Graue Literatur
Filtern
Erscheinungsjahr
Dokumenttyp
- Sonstiges (164) (entfernen)
Sprache
- Englisch (90)
- Deutsch (68)
- Mehrsprachig (5)
- Italienisch (1)
Referierte Publikation
- nein (164)
Schlagworte
- Antibodies (7)
- ELISA (7)
- Corona (6)
- Digitalisierung (5)
- MALDI-TOF-MS (5)
- Nanoparticles (5)
- Traceability (5)
- COVID-19 (4)
- Korrosion (4)
- Peptide (4)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (33)
- 6 Materialchemie (25)
- 1.5 Proteinanalytik (23)
- 8 Zerstörungsfreie Prüfung (23)
- 6.1 Oberflächen- und Dünnschichtanalyse (12)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (9)
- 1.8 Umweltanalytik (7)
- 4 Material und Umwelt (7)
- 6.6 Physik und chemische Analytik der Polymere (7)
- 7 Bauwerkssicherheit (6)
Die vorliegende Arbeit beschäftigt sich mit der experimentellen Validierung eingebetteter Sensorik zur pH-Wert Bestimmung basierend auf Fluoreszenspektroskopie.
Bisherige Karbonatisierungsmessungen basieren auf zerstörenden Methoden. Durch das Einbetonieren von immer erreichbaren pH-Sonden wird die Überprüfung zerstörungsfrei.
Um ein fehlerfreies, reproduzierbares Ergebnis zu gewährleisten, mussten diese pH-Sonden zunächst getestet und eine ausreichend präzise Methode zur Messung entwickelt werden.
Durch das Vorgeben unterschiedlicher pH-Milieus und dem Testen verschiedener Messmethoden und Versuchsaufbauten werden Situationen im Beton simuliert.
Hierzu werden die pH-Sonden mit unterschiedlich starken basischen und neutralen Lösungen in Kontakt gebracht, wodurch der in den Sonden befindliche Indikator je nach pH-Wert eine blaue oder orange Färbung annimmt. In den Sonden befindliche Quantenpunkte werden durch einen Laser angeregt. Diese Quantenpunkte fluoreszieren aufgrund der Anregung im blauen und orangen Spektrum. Mithilfe der Fluoreszenzspektroskopie wird die durch den Indikator gefilterte Fluoreszenz in Reflexion und Transmission gemessen. Die Ergebnisse werden genutzt, um ein Verhältnis zwischen den zwei Wellenlängen zu berechnen, anhand dessen zu erkennen ist, welche Farbe der Indikator in den Sonden angenommen hat. Die experimentelle Validierung dient der Optimierung der Methodik, des Versuchsaufbaus und der Zusammensetzung der Sonden. Nach eine Reihe unterschiedlicher Versuche, werden Bedingungen geschaffen, welche zu den gewünschten Ergebnissen führen. Das in Reflexion gemessene Licht kann Aussage darüber geben, welche Farbe der Indikator annimmt und das Verhältnis zwischen dem blauen und dem orangen Spektrum gibt die erwarteten Werte zurück. Die Ergebnisse dieser Arbeit sollen in Betonprobekörpern angewandt werden, um die hier erprüfte Methode in Realbedingungen zu testen.
