition of a structure, but the data obtained can also be used to predict future developments and the associated risks. An overview of the progress and the possibilities of the application of laser-induced breakdown spectroscopy for concrete analysis in daily civil engineering practice is given. High-resolution 2D measurements of drill cores to determine the penetration of harmful species into concrete is presented. Furthermore, the application of a mobile LIBS system in a parking garage is shown. The system consists of a diode-pumped low-energy laser (3 mJ, 1.5 ns, 100 Hz) and a compact NIR spectrometer. A scanner allows two-dimensional element mapping. Progress towards the establishment of LIBS in a leaflet for the analysis of chlorine ingress into concrete in civil engineering is presented.
In civil engineering, clear regulations and standards, such as the European standard DIN EN 206 apply to ensure that the existing infrastructure is sufficiently resistant to a wide range of exposure conditions. Despite these regulations, in practice concrete structures often show severe damage during their service life. One of these damages is pitting corrosion of the reinforcement, which can be caused by chloride ingress into the structure. Therefore, determining the distribution and depth of chloride ingress is important in predicting the service life. LIBS provides an alternative method to conventional wet chemistry in civil engineering. Despite many advantages, the use of LIBS has been severely limited due to a lack of regulations. Together with project partners from research and industry, we are currently working on a leaflet that will regulate chloride analysis in civil engineering using LIBS. This year, an international round robin test was organized to evaluate the performance of LIBS for chloride analysis in cement pastes. No specifications were given for the experimental LIBS setup and data evaluation. The preliminary results are presented.
Erstellung von Tiefenprofilen auf Schweißnähten mittels Laserinduzierter plasmaspektroskopie (LIPS)
(2021)
Duplexstähle sind hochlegierte, nichtrostende Stähle. Sie bieten aufgrund des ausgewogenen Phasenverhältnisses von Austenit und Ferrit einige physikalische Vorteile gegenüber anderen nichtrostenden Stählen. Beim Schweißen können sich durch die Kondensation von Schweißrauch und verdampftem Material verschiedene chemische Elemente auf der Oberfläche der erstarrten Schweißnaht anreichern. Dann ist die Bildung einer schützenden Chromoxidschicht nicht mehr gewährleistet und es kann an diesen Stellen zu Lochfraß kommen. Frühere Arbeiten haben gezeigt, dass die Anreicherung von Mangan und Chrom an der Oberfläche der Wärmeeinflusszone des geschweißten Edelstahls 304L mit LIBS gemessen werden kann. Wir stellen die Ergebnisse der Optimierung der LIBS-Parameter für präzise Dickenmessungen solcher dünnen Schichten und für Tiefenprofilmessungen vor. Dazu haben wir galvanisch beschichtete Kupferproben mit bekannten Schichtdicken verwendet. Die Mangankonzentration im Schweißgut ist reduziert. Dies hat einen großen Einfluss auf die metallografische Struktur des Materials.
Duplex steels are high-alloyed, stainless steels. They offer some physical advantages over other stainless steels due to the balanced phase ratio of austenite and ferrite. During welding processes, when welding fumes and vaporized material condensates, different chemical elements can accumulate on the surface of the solidified weld. Then, the formation of a protective chromium oxide layer is no longer guaranteed and pitting corrosion can occur at these places. Previous work has shown that the accumulation of manganese and chromium on the surface of the heat-affected zone of the welded high-grade steel 304L can be measured by LIBS.
We present the results of the optimization of LIBS parameters for precise thickness measurements of such thin films and for depth profile measurements Therefore, we used galvanically coated copper samples with known film thicknesses. The Concentration of manganese is reduced in the weld metal. This has a high impact on the metallografic structure of the material.
