Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (436) (entfernen)
Referierte Publikation
- ja (436) (entfernen)
Schlagworte
- Concrete (13)
- Corrosion (13)
- Structural health monitoring (13)
- Simulation (11)
- Thermography (11)
- Ultrasound (10)
- Non-destructive testing (8)
- Compatibility (7)
- Biofuels (6)
- Damage detection (6)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (57)
- 7 Bauwerkssicherheit (21)
- 3 Gefahrgutumschließungen; Energiespeicher (19)
- 8.0 Abteilungsleitung und andere (18)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (14)
- 7.2 Ingenieurbau (13)
- 8.4 Akustische und elektromagnetische Verfahren (13)
- 3.4 Sicherheit von Lagerbehältern (8)
- 3.2 Gefahrguttanks und Unfallmechanik (7)
- 6 Materialchemie (7)
Keeping and improving process and plant safety competence - what is needed, what should be done?
(2013)
In March 2004 with the position paper “Maintaining and improving competence in safety engineering” of the DECHEMA/GVC Research Committee "Safety Engineering in Chemical Plants", an initiative came up against the tendency that more and more process and plant safety (PPS) orientated professorships turn to other more fashionable research topics. The Research Committee was concerned that PPS in both academic teaching and research could suffer a negative development - despite of its importance. In 2009 a corresponding Dutch initiative followed. To bring these both and other similar initiatives together, within the 8th European Congress of Chemical Engineering held in Berlin in September 2011 a two days Special session on PPS competence was jointly organized by EFCE, ProcessNet and EPSC. All presentations and conclusions drawn by the organizers (the authors of this paper) are electronically available.
The paper addresses the before mentioned initiatives, highlights views and results from the ECCE 8’s special session on PPS competence, and indicates steps necessary to be taken and recent developments.
Rubbers are widely used as main sealing materials for Containers for low and intermediate level radioactive waste and as additional component to metal seals in spent fuel and high active waste containers. The save enclosure of the radioactive container inventory has to be guaranteed according to legislation and appropriate guidelines for long term storage periods as well as down to temperatures of -40 °C for transportation. Therefore the understanding of failure mechanisms that lead to leakage at low temperatures is necessary to ensure a proper material choice which is certainly also influenced by additional factors as e.g. the aging behavior.
Cylindrical casks made of ductile cast iron are used for transport, interim storage and final disposal of radioactive waste in Germany. A basic design criterion is the ability to withstand a horizontal drop without impact Binders onto a foundation representative for the real ground of a storage facility. The increasing use of more cost-effective material compositions requires optimized cask geometries to reduce stresses and strains in the cask structure. For example, a non-uniform wall thickness was introduced to reduce maximum wall bending stresses. As a result, the load characteristics changed from line load to point load at bottom and lid side under horizontal drop fest conditions. Hereby, the position of highest stress inside the structure has shifted significantly. This was the reason for a systematic investigation of effects caused by small design changes or small variations of fest conditions. It led to a better understanding of the positions of high local stresses, their time history and maximum value for cylindrical casks under horizontal drop test conditions. Hence, the paper presents the lessons learnt from modeling and simulating such scenarios considering an impact without limiters onto a realistic target.
Data and prediction for the mass burning rate of a tert-butyl-peroxy-benzoat (TBPB) pool fire (pool diameter = 3 m) is presented. The mass burning rates of TBPB fires are up to six times higher and less dependent on pool diameter compared to hydrocarbon pool fires caused by an additional heat release rate due to exothermic decomposition reaction in the liquid phase. This heat release rate is calculated using a 1st order reaction kinetic obtained from micro calorimetric measurements. A new model is derived considering the heat release rate due to the decomposition reaction which is shown to be 100 % of the heat release rate radiated to the pool surface. With the presented model, including also physical quantities, especially the limiting fuel concentration for upward flame propagation, it is possible to predict the mass burning rates of large TBPB pool fires. The predicted values are in very good agreement with the experiments.
Censorship of parts of written text was and is a common practice in totalitarian regimes. It is used to destroy information not approved by the political power. Recovering the censored text is of interest for historical studies of the text. This paper raises the question, whether a censored postcard from 1942 can be made legible by applying multispectral imaging in combination with laser cleaning. In the fields of art conservation (e.g. color measurements), investigation (e.g. Analysis of underdrawings in paintings), and historical document analysis, multispectral imaging techniques have been applied successfully to give visibility to information hidden to the human eye.
