Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (2605) (entfernen)
Sprache
- Englisch (1886)
- Deutsch (709)
- Mehrsprachig (5)
- Russisch (3)
- Tschechisch (1)
- Portugiesisch (1)
Schlagworte
- Concrete (74)
- Corrosion (62)
- Structural health monitoring (41)
- Simulation (36)
- Monitoring (32)
- Steel (27)
- Korrosion (25)
- Laser beam welding (25)
- Ultrasound (25)
- Drop test (23)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (276)
- 7 Bauwerkssicherheit (255)
- 9 Komponentensicherheit (206)
- 3 Gefahrgutumschließungen; Energiespeicher (146)
- 9.3 Schweißtechnische Fertigungsverfahren (84)
- 4 Material und Umwelt (72)
- 7.2 Ingenieurbau (71)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (71)
- 5 Werkstofftechnik (63)
- 8.4 Akustische und elektromagnetische Verfahren (60)
Paper des Monats
- ja (1)
Mit der Abkehr von der Nutzung fossiler Rohstoffe rücken regenerative Energieträger immer weiter in den Focus. Neben klassischen Holzkohlen werden verstärkt so genannte Biokohlen produziert. Dieser Begriff findet Verwendung für mit Hilfe verschiedener Verfahren karbonisierte pflanzliche, tierische oder mikrobielle Ausgangsstoffe. Diese Kohlen werden zum Teil über weite Strecken zum Bestimmungsort transportiert (Überseetransporte) oder vor Verwendung für längere Zeit gelagert.
Häufig zeigen diese Kohlen ein kritisches Selbstentzündungsverhalten, wobei Einstufungstests (UN N.4 Test) versagen können. Ein negatives Testergebnis des UN N.4 Tests führte dabei in der Vergangenheit zur Nichteinstufung als selbsterhitzungsfähiger Stoff; in der Praxis entzündeten sich aber bereits vergleichsweise kleine Schüttungen (einige m³), z. B. beim Seetransport in Containern. Der Artikel geht auf dieses Problem ein und stellt Prüfverfahren vor. Aus den Ergebnissen durchgeführter Untersuchungen werden Empfehlungen für sicheren Transport und Lagerung abgeleitet.
In einer Versuchsreihe im Realmaßstab wurden drei Flüssigwasserstofftanks (LH2) unterfeuert. Hierbei sollte unter anderem geklärt werden, ob es, analog zu druckverflüssigten Gasen, zu einem BLEVE (Boiling Liquid Expanding Vapor Cloud Explosion) kommen kann. Die Experimente wurden auf dem Testareal Wasserstoffsicherheit des Testgeländes Technische Sicherheit der Bundesanstalt für Materialforschung und -prüfung (BAM-TTS) im Rahmen einer Forschungskooperation zwischen der BAM und Gexcon, als Teil des SH2IFT-Programms durchgeführt. Es handelte sich um doppelwandige, vakuumisolierte Tanks von 1 m³ Volumen. Die zylindrischen Tanks unterschieden sich durch ihre Ausrichtung (horizontal oder vertikal) und das verwendete Isoliermaterial (Perlit oder Mehrschichtisolierung (MLI). Der Füllgrad der Tanks betrug bei jedem der durchgeführten Tests etwa 35-40 %. Die Brandlast wurde homogen durch ein propangasbetriebenes Brennersystem erzeugt. Gemessen wurden die Bedingungen im Behälter (Temperaturen und Druck) sowie äußere Randbedingungen und Auswirkungen beim Versagen (Wärmestrahlung, Druckwellen, Flammenballentwicklung und Fragmentierung). Mit Bolometern wurde die Wärmestrahlung gemessen, die sowohl durch das Propanfeuer als auch durch einen möglichen Feuerball/BLEVE erzeugt wurde. Zur Messung der durch das Bersten von Behältern/BLEVEs erzeugten Druckwellen wurden sog. Pencil-Probes verwendet. Des Weiteren wurden mehrere