Präsentation
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (142)
- Posterpräsentation (12)
Referierte Publikation
- nein (154)
Schlagworte
- Online NMR Spectroscopy (25)
- Prozessanalytik (25)
- Industrie 4.0 (21)
- Process Analytical Technology (21)
- CONSENS (18)
- Prozessindustrie (18)
- qNMR (14)
- Digitalisierung (12)
- Online NMR spectroscopy (11)
- Reaction Monitoring (11)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (70)
- 1.4 Prozessanalytik (70)
- 8 Zerstörungsfreie Prüfung (8)
- 8.6 Faseroptische Sensorik (6)
- 8.0 Abteilungsleitung und andere (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 1.3 Instrumentelle Analytik (2)
- 2 Prozess- und Anlagensicherheit (1)
- 2.1 Sicherheit von Energieträgern (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
Eingeladener Vortrag
- nein (142)
Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR.
Quantitative NMR Spectroscopy (qNMR) provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. Broadly accepted validation methods of qNMR spectroscopy will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden.
The first initiative towards a worldwide agreement goes back to a panel discussion at PANIC 2014 (Practical Applications of NMR in Industry Conference) in Chicago. Since that, the Validation Workshop takes place following the PANIC Conference each year, last in 2017 with a turnout of over 50 people. The group aims at identifying a network of NMR people concerned with validation that can ultimately assist each other through the validation process, harmonize the terminology and a standard approach for NMR validations and position the guidelines produced by consensus of the NMR community so that accreditation agencies can use this process.
In general, most quantitative organic chemical measurements rely on the availability of highly purified compounds to act as calibration standards. The traceability and providence of these standards is an essential component of any measurement uncertainty budget and provides the final link of the result to the units of measurement, ideally the SI. The more recent increase in the use of qNMR for the direct assessment of chemical purity however can potentially improve the traceability and reduce the uncertainty of the measured chemical purity at a reduced cost and with less material. For example, the method has beneficially been used by National Metrology Institutes for comparisons including comparisons on CCQM (Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology, www.bipm.org). First comparisons started 1998 with CCQM-P3 (Organics in solution) or CCQM-P35 (2002, EtOH in solution), were underpinned by a broad range of polarity and molecular size (CCQM–K55 series of purity studies including Valine, Aldrin, or Folic acid) and were continued with the recent pilot studies CCQM-P150 (2014, purity of Dimethyl sulfone) or CCQM-P150b (2017, purity of Pyributicarb).
Traditional ‘indirect’ methods of purity analysis require that all impurities are identified and quantified, leading to a minimum of four individual analytical methods (organic impurities, water, solvents, inorganic residue). These multiple technique approaches measure an array of different chemical impurities normally present in purified organic chemical compounds. As many analytical methodologies have compound-specific response factors, the accuracy and traceability of the purity assessment is dependent on the availability of reference materials of the impurities being available.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Due to recent advances in technical developments of NMR instruments such as acquisition electronics and probe design, detection limits of components in liquid mixtures were improved into the lower ppm range (approx. 5–10 ppm amount of substance) qNMR studies increasingly attract broader interest.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Due to recent advances in technical developments of NMR instruments such as acquisition electronics and probe design, detection limits of components in liquid mixtures were improved into the lower ppm range (approx. 5–10 ppm amount of substance). This showed that modern NMR equipment is also suitable for the observation of hydrocarbon samples in the expanded fluid phase or gas phase. Since Quantitative NMR spectroscopy (qNMR) is a direct ratio method of analysis without the need of calibration it was used to determine impurities in appropriate liquid and liquefied hydrocarbon isomers up to C6, which are used for preparation of primary gas standards, e.g., natural gas or exhaust gas standards. At the same time it is possible to yield structural information with a minimum of sample preparation. Thus, cross contaminations between different isomers of the observed hydrocarbons and their (NMR-active) impurities can be identified and quantified.
In general, most quantitative organic chemical measurements rely on the availability of highly purified compounds to act as calibration standards. The traceability and providence of these standards is an essential component of any measurement uncertainty budget and provides the final link of the result to the units of measurement, ideally the SI. The more recent increase in the use of qNMR for the direct assessment of chemical purity however can potentially improve the traceability and reduce the uncertainty of the measured chemical purity at a reduced cost and with less material. For example the method has beneficially been used by National Measurement institutes for recent CCQM comparisons including the CCQM–K55 series of purity studies.
Traditional ‘indirect’ methods of purity analysis require that all impurities are identified and quantified, leading to a minimum of 4 individual analytical methods (organic impurities, water, solvents, inorganic residue). These multiple technique approaches measure an array of different chemical impurities normally present in purified organic chemical compounds. As many analytical methodologies have compound-specific response factors, the accuracy and traceability of the purity assessment is dependent on the availability of reference materials of the impurities being available.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
In 2018, BAM (Federal Institute for Materials Research and Testing) and the young analysts of the department Analytical Chemistry at the Gesellschaft Deutscher Chemiker (German Chemical Society, GDCh) jointly organized the second summer school on quality assurance in analytical chemistry in Berlin, Germany. Over fifty doctoral students that are still in the initial stages of work participated in the week-long event and the participants were confronted with the most important basic concepts of internal and external systems of quality assurance in analytical chemistry.
