Präsentation
Filtern
Dokumenttyp
- Vortrag (420)
- Posterpräsentation (88)
- Beitrag zu einem Tagungsband (9)
Sprache
- Englisch (340)
- Deutsch (176)
- Mehrsprachig (1)
Schlagworte
- Hydrogen (28)
- Safety (26)
- Ageing (21)
- Gefahrgut (21)
- Gefahrguttransport (21)
- Gefahrgutverpackungen (18)
- Transport (18)
- Wasserstoff (18)
- Drop test (16)
- Dangerous Goods Database (14)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (517) (entfernen)
The presentation starts with the first agreement of making a national attempt for the introduction of a pV-limit for hydrogen transport. It explains aspects of the technical development, provides an impression of catastrophic incidents, and explains the difference between risk control and consequence limitation. Then the process of determining consequences and the result from the discussion at the UN-WG are explained. The next part summarises the approach for counting the number of impacted persons as a function of the model of pressure wave, the pressure peak, the limits of injured persons and the population density. Finally, the latest state of the discussion and the subsequent recommendations for a pV-value and the adequate phrases for explanation are introduced.
The fibre-break model developed at Mines ParisTech has been able to show the effect of pressurisation rate on pressure vessels. This simulation however had to use a smaller model, as the computation time becomes enormous for simulating a real-scale pressure vessel. Reduced volume method then has been studied on different model configuration. The study showed that the method can be used only on certain configurations. It also gives a positive insight to reduce the computation time.
The developed model has certain limitations of the element size to be used in the simulation to characterise the strength of composite materials. A reduced volume method is proposed in order to reduce the number of degree of freedom of the finite element simulation.This study has revealed certain configuration to be followed to speed up the computation time.
The developed fibre-break model from Mines-ParisTech requires an improvement in terms of calculation time for analysing real-scale model. By implementing the proposed method, the number of representative volume element and monte-carlo run can be optimised to obtain certain confidence level of the results. By reducing this level, faster computation can be done. This approach has given us a positive insight that it can be used for studying real-scale model of composite pressure vessels.
BAM acts as authority and for service in safety assessment of packages for transport and storage of radioactive materials. We offer extensive test capabilities and application of analytical methods for design verification and simulation for all types of packages for the transport and storage of radioactive materials according with the international IAEA Regulations for the safe transport and for national storage acceptance criteria. BAM operates several test facilities for drop and stacking testing, leak testing and thermal testing. The large drop test tower allows dropping full-scale specimens up to 200,000 kg in any drop orientation as requested. The comprehensive test facilities combined with long-term experience, newest equipment and measurement devices according to the latest state-of-the-art technology ensures realisation of complex test campaigns for package safety evaluation.
Beyond that, non-destructive and destructive material test devices and experts are available. Equipment and application of all kinds of typical measurement categories can be offered for testing campaigns.
In recent years we performed testing of full-scale type B package models with complex handling and preparation procedures. The results were contributed for different package design approval procedures. Type A packages mainly designed for medical related transport purposes, were continuously tested according to the transport regulations over recent years as well. Moreover, we work on research topics with relevance to package safety. The mechanical behaviour of lid closure systems under transport and storage conditions and the thermal behaviour of impact limiters were recently of special importance for the assessment competencies of BAM and were investigated under use of our test facilities.
The paper describes the test facilities and capabilities for package design safety evaluation at BAM and shows examples from our recent work.
Packages for the transport of Spent Nuclear Fuel and high active radioactive waste are designed to withstand severe accidents. Specific mechanical and thermal tests are defined in the IAEA Regulations for the Safe Transport of Radioactive Materials in order to cover these hypothetical severe accidents. The thermal test mainly consists of a 30 minute fully engulfing fire. Components such as the package impact limiters can lead to supplementary energy release during the thermal test as they might continue burning after the fire phase. Local heat flux into the package can occur. Measurement of heat flux into the package is of importance to evaluate component temperatures and review their acceptance. The usability of heat flux sensors and temperature measurement equipment has to be tested to apply them in impact limiter fire testing. Further questions arise such as :“Is the infrared camera a useful tool to determine heat flux at the boundary surface?”
TAHYA Kick-Off Meeting
(2018)
The volumetric energy density of a gas can be increased by liquefaction, which occurs when the gas is cooled below the saturation point. Liquefied gases of great importance to the energy transition are Liquefied Hydrogen (LH2) and Liquefied Natural Gas (LNG), which can be liquefied at temperatures below 160°C. Systems for storing these gases typically must be overpressure resistant and require thermal super insulations (TSI) to hold cryogenic conditions and minimize boil-off losses from evaporation. TSI with vacuum and MLI or perlites are suitable for many applications involving LNG and LH2. Such systems are typically double-walled structures where the inner wall is in contact with the cryogenic liquefied gas. MLI or perlites are located in the gap between the inner and the outer wall, that is kept under vacuum conditions. This combination of insulations strongly reduces the heat transfer between the environment and the cryogenic liquefied gas. From an economic point of view the systems are well sophisticated. However, knowledge of the behavior of this kind of systems in a typical event such as a fire is limited, but necessary to evaluate the safety of the increasing number of applications.