Kameras zur Überwachung der Experimente eingesetzt: Normalbildkameras, Infrarot (IR)-Kameras und Hochgeschwindigkeitskameras, sowohl bodengestützt als auch mittels einer Drohne. Zwei der untersuchten Tanks, ein horizontaler und der vertikale, die beide mit Perlit isoliert waren, hielten der Brandbelastung stand, ohne dass es zu einem Behälterversagen kam. Der mit MLI isolierte horizontale Behälter barst nach 1 Stunde und 6 Minuten und erzeugte dabei einen Feuerball, Trümmerflug und eine Druckwelle. Neben der Beschreibung der Auswirkungen eines kritischen Versagens eines LH2-Tanks sind weitere Ziele der Arbeit die Identifizierung kritischer Behälterzustände sowie die Erstellung eines umfassendes Datensatzes der Trümmer des geborstenen Tanks. Die größten Abstände für kritische Abstände ergaben sich durch Fragmentwurf. Hier sollen 3D-Scans für die Verwendung in CAD und FEM Anwendungen bereitgestellt werden. Umfassende Daten zu den Fragmentwurfweiten, -massen und -positionen wurden bereits publiziert. Damit soll die Voraussetzung geschaffen werden, um vorhandene Wurfweitenmodelle, die bisher nur für einschalige Behälter konzipiert wurden auf ihre Eignung für mehrschalige Behälter zu überprüfen oder mögliche Anpassungen anhand der realen Daten vornehmen zu können.
Zudem wurde damit begonnen die nicht geborstenen Tanks zu vermessen und zu zerlegen, um u.a. die Perlit-Schüttung auf Beeinträchtigungen durch den Transport und die Unterfeuerung zu untersuchen.
In einer Reihe von Experimenten wurden die möglichen Folgen der Freisetzung von verflüssigtem Wasserstoff (LH2) auf, bzw. unter Wasser untersucht. Die Experimente zielten darauf ab, eine unbeabsichtigte Freisetzung von LH2 (z.B. durch Schlauchabriss) insbesondere bei der Betankung eines Schiffes zu simulieren. Für verflüssigtes Erdgas (LNG) wurden dabei sog. RPT’s (rapid phase transition) nachgewiesen, bei denen die spontane Verdampfung relevante Druckwellen erzeugt. Es kann nicht ausgeschlossen werden, dass RPTs auch im Falle von LH2 möglich sind. Die Versuche wurden auf dem Testareal Wasserstoffsicherheit auf dem Testgelände Technische Sicherheit der Bundesanstalt für Materialforschung und -prüfung (BAM-TTS) in Horstwalde, im Rahmen einer Forschungskooperation zwischen der BAM und Gexcon im Rahmen des SH2IFT-Programms durchgeführt. Die LH2-Freisetzungen erfolgten direkt aus einem LH2-Tanklastwagen über eine lange, flexible, vakuumisolierte Transferleitung. Während die Freisetzung oberhalb und unterhalb der Wasseroberfläche jeweils vertikal orientiert war, wurde bei der Unterwasserfreisetzung zusätzlich eine horizontale Ausströmung, parallel zur Wasseroberfläche realisiert. Zur Bestimmung des Massenstromes, wurde ein Wägesystem unter dem Tankwagen eingesetzt. Spezielle Drucksensoren wurden verwendet, um die durch die Freisetzungsvorgänge erzeugten Stoßwellen sowohl im Wasser als auch in der Luft zu messen. Die Gaskonzentrationen über dem Wasserbecken wurden an verschiedenen Positionen gemessen. Hochgeschwindigkeits-, Infrarot- (IR) und normale Kameras wurden eingesetzt, um die Phänomenologie der Freisetzung aufzuzeichnen und das Verhalten der Gaswolke im Zeitverlauf zu verfolgen. Neben den fest installierten Systemen an Land, kamen auch Unterwasserkameras sowie eine Drohne mit Normal- und IR-Kameras zum Einsatz.
