Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (2610) (entfernen)
Sprache
- Englisch (1889)
- Deutsch (711)
- Mehrsprachig (5)
- Russisch (3)
- Tschechisch (1)
- Portugiesisch (1)
Schlagworte
- Concrete (74)
- Corrosion (62)
- Structural health monitoring (41)
- Simulation (36)
- Monitoring (32)
- Steel (27)
- Korrosion (25)
- Laser beam welding (25)
- Ultrasound (25)
- Drop test (23)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (276)
- 7 Bauwerkssicherheit (255)
- 9 Komponentensicherheit (209)
- 3 Gefahrgutumschließungen; Energiespeicher (147)
- 9.3 Schweißtechnische Fertigungsverfahren (86)
- 4 Material und Umwelt (72)
- 7.2 Ingenieurbau (71)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (71)
- 5 Werkstofftechnik (63)
- 8.4 Akustische und elektromagnetische Verfahren (60)
Paper des Monats
- ja (1)
A new burner concept (PEROXY-BAM®) for the combustion of liquid organic peroxides (Peroxy-fuels) is presented. As peroxy-fuels are thermally unstable the design of burners for them should be accordingly modified ensuring a safe operation. It is found that 10 to 100 time less amounts of peroxy fuels are required for the same heat flux or output in comparison to hydrocarbons. Correspondingly, the fuel pump power and the volume of combustion chamber (furnace) are also reduced. As a result of less amount of fuel the emissions will also be stepped down and oxygen in the molecule helps to establish conditons like in an oxy-fuel combustion process. The advantages of using peroxy-fuels over hydrocarbons inside a model combustion chamber are also investigated with the help of CFD (Computational Fluid Dynamics) simulations.
The present investigations cover different relevant influences on the numerical calculation of welding-induced distortion. Therefore, a single-layer pulsed gas metal arc (GMA) weld of structural Steel S355J2+N with a thickness Öf5 mm is experimentally and numerically investigated. The influences of mesh density, tack-welds, and continuous cooling transformation (CCT) diagrams on welding-induced distortion are studied. The quality and quantity of These effects are clarified based on the used experimental and numerical set up. The occurring differences between the investigated cases achieve significant values. Consequently, prediction of welding-induced distortion can be improved considering the present investigations.
Dye-biomolecule conjugates and NIR-fluorescent particles for targeting of disease-related biomarkers
(2011)
Indispensable for fluorescence imaging are highly specific and sensitive molecular probes that absorb and emit in the near infrared (NIR) spectral region and respond to or target molecular species or processes. Here, we present approaches to targeted fluorescent probes for in vivo imaging in the intensity and lifetime domain exploiting NIR dyes. Screening schemes for the fast identification of suitable fluorophores are derived and design criteria for highly emissive optical probes. In addition, as a signal amplification strategy that enables also the use of hydrophobic NIR fluorophores as fluorescent reporters, first steps towards versatile strategies for the preparation of NIR-fluorescent polymeric particles are presented that can be utilized also for the design of targeted and analyte-responsive probes.
A novel quasi-distributed long-gauge fiber optic strain sensor system for dynamic measurement
(2011)
We present a novel technique based on incoherent optical frequency domain reflectometry (OFDR) to measure length changes quasi-distributed between reflection points in optical fibres. The technique enables length changes to be measured with a resolution better than 1 µm and allows for static and dynamic measurement capabilities up to 2 kHz. We demonstrate that dynamic measurements of multiple fibre sections can be conducted independently from each other with high precision. Due to the precise and dynamic measurement capabilities, the proposed sensor system is expected to open new fields of application, especially in the structural-health-monitoring sector. Possible applications are discussed in the paper.