Especially young scientists and scholars deal with the development of analysis methods and often generate an increasingly growing wealth of data. Results are mostly evaluated under quantitative aspects and need to be assessed subject-specifically. In addition to the purely scientific requirements these results also should meet the requirements of analytical quality assurance. For this purpose, the development of analytical methods is accompanied by a process of validation – the documented proof that a method is suitable for the intended purpose and the defined requirements.
This talk summarizes the didactic concept, which was used by the organizers to span an arc from the handling of process characteristics, such as accuracy, precision, linearity, recovery, up to measurement uncertainty and modern multivariate analysis techniques. In an open space workshop, the participants discussed their idea of quality management and worked out requirements after common sense. Interestingly, many participants had already implemented important quality assurance without professionally knowing it.
Prozessindustrie Gemeinsam Digital – Forschungsbedarf für die Digitalisierung der Prozessindustrie
(2019)
Die Digitale Transformation durchdringt weite Teile der Industrie mit einer zunehmenden Vernetzung und Digitalisierung entlang der Wertschöpfungskette.
Basierend auf dem Whitepaper der DECHEMA „Digitalisierung in der Chemieindustrie“ entsteht die Vision eines gläsernen Apparates mit einem zeitlich, räumlich und methodisch dichtem Monitoring der Betriebszustände, das eine daten- und modellbasierte Optimierung transienter oder instationärer Prozesse (das heißt An-/Abfahren, Laständerungen, etc.) erlaubt. Auch der nicht bestimmungsmäßige Betrieb von Apparaten oder Modulen wird zuverlässig erkannt. Basis ist hier die Implementierung von innovativer Messtechnik und neuartigen Sensoren in Kombination mit der Anwendung datengetriebener oder rigoroser Modelle zur Prozesssimulation und -kontrolle.
Anlagen, die auf diesem Konzept basieren, lassen sich sicher an Stabilitäts- bzw. Kapazitätsgrenzen und mit höherem Durchsatz betreiben. Trotz schwankender Rohstoffqualitäten kann eine gleichbleibende Zielqualität der Produkte mit rentablen Qualitätssicherungskosten garantiert werden. Dazu ist eine Vernetzung über weitere Branchen (Softwareingenieure, MSR-Technik, Betreiber, Hersteller) notwendig. Sie ergänzt komplementär die ENPRO-Initiative mit Themen der modularen Anlagenplanung und -konstruktion und modular verteilter Intelligenz. Ein Digitalisierungsbedarf besteht auch für bereits vorhandenen Anlagenbestand bzw. zukünftig nicht modular gestalteter Produktionsapparate der chemischen Industrie, um auch dort einen wesentlichen Beitrag zur Ressourcen- und Energieeffizienz zu leisten.
Prozessanalytik: Konzepte und Strategien Prozessanalytik in Flüssigkeiten (Hardwareüberblick)
(2011)
Homogen katalysierte Reaktionsschritte sind ein wichtiges Werkzeug in der chemischen Industrie. Durch die milden Reaktionsbedingungen hinsichtlich Temperatur und Druck bei gleichzeitig hoher Selektivität bieten diese die Möglichkeit energieeffizienter und ressourcenschonender Produktionsschritte. Eine der wichtigsten industriellen Anwendungen bildet die Hydroformylierung. Hier besteht das Katalysatorsystem meist aus Übergangsmetallkomplexen, vorwiegend Kobalt und Rhodium, die zur Steuerung der Selektivität und Löslichkeit mit mehrzähnigen Liganden koordiniert sind. Diese Komplexe liegen für eine effiziente Katalysator-rückführung in wässriger Lösung vor, was jedoch die Anwendbarkeit auf kurzkettige Edukte mit hinreichender Wasserlöslichkeit beschränkt.
Ein möglicher Lösungsansatz für die Verwendung langkettiger Alkene ist die Umsetzung der Reaktion in einer Mikroemulsion. Durch die gesteigerte Phasen-grenzfläche besteht ein effektiver Kontakt von Katalysator und Reaktanden bei gleichzeitiger Möglichkeit der Produktseparation durch Phasentrennung, während der Katalysator dem Reaktionsschritt zurückgeführt wird und das Verfahren damit wirtschaftlich macht.
Am Beispiel der Reaktion von 1-Dodecen zu Tridecanal wird der Einsatz von Online-NMR- und -Raman-Spektroskopie für die Prozessanalytik (sowie Applikation von komplexen Regelungskonzepten) innerhalb eines mizellaren Systems demonstriert. Ein speziell konzipierter Laboraufbau ermöglicht die Durchführung von Experimenten unter Prozessbedingungen für die in Mikroemulsionen äußerst anspruchsvolle Entwicklung und Kalibrierung von multivariaten Modellen für die Raman-Spektroskopie. Diese konnten anschließend im Rahmen einer mehrtägigen Betriebs-studie einer Miniplant am realen technischen System erprobt werden.