Präsentation
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (142)
- Posterpräsentation (12)
Referierte Publikation
- nein (154)
Schlagworte
- Online NMR Spectroscopy (25)
- Prozessanalytik (25)
- Industrie 4.0 (21)
- Process Analytical Technology (21)
- CONSENS (18)
- Prozessindustrie (18)
- qNMR (14)
- Digitalisierung (12)
- Online NMR spectroscopy (11)
- Reaction Monitoring (11)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (70)
- 1.4 Prozessanalytik (70)
- 8 Zerstörungsfreie Prüfung (8)
- 8.6 Faseroptische Sensorik (6)
- 8.0 Abteilungsleitung und andere (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 1.3 Instrumentelle Analytik (2)
- 2 Prozess- und Anlagensicherheit (1)
- 2.1 Sicherheit von Energieträgern (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
Eingeladener Vortrag
- nein (142)
Die Nutzung von Sensortechnologien, insbesondere im Bereich der Gasdetektion mit einem Schwerpunkt auf Wasserstoff, spielt eine entscheidende Rolle in verschiedenen Anwendungsbereichen der Wasserstofftechnologie. Sicherheitsüberwachung, Leckdetektion und Prozesskontrolle gehören zu den prominenten Anwendungsgebieten dieser Sensortechnologien. Ein zentrales Ziel ist die Erkennung von freigesetztem Wasserstoff sowie die genaue Bestimmung des Wasserstoff-Luftverhältnisses mithilfe von Gassensoren. Dies ist von entscheidender Bedeutung, um potenzielle Gefahren frühzeitig zu erkennen und angemessene Maßnahmen zu ergreifen.
Ein weiterer Schwerpunkt dieses Beitrags liegt auf der Analytik und der Verwendung zertifizierter Referenzmaterialien in Verbindung mit Metrologie für die Wasserstoffspeicherung. Dies gewährleistet eine präzise und zuverlässige Charakterisierung von Wasserstoff und unterstützt die Entwicklung sicherer Speichertechnologien. Im Rahmen des Euramet-Vorhabens Metrology for Advanced Hydrogen Storage Solutions (MefHySto) wird eine Kurzvorstellung präsentiert.
Der Vortrag stellt zwei zerstörungsfreie Prüfverfahren zum strukturellen Zustandsüberwachung (Structural Health Monitoring, SHM) für Wasserstofftechnologien vor. Insbesondere die Fehlstellenerkennung mittels geführter Ultraschallwellen spielt eine bedeutende Rolle bei der Lebensdauerüberwachung von Wasserstoffspeichern. Ein weiterer Aspekt ist die Anwendung faseroptischer Sensorik zur Schadensfrüherkennung von Wasserstoffspeichern. Diese zerstörungsfreien Prüfverfahren ermöglichen eine präzise und frühzeitige Identifizierung von Schäden, was die Sicherheit und Effizienz von Wasserstoffspeichersystemen entscheidend verbessert.
Smart functions of sensors simplify their use and enable plug-and-play, even though they are more complex. This is particularly important for, self-diagnostics, self-calibration and self-configuration/parameterization. Intelligent field devices, digital field networks, Internet Protocol (IP)-enabled connectivity and web services, historians, and advanced data analysis software are providing the basis for the future project “Industrie 4.0” and Industrial Internet of Things (IIoT).
Important smart features include connectivity and communication ability according to a unified protocol (OPC-UA currently most widely discussed), maintenance and operating functions, traceability and compliance, virtual description to support a continuous engineering, and well as interaction capabilities between sensors. This is a prerequisite for the realization of Cyber Physical Systems (CPS) within these future automation concepts for the process industry. Therefore, smart process sensors enable new business models for users, device manufacturers, and service providers.
The departure from current automation to smart sensor has already begun. Further development is based on the actual situation over several steps. Possible perspectives will be via additional communication channels to mobile devices, bidirectional communication, integration of the cloud and virtualization. The integration of virtual runtime environments can provide a more flexible topology for process control environments.
The talk summarizes the currently discussed requirements to process sensors 4.0 and introduces an online NMR sensor as an example, which was developed in the EU project CONSENS.
qNMR provides the most universally applicable form of direct concentration or purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties.
The workshop presents basic terms of statistics and uncertainty analysis, which are the basis for qNMR spectroscopy and data analysis such as, e.g., standard deviations, linear regression, significance tests, etc. and gives typical examples of applications in qNMR spectroscopy.
Introduction
NMR spectroscopy is one of the most important analytical methods in organic chemistry. While most analyses are carried out qualitatively with the aim of substance identification and structure elucidation, quantitative NMR spectroscopy (qNMR) is increasingly gaining importance in research and industry. qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties.
Methods
One of the most attractive features of quantitative NMR spectroscopy is that the NMR peak areas can be used directly for concentration quantification without further calibration. Another advantage of NMR spectroscopy is that the method has a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method that is independent of the matrix. This enables automated robust data evaluation strategies that can be used for online applications of qNMR spectroscopy.
Jancke et al. proposed NMR spectroscopy as a relative primary analytical method because it can be fully described by mathematical equations from which a complete uncertainty budget can be derived, allowing it to be used at the highest metrological level. Weber et al. discussed in detail important aspects of the procedure that enable the realisation of low measurement uncertainties in qNMR measurements. Since certification of CRM requires expanded mea¬sure¬ment uncertainties of less than 0.5 % (relative), the work of Weber et al. demonstrated for the first time that qNMR can fulfil this criterion.