The basic principle of laser cleaning is to transfer laser pulse energy to a contamination layer by an absorption process that leads to heating and evaporation of the layer. Partial laser cleaning of postcards is possible; dirt on the surface can be removed and the obscured pictures and writings made visible again. We applied both techniques to the postcard. The text could not be restored since the original ink seems to have suffered severe chemical damage.
Dealing with first corrosion screening experiments to predict the reliability and safety of Germanys first Carbon Capture and Storage site in the northern Bassin of Germany, northwest of the Capital Berlin, laboratory experiments have been established to simulate the particular conditions at T=60 °C, highly saline aquifer water similar to 'Stuttgart Aquifer', but only at ambient pressure. With mounting 2 independent full 2-grade titanium autoclave systems (running up to 250 bar and 300 °C) pressures up to p=100 bar are possible. In 2010 a specific corrosion chamber of 2-grade titanium working up to 100 °C, flowing aqui fer water with different gas mixtures was designed to fit to a high cycle fatigue testing machine. Long term fatigue experiments simulating fatigue crack growth under corrosive environments will soon start. These experiments may not only help engineering a CCS site, but results can be used to improve the maintenance of geothermal energy production sites, especially moved parts such as pumps and shafts.
The CCS technique involves the compression of emission gasses in deep geological layers. To guarantee the safety of the site, CO2-corrosion of the injection pipe steels has to be given special attention when engineering CCS-sites. To get to know the corrosion behaviour samples of the heat treated steel 1.72252CrMo4, used for casing, and the stainless injection-pipe steel 1.4034 X46Cr13 were kept at T=60 °C and ambient pressure as well as p=100 bar for 700 h - 8000 h in a CC 2-saturated synthetic aquifer environment similar to possible geological on-shore CCS-sites in the northern German Basin. The isothermal corrosion behaviour obtained by mass gain of the steels in the gas phase, the liquid phase and the intermediate phase gives surface corrosion rates around 0.1 to 0.8 mm/year at ambient pressure and much lower about 0.02 to 0.2 mm/year at 100 bar where the CO 2 is in its supercritical state. Severe pit corrosion with pit heights around 4.5 mm are only located on the 42CrMo4 steel. Main phase of the continuous complicated multi-layered carbonate/oxide structure is siderite FeCO 3 in both types of steel.
Refinement of the weld metal grain structure can improve the mechanical properties of the weld and decrease the susceptibility to solidification cracking of the weld metal. In this study, commercial Al Ti5B1 grain refiner was used to refine the microstructure of LB (laser beam) and GTA (gas tungsten arc) aluminum welds by inoculation. The grain refiner additions led to a significant decrease in the weld metal mean grain size whereby a transition from columnar to equiaxed grain structure (Columnar to Equiaxed Transition, CET) was observed. The development of both grain size and shape depended upon the base metal (Al alloys 1050A, 5083 and 6082) and upon the welding process. The GTA welding process allowed a more pronounced and a more efficient refinement than in LB welds. Furthermore, the influence of the solidification conditions on the CET was investigated through temperature measurements in the weld metal. The temperature profiles revealed a faster solidification of LB welds than in GTA welds. The results from the temperature measurements were also used to estimate (according to an existing model) the critical thermal gradient at which the CET occurs.
Ultrasonic examination of anisotropic inhomogeneous austenitic welds is challenging, because of the columnar grain structure of the weld leads to beam skewing and splitting. Modeling tools play an important role in understanding the ultrasound field propagation and optimization of experimental parameters during the ultrasonic testing of austenitic welds as well as the interpretation of the test results. In this contribution, an efficient theoretical model based on the ray tracing concepts is developed to calculate the ultrasonic fields in inhomogeneous austenitic welds quantitatively. The developed model determines the ultrasound fields by taking into account the directivity of the ray source, the inhomogenity of the weld as well as ray transmission coefficients. Directivity of the ray source in columnar grained austenitic materials (including layback orientation) is obtained in three dimensions based on Lamb's reciprocity theorem. Ray energy reflection and transmission coefficients at an interface between two general columnar grained austenitic materials are calculated in three dimensions. The ray tracing model predictions on inhomogeneous austenitic weld material are compared against those from CIVA, a commercial non-destructive modeling and simulation tool. The ultrasonic modeling tools in CIVA are based on semi-analytical solutions. For beam propagation simulation, a so-called 'pencil method' is used, which involves modeling the probe as a set of individual source points, each radiating 'a bundle' of diverging rays into the medium and integrating those elementary contributions. Inhomogenity in the weld region is approximated by mapping the grain orientations on weld macrograph. Simulation results for ultrasonic field profiles for an austenitic weld are shown to be in good agreement with the corresponding experimental results.
