Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures
(2023)
Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring, and inspection techniques within the project SealWasteSafe. A specifically developed alkali-activated material is compared to classical salt concrete. A comprehensive multi-sensory monitoring scheme is used at 150-340 l specimens to monitor setting and hardening of both materials. All sensors are demonstrated to resist the highly alkaline environments. Besides cabled and wireless temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than eight months. After hardening of the specimens, further nondestructive evaluations using ultrasonic echo and thermographic measurements are conducted.
Preliminary results proof the suitability of the tested sensors and clearly highlight differences between the tested materials. Particularly, the newly developed alkali-activated material shows lower acoustic emission activity indicating less cracking activity. Additionally, unique ultrasonic methods will enable better images of potential internal objects and cracks at in-situ sealing structures. A largescale ultrasonic system is optimised to reliably detect objects at a depth exceeding 9 m while still obtaining a good resolution. Modelling studies show the potential of further increasing the distance between individual transducer arrays. Additionally, a new ultrasonic borehole probe using phased arrays allowing for beam focussing is constructed and tested. Laboratory measurements at a halfcylindrical concrete specimen coincide well with the previous modelling. In total, the presented safe materials, detailed monitoring approaches and ultrasonic quality assurance methods will help to obtain safe sealing structures within salt as a host rock. The concepts can partly be transferred to sealing structures in alternative host rocks and will also be valuable for non-nuclear waste repositories.
Im Dezember 2019 wurden bei einer turnusmäßigen Inspektion der B 1-Brücke am Altstädter Bahnhof in Brandenburg an der Havel massive und schnell voranschreitende Schäden festgestellt. Als Ursache für die Risse entlang der Längsträger wurde das Versagen eines signifikanten Anteils der Spanndrähte der konzentrierten Spannglieder vermutet. Die Brücke wurde umgehend für den Verkehr gesperrt und im Mai 2021 gesprengt. Im Vorfeld der Sprengung wurden durch das Bundesministerium für Digitales und Verkehr (BMDV) weiterführende Untersuchungen zum Schadensbild veranlasst, welche vom Landesbetrieb Straßenwesen Brandenburg koordiniert und in den Bauablauf integriert wurden. Das von der Hochschule für Technik und Wirtschaft (HTW) Dresden erstellte Versuchskonzept ist Bestandteil des vorangestellten ersten Teils des Beitrags [1]. Hier im zweiten Teil werden ausgewählte Ergebnisse der umfangreichen versuchsbegleitenden Mess- und Monitoringmaßnahmen beschrieben, welche in Kooperation der HTW Dresden, der Bilfinger Noell GmbH sowie der Bundesanstalt für Materialforschung und -prüfung (BAM) durchgeführt wurden.
The project "SealWasteSafe" of the Bundesanstalt für Materialforschung und -prüfung (BAM, Berlin) deals with sealing structures applied for underground disposal of nuclear waste from two perspectives: (1) material improvement for application in sealing constructions and (2) feasibility study regarding multi-sensor approaches to ensure quality assurance and long-term monitoring.
One specimen of 150 l made of alkali-activated material, which was found innovative and suitable for sealing constructions based on preliminary laboratory studies, and, for comparison purpose, another one made of salt concrete, are manufactured with an integrated multi-sensory setup for quality assurance and long-term-monitoring. The specimens were left in their cast form and additionally thermally insulated to simulate the situation in the repository. The multi-sensory concept comprises RFID technology embedded in the specimens suppling material temperature and moisture measurements, integrated fibre optic sensing allowing strain measurement and acoustic emission testing for monitoring possible crack formation. Overall, the suitability and the functionality of the sensors embedded into and attached to strongly alkaline (pH > 13 for the AAM) and salt corrosive (NaCl) environment was proven for the first 672 h.
First temperature measurement based on RFID succeeded after 626 h for the alkali-activated material and after 192 h for the conventional salt concrete. Strain measurement based on distributed fibre optic sensing turned out the alkali-activated material with > 1 mm m-1 undergoing approximately twice the compression strain as the salt concrete with strains < 0.5 mm m-1. In contrast, the acoustic emission first and single hits representing crack formation in numbers, was found for alkali-activated material half of that detected at the salt concrete.
