Homochirality is an obvious feature of life on Earth. On the other hand, extraterrestrial samples contain largely racemic compounds. The same is true for any common organic synthesis. Therefore, it has been a perplexing puzzle for decades how these racemates could have formed enantiomerically enriched fractions as a basis for the origin of homochiral life forms. Numerous hypotheses have been put forward as to how preferentially homochiral molecules could have formed and accumulated on Earth. In this article, it is shown that homochirality of the abiotic organic pool at the time of formation of the first self-replicating molecules is not necessary and not even probable. It is proposed to abandon the notion of a molecular ensemble and to focus on the level of individual molecules. Although the formation of the first self-replicating, most likely homochiral molecule is a seemingly improbable event, on a closer look, it is almost inevitable that homochiral molecules have formed simply on a statistical basis. In this case, the non-selective leap to homochirality would be one of the first steps in chemical evolution directly out of a racemic “ocean”. Moreover, most studies focus on the chirality of the primordial monomers with respect to an asymmetric carbon atom. However, any polymer with a minimal size that allows folding to a secondary structure, would spontaneously lead to asymmetric higher structures (conformations). Most of the functions of these polymers would be influenced by this inherently asymmetric folding. To summarize, simple and universal mechanisms may have led to homochiral self-replicating systems in the context of chemical evolution. A homochiral monomer pool is deemed unnecessary and probably never existed on primordial Earth.
Antikörper sind in der medizinischen Welt nicht mehr wegzudenken. Ihr Einsatz-Repertoire als Therapeutika für die Behandlung diverser Krankheiten und Infektionen weitet sich von Jahr zu Jahr mehr aus. Dabei basiert ein Großteil der verwendeten Antikörper zu diesem Zeitpunkt auf monoklonalen Antikörpern auf Basis von Hybridomazellen. Doch hier könnten rekombinante Antikörper aufgrund ihrer Vektor-basierten Expression eine vielversprechende und womöglich sogar revolutionierende Alternative bieten. So ergeben sich neue Optimierungsoptionen für Merkmale wie Affinität, Stabilität und Kompatibilität über Anpassungen auf genetischer oder posttranslationaler Ebene. Allerdings ergibt sich kein Anwendungszweck ohne die vorhergehende detaillierte Charakterisierung der Antikörper. Denn nur mit spezifischem Wissen über die diversen Eigenschaften und Wechselwirkungen kann eine effektive und präzise Verwendung in der Diagnostik und Therapeutik gewährleistet werden und auf diese Weise Leben retten.
Aus diesem Grund beschäftigt sich diese Masterarbeit mit der Vertiefung der rekombinanten Antikörper-Thematik. Dazu soll ein Anti-Tetanus-Antikörper erstmals rekombinant in verschiedenen Zelllinien hergestellt und anschließend über umfangreiche analytische Verfahren mit einem Fokus auf die Einflussanalyse der unterschiedlichen posttranslationalen Glykosylierungen charakterisiert werden. Zu diesem Zweck wurden als Grundlage einerseits zwei P1316-Dual-Expressions-Vektoren mit variierenden Insert-Positionen der schweren und leichten Kette durch Gibson-Assembly sowie individuellen pRK5-Plasmide für eine separiert Expression der Antikkörperketten mithilfe Restriktionsfragment-Ligation generiert. In einer Gegenüberstellung der der Expressionsausbeuten stellte sich die Überlegenheit der P1316-Plasmid-Konfiguration heraus, in der das Leichtketten-Insert an der ersten Expressionsstelle positioniert ist. Deshalb wurde dieser Vektor als Ausgangspunkt für die anschließende hochskalierten Herstellung des Anti-Tetanus-Antikörpers in Expi293F-GnTI- und ExpiCHO-S-Zellen verwendet. Ein ELISA bestätigte die Bindungsaktivität der rekombinanten Antikörper am Tetanus-Toxoid unabhängig vom Expressionssystem. Nach