The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNRmax depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography.
Two research institutes are currently evaluating dynamic pile load testing methods on bored piles in a sandy environment. A test site has been prepared, which ensures comparable conditions at all pile locations and provides detailed knowledge on soil and other boundary conditions. A detailed site investigation program was performed at a dedicated area on the BAM test site south of Berlin, Germany. Undisturbed soil samples have been collected from boreholes. In addition several CPTs and geophysical surveys have been performed. The site consists mainly of well graded, partly well compacted medium sands. But at depth an inhomogeneous gravel layer was detected in some parts of the site. This has led to a redesign of the test piles. They are now shorter than originally intended to avoid gravel layers at depth and to ensure that the drop weight available for dynamic test is capable to mobilize the required load.
Parallel Seismic was introduced about four decades ago for foundation length estimation. As the borehole required by this test is in most cases more expensive than the test itself, the usage is limited so far. In addition the graphical Interpretation technique which is still state of the art tends to overestimate the length and neglects several geometrical Parameters. New Interpretation algorithms have been recently introduced rely on model based travel time curve Utting. They improve the accuracy and extend the maximum ränge (distance pile to borehole) of the method. Borehole or pile inclination as well as soil layering can be considered. If the location is properly chosen, several piles can be tested using a single borehole.
The capabilities and limitations of the methods have been tested using simulations and measurements at the BAM-TTS test site in Horstwalde south of Berlin and several commercial projects involving piles, pile secant walls and sheet piles. To improve the accuracy of the method as well as to provide additional Parameters to the geotechnical engineer it is recommended to use the borehole for Downhole Seismic measurements. Determination of compressional and shear wave velocities can be used to determine the dynamic elastic properties of the subsoil. The approach is evaluated again on the BAM-TTS test site. The affectivity of this kind of combiuation can be further enhanced by using a seismic cone.
A reliability-based approach to inspection planning for welded steel structures subjected to high cycle fatigue is presented in the current document. Inspections are an effective means to control the Progress of fatigue deterioration and the presented approach allows to determine the minimum required inspection effort so that the considered structure complies with the given risk acceptance criteria in terms of target reliability throughout its service life.
The fatigue deterioration modeling for welded steel structures subjected to high cycle fatigue is presented in the current document. The aim of this paper is to formulate approaches based on actual Research results for the phases fatigue crack initiation, fatigue propagation and fatigue failure. The physical characteristics of the approaches are discussed in combination with the associated uncertainties and the probabilistic modeling of this time variant reliability problem. The fatigue deterioration modeling documented here serve as a basis for a reliability-based approach to inspection planning.
Instrumented measurements on radioactive waste disposal containers during experimental drop testing
(2011)
In context with disposal container safety assessment of containers for radioactive waste the German Federal Institute for Materials Research and Testing (BAM) performed numerous drop tests in the last years. The tests were accompanied by extensive and various measurement techniques especially by instrumented measurements with strain gages and accelerometers. The instrumentation of a specimen is an important tool to evaluate its mechanical behavior during impact. Test results as deceleration-time and strain-time functions constitute a main basis for the validation of assumptions in the safety analysis and for the evaluation of calculations based on finite-element methods. Strain gauges are useful to determine the time dependent magnitude of any deformation and the associated stresses. Accelerometers are widely used for the measuring of motion i.e. speed or the displacement of the rigid cask body, vibration and shock events. In addition high-speed video technique can be used to visualize and analyze the kinematical impact scenario by motion analysis. The paper describes some selected aspects on instrumented measurements and motion analysis in context with low level radioactive waste (LLW) container drop testing
The extremely low acoustic impedance of polypropylene ferroelectret combined with its piezoelectric properties makes this material suitable for construction of aircoupled ultrasonic transducers for non-destructive testing. For the fabrication of transducers with a stable quality, the reproducibility of their key parameters is of interest.
The reproducibility was evaluated by means of (i) impedance spectroscopy and (ii) pulse-echo measurements. (i) Impedance spectroscopy was applied to identify the resonance frequency, the coupling factor and the acoustic impedance of several nominally identical transducers. (ii) Pulse-echo measurements yielded the signal form of these transducers.