In vielen Umgebungen, besonders bei hohen Temperaturen, korrosiven Umgebungen oder auf bewegten oder schlecht zugänglichen Flächen, kann die Temperatur nicht oder nur mit nicht akzeptablem Aufwand mit Berührungsthermometern gemessen werden. Diese Umgebungsbedingungen sind unter anderem in der chemischen Industrie, der Lebensmittel-, Metall-, Glas-, Kunststoff- und Papierherstellung sowie bei der Lacktrocknung anzutreffen. In diesen Bereichen kommen Strahlungsthermometer zum Einsatz. Der VDI-Statusreport zeigt typische Anwendungsfelder von nicht radiometrisch kalibrierten Wärmebildkameras und von radiometrisch kalibrierten Thermografiekameras. Um verlässlich mit spezifizierten Messunsicherheiten berührungslos Temperaturen zu messen, müssen die Strahlungsthermometer und Thermografiekameras nicht nur kalibriert, sondern radiometrisch und strahlungsthermometrisch umfassend charakterisiert werden. Auch die optische Materialeigenschaft, der spektrale Emissionsgrad und die Gesamtstrahlungsbilanz (Strahlung des Messobjekts und der Umgebung) sind bei der industriellen Temperaturmessung von großer Bedeutung. In den letzten Jahrzehnten ist dazu ein umfassendes technisches Regelwerk entstanden, das wir Ihnen mit diesem VDI-Statusreport vorstellen. Manche in den Richtlinien beschriebenen Kennwerte mögen abstrakt wirken. In diesem Statusreport zeigen wir an konkreten Beispielen, was diese Kenngrößen für die berührungslose Temperaturmessung bedeuten. Beispiele von Anwendungen zeigen, wo temperaturmessende Thermografiekameras und ausschließlich bildgebende Wärmebildkameras in der Praxis eingesetzt werden. Mit einer Analyse, welche Themen und Anwendungen derzeit besonders intensiv diskutiert werden, versuchen wir Trends für zukünftige Entwicklungen herauszuarbeiten.
Die vorliegende Arbeit beschäftigt sich mit der Methodenentwicklung eines automatischen
Messverfahrens zur akustischen Detektion von Delaminationen in Stahlbeton. Ziel war
das Konstruieren einer Messeinheit, welche mittels eines Zahnrads kontinuierlich auf eine
Stahlbetonoberfläche klopft und den somit einstehenden Körperschall mit einem Richtmikrofon
aufnimmt. Somit können Rückschlüsse über den Zustand des Betons getroffen
werden.
Das Grundkonzept bildet die Frequenzbandanalyse von Audioaufnahmen mittels einer
gefensterten Schnellen Fourier Transformation. Ein auftragen des Frequenzbands über
die gefahrene Strecke bietet die exakte Positionierung einer Fehlstelle. Für die Validierung
der Methodengenauigkeit entstand ein Betonprobekörper mit eingebrachten Fehlstellen,
welche unter mechanischer Anregung durch das Zahnrad ähnlich dumpfe Töne wie eine
reale Delamination erzeugen. Die Ergebnisse der Tonanalyse zeigen eindeutige Frequenzänderungen
beim Übergang von einem intakten zu einen fehlerhaften Bereich.
Im Bauwesen angesiedelt, ist die vorliegende Arbeit besonders für LeserInnen aus dem
Bereich der Zerstörungsfreie Schadensdiagnose interessant.
A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 minute. Due to the glass material's excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nanofiltration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run.
Research and Development in Non-Destructive Testing in Civil Engineering at BAM has de-veloped over more than two decades. Highlights of present research are ultrasound phase array probes, ground penetrating radar applications for the assessment of existing structures and Laser Induced Breakdown Spec-troscopy (LIBS) to determine which chemical elements on the surface of a specimen are. RFID sensor devel-opments for wireless moisture monitoring and data fusion for the combined analysis of sensor data are fast developing areas. In addition, a selection of application cases is briefly described.
Die Pulskompression wird in der Radartechnik eingesetzt, um den Signal-Rausch-Abstand zu erhöhen. Das Ziel ist es die Entdeckungswahrscheinlichkeit eines Nutzsignals bei gleichbleibender Auflösung zu erhöhen. Durch den Einsatz von Barker Codes oder komplementären Golay Codes werden Sendesignale von Luftultraschallanwendungen pulscodiert. Dies ermöglicht in der zerstörungsfreien Prüfung die Inspektion von dickeren Bauteilen, da die Signalenergie durch zeitlich gestreckte Sendesignale bei gleicher Auflösung vergrößert wird.
