Präsentation
Filtern
Erscheinungsjahr
- 2018 (2)
Dokumenttyp
Sprache
- Englisch (2)
Referierte Publikation
- ja (2) (entfernen)
Schlagworte
- Containment (1)
- Leakage rate (1)
- Length of puncture bar (1)
- Mechanical assessment (1)
- Numerical simulation (1)
- Puncture bar test (1)
- Spent fuel (1)
- Transport of radioactive materials (1)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (2) (entfernen)
Numerical approach to determine the correct puncture bar length for the IAEA puncture bar drop test
(2018)
Among other mechanical tests the 1 meter drop onto a steel puncture bar shall be considered for accident safe packages for the transport of radioactive material. According with the IAEA regulations “the bar shall be of solid mild steel of circular section, 15.0 ± 0.5 cm in diameter and 20 cm long, unless a longer bar would cause greater damage…”. The most damaging puncture bar length can be estimated by iterative processes in numerical simulations. On the one hand, a sufficient puncture bar length has to guarantee that shock absorbers or other attachments do not prevent or reduce the local load application to the package, on the other hand, a longer and thus less stiff bar causes a smaller maximum contact force. The contrary influence of increasing puncture bar length and increasing effective drop height shall be taken into account if a shock absorber is directly placed in the target area. The paper presents a numerical approach to identify the bar length that causes maximum damage to the package. Using the example of two typical package masses the sensitivity of contact forces and puncture bar deformations to the initial length are calculated and assessed with regard to the international IAEA package safety requirements.
The containment systems of transport casks for spent fuel and high radioactive waste usually include bolted lids with metallic or elastomeric seals.
The mechanical and thermal loadings associated with the routine, normal and accident conditions of transport can have a significant effect on the leak tightness of such containment system.
Scaled cask models are often used for providing the required mechanical and thermal tests series. Leak tests have been conducted on those models.
It is also common practice to use scaled component tests to investigate the influence of deformations or displacements of the lids and the seals on the standard leakage rate as well as to study the temperature and time depending alteration of the seals.
In this paper questions of the transferability of scaled test results to the full size design of the containment system will be discussed.