The variation of the signal amplitude measured with pulseecho technique was about 10 dB. A part of this variation Comes from the deposition of transducer electrodes and another part from local variations of ferroelectret properties. The variation of the signal amplitude was caused by the observed variation of the coupling factor, which was also about 10 dB. The variation of the acoustic impedance was only about 1 dB, thus having no effect on the variation of the signal amplitude.
These results indicate that the variability can be reduced by improving the control of electrode deposition and by optimizing the production technology affecting the reproducibility of material properties.
Transport packages for spent fuel have to meet the International Atomic Energy Agency requirements for different transport conditions. Physical state of spent fuel and fuel rod cladding as well as geometric configuration of fuel assemblies are important inputs for the evaluation of package capabilities under these conditions. In this paper, the mechanical behaviour of high burn-up spent fuel assemblies under transport conditions is analysed with regard to assumptions to be used in the activity release and criticality safety analysis. In particular the different failure modes of the fuel rods (fine cracks or complete breakage), which can cause release of gas, volatiles, fuel particles or fragments have to be properly considered in these assumptions. In view of the complexity of interactions between the fuel rods as well as between fuel assemblies, basket, and cask containment, the exact mechanical analysis of such phenomena is nearly impossible. The gaps in information concerning the material properties of cladding and pellets, especially for the high burn-up fuel, make the analysis more complicated additionally. In this context some practical approaches based on experiences of BAM Federal Institute for Material Research and Testing within safety assessment of packages for transport of spent fuel are discussed.
Some nonlinear optical properties such as the nonlinear refractive index and the nonlinear effective absorption, as well as the laser-induced single-pulse ablation threshold are characterized for a series of binary and ternary silicate glasses upon irradiation with near-infrared femtosecond laser pulses (800 nm, 130 fs). The laser-induced ablation threshold varies from 2.3 J/cm² in case of potassium silicate glass up to 4.3 J/cm² in case of Fused Silica. Nonlinear refractive indices are qualitatively similar within the range 1.7-2.7×10-16 cm²/W. Complementary optical and physico-chemical properties like band gap energy and the glass transformation temperature have been measured for all the glasses.
Limited access to the object of relevance is often an essential problem in testing routines, e.g. for non-destructive testing of industry facilities or components of means of transportation. The presented project is about the development of a non-destructive testing method for application over great distances (up to 100 m). The method is based on directed excitation and measuring of Lamb waves (guided waves). It enables an effective differentiation of structural and defective indications as well as a classification of different defect types.
The advantage of guided waves is the ability of propagation over great distances. This offers innovative possibilities for the investigation of large or difficult to access constructions. The testing method can be helpful in a broad variety of applications. It is useable for the characterization of plane or cylindrical, thin-walled surfaces of metal or fiber laminated materials. Particularly the investigation of aircraft wings and other aerospace components as well as the investigation of pipelines are addressed fields of application.
In this paper the Scaled Boundary Finite Element Method (SBFEM) is applied for the simulation of Lamb waves in cracked plates. This method is highly advantageous to study the interaction of different Lamb wave modes with cracks as the crack is not discretized and no refinement is required around the crack tip. Numerical examples are presented for the reflection of the fundamental symmetric and antisymmetric modes from cracks of different depth. The spatial Fourier transformation is employed to calculate the amplitudes of reflected Lamb wave modes. The results reveal possibilities to obtain details of the crack geometry in non-destructive testing and structural health monitoring applications.
A silicon MIS-structure prepared with thin layers of the super-ionic conductor LaF3 and Pd is used to detect hydrogen. The sensor is able to detect hydrogen in a concentration range from below one ppm to the lower flammable limit in air which is 4 vol.-%. The chip operates at room temperature which results in an extremely low energy consumption compared to other hydrogen sensors. Only once per day a short heating pulse is necessary to reactivate the sensor chip. In cooperation with the BAM, a long-term experiment was carried out. The duration of the measurement was about three months, with a hydrogen exposure every two weeks. The sensor signal remained stable over the measured period.