The material parameters melt flow rate MFR, density D, notched impact strength N.I.S. at -30 °C, stress crack resistance FNCT and resistance to oxidative degradation Ox (determined by the increase of MFR) have been selected for a comparison of polyethylene grades for one design type in the “European Standard EN 15507 - Transport packaging for dangerous goods - Comparative material testing of polyethylene grades”. The parameters have a systematic relationship with design type tests. The notched impact strength at -30 °C and the resistance to oxidative degradation of polyethylene grades determined with test specimens of compression moulded sheets are directly comparable with drop tests at -18 °C of design types produced of these grades after pre-storage with 55 % nitric acid for 21 days at 40 °C. The impact of the pre-storage time of jerricans with 55 % nitric acid at 40 °C and 23 °C on the marginal drop heights in drop tests at -18 °C, on the MFR and on the tensile properties tensile strength, breaking elongation and the elastic modulus were investigated. Packaging design types (jerricans) made of three polyethylene grades from different producers were pre-stored with 55 % nitric acid for 21,42 and 84 days at 40 °C as well as for six months at 23 °C. The MFR and tensile properties of test specimens taken from the design type side walls as well as the marginal drop heights of the jerricans in drop tests at -18 °C were determined.
The values of the notched impact strength at -30 °C of polyethylene grades are not comparable with the marginal drop heights determined in drop tests at -18 °C. The oxidative damaging impact of nitric acid has a greater effect on the grade with lower resistance to oxidative degradation by reducing more significantly the marginal drop heights with increasing pre-storage time.
Pre-damage with 55 % nitric acid for 21 days at 40 °C, as recommended in ISO 16101 and EN 15507 caused an increase in the marginal drop heights of most design types in drop tests when compared with design types without pre-damage. The test results demonstrated clearly that pre-storage of the jerricans for six months at 23 °C caused a higher increase in the MFR and lower marginal drop heights of the jerricans in drop tests at -18 °C compared with pre-storage of the jerricans for 21 days at40 °C.
The mechanical properties change as a result of diffusion of nitric acid into the polyethylene grades and the reaction of the nitric acid with the polymers. The percentage decrease and increase in the tensile strength, breaking elongation and elasticity modulus of test specimens taken from the design type side walls after different pre-storage times were only partly comparable with the marginal drop heights in drop tests at -18 °C.
Plasma processes are used in many fields of Science and technology. While a plasma oxygen treatment produces a broad variety of different oxygen-containing functional groups, tailored - surface functionalisation demands preset functional groups in known concentration. Due to the fact that most of plasma experiments need expensive vacuum equipment increased efforts are to observe to apply atmospheric pressure plasma processes. Thus, Dielectric Barrier Discharge (DBD) and corona treatment of polymer foils have a long tradilion in industry to modify them for printing, laminating, adhesion promotion, etc. Thercibre, increasing interest is observed to make these atmospheric pressure processes more effeclive. Newly developed methods like plasma-printing were used for surfaces in biological and medical applications or for printed circuits.
In Operational Modal Analysis, the modal parameters (natural frequencies, damping ratios and mode shapes) obtained from Stochastic Subspace Identification (SSI) of a structure, are afflicted with statistical uncertainty. For evaluating the quality of the obtained results it is essential to know the respective confidence intervals of these figures. In this paper we present algorithms that automatically compute the confidence intervals of modal parameters obtained from covarianceand data-driven SSI of a structure based on vibration measurements. They are applied to the monitoring of the modal parameters of a prestressed concrete highway bridge during a progressive damage test that was accomplished within the European research project IRIS. Results of the covariance- and data-driven SSI are compared.
Standardized test methods by which the efficacies of conventional Chemical wood preservatives against insects determine their toxic effects against larvae of wood boring beetles or their feeding prevention by termites. Although alternative control strategies to the application of biocides exist, such as interference with insect behavior during mating or when searching for suitable breeding and feeding sites, their acceptance, too, depends on efficacy evaluation. This is why new test set ups are needed which take behavior modifying control strategies into account. This paper will demonstrate how new laboratory tests must be designed or how existing Standards can be altered to reliably interpret insect behavior including its successful manipulation in a standardized format.