Zwei Wetterstationen wurden zur Messung von Windgeschwindigkeit, Windrichtung, Temperatur und Luftfeuchtigkeit während aller durchgeführten Tests eingesetzt. Des Weiteren kamen Bolometer zur Wärmestrahlungsmessung zum Einsatz. Zwar führten die Freisetzung zu einer hochturbulenten LH2/Wasser Mischzone, jedoch zu keinen nennenswerten Überdrücken durch RPT. Im Gegensatz dazu wurde unerwartet, aber reproduzierbar, eine Zündung der Gaswolke in freier Luft in einiger Entfernung von den Instrumenten und dem Ort der Freisetzung beobachtet. Die daraus resultierenden Gaswolkenexplosionen führten zu relevanten Überdrücken und zur Wärmeabstrahlung in die Umgebung.
Evaluation of Heat Fluxes in Fire Reference Test Conducted in BAM Propane Gas Fire Test Facility
(2024)
Packages for the transport of intermediate- and high-level radioactive waste are designed to withstand severe accidents. The International Atomic Energy Agency (IAEA) has established specific mechanical and thermal tests. Packages for the transport of radioactive material must withstand these tests to comply with the Regulations for the Safe Transport of Radioactive Materials IAEA [IAEA (2018)]. A fire reference package was developed with the primary objective to demonstrate that the fire meets the regulatory requirements. Another aim is to characterise the boundary conditions of the actual fire as input parameters for thermo-mechanical simulations. A simple method to characterise the boundary conditions of a real steady state fire with a fire reference package is presented. The thermal test mainly consists of a 30 minute fully engulfing 800°C pool fire or an equally severe fire, such as a propane gas fire. The fire reference tests are performed prior to the actual fire test with the real package. The heat fluxes into the package depend substantially on the fire characteristics and the surface temperature of the package. To investigate local and overall heat fluxes over a wide range of surface temperatures in this test facility a fire reference package was designed for repeated use. The fire reference package presented in this paper represents the outer geometry of a small transport container for radioactive material and is used as a device in civil engineering. It is designed as a closed steel sheet cylinder with a wall thickness of 10 mm, a length of 182 mm and a diameter of 102 mm. The package was instrumented with thermocouples and filled with heat resistant insulation material. Open-air fire tests were performed in a BAM propane gas fire test facility with the fire reference package. The measured temperatures are used to determine the changes of heat fluxes into the fire reference package in relation to the package surface temperature. The calculated heat fluxes allow its fitting to express the thermal exposure as simple mathematical boundary condition. Therefore, in a first approach, fire properties such as adiabatic surface temperature (AST) as proposed by Wickström et al. (2007), convection coefficient and emissivity are determined mathematically fitting the heat flux development presented in this paper. The evaluated results provide an initial picture of local fire characteristics of the conducted propane gas fire and are a further development of previous works from Feldkamp et al. (2020). The results can be used in thermal and thermo-mechanical models to simulate the load on the real transport package in fire. The test shows that the examined propane gas fire covers the IAEA-fire over a wide range of surface temperatures with the chosen test stand parameters.
Mechanical stress often accelerates the failure of polymer materials. The aim of this research is to study the interaction between the sealing material FKM and biofuels B10 (heating oil with 10% biodiesel). The mechanical stress test was carried out in a special apparatus. Both mechanical and non-mechanical stress tests were conducted on specimens at 20, 40, and 70 °C for 28 days to document changes in mass, volume, and tensile properties. Both increasing temperature and mechanical stress have a significant effect on the tensile strength of the FKM polymer when exposed to B10. The combination of increasing temperature and mechanical stress induced rupture within 2 h. It was also established that FKM polymer with pre-exposure in B10 survived longer during mechanical stress compared to specimens exposed only to air. With the support of infrared (IR) spectroscopy, we were able to confirm the penetration of B10 into the FKM polymer.