Grouted connections are intensively used in offshore rigs, platforms as well as jacket and monopile offshore wind turbine structures. Being located in remote offshore conditions, these connections can experience considerable adverse loading during their lifetimes. Degradation was reported inside similar connections, which were installed in the last three decades. Grouting in the offshore sites may often be proven difficult, which eventually leads to reduced load-bearing capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs. In this study, scaled grouted connections were manufactured using a novel mould, whose integrity were monitored using digital image correlation (DIC). The connections were loaded under static load to visualize the main failure pattern using distributed fibre optic sensors and acoustic emission (AE) analysis. Grouted connections were then repaired using a cementitious injectable grout. The effectiveness of the grout injection was monitored using dye penetration technique. Finally, specimens are reloaded to identify the potential of such repair for grouted connections.
Verwendung faseroptischer Messtechnik im Zuge wiederholter Eignungsprüfungen an Verpressankern
(2020)
Im Rahmen des Ausbaus des Dortmund-Ems-Kanals wurden an der Schleuse Gleesen Forschungsanker installiert, die Rückschlüsse auf das Tragverhalten in Folge des chemischen Angriffs kalklösender Kohlensäure geben sollen. Die Forschungsanker werden seit der Erstellung im Jahr 2017 mit verteilter faseroptischer Sensorik während der jährlichen Eignungsprüfungen untersucht. Die Ergebnisse der Jahre 2017 bis 2019 werden im Folgenden dargestellt.
Der Vortrag gibt einen Überblick über die Einsatzmöglichkeiten faseroptischer Sensorik (FOS) als ZfP-Verfahren. Dabei werden an Beispielen lokale und verteilte faseroptische Verfahren zur Dehnungs-, Temperatur- und Risserfassung sowie zur akustischen Messung vorgestellt. Weiterhin werden Möglichkeiten zur Selbstdiagnose von FOS aufgezeigt.
In Glasfasern eingeschriebene Bragg-Gitter (FBG: fibre-based Bragg gratings) sind über die Verschiebung der Bragg-Wellenlänge in der Lage, Stauchungen und Dehnungen von Glasfasern hochgenau zu erfassen. In Kompositwerkstoffe eingebettete faseroptische Sensoren können Bauteile bezüglich ihrer mechanischen Integrität überwachen und früh-zeitig Informationen über Materialveränderungen gewinnen.
Um die Zuverlässigkeit eines solchen Sensors zu gewährleisten, ist es wichtig, die korrekte Funktion des Sensors im Verbund mit der Werkstoff-Matrix on-line und in-situ sicherzu-stellen. Im Rahmen des DFG-Projekts FAMOS² (FAser-basierter Magneto-Optischer SchichtSensor) wurde ein selbstdiagnosefähiger Schichtsensor entwickelt, der mit Hilfe von magnetostriktiven Aktorschichten aus Nickel bzw. Eisen-Nickel validiert werden kann.
Der FAMOS²-Schichtsensor wird durch ein PVD (physical vapour deposition)/ECD (electro-chemical deposition) Hybridschichtsystem realisiert, das auf dem Fasermantel im Bereich des FBG haftfest, homogen und langzeitfunktional abzuscheiden ist. Dabei wird in einem ersten Schritt ein etwa 100 Nanometer dünnes PVD-Schichtsystem aus Chrom und Kupfer als Haftvermittler auf der Glasfaser bzw. als leitfähige Startschicht für den nachfolgenden ECD-Prozess abgeschieden. Um eine rotationssymmetrische Schich-tabscheidung zu gewährleisten, erfolgt während der PVD-Beschichtung eine Rotation der Glasfasern. In einem zweiten Schritt wird dann unter Verwendung eines klassischen Watts-Elektrolyten in einer speziell entwickelten ebenfalls rotationssymmetrisch aufgebau-ten ECD-Durchströmungszelle dann die etwa 30 Mikrometer dicke, magnetostriktive Ak-torschicht auf dem PVD-Schichtsystem abgeschieden, im Vergleich sowohl reine Nickel-Schichten als auch Nickel-Eisen-Schichten.
