Präsentation
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (133)
- Posterpräsentation (38)
- Beitrag zu einem Tagungsband (1)
Referierte Publikation
- nein (172)
Schlagworte
- Concrete (35)
- Ultrasound (30)
- Monitoring (29)
- Imaging (11)
- Coda wave interferometry (10)
- NDT (9)
- Ultraschall (9)
- Beton (5)
- Bridges (5)
- Civil engineering (5)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (133)
Concrete is known to be a very useful, flexible and durable construction material. However, due to excess load, fatigue, chemical processes, freeze-thaw or reinforcement corrosion concrete may suffer from degradation. If detected too late, repair is difficult and expensive.
The propagation of ultrasonic waves is influenced by changes in the properties and structure of the material, including, but not limited to, stress, temperature, moisture content and microcracking. Ultrasonic velocieties thus may serve as indicators for structural health. Traditional ultrasonic methods as transmission time of flight measurements are used since decades, but are not sensible enough to show subtle changes. Coda Wave Interferometry (CWI), originally developed in seismology to detect stress changes in the earth's crust uses the information in the late part of ultrasonic signals originating from multiple reflections and scattering. Since a few years it is used by several researchers for lab experiments on concrete.
Meanwhile specialized sensors to be embedded in concrete have been developed. We have conducted several lab and a few field experiments, which will be reported here. The capabilities and limitations of CWI are summarized.
Charakterisierung von Feuchte- und Salzbelastungen in Baumaterial durch Impedanzspektroskopie
(2006)
Bridge monitoring using embedded ultrasonics First results from the BLEIB reference structure
(2017)
The BLEIB reference structure The structure is a two-span, 24 m long inverse u-shaped post-tensioned concrete beam. Fibre optic sensing cables, RFID sensors and ultrasonic transducers are permanently embedded. Other sensing techniques (vibrational, optical, ultrasonic, mechanical) are applied externally. Tension can be adjusted. Loads can be placed at arbitrary locations. Limited damage is introduced to one span. The BLEIB reference structure is located at BAM‘s test site in Horstwalde, south of Berlin. Ultrasonic transducer before concreting.
Embedded ultrasonic transducers 14 piezo transducers have been embedded before concreting. They are located in five sections, two close to the centers of both spans respectively and one above the central bearing.
Load experiment and data evaluation In a first experiment load 2 (weight 2 t) was moved three times along the southern (right) span. The tension forces were modified as well.
Ultrasonic transmission measurements were repeated over time and evaluated using Coda Wave Interferomerry (CWI), which determines correlation coefficients and relative velocity changes as subtle indicators for loads and other changes in the material.
Seismic wave velocities are related to elastic moduli and other properties and can serve as indicators for changes in the material. They are conventionally determined by active measurements. Using ideas from seismic interferometry Determination from stacked cross-correlations of registrations of man- made and natural noise (“passive seimics“) is an effective alternative, as these data might be available from vibration monitoring anyway. The validity of this approach is demonstrated by a simple experiment based on recordings of man made noise using accelerometers at the reference structure. The s-wave (or more probable. guided wave) velocity was determined to be 2100 m/s in both active and passive experiments.
Seismic wave velocities are related to elastic moduli and other properties and can serve as indicators for changes in the material. They are conventionally determined by active measurements. Using ideas from seismic interferometry determination from stacked cross-correlations of registrations of man-made and natural noise (“passive seimics“) is an effective alternative, as these data might be available from vibration monitoring anyway. The validity of this approach is demonstrated by a simple experiment based on recordings of man made noise using accelerometers at the reference structure. The s-wave (or more probable. guided wave) velocity was determined to be 2100 m/s in both active and passive experiments.
The closure of underground nuclear waste disposal facilities requires reliable gas- and watertight engineered barriers. In Germany, barriers made from salt concrete have been evaluated in full scale. While the barriers seem to fulfill the requirements regarding permeability, some unexpected cracks have been detected at the surface and at depth. In cooperation between the Federal Company for Radioactive Waste Disposal (BGE) and the Federal Institute for Materials Research and Testing (BAM), several experiments have been carried out to evaluate the applicability for ultrasonic measurements in crack detection and general quality assurance. Both commercial instruments and specially developed devices have been tested on site. Using commercial ultrasonic echo devices designed for concrete inspection it was possible to detect cracks and object in salt concrete up to a depth of 2 m. The check for delamination in shotcrete is another field of application. A unique device available at BAM, the wide aperture, deep penetration instrument LAUS, was able to locate cracks and objects up to a depth of 8 m so far, which is thought to be a record for ultrasonic echo measurements in concrete. Adapted imaging procedures, partly adopted from geophysics, helped to reveal 3D structure at depth. In addition, we have developed ultrasonic probes to be deployed in boreholes, currently at up to 20 m depth. They can collect information on cracks and other features in a radius of about 1.5 m around the borehole in the current version and might be used in echo or transmission mode. Evaluation experiments have been performed at an experimental barrier at the ERAM site in Morsleben, Germany. The results showed several empty and injected cracks as well as built in instrumentation. The results have been verified using borehole endoscopy as well as core examination and will be used to set up a reliable quality assurance system for engineered barriers. All instruments are based on ultrasonic shear wave transducers with a frequency range between 25 kHz and 100 kHz. Current research focuses on the improvement of the hardware (e. g. optimization of array characteristics) and imaging techniques as Reverse Time Migration, both aiming at the improvement of depth of penetration, resolution and probability of detection.