Portland cement is one of the principal sources of anthropomorphic CO2 emissions. It is estimated that cement production contributes up to 10% of greenhouse gas emissions and annual cement production over 4 billion tons. This has led to the development of a range of alkali activated materials (AAM), the most common precursor materials being class F fly ash and blast furnace slag. At present Class C Fly Ash is not widely utilized as an AAM due to the chemical composition and activation requirements. However, initial research on high Calcium German Class C Fly Ash suggests that the material may have potential for application as an AAM. This paper reports the development of ambient cured alkali activated mortar optimised by varying the alkali modulus and w/b ratio. The evolution of the mechanical and microstructural properties is reported over the initial 28 day period. Compressive strength in excess of 10 MPa at 7 days and 15 MPa at 28 days was achieved at ambient temperature. Similar strengths were observed for both 10% and 15% dosage but as dosage increases the optimal Alkali Modulus reduces.
Water management in proton-exchange membrane fuel cells (PEMFCs) is critical for efficient operation. However, in-situ measurements of the water distribution in an operating PEMFC are challenging. In this study, we investigate key aspects of ultrasonic guided wave (UGW) propagation through the bipolar plate of a PEMFC using 3D scanning laser Doppler vibrometry (3D LDV). Our results provide insights for the design and optimization of UGW-based sensor systems for water detection in PEMFCs.
Im laufenden Verbundprojekt MCGUSS untersuchen dieProjektpartner MPA Stuttgart und BAM Berlin das probabilistische Master Curve (MC) Konzept nach ASTM E1921 hinsichtlich seiner Übertragbarkeit auf ferritisches Gusseisen mit Kugelgraphit (DCI).
Ziel des Projektes ist die Entwicklung einer Methode zur Bestimmung und Bewertung der dynamischen Bruchzähigkeit von DCI im Übergangsbereich. In diesem Beitrag werden die Eigenschaften des verwendeten Werkstoffs der Festigkeitsklasse GJS-400 vorgestellt und die sich daraus ergebenden Probenentnahmestellen näher erläutert.
Weiterhin werden erste Ergebnisse der C(T)25-Versuchsserien vorgestellt, die bei Belastungsraten von ca. 5∙103 MPa√ms-1, 5∙104 MPa√ms-1 und 5∙105 MPa√ms-1 und einer Temperatur von -40 °C durchgeführt wurden.
In einem laufenden Kooperationsprojekt zwischen der BAM Berlin und der MPA Stuttgart wird das probabilistische Master Curve (MC) Konzept nach ASTM E1921 hinsichtlich seiner Übertragbarkeit auf ferritisches Gusseisen mit Kugelgraphit (DCI) untersucht.
Zielsetzung ist die Bereitstellung einer Vorgehensweise zur Bestimmung und Bewertung der dynamischen Bruchzähigkeit von DCI im Übergangsbereich. In diesem Beitrag wird der Versuchswerkstoff der Festigkeitsklasse GJS-400 näher vorgestellt.
Ferner werden erste Ergebnisse von zwei bruchmechanischen Versuchsserien an SE(B)140-Großproben bei Belastungsraten von ca. 6∙104 MPa√ms-1 bei -40 °C und -60 °C präsentiert.
Large-scale experiments have been performed to investigate the possible consequences of realistic amounts of liquified hydrogen (LH2) encountering water. The experiments aimed at simulating an accidental release of LH2 during especially the fuelling of a ship. For liquified natural gas (LNG) it has been demonstrated that when spilled onto water the evaporation rate can be that high that physical explosions occur which are referred as rapid phase transitions (RPTs). It cannot be excluded that RPTs are also possible in the case of LH2. The tests were performed in a 10 m x 10 m x 1.5 m basin filled with water, at the Test Site Technical Safety of the Bundesanstalt für Materialforschung und –prüfung (BAM) in Horstwalde, Germany within a research cooperation between BAM and Gexcon as part of
the SH2IFT program. LH2 releases were established releasing directly from a trailer carrying LH2 through a long flexible double vacuum insulated transfer line. The releases occurred from a height of 50 cm above and 30 cm under the water surface both pointing downwards and 30 cm under the water surface pointing along the water surface too. The release rate was determined based on the weight loss rate of the road tanker which was placed onto load cells. Special blast pressure sensors were used to measure the shock waves generated by the release processes both in the water and in the air. At several locations the gas concentration was measured. Heat radiation was measured at 3 distances from the point of release. High speed,
Infrared (IR) and normal cameras were used to record events and to follow the gas cloud behaviour in time. This includes cameras mounted on a UAV and underwater cameras. Two weather stations were used to measure wind speed, wind direction, temperature and humidity during all tests performed. All investigated release configurations resulted in a very chaotic LH2-water mixing zone, causing considerable evaporation but only minor over pressures.