Results
To date, further comparative studies have been carried out in metrology and industry, demonstrating the performance of quantitative NMR spectroscopy and further reducing measurement uncertainties. The development of validation concepts and the commercial availability of suitable certified reference materials facilitate the application, especially in the usually highly regulated industrial environment. Users can thus accelerate the development of analytical methods. The talk will cover a wide range of topics from current metrological activities to new challenges for qNMR spectroscopy and also deals with aspects such as validation and accreditation.
Innovative aspects
• qNMR provides the most universally applicable form of direct purity determination
• Expanded measurement uncertainties lower than 0.15 % (relative) possible
• Benchtop NMR instruments increasingly used for qNMR spectroscopy
Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR.
Quantitative NMR Spectroscopy (qNMR) provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. Broadly accepted validation methods of qNMR spectroscopy will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden.
The first initiative towards a worldwide agreement goes back to a panel discussion at PANIC 2014 (Practical Applications of NMR in Industry Conference) in Chicago. Since that, the Validation Workshop takes place following the PANIC Conference each year, last in 2017 with a turnout of over 50 people. The group aims at identifying a network of NMR people concerned with validation that can ultimately assist each other through the validation process, harmonize the terminology and a standard approach for NMR validations and position the guidelines produced by consensus of the NMR community so that accreditation agencies can use this process.
In general, most quantitative organic chemical measurements rely on the availability of highly purified compounds to act as calibration standards. The traceability and providence of these standards is an essential component of any measurement uncertainty budget and provides the final link of the result to the units of measurement, ideally the SI. The more recent increase in the use of qNMR for the direct assessment of chemical purity however can potentially improve the traceability and reduce the uncertainty of the measured chemical purity at a reduced cost and with less material. For example, the method has beneficially been used by National Metrology Institutes for comparisons including comparisons on CCQM (Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology, www.bipm.org). First comparisons started 1998 with CCQM-P3 (Organics in solution) or CCQM-P35 (2002, EtOH in solution), were underpinned by a broad range of polarity and molecular size (CCQM–K55 series of purity studies including Valine, Aldrin, or Folic acid) and were continued with the recent pilot studies CCQM-P150 (2014, purity of Dimethyl sulfone) or CCQM-P150b (2017, purity of Pyributicarb).
Traditional ‘indirect’ methods of purity analysis require that all impurities are identified and quantified, leading to a minimum of four individual analytical methods (organic impurities, water, solvents, inorganic residue). These multiple technique approaches measure an array of different chemical impurities normally present in purified organic chemical compounds. As many analytical methodologies have compound-specific response factors, the accuracy and traceability of the purity assessment is dependent on the availability of reference materials of the impurities being available.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Due to recent advances in technical developments of NMR instruments such as acquisition electronics and probe design, detection limits of components in liquid mixtures were improved into the lower ppm range (approx. 5–10 ppm amount of substance) qNMR studies increasingly attract broader interest.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Due to recent advances in technical developments of NMR instruments such as acquisition electronics and probe design, detection limits of components in liquid mixtures were improved into the lower ppm range (approx. 5–10 ppm amount of substance). This showed that modern NMR equipment is also suitable for the observation of hydrocarbon samples in the expanded fluid phase or gas phase. Since Quantitative NMR spectroscopy (qNMR) is a direct ratio method of analysis without the need of calibration it was used to determine impurities in appropriate liquid and liquefied hydrocarbon isomers up to C6, which are used for preparation of primary gas standards, e.g., natural gas or exhaust gas standards. At the same time it is possible to yield structural information with a minimum of sample preparation. Thus, cross contaminations between different isomers of the observed hydrocarbons and their (NMR-active) impurities can be identified and quantified.
In general, most quantitative organic chemical measurements rely on the availability of highly purified compounds to act as calibration standards. The traceability and providence of these standards is an essential component of any measurement uncertainty budget and provides the final link of the result to the units of measurement, ideally the SI. The more recent increase in the use of qNMR for the direct assessment of chemical purity however can potentially improve the traceability and reduce the uncertainty of the measured chemical purity at a reduced cost and with less material. For example the method has beneficially been used by National Measurement institutes for recent CCQM comparisons including the CCQM–K55 series of purity studies.
Traditional ‘indirect’ methods of purity analysis require that all impurities are identified and quantified, leading to a minimum of 4 individual analytical methods (organic impurities, water, solvents, inorganic residue). These multiple technique approaches measure an array of different chemical impurities normally present in purified organic chemical compounds. As many analytical methodologies have compound-specific response factors, the accuracy and traceability of the purity assessment is dependent on the availability of reference materials of the impurities being available.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
In 2018, BAM (Federal Institute for Materials Research and Testing) and the young analysts of the department Analytical Chemistry at the Gesellschaft Deutscher Chemiker (German Chemical Society, GDCh) jointly organized the second summer school on quality assurance in analytical chemistry in Berlin, Germany. Over fifty doctoral students that are still in the initial stages of work participated in the week-long event and the participants were confronted with the most important basic concepts of internal and external systems of quality assurance in analytical chemistry.
Especially young scientists and scholars deal with the development of analysis methods and often generate an increasingly growing wealth of data. Results are mostly evaluated under quantitative aspects and need to be assessed subject-specifically. In addition to the purely scientific requirements these results also should meet the requirements of analytical quality assurance. For this purpose, the development of analytical methods is accompanied by a process of validation – the documented proof that a method is suitable for the intended purpose and the defined requirements.
This talk summarizes the didactic concept, which was used by the organizers to span an arc from the handling of process characteristics, such as accuracy, precision, linearity, recovery, up to measurement uncertainty and modern multivariate analysis techniques. In an open space workshop, the participants discussed their idea of quality management and worked out requirements after common sense. Interestingly, many participants had already implemented important quality assurance without professionally knowing it.