To ensure a high operational reliability of offshore wind turbines (OWEC) with economically acceptable repair and maintenance efforts, comprehensive diagnosis and supervision concepts are required. Automatic monitoring Systems will be an essential part of such concepts. Because of the fact, that during Operation there will be static and dynamic interaction between the components ‘structure’, ‘machinery’ and ‘blades’ it is necessary to develop the monitoring techniques in an overall concept. These monitoring Systems are supposed to be applied for the design and testing as well as for the Operation and maintenance phases. The knowledge of the dynamic behavior of wind turbines is important both for the design and for a safe Operation. The available monitoring data from a period of three years, allow first conclusions on the long-term Operation of such Systems in terms of quality requirements to the instrumentation to the structure and the rotor blades
This paper describes a structural reliability analysis utilizing monitoring data in the ultimate limit state with consideration of the uncertainties of the monitoring procedure. For this purpose the uncertainties of the monitoring data are modeled utilizing a new framework for the determination of measurement uncertainties. The approach is based on a process equation and Statistical models of observations for the derivation of a posterior measurement uncertainty by Bayesian updating. This facilitates the quantification of a measurement uncertainty using all available data of the measurement process. For the reliability analysis in the ultimate limit state, monitoring data can be utilized as a loading model Information and as proof loading, i.e. resistance model Information. Both approaches are discussed with generic examples and it is shown that the modeling of monitoring data in a reliability analysis can result in a reduction of uncertainties and as a consequence in the reduction of the probability of failure. Furthermore, the proof loading concept is developed further to account for the uncertain characteristic of proof loading due to the measurement uncertainties which is consistent with the framework for the determination of measurement uncertainties. These approaches and findings can be utilized for the assessment of structures for life cycle extension and the design of monitoring Systems.
Residual stresses arising during welding, especially in high energy beam welding, can reach levels up to the material specific yield strength causing service life mitigating consequences through stress relaxation or stress corrosion cracking. A number of processes were developed like stress relief annealing or the low-stress-no-distortion-technique to reduce these stresses.
But such methods are only applicable for wider welds and simple component geometries or they are cost-intensive. The method presented in this paper uses the welding beam after welding in a defocused mode for heating the material regions in a certain distance from the weld on both sides. With this process it is possible to decrease the stresses in small welds with high stress gradients without any contact surfaces or additional equipment. Dependent on the component geometry and on the laser power it is possible to use different parameters for this process. The adjustable process parameters are the radius and the power of the defocused beam and the transversal and longitudinal distances between the welding and the defocused beam. In this work the mechanism and the influence of the process parameters are investigated by FEM-simulation and a number of experiments on the ferritic steel S355J2+N with 5 mm thickness. The best experimental result presented in this paper shows a stress reduction of about 73 %.
Fiber optic sensors are increasingly used because of their outstanding performance or if special requirements avoid the application of conventional electrical sensors. The scientific background for optical fiber sensors is well developed; however, the characteristic of sensors applied in rather harsh environment are almost always different from characteristics determined in laboratory or before its installation. In order to achieve long-term stable function and reliable measurement data after application and under harsh environmental conditions, guidelines for characterization and specification of sensor components are needed as well as methodologies for testing the sensor performance must be developed. Performance tests carried out revealed that there are still some restrictions with respect to long-term reliable use: first, some sensor products available on the market are not very often appropriately characterized, described and validated; second, application procedures are not always defined due to a lack of understanding the micromechanical issues in the interface zone between sensor and measuring object. Application procedures and profound knowledge of materials behaviour are necessary to get results from the sensor that can be reliably used. The paper describes first guidelines to prove the quality of fiber optic strain sensors, a testing facility developed for unbiased tests and certification of surface-applied sensors as well as result from comparison of commercially available strain sensors.
Fibre-optic sensors for early damage detection in plastic insulations of high-voltage facilities
(2011)
Fibre-optic sensors (FOS) have great potential as online damage detectors when integrated in HV accessories. Among their well-known use as temperature and strain sensors, there are some more opportunities of use, e. g. they can intimately be embedded in polymeric insulations of HV cable terminations and joints to detect and monitor partial discharges right at the location of their origin. Two FOS types for early PD detection were investigated: an embeddable fibre-optic acoustic sensor to measure acoustlc waves in polymeric insulations generated by PDs, and a fluorescent optical fibre to detect first optical effects during ionization processes in the insulation material. The paper descrlbes these methods, related monitoring Problems and shows first test results.