The main phenomenon observed was an ignition of the released gas cloud, resulting in significant blast wave overpressures and heat radiation to the surroundings. The location of the ignition occurred in free air at some distance from the instrumentation and release location.
Large Scale Experiments have been performed to determine whether a storage vessel containing liquid hydrogen (LH2) and caught in a fire engulfing the vessel can result in a BLEVE (Boiling Liquid Expanding Vapour Explosion) and if so its consequences. The tests were performed at the Test Site Technical Safety of the Bundesanstalt für Materialforschung und –prüfung (BAM) in Germany at the Hydrogen Test Area (H2TA) within a research cooperation between BAM and Gexcon as part of the SH2IFT program. Three tests were performed using double-walled vacuum insulated vessels of 1 m3 volume. The cylindrical Vessels differed in orientation (horizontal or vertical) and the insulation material used (perlite or multi-layer insulation (MLI)). The degree of filling of the vessels was approximately 35-40 % in each of the tests performed. The fire load was provided by a propane fed burner-system positioned under the storage vessel and designed to give a homogeneous fire load. The conditions in the vessel (temperatures and pressure) as well as external effects (heat radiation, blast waves, flame ball development and fragmentation) were measured. All vessels were equipped with K-type thermocouples at several locations at the inner and outer vessel shell. The pressure inside the inner vessel and in the space between the inner and outer vessels (vacuum pressure) was measured. Bolometers were used to measure the heat radiation generated by both the propane fire and that generated by a possible fireball/BLEVE. To measure blast generated by the vessel burst/BLEVEs blast pencils were positioned at up to three locations. Further several cameras were used to monitor the events: normal cameras, infrared (IR)-cameras, high-speed cameras also on board of an UAV. Two of these vessels, a horizontal and a vertical vessel both insulated with perlite withstood the fire loading for 1 hour 20 minutes and 4 hours respectively without catastrophic failure. A horizontal vessel insulated with MLI failed by bursting after 1 hour and 6 minutes resulting in a fireball, fragments, and blast wave.
The safety demonstration of heavy weight type B transport packages used for storing spent nuclear fuel (SNF) or radioactive waste is ensured by a combination of physical testing and numerical calculations. While experiments are performed in accordance with the IAEA regulations for selected drop scenarios, Finite-Element-Method (FEM) simulations are used to predict the most damaging case and to investigate additional drop positions. BAM as competent authority in Germany has performed different investigations of a welding seam for a typical large transport package made of A508 forged steel, where the bottom plate is welded to the cylindrical shell. The package has a mass of approx. 120 t. Results of physical drop tests with a full-scale model and accompanying preliminary FEM simulations are presented to determine the decisive stresses in the welding seam. A drop test only represents one set of a package and test parameters. A further parameter analysis is considered to account for allowable variations of packaging properties (e.g. resulting from the manufacturing process) and, based on IAEA requirements, the temperature dependence of the material behaviour. The results of the stress analyses from the drop test and the simulation form the basis and provide the input parameters for a fracture mechanics analysis. In addition to the IAEA specifications, further standards are taken into account for an in-depth investigation, see R6 [1], BS 7910 [2] and API 579-1/ASME FFS1 [3]. All the above-mentioned standards require a manufacturer-specific defect analysis with respect to size and position. Both result from the welding process and the following heat treatment regime. The maximum defect sizes are ensured with non-destructive test methods (such as ultrasonic or particle methods) as integral part of the manufacturing process of the welding seam. Another important parameter in the welding process is the residual stress (secondary stress). The combination of the primary and secondary stress determines the total stress in the welding seam. The most damaging case of the welding seam is determined and evaluated with help of the abovementioned standards and taking into account the IAEA requirements with respect to defect sizes, material properties, primary and residual stress, yield strength etc.
