Präsentation
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (19984)
- Posterpräsentation (6202)
- Beitrag zu einem Tagungsband (36)
- Sonstiges (8)
- Zeitschriftenartikel (2)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (2)
Sprache
- Deutsch (16750)
- Englisch (9430)
- Mehrsprachig (25)
- Spanisch (13)
- Französisch (11)
- Russisch (3)
- Tschechisch (1)
- Ungarisch (1)
Schlagworte
- Korrosion (265)
- Corrosion (182)
- Additive manufacturing (159)
- Nanoparticles (151)
- Additive Manufacturing (147)
- LIBS (137)
- Hydrogen (125)
- Concrete (124)
- Fluorescence (123)
- Additive Fertigung (121)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (1256)
- 6 Materialchemie (1193)
- 1 Analytische Chemie; Referenzmaterialien (951)
- 7 Bauwerkssicherheit (919)
- 9 Komponentensicherheit (818)
- 4 Material und Umwelt (586)
- 5 Werkstofftechnik (576)
- 3 Gefahrgutumschließungen; Energiespeicher (527)
- 9.4 Integrität von Schweißverbindungen (377)
- 7.6 Korrosion und Korrosionsschutz (373)
Moisture testing and mapping
(2024)
Most building materials are porous and hydrophilic. Thus, for condition assessment and damage detection a determination of the material moisture is required. In this lecture, a short overview is given regarding moisture transport in porous media in the hygroscopic range. Then, several non-destructive measurement techniques are introduced. Here, the focus lies on their practical application and limitations.
In the approval process of dangerous goods packagings, drop tests onto a flat, essentially unyielding surface are used to assess resistance against mechanical damage. International adopted regulations like ADR and RID define filling good dependent drop heights and filling degrees whilst the user needs to define the maximum gross mass to be tested and approved. Maximum packaging gross mass is defined conservatively and not reached in practice. To meet the defined gross mass in testing, using additives is permitted. However, in some cases, additives are not desirable due to packaging design or filling substance properties. This leads to deviations from the initial gross mass definition. Hence, a certain drop height adjustment is necessary to achieve the required impact loading. Laboratories frequently adjust drop height assuming a perfectly elastic collision which is inaccurate. Appropriate adjustment is not trivial due to energy conversion processes, e.g., plastic deformation. In this work, a test stand is developed for measuring the change in kinetic energy of different packaging designs and filling substances in regulative drop tests. The experimental results are used to validate finite-element (FE) models so that packaging properties can be varied in simulated drop test scenarios. The findings intend to describe the appropriate drop height adjustment of the respective packaging with same design but deviating gross mass to produce comparable mechanical response. The results are highly beneficial for testing laboratories, approval issuing authorities and packaging institutes confronted with the problem of testing packages with gross masses other than those to be approved.
Hybrid additive manufacturing is becoming increasingly important in the field of additive manufacturing. Hybrid approaches combine at least two different manufacturing processes. The focus of this work is the build-up of geometries onto conventionally manufactured parts using laser-based powder bed fusion of metals (PBF-LB/M). The hybrid build-up requires a precise position detection system inside the PBF-LB/M machines to determine the exact position of the existing component. For this purpose, high-resolution camera systems can be utilized. However, the use of a camera system is associated with several challenges. The captured images are subject to various distortions of the optical path. Due to these distortions, it is not possible to use the images for measurements and, therefore, it is not possible to calculate the positions of objects. In this study a homography matrix is calculated to correct keystone distortion in the images. Different calibration patterns have been tested for the calculation of the homography matrix. The influence of the number of calibration points on the precision of position detection of objects is determined. Furthermore, the influence of an additional camera calibration by using ChArUco boards is evaluated. The result is a camera calibration workflow with associated calibration pattern for a precise position detection of parts inside PBF-LB/M machines allowing a hybrid build-up with minimum physical offset between base component and build-up.
Stable metal isotopes receive increasing attention as medical biomarkers due to their potential to detect changes of the metal metabolism related to disease. Potential mechanisms causing isotope fractionation include biological processes that involve redox- or bond-forming reactions and interaction of metals during transmembrane import and export. In order to advance our understanding of the underlying processes responsible for isotope fractionation between normal and diseased cells, we need in situ, spatially resolved methods. Despite its frequent use, laser ablation - multi-collector - inductively coupled plasma mass spectrometry (LA-MC-ICPMS) analysis of biological material is severely limited by the scarcity of matrix-matched standards. Such matrix-matched standards are necessary to correct for instrumental sources of isotope fractionation such as particle size distribution, ablation physics and differential ionization.