Ein äußeres Magnetfeld dehnt die magnetostriktive Aktorschicht und damit auch die Faser reversibel. Diese Dehnung führt zu einer Verschiebung der Bragg-Wellenlänge, welche direkt mit der Stärke eines zu messenden oder zu Validierungszwecken vorgegebenen Magnetfeldes korreliert. Die Anpassung der Beschichtungsverfahren an die Fasergeome-trie und die mechanischen Eigenschaften der Hybridschichten werden hinsichtlich der me-chanischen Integrität des faseroptischen Sensors diskutiert und der Nachweis der Selbst-diagnosefähigkeit erbracht.
Die durchleuchtete Brücke
(2018)
An auto-validation tool for the reliability quantification of materials integrated fiber Bragg grating (FBG) strain sensors have been developed and tested. The FBG strain sensor was jacketed with a magnetostrictive layer based on iron-nickel which, when excited by a specific magnetic field, adds an artificial strain to the sensor. The fixed relationship between magnetic induction and wavelength shift of the FBG strain sensor characterizes the bond strength and adhesion between the sensor and the surrounding structure. Due to an easily applicable magnetic field, it is possible to validate the sensor performance in a non-contact, fast way without disturbing the data-acquisition process.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Sensors integrated into devices and structures provide essential data to control, optimize or manage machines and structural components. In the last years, processes, applications and machine parts became more and more intelligent. Consequently, the need for sensor validation increased significantly in order to rely on sensor data and measurement results.
Structure-integrated fibre optic strain sensors, such as fiber Bragg gratings (FBG), are of special interest in the composite manufacturing industry. This type of sensor makes it possible to gain information and to collect measurement data about entire production processes and whole life-time cycles of composite-made machine parts and structures. However, validation concepts and approaches for this type of sensors are barely reported in literature. Furthermore, all the reported activities have the drawback that the sensor diagnosis strategy is implemented as limited mathematical models and/or complex time-consuming spectral analysis tools which are applied in data post-processing loops. However, to automate sensor validation and to apply real-time and in-field sensor fault detection, it is necessary to acquire measurement data and information about the measurement reliability at the same time.
A new concept for the self-diagnosis of embedded fiber Bragg grating (FBG) strain sensors was developed, simulated and experimentally tested. This concept is based on a magnetostrictive metallic layer directly coated on the fibre cladding over the grating segment of the FBG sensor, so that an on-demand external magnetic field in a millitesla scale can produce a controllable artificial strain as an indication signal for the remote optical interrogator. The relationship between the pre-defined magnetic field and its induced Bragg wavelength shift characterizes this validation concept. Any deviation of the local bonding state of the interfaces from the initial or/and any change of shear strain transferring mechanism from composite matrix to the optical fibre core will result in alterations in this sensitive relationship, and thus triggers an immediate alert for a further inspection. The finite element method is used to simulate the strain of this configuration as result of different values of the magnetic field in order to optimize the geometrical sensor parameters. The simulations are verified by experiments results. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Innovative structural damage detection of bridges by least squares adjustment with constraints
(2016)
Long-term monitoring of bridges requires the early detection of spreading damage because very often the damage is not really visible. For many decades engineers and scientists relayed on dynamic methods especially modal ones. However, after fundamental tests by the U.S. FHWA in 1993, it became evident that more successful methods should be developed, but no innovation really happened. A substantial innovative detection method started four years ago from Lagrange Multiplier Testing which eventually resulted in experimental verification based on measurement of deflection and curvature of the bridge beam and together the methodological combination of both.
Durch faseroptische Sensoren können Bauteile im Einsatz kontinuierlich überwacht und frühzeitig Informationen über Materialveränderungen gewonnen werden. Mittels einer magnetostriktiven Aktorschicht, welche den Sensor umhüllt, kann nun auch die korrekte Sensorfunktion jederzeit kontrolliert werden. Als Aktorschicht eignet sich galvanisch abgeschiedenes reines Nickel oder Nickel-Eisen in der Zusammensetzung 50:50. Um diese haftfest mit dem Sensor zu verbinden wurde ein ECD/PVD-Kombinationsschichtsystem entwickelt. Die mechanischen Eigenschaften der ECD-Schicht können sowohl mit einer auf die Fasergeometrie angepassten instrumentierten Eindringprüfung als auch einem 2-Punkt-Biegeversuch bestimmt werden.