The objective of the research is to determine how TSI behaves at different fire temperatures during fire exposure and afterwards. Special attention is paid to changes in the heat flux, the material properties and vacuum state over time. For this purpose, thermogravimetric analysis (TGA) studies have been carried out. In addition, a test rig was developed that allows testing of TSI at temperatures up to 1000°C under realistic integration conditions and subsequent analysis of the TSI samples. In the test rig the double-wall with vacuum and MLI or perlites inside is simulated. The fire conditions are simulated on one side of the double-wall by adjustable electrical heating elements. This process allows the implementation of repeatable heat flows of up to 100 kW/m². On the other side of the double-wall, cold or cryogenic conditions are simulated with a heat exchanger through which water or the vapor of liquid nitrogen (approx. -196°C) flows. The heat exchanger is also used to determine the heat flux through the double-wall. Thus, the test rig allows thermal loading and performance analysis of TSI samples at the same time.
Compared to tests with real cryogenic systems, tests with this experimental setup have the advantage that, first, the instrumentation is easier to realize, and a higher repeatability is ensured. Second, the local heat flow can be determined over time, and the sample of a TSI can be taken non-destructively and thus analyzed. Third, the tests are less risky as well as time+ and material intensive, so that more tests and variants can be investigated with the same budget.
Preliminary results obtained considering several types of MLI under vacuum show that all observed typs of MLI can be damaged under strong thermal loading. The damages observed were outgassing, melting, shrinkage, cracking, lump formation, and concomitant local loss of the MLI's function as a radiation shield. However, the study also shows that a damage does not always have an extreme effect on the insulating performance.
Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG)
establish themselves as important energy carriers in the transport
sector. Its storage requires tanks with Thermal Super Insulations
(TSI) to keep the transported fluid cold. TSI has proven itself in
various applications over a long time, but not in the land
transport sector, where accidents involving collisions, fires, and
their combination are to be expected. The focus of this study is
to investigate the behavior of different types of TSI when
exposed to a heat source that represents a fire. Therefore, a High-
Temperature Thermal Vacuum Chamber (HTTVC) was used that
allows the thermal loading of thermal insulation material in a
vacuum and measuring the heat flow through the TSI in parallel.
Within this study, 5 samples were tested regarding 3 different
types of MLI, rock wool, and perlites. The thermal exposure
caused different effects on the samples. In practice, this can be
connected to the rapid release of flammable gases as well as a
Boiling Liquid Expanding Vapour Explosion (BLEVE). These
results are relevant for the evaluation of accident scenarios, the
improvement of TSI, and the development of emergency
measures.
Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Its storage requires tanks with Thermal Super Insulations (TSI) to keep the transported fluid cold. The presentation includes 2 main topics of the department.
First TSI has proven itself in various applications over a long time, but not in the land transport sector, where accidents involving collisions, fires, and their combination are to be expected. To analyze fire scenarios a High-Temperature Thermal Vacuum Chamber (HTTVC) was developed that allows the thermal loading of thermal insulation material in a vacuum and measuring the heat flow through the TSI in parallel. Within this chamber, 5 samples were tested regarding 3 different types of MLI, rock wool, and perlites. In the presentation, the results are presented.
Second, the studying of accident scenarios enables the improvement of thermal superinsulation and to find novel insulation concepts. This is necessary for LH2 large-scale storages, for which state-of-the-art solutions are not suitable. Within the presentation, a novel insulation concept will be presented.
Die volumetrische Energiedichte eines Gases kann durch Verflüssigung erhöht wer-den. Diese findet statt, wenn das Gas unter den Siedepunkt abgekühlt wird. Verflüs-sigte Gase mit großer Bedeutung für die Energiewende sind verflüssigter Wasser-stoff (LH2) und verflüssigtes Erdgas (LNG), dessen Verflüssigung Temperaturen von unter -160 °C bedarf. Systeme zur Speicherung dieser verflüssigten Gase müssen in der Regel für Überdrücke ausgelegt sein und benötigen thermische Superisolierun-gen (TSI), um die tiefkalten Bedingungen über längere Zeit halten zu können und Verluste durch Boil-Off gering zu halten. TSI mit Vakuum und MLI oder Perlit sind für viele Anwendungen mit LNG und LH2 geeignet. Bei solchen Systemen handelt es sich in der Regel um doppelwandige Strukturen, bei denen die Innenwand mit dem tiefkalten Fluid in Kontakt steht. Die Lücke, zwischen der Innen- und der Außen-wand befindet sich unter Vakuumbedingungen und enthält zudem MLI oder Perlite. Diese Kombination von Isolationsmethoden ermöglicht es auf kleinstem Raum sehr gute thermische Isolationswirkung zu erreichen. Aus wirtschaftlicher Sicht sind die Systeme gut durchdacht. Das Wissen über das Verhalten dieser Systeme bei einem typischen Ereignis wie einem Brand ist jedoch begrenzt. Dieses Wissen ist aber not-wendig, um die Sicherheit der wachsenden Zahl von Anwendungen auf dem Markt bewerten zu können.