Wann ist es sinnvoll ein Biozid in ein synthetisches Material einzubringen? Wenn dadurch ein Problem gelöst wird. Deshalb sollte bei jeder Versuchsplanung die Frage stehen: Was ist das Problem, das man durch Biozieinsatz lösen will? Wie kann es im Laborversuch dargestellt werden? Konnte der Laborversuch zeigen, dass bei Biozideinsatz das Problem kleiner wird, beziehungsweise nicht mehr existiert? Je höher die Teststufe ist, umso mehr muss der Prüfablauf auf die Praxisbedingungen in der Gebrauchsphase des biozidhaltigen Erzeugnisses abgestimmt werden. Auf Stufe 1 werden in der Regel einzelne Wirkstoffe getestet. Ziel ist, die prinzipielle Wirksamkeit nachzuweisen, um die Ergebnisse für die Zulassung auf die Positivliste biozider Wirkstoffe der Biozidrichtlinie einzureichen. Während auf Stufe 1 bereits Normmethoden unter Einbeziehung einer relevanten Materialmatrix angewendet oder für die Fragestellung adaptiert werden können, ist dies für Stufe 2 oftmals nicht gegeben. Stufe 2 zeichnet sich durch Prüfmethodik mit praxisrelevanten Belastungen zur zeitraffenden Alterung des Biozids in seiner Materialmatrix aus. Hier stellt sich auch die Frage zur Langzeitwirksamkeit. Anstelle eines einzelnen Wirkstoffs wird oftmals ein Gemisch verschiedener Wirkstoffe und zusätzlichen Additiven, die wiederum Einfluss auf beispielsweise die Verteilbarkeit, Stabilität und Bioverfügbarkeit haben können. Es wird also kein Wirkstoff, sondern ein Biozidprodukt geprüft. In dem Biozidprodukt dürfen aber nur Wirkstoffe eingesetzt werden, die im Rahmen der Biozidrichtlinie bereits zugelassen sind und auf der Positivliste zu finden sind. Stufe 3 wird diskutiert im Zusammenhang mit Biozidprodukten mit Außeneffekt. Sie beschäftigt sich mit dem Nachweis von Vorteilen durch die Biozidnutzung. Hier gilt es den Verbraucher- und Umweltschutz gegen den Nutzen der möglichen Wertschöpfung oder auch den Gesundheitsschutz durch Biozideinsatz abzuwägen.
A dynamic and quasi-distributed sensor principle for simultaneous measurement of length changes and optical power changes between reflection points in an optical fiber is presented. The technique is based on the incoherent optical frequency domain reflectometry (I-OFDR). Length change resolutions < 1 µm and measurement repetition rates up to 2 kHz can be achieved using standard single-mode and multi-mode optical fibers. Simultaneous length change and refractive index measurement as well as field test results showing the deformation of a masonry building under seismic load are presented. Promising fields of application for this technique are the structural health monitoring sector and chemical process control.
The debonding of a fiber in a glass fiber / epoxy composite under transverse loading is studied. The stress field in the interface as well as the energy release rate are analysed for two fiber volume fractions.
The circumferential propagation of an Interface crack starting at the center of a fiber which is located within a hexagonal fiber array is studied. The analysis is performed by a finite element Simulation under plane stress conditions. Two fiber volume fractions are considered, this is 30% and 70%. The stress distribution before and during crack propagation is calculated for different stages of the
crack. The crack opens by dominating tensile stresses in the first phase while it closes when propagating along the interface. The total energy release rate as well as the mode I and mode II parts are calculated. In the first phase the crack is driven by an increasing mode I energy release rate, indicating an unstable crack propagation. Then the mode II energy release rate increases rapidly and dominates the debonding process while the mode I part decreases and finally vanishes. Subsequently also the mode II part decreases, indicating stable crack propagation. In the last phase the crack becomes unstable again due to a strongly increasing mode I energy release rate. During the debonding process a remarkable change the mode ratio takes place.