Welding processes of duplex stainless steels cause an unbalanced austenite (γ)/ferrite (δ) ratio due to high cooling rates and changes in chemical composition. That causes a degradation of mechanical properties and corrosion resistance. In situ monitoring of the weld pool is to be realized with the help of laser-induced breakdown spectroscopy (LIBS). A major advantage of this technique is the highly accurate time and spatially resolved measurement of the chemical composition during welding. Previous research has established that the LIBS method is suitable to detect chemical elements during welding and to show a distribution of selected elements. Chemical composition in the WM and HAZ can now be quantified using calibration curves generated by certified reference materials (CRM). Furthermore, a cooling rate can be plotted against the measured electron temperature.
Measurement of hydrogen concentration in steels by laser-induced breakdown spectroscopy (LIBS)
(2021)
Current efforts to achieve lightweight construction and the required reduction in CO2 emissions and an increase in energy and resource efficiency call for the increasing use of high-strength fine-grain structural steels. However, as the strength of higher-strength fine-grain structural steels increases, so do the associated joining challenges. Particular attention must be paid to hydrogen-assisted cold cracking. The influence of hydrogen reveals itself less in the strength but has a significant effect on the deformability [1, 2]. The degradation of the material properties can lead to zero ductility, where the values of the yield strengths coincide with the tensile strengths.
Laser-induced breakdown spectroscopy (LIBS) is a spectroscopic technique that can be used to determine elemental compositions without pre-treatment of the samples. Short, high-energy laser pulses ablate a small volume (< 0.1 mm3) of the examined material and ionize it to form a plasma. The decaying plasma emits element-specific light. This light is spectroscopically analysed and allows to detect qualitatively the present elements and to quantify them with help of a standardization routine. The simple experimental set-up and the fast, nearly non-destructive analysis procedure characterize the LIBS analysis. The LIBS method allows a time and spatially resolved in situ measurement of steel components in use.
Even low hydrogen concentrations (~ 1 wt.-ppm) in steel can be measured with the LIBS method and can be quantified with help of certified reference materials. The results are compared with results gained with the well-established carrier gas hot extraction method.
Schweißprozesse von nichtrostenden Duplexstählen verursachen aufgrund hoher Abkühlungsraten und Änderungen der chemischen Zusammensetzung ein unausgewogenes Austenit (γ)/Ferrit (δ)-Verhältnis. Das verursacht eine Degradation der mechanischen Eigenschaften und der Korrosionsbeständigkeit. Die In-situ-Überwachung des Schweißbades soll mit Hilfe der laserinduzierten Plasmaspektroskopie (LIPS) realisiert werden. Ein großer Vorteil dieser Technik ist die hochgenaue zeit- und ortsaufgelöste Messung der chemischen Zusammensetzung während des Schweißens. Bisherige Untersuchungen haben ergeben, dass die LIBS-Methode geeignet ist, chemische Elemente während des Schweißens zu detektieren und eine Verteilung ausgewählter Elemente aufzuzeigen. Chemische Zusammensetzungen können mit vorab erstellten Kalibrierkurven dargestellt weerden.
To conduct a reliable, repeatable and accurate LIBS analysis, the optimization of the experimental setup is an important task. Hardware parameters of lasers and spectrometers used in the setup as well as additionally required components such as optics or process gas pipes must be carefully aligned and adjusted because factors like (i) focal conditions of the optics, (ii) alignment of the sample, (iii) process purge gas (types, flow rate) or (iv) measurement settings (integration time, accumulation of pulses) have a big impact on the signal quality. Therefore, in most cases the effect of different factors is evaluated empirically due to changing one factor at a time while keeping the overall configuration the same. In the end, the optimal configuration is selected based on the best parameters for each influencing factor. During optimization, a configuration of the experimental setup is aimed at, which allows e.g. the highest signal intensity or the lowest variation. In most cases, cross-correlation, interference and interaction among the various factors are not considered. For this reason, the possibilities of using Design of Experiment (DoE) to optimize a LIBS experiment will be shown and advantages of (i) reduction of testing plans using a feature space, (ii) identifying and considering cross-correlations and interactions, (iii) evaluating individual impacts on the measurement (e.g. contour and surface plots) as well as (iv) multivariate models for prediction of impacts will be presented.