German spent nuclear fuel and high level waste is stored in dry conditions in interim storage facilities until a final repository will be ready for operation in the future. Dual purpose casks are used for the packaging of the materials to ensure transportability at any time during long-term interim storage and fulfilling both requirements from interim storage as well as transport. Germany’s 2011 decision to phase out utilization of nuclear energy has led to a high demand for casks for decommissioning power plants as quickly as possible. Cask serial production will continue at a high level for the next few years. In the process, a system of quality assurance measures ensures that every cask reliably complies with design specification according the transport approval certificate and storage license.
When the first casks were manufactured in Germany about 40 years ago, quality assurance was oriented towards pressure vessel and general nuclear manufacturing. The system was continuously adapted to the state of the art. In particular serial production, globalization of manufacturing and deep supplier chains had to be taken into account. The system of quality assurance measures applied today for cask manufacturing shall be presented here.
The quality assurance measures can be categorized as system-related and design-related. With respect to transport regulations for example, they are independently approved and monitored by the competent authority BAM and its authorized inspection experts. The qualification of the applicant is reviewed first in the context of the design approval procedure and then periodically. The qualification of component and cask manufacturers is also checked at the start of manufacturing and then periodically. Before the start of manufacturing documents such as quality plans are pre-assessed. Manufacturing and inspection are then performed according to the pre-assessed documents. Cask manufacturing is completed by a final inspection before commissioning. Periodic inspections during operation ensure preservation of the properties specified in the approval certificate over package life time. The type and the time interval of periodic inspections depend on the use of the package. For transport after interim storage a system of specific tests and inspections is prescribed.
Formulations have been assembled and (some) have been validated to simulate the potential damaging effect of a sloshing cargo on the railway material. Results suggest that: -Spatial determinism of the wheel forces due to sloshing, as a function of curve radius, distance between wheelsets and vehicle speed. -Sloshing forces can contribute in a significant way to railway material failure. Further analysis should be performed:-to validate these results (field observations)-to include a stress analysis of the potential effect of the yaw stiffness of the cars on the rail forces.
Structural health monitoring of hydrogen pressure vessels using distributed fiber optic sensing
(2024)
We report on distributed fiber optic sensing-based monitoring of hydrogen composite overwrapped pressure vessels (COPV) to simultaneously increase the operational lifespan and mitigate maintenance costs. Our approach represents, to the best of our knowledge, the first application of distributed fiber optic sensing for COPV Type IV monitoring, where the sensing fibers are attached to the surface, rather than integrated into the composite material. Specifically, we attach an optical fiber of 50 m to the pressure vessel's surface, covering both the cylindrical and dome sections. We note that our fiber optic sensing technique relies on swept wavelength interferometry providing strain information along the entire length of the optical fiber with high spatial resolution even at the millimeter scale. When the vessel is pressurized, the sensing optical fiber shows a linear strain response to pressure at every position along the fiber. After thousands of load cycles, the vessel finally fails with the optical fiber detecting and precisely localizing the damage in the vessel’s blind dome area. Furthermore, we discuss the potential of state-of-the-art signal processing methods and machine learning for advancing predictive maintenance. This could reduce the number of regular inspections, mitigate premature maintenance costs, and simultaneously increase the vessel’s remaining safe service life. We believe that the structural health monitoring of hydrogen pressure vessels with fiber optic sensors can enhance trust in hydrogen technology contributing to the energy transition in the future.
Am Fallturm auf dem Testgelände Technische Sicherheit (TTS) der BAM wurden bei Inspektionen Vorspannungsverluste in den Bolzen der Stahlverbindungen festgestellt. Um ein Verständnis für die zugrundeliegenden Trag- und Schädigungsmechanismen zu erlangen und um den Zustand der vorgespannten Schraubverbindungen langzeitlich zu überwachen, wurde am Fallturm ein Structural Health Monitoring (SHM) System installiert. Für die Auslegung des Monitoringsystems sowie zur Unterstützung der Untersuchung des Schädigungsprozesses wurde ein numerisches Modell erstellt und in Bezug auf die gemessenen Antworten des Tragwerks kalibriert.
Im Vortrag werden die experimentellen und numerischen Untersuchungen zur Systemidentifikation des Stahlrohrgitterturms als auch die Überwachungskampagne mit dem eingesetzten Monitoringsystem sowie die Messergebnisse und deren Bewertung vorgestellt.