Schadensfälle in den letzten zehn Jahren mit teilweise katastrophalen Folgen belegen, dass der Vermeidung von Rissen beim Schweißen von Rohrleitungen besondere Aufmerksamkeit zu schenken ist. In der Analyse solcher Schäden ist zu unterscheiden, ob die Risse bereits während oder kurz nach der schweißtechnischen Fertigung der Rohrkomponenten oder während des anschließenden Betriebes entstanden sind. Im vorliegenden Beitrag wird sich vor allem auf die Vermeidung einer Heiß- und Kaltrissbildung beim Schweißen von Rohrleitungen konzentriert und es werden weitere Forschungsperspektiven abgeleitet.
A time domain spectrometer T-ray 2000® operating in the range of 0.2-2 THz was used for Time of Flight measurements. A series of ethanol water mixtures from 10% to 90% were produced subsequently filled in polystyrene cells and analyzed in the T-ray 2000 TDS system in the reflection mode. The reflectivity of the material liquid interface is strongly influenced by the ethanol concentration in water. The reciprocal reflection coefficient of the material liquid interface was found to be a useful discriminating feature for further Probably of Detection calculations which can be used for the performance evaluation of potential THz bottle scanners. THz pulse echo (PE) measurements were performed in comparison to the established ultra sound PE technique for flaw detection of plastics. Synthetic aperture reconstructions were applied for simulated data to reconstruct the flaw shape. The results were compared with B-scan images of a high density polyethylene (HDPE) test cylinder. Existing restrictions on the quality of the back projected images and limits of the existing model are discussed in detail.
Determining scatter ratios at high energies (> ~ 1MeV) presents challenges not immediately obvious from measurements at conventional X-ray energies. This includes reduced attenuation even in heavy elements as well as a stronger forward bias of scattering. In order to check the reliability of different measurement setups with regard to material thicknesses, distances, and collimation, attenuation and scattering were separately simulated using a Monte Carlo model. The simulation results help in understanding the sources of radiation scattered into the detection area, thereby aiding in eliminating undesired contributions.
Cathodic protection (CP) is a common method for rehabilitation of reinforced concrete structures suffering from Chloride induced corrosion. A sufficient protection of the corroding rebar can be ensured by use of several protection criteria. The use of these assessment criteria, in particular the so called 100 mV-criterion, can lead to erroneous resuits for certain unconventional arrangements of rebar and cp anode.
Therefore a joint research project of the Institute for Building Materials Research, RWTH-Aachen University, Germany, (ibac) and the Federal Institute for Materials Research and Testing, Berlin, Germany, (BAM) has been set up to determine the applicability of CP under arbitrary geometrical conditions. A special focus was set on the applicability of surface applied anode Systems for protection of the reinforcement of structures opposite to the accessible side (e.g. outer side of tunnel Shell, Bridge deck protected from inside a box girder) In this paper, the impact of the time dependent changes of the Polarisation behaviour of the rebar on the current and potential distribution is shown by means of parametric studies using the FEM method.
We studied Brillouin gain spectrum characteristics in dispersion-shifted fibers having compound GeO2-doping compositions in the fiber core to realize simultaneous measurement of distributed strain and temperature. Due to various dopant concentration alongside the radius of tested nonzero dispersion-shifted fibers several multiple Brillouin scattering resonances were observed in the stimulated Brillouin spectra arose through backscattering on higher acoustic modes which propagated along the fiber axis. As a result of the varying acoustic velocities, the Brillouin resonance peaks featured different temperature coefficients which can be used to accomplish the simultaneous measurement of fiber strain and temperature. We presented our first measurement results for NZDS Fujikura and LEAF Corning fiber and discussed the superior sensory suitability of the former fiber types.
How do application-related issues influence the reliability of fiber optic strain measurements?
(2011)
Fibre optic strain sensors are increasingly used and sensor systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor's the performance. The contribution will focus on issues that can deteriorate the sensor function or reduce the reliability of measurement results. Aspects are considered how to come to reliable strain measurements and how to validate strain measurements of applied sensors. Related to this topic, European activities like the recently started European COST TD1001 action, called (OfSeSa) will be presented.
Strain measurement in structures witli the purpose of long-term structurai health inonitoring must provide reliable inforination about the structure’s behavior over the whole period of use. The user must be sure that installed sensors are validated and work to the utmost satisfactiou. For this purpose, sensor Systems are tested using special facilities. Bccause it is not easy to characterize the strain transfer quality from the host structure into surface-applied strain sensors, a unique testing facility has been developed. Originally developed for fiber Bragg grating based sensors, the KALFOS facility (= calibration of fiber optic sensors) can also be used for electrical strain sensors.
