The detection of delamination, rot, and cracks in wooden construction elements is a key task for nondestructive testing (NDT). Air-coupled ultrasound (ACU) is used to detect defects and damage without altering the structure permanently. Using through transmission it is possible to detect even small holes and missing adhesive. After interpretation of the inspection data, an assessment of the mechanical properties based on an appraisal of internal defects in the material is feasible. Novel ferroelectret transducers with a high signal-to-noise ratio (SNR) enable a high-precision structure recognition. The transducers made of cellular polypropylene (PP) are quite suitable for ACU testing due to their extremely low Young’s modulus and low density which result in a favorable acoustic impedance for the transmission of ultrasonic waves between the transducer and air. Thus, structures with great dimensions, thickness up to 300 mm and material densities under 500 kg/m³ can be inspected. Promising results were obtained under laboratory conditions with frequencies from 90 kHz to 200 kHz. The advantage of ACU transducers is that they do not require contact to the sample, are accurate, and cost effective. Ultrasonic quality assurance for wood is an important attempt to increase the acceptance of wooden structures and towards sustainability in civil engineering in general.
Even for the basic measurements of material data for design and engineering of composite structures there is a need to upgrade standards. With a new shear frame test rig more precise values can be obtained.
With advanced methods in the research on the fatigue behaviour of FRP it was found a load level of infinite life for GFRP and CFRP. This is in the range of typical strain values of airliners and rotor blades in normal operation.
Statistically the mean time between damage events on rotor blades is 6 years (Deutscher Windenergie Report 2006). Due to imperfection in the production the shell structures get cracks after a few years fare before the designed life time. A shell test rig was built at BAM for efficient research on the effects of defects in production.
Test blades of ~10m are an efficient way for SHM research and evaluation of NDT-methods and blade geometry.
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications.
To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
In general, wind turbines transform the kinetic energy of the wind into electric power. Thereby, the wind turbine blades are facing unsteady loads which are transferred to the hub to generate a rotation of the turbine’s axis. This brief introduction focuses on the aerodynamics of the blades and the corresponding loads. Starting with the basic flow field and loads of an airfoil, terms like stagnation point, boundary layer, Reynolds number, transition, and separation are introduced. For different geometries, lift and drag coefficient curves are discussed. Then, full wings will be considered, including their three-dimensional flow field due to wing tip vortices and crossflows. As a main source of increased loads, unsteady effects are explained in more detail such as gusts, tower passing, earth boundary layer crossing, free stream turbulences, yaw misalignment, etc. At the end, extra loads due to an oscillating free stream are introduced.
Non-Destructive Testing (NDT) is routinely used in aerospace, nuclear, railway and automotive industries. The most common use of NDT is to find flaws in components. In dynamically loaded components, flaws grow, and if they are not detected in time and no corrective measures are taken they can reach critical sizes. When a flaw reaches a critical size, it endangers the structural integrity of the component and will likely cause the component to fail. To detect flaws before they reach a critical size, components are inspected in fixed time intervals with non-destructive testing systems. In order to determine the amount of time between inspections, three variables are necessary: the critical size of the flaw, the flaw propagation speed and the size of the flaw that can be reliably detected by NDT. All three variables are, to a certain extent, stochastic. The critical size of the flaw and flaw propagation speed are questions of fracture mechanics. The size of the flaw that can be reliably detected by NDT is predicted by POD curves. The POD is determined for a given inspection scenario. The inspection scenario includes the NDT system, the component geometry and the type of the flaw. If one of these changes, the POD will also change and needs to be recalculated. As a result, the design of a dynamically loaded safety-relevant components is an iterative process in which a geometry is sought that provides an optimum between structural integrity and inspectability. A model that describes the iterative process for the design of the safe components with examples from praxis will be presented.
Foundations
(2018)
Validation of artificial defects for Non-destructive testing measurements on a reference structure
(2018)
Non-destructive testing was established over the last decades as an important tool for assessing damages, material characterization and quality assurance in civil engineering. For example, Ground Penetrating Radar (GPR) can be used to scan large areas of concrete structures to determine the spatial position of the reinforcement. With the ultrasonic echo method, the thickness of concrete structures can be easily determined even if a high density of reinforcement is given. Various methods and processes have been developed for the validation of NDT procedures aiming at ensuring the quality of measurements in practical use. The Probability of Detection (POD) for example, is an available method to compare different technical devices with each other quantitatively regarding their performance. With this method, the best suited testing device for a specific inspection task under defined boundary conditions can be selected. By using the Guide to the Expression of Uncertainty in Measurement (GUM), it is possible to quantify the measurement uncertainty of an inspection procedure for a specific task. Another important aspect to improve the acceptance of non-destructive testing methods is the development of reference specimens.
Reference specimens serve for the calibration and further development of NDT methods under realistic conditions in different laboratories under the same conditions. This is an essential prerequisite for round robin tests. A particular challenge here is the most realistic representation of a damage that can occur at building sites. Possible damages include for example horizontal and vertical cracks or honeycombs in concrete. Such a reference structure was built for the development of a new design of power plant constructions. Comparative studies on the manufacturing of realistic honeycombs and delaminations were carried out in advance on a test specimen. The results of this study are presented here.
Corrosion of concrete reinforcement is one of the major damage mechanisms affecting both the load-bearing capacity and the serviceability of reinforced concrete structures significantly. The challenge of detecting corrosion is that the corrosion process in its various forms is not immediately visible, especially in the corrosion initiation phase inside the concrete. When externally discernible damages are observed during visual inspections on the structure, the extent of the damage inside the concrete is often already significant. Corrosion caused by carbonation often leads to severe discoloration of the surface or even large-area spalling of the concrete cover. In contrast, chloride-induced corrosion is usually difficult to observe visually, but can cause much more serious damage in less time. The effect occurs locally and can lead to weakening of the cross-section of the reinforcement. This, in turn, can cause sudden structural collapses without prior notice. Therefore, it is important to investigate whether there is protection against corrosion of the reinforcement in the concrete and to detect active corrosion in the structure at an early stage.
In the meanwhile, various non-destructive and minimally invasive testing methods are available to evaluate the resistance to penetration of corrosion-promoting pollutants and to detect active corrosion. In this paper, a bridge crossing the river Regen (Germany) is used as a case-study to demonstrate how the information obtained applying different testing methods can be combined and evaluated in the context of structural reassessments. Both the results of the permeability testing (Torrent tester) and the electrical resistance measurement (Wenner probe) are considered, as well as active corrosion areas are localized using the half-cell potential mapping combined with the concrete cover measurement with the eddy current method and ground penetrating radar (GPR). The results are evaluated using drill cores and in addition laser-induced breakdown spectroscopy (LIBS) was applied to obtain information about possible ion transport in the concrete.
The permanently increasing number of wind turbines requires suited inspection and monitoring methods to ensure liability and security. Concerning the inspection of ro-tor blades, only manual inspections are state of the art. Thermographic Testing (TT) has the potential to detect typical failures and damages on rotor blades. The presentation demopnstrates the measurement principle and some results of onsite measurements carried out as “passive thermogra-phy”, i.e. without a defined heating procedure. Due the totally contactless meas-urement principle, TT can be applied to rotating blades as well as to resting blades. Both methods will be compared with respect to their possible realization.