In dieser Arbeit wird die Pulskompression durch die Einführung von unipolaren Sequenzen zur Pulscodierung für thermoakustische Ultraschallwandler ermöglicht. Der Signal-Rausch-Abstand wird in der Anwendung der Pulscodierung und anschließenden Filterung mit einem signalangepassten Filter in Luftultraschallmessungen mit dem thermoakustischen Wandler und Wandlern aus zellulärem Polypropylen erhöht.
This author interview is by Dr Michael G. Weller, Head of Division 1.5 Protein Analysis at Federal Institute for Materials Research and Testing (BAM). BAM (www.bam.de/en) is a senior scientific and technical institute with responsibility to the German Federal Ministry for Economic Affairs and Energy. Dr Weller's review paper, Quality issues of research antibodies is available for download in Analytical Chemistry Insights.
Homochirality is an obvious feature of life on Earth. On the other hand, extraterrestrial samples contain largely racemic compounds. The same is true for any common organic synthesis. Therefore, it has been a perplexing puzzle for decades how these racemates could have formed enantiomerically enriched fractions as a basis for the origin of homochiral life forms. Numerous hypotheses have been put forward as to how preferentially homochiral molecules could have formed and accumulated on Earth. In this article, it is shown that homochirality of the abiotic organic pool at the time of formation of the first self-replicating molecules is not necessary and not even probable. It is proposed to abandon the notion of a molecular ensemble and to focus on the level of individual molecules. Although the formation of the first self-replicating, most likely homochiral molecule is a seemingly improbable event, on a closer look, it is almost inevitable that homochiral molecules have formed simply on a statistical basis. In this case, the non-selective leap to homochirality would be one of the first steps in chemical evolution directly out of a racemic “ocean”. Moreover, most studies focus on the chirality of the primordial monomers with respect to an asymmetric carbon atom. However, any polymer with a minimal size that allows folding to a secondary structure, would spontaneously lead to asymmetric higher structures (conformations). Most of the functions of these polymers would be influenced by this inherently asymmetric folding. To summarize, simple and universal mechanisms may have led to homochiral self-replicating systems in the context of chemical evolution. A homochiral monomer pool is deemed unnecessary and probably never existed on primordial Earth.
In dieser Arbeit wurden drei verschiedene Nanomaterialien auf ihre Bindungsfähigkeit zu Proteinen untersucht. Zu Beginn standen dabei die Herstellung stabiler Dispersionen der einzelnen Nanopartikel und die Stabilität der gebildeten Konjugate im Vordergrund. Der Nachweis einer erfolgreichen Konjugatbildung, sprich der Beschichtung von Nanopartikel mit Proteinen, wurde sowohl qualitativ mittels DLS-Messungen als auch über quantitative Protein-Bestimmungen erbracht. Für die Quantifizierung konnten verschiedene Methoden eingesetzt werden. Neben der klassischen Vorgehensweise, welche indirekt über die Quantifizierung von ungebundenem Protein im Überstand erfolgt, konnten ihm Rahmen dieser Arbeit verschiedene direkte Bestimmungsmethoden entwickelt werden. So wurden mittels kolorimetrischer Tests, wie dem BCA-Assay und dem Bradford-Assay, Nanodiamantdispersionen mit Hilfe einer Korrekturwellenlänge vermessen und quantifiziert. Ebenso zum Einsatz kam die Methode der Aminosäureanalytik, welche aufgrund ihrer guten Rückführbarkeit auf Aminosäurestandards Ergebnisse mit hoher Richtigkeit generieren kann und ebenso die Detektion kleiner Proteinmengen möglich macht.
Nach den erfolgten quantitativen Betrachtungen wurden die Protein-beschichteten Nanopartikel auf ihre Anwendbarkeit als Analoga von Virus-like Particles (VLP) bei einer Immunisierung zur Gewinnung von polyklonalen Antikörpern gegen humanes Ceruloplasmin in Kaninchen überprüft. Es konnte mittels ELISA gezeigt werden, dass die Konjugate erfolgreich für die Herstellung von Antikörpern eingesetzt werden können und im zeitlichen Verlauf einer Immunisierung eine Steigerung des Antikörper-Titers zu erreichen ist.