einer folgenden Optimierung der für die Aufreinigung verwendeten Protein-A-Affinitätschromatographie, wurde über weitere Charakterisierungsmethoden wie Größenausschlusschromatographie und dynamische Lichtstreuung eine vergleichbare Aggregation aufgrund der sauren Elution aufgezeigt. In diesem Kontext wurde die Notwendigkeit einer Zweistufen-Präparation mit Affinitäts- und Größenausschlusschromatografie für den Erhalt monodisperser Proben verdeutlicht. Zudem wurden die verschiedenen intakten Massen mitsamt ihrer spezifischen Glykan-abhängigen Streumaßen in Relation zum monoklonalen NISTmAB-Referenzantikörper bestimmt. Dabei konnte den Erwartungen nach sowohl die geringere Masse als auch die uniformere Glykosylierung der in Expi293 GnTI- exprimierten Immunoglobuline in Relation zum ExpiCHO-S-Antikörper nachgewiesen werden. Anschließend wurde das Stabilitätsverhalten mittels thermischer Entfaltung und dynamischer Lichtstreuung über einen ausgeweiteten Zeitraum sowie verschiedenen Temperaturen dokumentiert. Grundlegend wurde eine höhere thermische Stabilität der zweiten konstanten Schwerketten-Domäne des aus ExpiCHO-S-Zellen stammenden Antikörpers nachgewiesen. Außerdem konnte eine problemlose Lagerungsfähigkeit beider unterschiedlich glykosylierter Antikörper bei Raumtemperatur für mindestens 4 Wochen festgestellt werden. Des Weiteren wurde die Langzeitlagerung im Rahmen der Auswirkung von Gefrier-Auftau-Zyklen mit gleichbleibenden Methoden sowie zusätzlicher Größenausschlusschromatographie erprobt. Hierbei stellte sich der Erhalt der strukturellen Integrität nach bis zu 15 Zyklen heraus. Allerdings geht die Monodispersität bereits nach wenigen Zyklen verloren, wobei die geringfügiger glykosylierten Expi293F-GnTI-Anti-Tetanus-Antikörper eine stärkere Beeinträchtigung durch multiple Gefrier-Auftau-Zyklen aufwiesen.
The development of a Lab-on-a-Chip (LoC) is presented, which can detect reactive phosphorous compounds in the gas phase in combination with an optochemical hand-held sensor. The LoC prototype contains three pairs of sensing materials containing fluorescent indicator dyes in various carrier materials. By measuring the fluorescence response to phosphoryl chloride, a surrogate compound, the detection of chemical warfare agents (CWAs) in gas phase becomes possible within seconds, introducing a novel approach to CWA detection.
Mykotoxine sind sekundäre Stoffwechselprodukte, die von Schimmelpilzen gebildet werden. Sie sind unvermeidliche Lebensmittelkontaminanten und stellen daher ein ernstes Gesundheitsrisiko für Mensch und Tier dar. Aus diesem Grund hat die Europäische Kommission Vorschriften erlassen, die Höchstwerte für Mykotoxine in bestimmten Lebensmitteln vorsehen. Um die gesetzlichen Grenzwerte einzuhalten, müssen in der Lebensmittelindustrie Mykotoxinanalysen der eingehenden Waren durchgeführt werden.
Gegenwärtig umfasst die Analyse zeitaufwändige Probenvorbereitungsschritte, denen in der Regel eine chromatographische Analyse folgt.
Immunoassays ermöglichen eine Vor-Ort-Analyse, aber in der Regel sind für feste Lebensmittelproben lösungsmittelbasierte Extraktionsschritte erforderlich. Da Immunoassays in der Regel nicht mit den hohen Lösungsmittelkonzentrationen kompatibel sind, die üblicherweise für die Mykotoxinextraktion verwendet werden (z.B. Acetonitril oder Methanol), war es das Ziel dieser Arbeit, ein Extraktionsverfahren für die Mykotoxine Deoxynivalenol und Ochratoxin A aus Weizenmehl und Getreide zu entwickeln, das für Immunoassays und -sensoren verwendet werden kann. Vier verschiedene Lösungsmittel, Methanol (10 %), Ethanol (5 %) und Acetonitril (10 %) sowie Milli-Q-Wasser wurden für die Extraktion des Analyten Deoxynivalenol getestet. Um negative Umweltaspekte zu vermeiden und aufgrund der vergleichbaren Extraktionseffizienz von Milli-Q-Wasser gegenüber den anderen Lösungsmitteln, wurde Milli-Q-Wasser als Extraktionslösung im optimierten Extraktionsprotokoll für Deoxynivalenol verwendet.