Calibration ineasurements are referenced by unbinsed Digital Image Correlation (D1C) and Electronic Speckle Pattern Interferometer (ESPI) methods. The strain transfer behavior can experimentally be analyzed and investigated under combined thermal and mechanical loading conditions and allows revealing wealuiesses in couimonly used attachment methodologies. The deformation of all members (particularly the coating/substrate - adhesive combination) in the sensing area is physically independently gained and recorded. Results achievcd allow precise description of the strain transfer function, Validation of the longterm strain sensor characteristics, matching of specific measurement requirements with environmental conditions, and, moreover, the verification of Standards for use of strain sensors.
Claddings of different nickel based alloys were generated on a mild Steel (S235JR) and a stainless steel type 304 by Cold Metal Transfer (CMT). This welding procedure possesses a low degree of mixing between the Substrate and cladding material. Thus it improves the corrosion behaviour of the claddings. The aim of our investigations was to examine the effect of the welding parameters: energy per unit length, shielding gas and finishing surface treatment on the pitting corrosion behaviour of the claddings.
However, under Standard test conditions nickel based alloys are often resistant to pitting corrosion. Moreover these test methods are inaccurate and require a large period of time resulting from the iterative progress to determine the critical pitting temperature (CPT). A potentiostatic test method was modified using a high concentrated CaCI2-solution and a conventional three electrode measuring cell. The pitting corrosion behaviour is calculated from current noise charges. During the test the course of corrosion is detected online by the evaluation of electrochemical noise Signals while a continuous increase of temperature by a defined heating rate is realised.
Thus a critical pitting temperature can be estimated by only one attempt. Furthermore the deviation of the measured CPT is very low compared to Standard tests using gravimetrical and microscopic evaluation. That enables to figure out the influence of the welding parameters in an exact way.
The material parameters melt flow rate MFR, density D, notched impact strength N.I.S. at -30 °C, stress crack resistance FNCT and resistance to oxidative degradation Ox (determined by the increase of MFR) have been selected for a comparison of polyethylene grades for one design type in the “European Standard EN 15507 - Transport packaging for dangerous goods - Comparative material testing of polyethylene grades”. The parameters have a systematic relationship with design type tests. The notched impact strength at -30 °C and the resistance to oxidative degradation of polyethylene grades determined with test specimens of compression moulded sheets are directly comparable with drop tests at -18 °C of design types produced of these grades after pre-storage with 55 % nitric acid for 21 days at 40 °C. The impact of the pre-storage time of jerricans with 55 % nitric acid at 40 °C and 23 °C on the marginal drop heights in drop tests at -18 °C, on the MFR and on the tensile properties tensile strength, breaking elongation and the elastic modulus were investigated. Packaging design types (jerricans) made of three polyethylene grades from different producers were pre-stored with 55 % nitric acid for 21,42 and 84 days at 40 °C as well as for six months at 23 °C. The MFR and tensile properties of test specimens taken from the design type side walls as well as the marginal drop heights of the jerricans in drop tests at -18 °C were determined.
The values of the notched impact strength at -30 °C of polyethylene grades are not comparable with the marginal drop heights determined in drop tests at -18 °C. The oxidative damaging impact of nitric acid has a greater effect on the grade with lower resistance to oxidative degradation by reducing more significantly the marginal drop heights with increasing pre-storage time.
Pre-damage with 55 % nitric acid for 21 days at 40 °C, as recommended in ISO 16101 and EN 15507 caused an increase in the marginal drop heights of most design types in drop tests when compared with design types without pre-damage. The test results demonstrated clearly that pre-storage of the jerricans for six months at 23 °C caused a higher increase in the MFR and lower marginal drop heights of the jerricans in drop tests at -18 °C compared with pre-storage of the jerricans for 21 days at40 °C.
The mechanical properties change as a result of diffusion of nitric acid into the polyethylene grades and the reaction of the nitric acid with the polymers. The percentage decrease and increase in the tensile strength, breaking elongation and elasticity modulus of test specimens taken from the design type side walls after different pre-storage times were only partly comparable with the marginal drop heights in drop tests at -18 °C.
The debonding of a fiber in a glass fiber / epoxy composite under transverse loading is studied. The stress field in the interface as well as the energy release rate are analysed for two fiber volume fractions.