The main features of the debonding process are similar for low and high fiber volume fraction. In case of the high fiber content, however, the mode I part is more pronounced and the maximum of the total energy release rate is shifted to lower crack angles.
The geological storage of carbon dioxide (Carbon Capture and Storage, CCS) in depleted gas reservoirs or in saline aquifers is a widely discussed issue. Carbon dioxide may induce corrosion on the piping steels during compression, transportation and injection. Therefore,
selection of appropriate piping steels is a key factor in order to increase the safety and reliability of the CCS technology, and to keep the processes cost-effective.
The here described subproject of the COORAL project (German acronym for “C02 purity for capture and storage”) deals with the levels of impurities in the C02 stream that will be acceptable when using specific steels. Material exposure to carbon dioxide (C02) containing
specific amounts of water vapor, oxygen (02) sulfur dioxide (S02), nitrogen dioxide (N02), carbon monoxide (CO) can be a challenge to steels. Within this subproject 13 different Steels are tested for suitability as materials used for compression, transportation and injection Units within the CCS chain.
BAM (Federal Institute for Material Research and Testing) is the competent authority for mechanical and thermal safety assessment of transport packages for spent fuel and high level waste (HLW) in Germany. In context with package design approval of the new German HLW cask CASTOR HAW28M, BAM performed several drop tests with a half-scale model of the CASTOR HAW/TB2. The test model was manufactured by GNS (Gesellschaft fur Nuklear Service mbH) and tested under accident transport conditions on the 200 tons BAM drop test facility at the BAM Test Site Technical Safety. For this comprehensive test program the test specimen CASTOR HAW/TB2 was instrumented at 21 measurement planes with altogether 23 piezo-resistive accelerometers, five temperature sensors and 131 tri-axial strain gauges in the container interior and exterior, respectively. The strains of four representative lid bolts were recorded by four uniaxial strain gauges per each bolt. Helium leakage rate measurements were performed before and after each test in the above noted testing sequence. The paper presents some experimental results of the half-scale CASTOR HAW/TB2 prototype (14,500 kg) and measurement data logging.
BAM Federal Institute for Materials Research and Testing is the competent authority for mechanical safety assessment of transport packages for radioactive material in Germany. The further development of state-of-the-art technology concerning assessment methods is essential for a qualified work of involved designers and authority experts. The paper gives an example of current development done to improve understanding and modeling capabilities of wood filled impact limiter. In order to reduce the loads applied to the package containment, which result from regulatory drop tests, most packages are protected by energy dissipating impact limiter. Wood, encapsulated by steel sheets, is one of the materials typically used for energy dissipation in these impact limiter. Very often, mechanical safety cases regarding the 9 m drop test are performed computationally, where it is essential to use reliable and verified computational methods and models. In this context, the paper presents an approach for a finite element material model for wood. Thereby, the mechanical behavior of wood under compression loading is the focus of the development work. Additionally, material orientation as well as strain rate, temperature and lateral constraint may vary. A large number of experiments, particularly compression tests, was designed and performed to establish an adequate experimental database for modeling verification. The experimental results enabled the derivation of necessary requirements: The material model has to take into account strain rate and temperature dependencies as well as the anisotropic characteristics of the material, a proper yield criterion, flow rule and hardening law. Such a material model is currently not available in established commercial dynamic finite element codes. Thus it is necessary to create a user-defined material model considering the mentioned requirements. A first step was done by determining a yield surface as well as detecting flow and hardening mechanisms from experimental force-deflection curves. In a next step the LS-DYNA material model MAT_75 was altered according to conclusions of former BAM development work, regarding the modeling of post-peak softening as a function of lateral constraint. Future research will contain the further development, implementation and verification of a material model for wood.