To improve ultrasonic imaging of concrete structures, we transferred a seismic migration technique, the Reverse Time Migration (RTM), to non-destructive testing. A 2D elastic RTM algorithm was tested on synthetic ultrasonic echo data. Compared to the typically used synthetic aperture focusing technique (SAFT) as well as our acoustic RTM algorithm, the presented elastic RTM results show an enhancement in imaging vertical reflectors and complex features inside the 2D numerical concrete model.
Das Ultraschall-Echo-Verfahren ist eine wichtige Methode der zerstörungsfreien Prüfung (ZfP). Prüfaufgaben im Bauwesen beinhalten unter anderem die korrekte Dickenbestimmung von Konstruktionen, sowie die Lokalisierung von Einbauteilen und Fehlstellen. Das Abbildungsverfahren RTM (Reverse Time Migration) liefert oft bessere Bilder als konventionelle Verfahren. Die Datenaufnahme am Betonprobekörper erfolgte mit einem Scannersystem der BAM, bei dem jeweils ein Ultraschall-Prüfkopf als Sender bzw. Empfänger diente. Es wurden senkrecht zur Profilrichtung horizontal polarisierte Scherwellen genutzt. Die RTM wurde mit dem Softwarepaket Madagascar gerechnet.
Die Ergebnis zeigt das Potential dieser Methode im Bezug auf komplexe Strukturen. Die lateralen Positionen der Risse im RTM-Bild sowie deren Höhe innerhalb des Probekörpers, entsprechen recht genau dem visuellen Befund.
Ultrasound echo is a widely used NDT technique for determining the internal geometry of structures. Reverse-time migration (RTM) has been recently introduced to NDT applications, as an imaging method for ultrasound data, to overcome some of the limitations (e.g. imaging steeply dipping reflector) experienced by the Synthetic Aperture Focusing Technique (SAFT), the most commonly used imaging algorithm for these measurements.
The standard implementation of RTM also experiences some drawbacks caused by its imaging condition, which is based on the zero-lag of the cross-correlation between source and receiver wavefields and generates high-amplitude low-frequency artifacts. Three alternative imaging conditions, developed for seismic data applications, were tested for their ability to provide better images than the standard cross-correlation: illumination compensation, deconvolution and wavefield decomposition. A polyamide specimen was chosen for the simulation of a synthetic experiment and for real data acquisition. The migrations of both synthetic and real data were performed with the software Madagascar. The illumination imaging condition was able to reduce the low-frequency noise and had a good performance in terms of computing time. The deconvolution improved the resolution in the synthetic tests, but did not showed such benefit for the real experiments. Finally, as for the wavefield decomposition, although it presented some advantages in terms of attenuating the low-frequency noise and some unwanted reflections, it was not able to image the internal structure of the polyamide as well as the cross-correlation did. Suggestions on how to improve the cost-effectiveness of the implementation of the deconvolution and wavefield decomposition were presented, as well as possible investigations that could be carried out in the future, in order to obtain better results with those two imaging conditions.
Recent years have seen extended use of ultrasonic techniques for concrete infrastructure assessement. They are applied for quality assurance and condition assessement at bridges, power plants, dams and other important objects. However, there are still a couple of significant limitations. They include, but are not limited to depth of penetration, imaging complex structures or early stage detections of distributed damage. The talk will give information on recent research in this area. Specifically, the application of the unique deep penetration system LAUS is shown. Ultrasonic monitoring using embedded transducers to check for subtle and sudden changes in the material is introduced as well. Comments on initiatives for validation, standardization and certification will be given.
Fatigue is one of the most prevalent issues, which directly influences the service life expectancy of concrete structures. Fatigue has been investigated for years for steel structures. However, recent findings suggest that concrete structures may also be significantly subjected to the fatigue phenomena that could lead to premature failure of certainfatigue prone structural elements. To date, fatigue of reinforced concrete has been given little focus. and Kknowledge on the influence factors and durability/capacity effects on this material should be improved. Current technological means to measure fatigue in civil structures like bridges and wind turbines (both onshore and offshore) are outdated, imprecise and inappropriate.