Es wurden verschiedene Extraktionsbedingungen, wie die Extraktionszeit, das Lösungsmittel-Feststoff-Verhältnis, der Filtrationsschritt, der Zentrifugationsschritt sowie die Zusammensetzung des Wassers untersucht. Auf der Grundlage der Ergebnisse wurde ein Extraktionsprotokoll festgelegt, mit dem Wiederfindungsraten in einem Bereich von x bis x erzielt wurden. Das Extraktionsprotokoll umfasste die Extraktion von 2 g Weizenmehl mit 40 ml Milli-Q-Wasser für 30 Minuten, die anschließende Zentrifugation bei 3000 U/min für 15 Minuten bei 4 °C und die Filtration des Überstands.
The contamination of drinking water with pharmaceuticals represents a severe health risk. In order to monitor the drinking water quality continuously and enable quick countermeasures in case of contamination, novel sensors are required. Here, immunoanalytical methods based on the binding of the analyte to highly selective antibodies can be helpful. In this work, magnetic bead-based immunoassays (MBBAs) have been developed for the detection of two relevant contaminants of drinking water: diclofenac (DCF) and amoxicillin (AMX). In case of the latter, not only the parent drug is of interest in the risk assessment but also its hydrolysis products (HPs). In a comprehensive study, the influence of external factors and intrinsic properties of the water on the rate of hydrolysis was investigated. As the hydrolysis of AMX further impacts the recognition by the antibody, a strategy to analyze samples with unknown hydrolysis degree of AMX was established employing the enzyme β-lactamase in sample preparation. For both analytes, the MBBAs enable the fast quantification with results obtained in less than one hour which represents a major improvement over conventional immunoassays like the enzyme-linked immunosorbent assay (ELISA). Compared to the respective ELISAs with the same antibodies, the MBBAs further exhibit improved analytical parameters such as a broader measurement range and lower limits of detection. Due to the magnetic properties of the beads that serve as a platform for the assays, they are suitable for the mobile and automated detection at the point-of-care. An integrated diagnostic system was designed in which electrochemical detection with chronoamperometry on a microfluidic chip allows for further miniaturization of the system to enable monitoring of the drinking water quality online in water supply pipes at waterworks.
Development of electrochemical antibody-based and enzymatic assays for mycotoxin analysis in food
(2023)
Electrochemical methods are promising to meet the demand for easy-to-use devices monitoring key parameters in the food industry. Many companies run own lab procedures for mycotoxin analysis, but it is a major goal to simplify the analysis. The enzyme-linked immunosorbent assay using horseradish peroxidase as enzymatic label, together with 3,3',5,5' tetramethylbenzidine (TMB)/H2O2 as substrates allows sensitive mycotoxin detection with optical detection methods. For the miniaturization of the detection step, an electrochemical system for mycotoxin analysis was developed. To this end, the electrochemical detection of TMB was studied by cyclic voltammetry on different screen-printed electrodes (carbon and gold) and at different pH values (pH 1 and pH 4). A stable electrode reaction, which is the basis for the further construction of the electrochemical detection system, could be achieved at pH 1 on gold electrodes. An amperometric detection method for oxidized TMB, using a custom-made flow cell for screen-printed electrodes, was established and applied for a competitive magnetic bead-based immunoassay for the mycotoxin ochratoxin A. A limit of detection of 150 pM (60 ng/L) could be obtained and the results were verified with optical detection. The applicability of the magnetic bead-based immunoassay was tested in spiked beer using a handheld potentiostat connected via Bluetooth to a smartphone for amperometric detection allowing to quantify ochratoxin A down to 1.2 nM (0.5 µg/L). Based on the developed electrochemical detection system for TMB, the applicability of the approach was demonstrated with a magnetic bead-based immunoassay for the ergot alkaloid, ergometrine. Under optimized assay conditions a limit of detection of 3 nM (1 µg/L) was achieved and in spiked rye flour samples ergometrine levels in a range from 25 to 250 µg/kg could be quantified. All results were verified with optical detection. The developed electrochemical detection method for TMB gives great promise for the detection of TMB in many other HRP-based assays. A new sensing approach, based on an enzymatic electrochemical detection system for the mycotoxin fumonisin B1 was established using an Aspergillus niger fumonisin amine oxidase (AnFAO). AnFAO was produced recombinantly in E. coli as maltose-binding protein fusion protein and catalyzes the oxidative deamination of fumonisins, producing hydrogen peroxide. It was found that AnFAO has a high storage and temperature stability. The enzyme was coupled covalently to magnetic particles, and the enzymatically produced H2O2 in the reaction with fumonisin B1 was detected amperometrically in a flow injection system using Prussian blue/carbon electrodes and the custom-made wall-jet flow cell. Fumonisin B1 could be quantified down to 1.5 µM (≈ 1 mg/L). The developed system represents a new approach to detect mycotoxins using enzymes and electrochemical methods.