Mikrolegierungselemente, wie Nb und Ti, sind für die signifikante Festigkeitssteigerung von vergüteten, hochfesten Feinkornbaustählen mit einer Nominalstreckgrenze ≥ 690 MPa unerlässlich. Normvorgaben zur chemischen Zusammensetzung geben dabei nur obere Grenzwerte für die Hersteller vor. Weiterhin wirken sich bereits kleine Abweichungen in der Legierungsroute teilweise drastisch auf die mechanischen Eigenschaften aus. Somit wird eine adäquate Vorhersage der Schweißeignung und der Integrität der Schweißverbindung aufgrund der variierenden Mikrogefüge erschwert bis unmöglich. Unerwünschte Nebeneffekte sind die mögliche Erweichung der Wärmeeinflusszone (WEZ) als auch der gegenteilige Effekt der Aufhärtung. Vor diesem Hintergrund werden erstmals systematisch die unterschiedlichen Mikrolegierungsrouten mit variierenden Ti und Nb-Gehalten an Versuchsschmelzen untersucht. Die Stahlgüte S690QL bildet dabei die Grundlage der chemischen Zusammensetzung sowie der entsprechenden Wärmebehandlung. Zur Untersuchung der jeweiligen Schweißeignung wurden Dreilagen-Schweißungen mittels moderner MAG-Hochleistungsschweißprozesse durchgeführt und kritische Gefügebereiche mit hoher Erweichung/Aufhärtung identifiziert. Der Fokus der analytischen Betrachtungen lag hier auf der Identifikation der Phasenumwandlungen beim Abkühlen und auf dem metallurgischen Ausscheidungsverhalten. Zusätzlich wurden isotherme und nicht-isotherme Phasenberechnungen mit der Software Thermo-Calc durchgeführt. Mechanisch-technologische Untersuchungen zur Kerbschlagzähigkeit mittels Kerbschlagbiegeversuchen durchgeführt wurden, bestätigen dabei die Ergebnisse der thermodynamischen Simulation bezüglich des Ausscheidungsverhaltens während der Temperatur-Zeit Schweißzyklen. Daraus lässt sich der Einfluss der Wärmeeinwirkung beim Schweißen auf die Gefügeausbildung in der WEZ und der korrespondierenden mechanischen Eigenschaften qualitativ beschreiben.
A semi-automatic thermographic procedure for the assessment of the welded area of resistance projection welded joints has been developed. Currently, to assess the quality of RPW joints destructive tests are used and the more commonly used non-destructive technique is the ultrasonic one. The possibility for a quantitative evaluation of the welded area by thermographic technique has been proved by means of an innovative procedure applied on steel RPW joints with ‘as it’ surface conditions. Measurements obtained by thermography and ultrasound have been compared, to verify the developed procedure.
Experimental and numerical investigation of prestressed bolt connections under lateral displacements
(2022)
The containment system of transport packages for spent nuclear fuel and high-level waste usually includes bolted lids with metal gaskets. The packages are assessed to specific transport conditions which are specified in the IAEA safety standards SSR-6 (IAEA 2018). These transport conditions, especially the so-called accident conditions of transport, imply high dynamic loading on the lids and the bolt connections of the package. The response of the lid systems on the mechanical accident conditions is generally investigated by experimental drop tests or numerically, e.g., by finite element analyses. The interpretation of the drop test results for the verification of the numerical models is often not obvious due to the complex superposition of different effects in the real tests. BAM has started a research project to get a better understanding about the behavior of prestressed bolt connections under loadings typical for these drop tests. In this context an experimental test set-up was developed to investigate the response of a single bolt connection under a prescribed lateral displacement of clamped parts. The bolt is instrumented by strain gauges to get the pretensional, the torsional and the bending stress in the bolt shank. Furthermore, the lateral movement and the tilt of the bolt head is measured during the test. A finite element model of the test set-up has been created in Abaqus FEA (Simulia 2021). The very detailed instrumentation of the test set-up shall give the opportunity to investigate and validate the numerical model. The aim of this paper is to give an overview about the proposed research project and to present first results.