Meanwhile, this topic has got much more attention as dynamic loading on concrete structures plays an increasing role, e.g. in bridges with increasing traffic and heavier trucks, in wind energy production due to inherent vibrations e.g. in offshore wind turbine support structures affected by wind and waves.
The European Innovative Training Networks (ITN) Marie Skłodowska-Curie Actions project INFRASTAR (Innovation and Networking for Fatigue and Reliability Analysis of Structures - Training for Assessment of Risk) provides research training for 12 PhD students. The project aims to improve knowledge for optimizing the design of new structures as well as for more realistic verification of structural safety and more accurate prediction of the remaining fatigue lifetime of existing structures.
First, the INFRASTAR research framework is detailed. Then it will be exemplified through the presentation of the major results of the four PhD students involved in the work package dealing with auscultation and monitoring. This includes the development and improvement of Fiber Optics (FO) and Coda Wave Interferometry (CWI) for crack sizing and imagery, new sensor technologies and integration, information management, monitoring strategy for fatigue damage investigation and lifetime prediction.
To safely dispose of nuclear waste in underground facilities, engineered barrier systems are needed to seal shafts and galleries. The material used in these barriers must be adapted to the host rock parameters. Shrinking and cracking must be avoided to provide a barrier with almost zero permeability. For repositories in salt rock environments, several types of salt concrete (SC) are possible construction materials.
Within the project SealWasteSafe, we compared the behavior of an innovative alkali-activated material (AAM) with standard SC in their hydration and hardening phase. To monitor the microstructural changes within the two materials SC and AAM, acoustic emission (AE) signals have been recorded for up to ~250 days on 340-liter-cubic specimens.
The phenomenon of AE is defined as the emission of elastic waves in materials due to the release of localized internal energy. Such energy release can be caused by the nucleation of micro-fracture, e.g., in concrete while curing or when exposed to load. The occurrence of AE events gives first rough indications of microstructural changes and potentially occurring cracking and thus, provides insights for structural health monitoring (SHM).
The results show, that for the first 28 days after casting, less AE activity was detected in the AAM compared to SC. After 61 days, in the AAM material, the number of AE events exceeded those observed in the SC. However, the majority of the AE detected and located in AAM was related to surface effects, and not to microstructural changes or occurring cracks within the bulk volume. Additionally, the source location analysis indicated, that despite lower activity in SC, we observed some clustering of the events. In contrast, in AAM, the activity inside the specimen is randomly distributed over the whole volume. The monitoring results help to estimate the material’s sealing properties which are crucial to assess their applicability as sealing material for engineered barriers.
Acoustic emission and ultrasonic monitoring of a prestressed concrete bridge in its final years
(2021)
Many European bridges built in the 1950s, 60s and 70s must be re-placed in the next decade due to structural deficiencies, insufficient load capacity or other issues. However, the existing bridges must be used for another couple of years even if flaws and damages already have been detected.
In Germany, several prestressed concrete bridges have been instrumented with acoustic emission detection systems to detect wire breaks and to provide early warning signs before failure. To evaluate and interpret the consequences of wire breaks additional instrumentation and accompanying measures as finite element modeling are required.
At a bridge in southern Germany we have complemented such a system with active ultrasonic monitoring. Repeated ultrasonic measurements are evaluated with a very sensible algorithm called coda wave interferometry. This method, inspired by seismology, has been shown to deliver early warning signs in lab experiments. Large volumes of concrete can be monitored with a limited network of ultrasonic transducers. We will report on the installation, capabilities, and lim-itations as well as first results.
The propagation of ultrasonic waves in concrete is affected by its micro- and macro-structure, geometry and properties as well as external influences as stress, temperature or moisture. In addition, age and degradation have a strong influence. Therefore, Ultrasound has been used to monitor concrete samples and structures since decades. However, early applications using conventional techniques as time-of flight or changes in amplitudes have been limited to detect changes in a late stage close to serviceability or ultimate load states.
Around 2000, several new, more sensitive techniques adopted from geophysics or other field of material sciences have been introduced to research in ultrasonic monitoring of concrete. The most discussed methodologies are coda wave interferometry, a technique which allows to detect very subtle changes from repeated ultrasonic measurements. Nonlinear acoustic techniques help to identify e. g. cracks even in an inhomogeneous background. Both techniques can be combined.
This paper reviews methods and results achieved so far on the laboratory scale and with full scale models the directions for future research and application is given as well.