Concrete is the most important human-made material because it serves as the basis of our built environment. Since the properties of concretes are dominated by their key compound, cement, devising a way to determine the cement’s origin, known as provenancing, is of great importance for answering different provenance-related questions. These questions range from liability issues when damage occurs to concrete-made structures, to forensic investigations where cement particles are found at crime scenes. This thesis showcases the use of isotope techniques to answer these provenance-related questions. Conventional 87Sr/86Sr and 143Nd/144Nd isotope and elemental ratios consisting of Ca, Sr, K, Mn, Mg, and Ti are used as fingerprints for ordinary Portland cement (OPC) provenancing. The first part of this thesis describes research previously conducted in fingerprinting cementitious materials, providing an overview of provenance studies of cement and the main approaches commonly used. In several studies, the origin of clinker for certain locations was determined via different approaches. However, clinker is an intermediate product, which is available only at the production site and therefore, the practical relevance is rather limited. Furthermore, the use of Sr and Nd isotope systems, together with elemental fingerprints are presented as state of the art in the field. Therein, the principal approach for the overall study is sketched. For the second part of the study, a sample preparation technique for Sr isotopes in Portland cement was developed. The aim was to find the most appropriate sample preparation procedure for cement provenancing and selection was realised by comparing the 87Sr/86Sr isotope ratios of differently treated OPCs with those of the corresponding clinkers. Based on these findings, the third part of the study focused on the measurements of Sr and Nd isotope ratios, together with elemental ratios, to establish a reliable technique for OPC provenancing. The outcomes of this final stage are then used to establish a procedure for fingerprinting cements. This becomes possible with the use of Sr and Nd isotope ratios and geochemical profiles. To perform isotope ratio measurements and obtain reliable data, it was necessary to establish a quality control procedure. Thus, an interlaboratory comparison (ILC) was organised to characterise 87Sr/86Sr isotope ratios in geological and industrial reference materials by applying the conventional method for 87Sr/86Sr isotope ratios. As reference material, four cements (VDZ 100a, VDZ 200a, VDZ 300a, IAG OPC-1), one limestone (IAG/CGL ML-3) and one slate (IAG OU-6) were selected, thus covering a wide range of Sr isotope signatures.
Data file (RData) containing measurement data recorded during the production process of the Certified Reference Material BAM-A001 containing Polycyclic Aromatic Hydrocarbons (PAH) in olive oil. The data can be most conveniently openend using the Shiny-App eCerto which is accessible at https://www.bam.de/eCerto.
Volatile organic compound (VOC) emissions from consumer products contribute to human inhalation exposure and may cause adverse health effects. Existing methods to determine long-term VOC emissions from e.g. building products need to be verified for their suitability to reliably detect initial VOC emissions from consumer products within the first hours and days of use, which would facilitate realistic inhalation exposure assessments. To investigate this issue, VOCs emitted from a test sample were determined in a large-scale emission test chamber and in two micro-chambers of different volumes, and the results were compared.