The development of a Lab-on-a-Chip (LoC) is presented, which can detect reactive phosphorous compounds in the gas phase in combination with an optochemical hand-held sensor. The LoC prototype contains three pairs of sensing materials containing fluorescent indicator dyes in various carrier materials. By measuring the fluorescence response to phosphoryl chloride, a surrogate compound, the detection of chemical warfare agents (CWAs) in gas phase becomes possible within seconds, introducing a novel approach to CWA detection.
Der Modifizierte Varestraint-Transvarestraint-Test wird an der Bundesanstalt für Materialforschung und -prüfung als Variante des Varestraint-Tests verwendet. Die Auswertung dieser Tests findet klassisch durch Abmessungen der entstandenen Risse unter dem Lichtmikroskop statt. Eine solche Auswertung ist aufwendig und fehleranfällig. Convolutional Neural Networks können trainiert werden, um die Risse auf digitalen Bildern zu segmentieren, wodurch der menschliche Fehler in der Auswertung eliminiert werden kann. Die Ergebnisse können durch Overlay mit den Originalbildern verglichen werden.
The European Commission adopted an EU
Energy Label for smartphones and tablets in June 2023. For the
first time, the EU Energy Label will depict, among energy
efficiency, also a reparability score, battery endurance, battery
lifetime, drop resistance and dust and water ingress protection.
However, does the multitude of parameters bear the risk to
confuse consumers instead of triggering environmentally
sustainable purchase decisions? In a survey in Germany,
consumers were asked to make a choice when the label does not
clearly identify the environmentally better product. Instead,
energy efficiency has to be valued against reparability,
reliability against energy efficiency, and reparability against
reliability. The sustainability lever of the different aspects is not
the same, as e.g. lifetime extension has a much more positive
environmental impact than energy efficiency in case of mobile
devices. Therefore, the question remains, whether consumers
intuitively make the right choice. Results of the survey indicate
that consumers interpret the complex label in the desired
manner and value those aspects higher, which indeed have a
more positive effect on the environment.
Experimental Setup for the Reproducible Generation of Pressure Waves in Free Field Conditions
(2023)
The injuries caused by the primary blast are still poorly understood, especially in the torso region. To generate sufficiently large data sets, shock tubes are often used. However, these have some limitations, such as blockage, use of the exit jet, widening cross-sections, and scaling problems with respect to compressive strength and test objects. Therefore, it is appropriate to conduct experiments under free-field conditions, but tests with real explosives are often associated with long preparation and setup times as well as high safety requirements.
Therefore, this paper presents an experimental setup for the reproducible generation of blast waves under free-field conditions. This experimental setup aims to provide a test environment for a sufficiently large specimen to investigate the behaviour of the shock wave within the specimen, especially at the media interfaces. As an example of application, the influence of the primary explosive effect on protective equipment or on tissue simulants for the investigation of blast injuries can be mentioned. An autoclave is used as a shock wave generator. It has a volume of 0.065 m3 and is filled with a stoichiometric acetylene-oxygen gas mixture. The setup and turnaround time is approximately 30 minutes. The following factors have been selected as target variables for the optimization of the shock wave generator: reproducibility of the pressure wave, use-case-relevant positive phase duration and peak overpressure, a pressure curve characteristic corresponding to that of a military explosive under undisturbed free field conditions, and short setup times of the experimental setup. For this purpose, the experimental setup is presented in this paper. Several series of measurements are presented, showing the characteristics of the generated pressure wave. For the generated pressure wave, the classical pressure curve characteristics can be clearly recognized. A peak pressure of 92 kPa is reached at a distance of 1 m from the opening, and the first positive pressure phase lasts 1.17 ms. Furthermore, the pressure wave propagates in a hemispherical shape. The typical characteristics of the blast wave generated by the SWG have been demonstrated using the military explosive PETN. It is shown that the actual load case corresponds to about 70 g of PETN.