Copper stable isotopes have proven to be a particularly powerful tool to identify differences in isotope composition between tumors and healthy tissue suggesting application in cancer diagnosis [1, 2]. To further our knowledge of Cu isotope fractionation processes induced by diseases we have developed gelatin-based bracketing standards allowing to correct instrumentally induced isotope fractionation during LA-MC-ICPMS analysis. Since gelatin properties resemble properties of protein-rich cellular material, they mimic biological matrices and their ablation behaviour. Hence, gelatin standards are spiked with known amounts of Cu stable isotopes of a known Cu isotope composition and used as matrix-matched bracketing standard. A Ni reference solution was aspirated to the plasma to allow for mass bias correction and laser energy densities were below the glass ablation threshold. The method achieved reproducibilities of better than 0.10‰ (2SD) for inorganic reference materials and reproducibilities of better than 0.17‰ (2SD) for biological reference materials. The developed routine is tested on biomedical samples and the in situ Cu isotope data will be presented.
In der automatisierten Ultraschallprüfung von Komponenten mit komplexen Oberflächengeometrien werden zur Führung des Prüfkopfes zunehmend 6-Achsen-Roboter erprobt. Diese stellen die notwendige Automatisierbarkeit und Flexibilität bereit, um die lokal senkrechte Einschallung sicherzustellen. Durch den Einsatz von linearen Arrays und bildgebenden Verfahren können die Bilder oder die daraus extrahierten Merkmale zu einer Rekonstruktion in 3D zusammengesetzt werden. Die Anforderungen an die Prüfbahnen für die bildgebende Array-Ultraschallprüfung gehen dabei über konventionellen Bahnplanungsprogramme hinaus. Es wird ein Prozess vorgestellt, der Roboterbahnen auf der Grundlage des 3D-Modells von Körpern mit doppelt gekrümmter Oberfläche unter Berücksichtigung der Prüfparameter erzeugt. Hierbei wird zum einen die senkrechte Prüfkopfstellung und zum anderen eine optimale Abdeckung der Oberfläche realisiert. Dabei wird die lokale Oberflächengeometrie beachtet, da diese das Reflexionsverhalten beeinflusst und sich daher auf die optimale Verteilung und Orientierung der Prüfpositionen auswirkt. Damit einhergehend erfolgt eine Ablösung von konventionellen Konzepten, die auf linearen Prüfbahnen basieren, welches spannende neue Prüfstrategien eröffnet.
Durch das alkalische Porenwassermilieu ist Stahl im Beton vor Korrosion geschützt. Unter ungünstigen Umgebungsbedingungen (Karbonatisierung, Chlorideintrag) kann die passive Deckschicht auf der Stahloberfläche zerstört werden. Im weiteren Verlauf können sich korrosionsbedingte Folgeschäden, wie Risse und Abplatzungen am Bauwerk ergeben. Um notwendige Sanierungsmaßnahmen sind frühzeitige und weitgehend zerstörungsfrei ermittelte Informationen über das aktuelle Korrosionsverhalten der Stahlbewehrung von großer Bedeutung. Die Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche aktiv korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. Wie und unter welchen Randbedingungen dieses Messverfahren zielführend eingesetzt werden kann, ist im Merkblatt B 03 der dgzfp erörtert.
Electrochemical potential mapping is a recognized technique for the localization of corroding reinforcing steels. Areas of corroding reinforcement steel can be located in a non-destructive manner by means of this procedure. Half‐cell potential measurements are used in order to detect chloride‐induced corrosion. However, it is not recommended in order to assess the risk of carbonation‐induced corrosion. For this purpose, determining the carbonation depth and the concrete cover appears more appropriate. The content of this specification exclusively refers to the application of mobile, local variable reference electrodes, which are only placed on the concrete surface while measuring. The technique distinguishes itself thereby from the range of corrosion monitoring systems with stationary installed reference electrodes and sensor systems, respectively, whereby it is possible to continuously track measurements within the area of the installed electrodes. However, these methods are not dealt with in this specification.