Mit einem auf Lagrange-Multipiikator-Tests basierenden Monitoring von Brücken ist es gelungen, in Belastungsversuchen an einer Holzbrücke (7,25 m Spannweite), an der relativ kleine Schädigungen künstlich herbeigeführt worden waren, die Zuverlässigkeit dieser Art des Monitorings zu bestätigen. Ausgangspunkte waren Messung von Durchbiegungen sowie Krümmungen und die Zusammenführung der jeweiligen Regression mit Nebenbedingungen, die den mechanischen Bedingungen gehorchen, unter Einschluss von Lagrange-Multiplikatoren, die sich als brauchbare Testparameter erwiesen.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Detecting spreading damage in bridges is a demanding task for engineers today when the ageing infrastracture of industriaiized countries is degradating more and more. To successfully deal with tbis problem, a really advanced method has been elaborated basing on Langrange Multiplier (LM) tests and following the principle of simplicity by Hilbert and extending comments by Helmholtz refering to a combination of measurement and analytical treatment. Finally, an easy mathematical fonnation has been created.
The absolute detection of a gap distance of loose and ftxed extrinsic Fabry-Perot interferometer (EFPI) sensors with conventional measurement Systems is not possible. Due to this EFPI-sensors were deemed to be unfit for distance determination in comparision with FBG sensors. With the conventional measurement method a continous measurement of the EFPIsensors was necessary. Otherwise data about the distance change was lost. Additional it is necessary to detect the tumaround points in the interference signal with 100%. This made it worse for the analysis and the use of the sensor. At BAM Federal Institute for Materials Research and Testing a measurement System called “EFPI-Scan” is developed which can measure the absolute gap distance of four connected EFPI-sensors synchronous. Every measurement channel is temperature independetn and long term stable. Test measurements showed a deviation of maximum ±1 gm per hour. Furthermore it is possible to measure with different measurement modes (abolute, relative and a combination of both). Special emphasis should be placed to the absolute measurement accuracy of ± 5 pm at a gap distance determination ftom 40 up to 4000 pm.
In diesem Paper wird ein absolut messendes faseroptisches Messsystem zur Bestimmung des Gap-Abstandes von niedrig reflektierenden losen und festen extrinsischer Fabry-Pérot Interferometer (EFPI) vorgestellt. Die häufigste Methode zur Bestimmung von Dehnungen oder Bewegungen durch EFPI-Sensoren ist eine kontinuierliche relative Ermittlung einer Veränderung mit einer nachträglichen Auswertung. Unterbrechungen in der Datenerfassung oder Fehler bei der Interferenzstreifen-Auswertung führen zu einer nicht abschätzbaren Messunsicherheit. Damit war es bis dato nicht möglich, eine absolute Veränderung von eingesetzten EFPI-Sensoren zu bestimmen. Mit dem an der BAM entwickelten Verfahren, ist dies jetzt möglich, die absolute Veränderung zu bestimmen. Dieses System namens 'EFPI-Scan' wird in dem Papier dargestellt werden.
Movements in geological areas are mostly concentrated on faults or slipping zones. Detection of movements reaching critical values is of crucial importance to avoid losses and harms. The paper presents a new technology of detecting deformations and movements in soil or rock massifs. The core part of the sensing system is a tiny rod with embedded optical sensor fibres. This deformation measurement system was developed and the sensing rod can be installed in a borehole and enables the detection of beginning soil movements. The amount of deformation in soil or rock formations can then be estimated. The sensing rod has an outer diameter of 3 mm to 6 mm and contains several optical fibres. One fibre is used as online measurement system and provides integral strain information along the whole length of the rod. In case of a safety-relevant deformation (warning signal), the second sensing system based on fibre Bragg grating sensors positioned close to the expected shear zone will be activated and records then resulting deformations in detail.