The circumferential propagation of an Interface crack starting at the center of a fiber which is located within a hexagonal fiber array is studied. The analysis is performed by a finite element Simulation under plane stress conditions. Two fiber volume fractions are considered, this is 30% and 70%. The stress distribution before and during crack propagation is calculated for different stages of the
crack. The crack opens by dominating tensile stresses in the first phase while it closes when propagating along the interface. The total energy release rate as well as the mode I and mode II parts are calculated. In the first phase the crack is driven by an increasing mode I energy release rate, indicating an unstable crack propagation. Then the mode II energy release rate increases rapidly and dominates the debonding process while the mode I part decreases and finally vanishes. Subsequently also the mode II part decreases, indicating stable crack propagation. In the last phase the crack becomes unstable again due to a strongly increasing mode I energy release rate. During the debonding process a remarkable change the mode ratio takes place.
The main features of the debonding process are similar for low and high fiber volume fraction. In case of the high fiber content, however, the mode I part is more pronounced and the maximum of the total energy release rate is shifted to lower crack angles.
A time domain spectrometer in the range of 0.5–2 THz was used for time of flight (ToF) measurements of THz pulses for imperfection detection in non metallic materials. The measurements were performed in comparison to the established ultra sound pulse echo (PE) and time of flight diffraction (ToFD) technique. No coupling agent and no contact to the surface is required for THz ToFD measurements. Plastic test specimen with notches, voids and drilled side holes were used to study reflected and diffracted response signals. No major differences were observed between the UT and THz ToFD records for the first surface of the notches, voids and holes. Additionally to the UT records also signals were obtained from its back side and a second raw of holes. The THz measurement is fast and has the potential to substitute UT applications in some industrial areas. Within the German project 'Handheld' the potential for miniaturization of the time domain equipment is explored for efficient application.
Risikobasierte Überwachungsverfahren zur Lebensdauerverlängerung von bestehenden und neuen Bauwerken
(2011)
Diese Veröffentlichung enthält Konzepte zur Lebensdauerverlängerung von Bauwerken auf der Grundlage der Tragwerkszuverlässigkeitstheorie. Es werden aktuelle Forschungsergebnisse aus nationalen und europäischen Forschungsvorhaben vorgestellt. Den Schwerpunkt bildet die Verwendung von Bauwerksüberwachungsdaten unter Berücksichtigung von Messunsicherheiten zur Bestimmung der Tragwerkszuverlässigkeit. Dazu wird ein neuer Ansatz zur Bestimmung der A-posteriori Messunsicherheit vorgestellt. Es wird gezeigt, aufgrund welcher Eigenschaften der verwendeten probabilistischen Modelle die Zuverlässigkeit im Grenzzustand der Ermüdung in Bezug auf eine Lebensdauerverlängerung beeinflusst werden kann.
Dry cask storage of spent fuel and high active waste front reprocessing is licensed and established in Germany for up to 40years so far. About 10years ago, the strategy has been shifted from centralized storage using facilities in Ahaus and Gorleben to cit-site storage facilities in Order to avoid immediate cask shipping from nuclear power plants. At present, several hundred casks are stored safeiy and without any major problem. BAM is highly involved in cask specific safety evaluations within the scope of licensing procedures as well as of quality assurance procedures during cask fabrication, loading and storage.
A major prerequisite for any cask storage license is a valid transport Type B license. Subsequently, cask transportability has to be ensured at any point during the entire storage period. So far, this requirement is met by continuous maintenance of the Type B license. Anyhow, IAEA Type B regulations do not consider permanently loaded storage casks that have the sole purpose of being finally shipped öfter decades of storage inducing ageing effects. No transport safety demonstration has to be performed on aged cask components.
With CO2 being one reason for climate change carbon capture and storage (CCS) is discussed to mitigate climate change. When emission gases are compressed into deep geological layers CO2-corrosion can easily cause failure of injection pipes. Different steels 42CrMo4, X46Cr13 and X20Cr13 were tested as well as X35CrMo17 and X5CrNiCuNb16-4 in a laboratory Environment similar to the conditions of the CCS engineering site at the Northern German Bassin. Samples were exposed to synthetic aquifer water saturated with technical CO2 at a flow rate of 3 NL/h.
Corrosion rates obtained via mass loss vary in a wide range (0,005 to 2.5 mm/year). The precipitations within the corrosion scale revealed a complicated multiphase layer containing siderite FeCO3, goethite α-FeOOH, lepidocrocite γ-FeOOH, mackinawite FeS and akaganeite Fe8O8(OH)8Cl1,34 and spinelphases of various compositions.