Geotechnische Tätigkeitsfelder und Forschungsaufgaben haben sich immer an den modernen Herausforderungen orientiert und umfassen z. B. die Beschreibung und Quantifizierung der Interaktion zwischen Baugrund und Bauwerk, die Untersuchung des Untergrunds besonders hinsichtlich der technischen und sozialen Infrastrukturen und die Beeinflussung der Umwelt. Fragen der zivilen Sicherheit stellen steigende Anforderungen an die Tragfähigkeit und Dauerhaftigkeit von Bauwerken. Zur Lösung dieser Aufgaben entstehen vielfältige interessante Methoden und Verfahren zur Strukturbewertung, die neben der Erfassung des allgemeinen Zustands auch neue Erkenntnisse zum Bauwerksverhalten im Hinblick auf moderne Bautechnologien und auf die Lebensdauer von Bauwerken liefern. Die systematische, zuverlässige und langzeitstabile Erfassung von geotechnischen Messgrößen und Parametern bei der Strukturbewertung sowie die Beobachtung und Bewertung der geologischen Gegebenheiten mit technischen Hilfsmitteln ist dafür unerlässlich und lässt sich mit den Begriffen Zustandsanalyse und Bauwerksmonitoring zusammenfassen. Das Ziel dabei ist, mögliche Schädigungsmechanismen frühzeitig zu erkennen, um rechtzeitig Gegenmaßnahmen ergreifen zu können.
Fibre-optic sensors need to be more established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations. However, there are some open questions leading now and then to restraints in the user's community. The paper dicusses examples where fibre-optic sensors provide outstanding knowledge about the structure's behaviour, but application is often challenging. Requirements are listed and open questions to be solved are discussed. Short outlook to standards useful for better design, characterization and application is given. Standards are the basis for establiching SHM systems, especially for safety-critical structural diagnostics.
Fibre optic sensors for monitoring in safety-relevant structures have to be validated in order to proof their reliability under typical structural load conditions. The reliable use of optical fibre sensors depends strongly on an appropriate and qualitative application. Diagnostics of the physical condition of embedded and surface-applied fibre optic strain sensors are demonstrated on field examples. Distributed strain measurement based on Rayleigh backscattering is used to determine breakage of the fibre, interface adhesion problems and to identify application related strain transfer mechanisms.
In structural engineering timber is appreciated due to its low weight, its high aesthetic quality and because it is a renewable resource. The market share of timber structures and wood based hybrid structures will clearly increase over the next few years due to greater environmental awareness and a higher demand for sustainability. However, building with timber is marked by characteristics which lead to significant disadvantages in comparison wifh technical materials. For example, in outdoor areas Chemical and structural approaches offen lead to unsatisfactory and expensive Solutions with respect to durability. An idea is to make natural lumber a high-performance material which can be designed to meet the engineers’ demands conceming strength, stiffness, durability, shape, safety etc. These changes can affect the material itself, new technologies or a new approach to monitoring. Especially hybrids made of common timber products and technical textiles or enhanced timber products are high-capacitive and reach high bearing strengths with low material input and good durability. These hybrids are particularly qualified to use the advantages of wood and minimize the disadvantages. They can be used in different ways for load bearing structures, i.e. bridges. New construction types need monitoring to observe the stress and strains for which they were designed, and the structures’ behaviour as well as to guarantee required safety levels. The aim of successful usage of fibre optic measurement technology in timber elements was the development of a technology for measuring the lengthening in timber elements and wood based hybrid elements by using fibre optic sensors. The scientific and technical challenge was to develop an applicationtechnology for optical glass fibres in timber and densified veneer wood.
In laboratory tests as well as with the erection of a footbridge and during in-situ tests it could be shown that the structurally integrated fibre optic sensor technology used is suitable for short and long term measurement. The developed embedment technology tums out to be practical and fit for good transfer of strain-values from timber to the modified sensor fibres.
Static and dynamic pile tests are carried out to determine the load bearing capacity and the quality of reinforced concrete piles. As part of a round robin test to evaluate dynamic load tests, structure integrated fibre optic strain sensors were used to receive more detailed information about the strains along the pile length compared to conventional measurements at the pile head. This paper shows the instrumentation of the pile with extrinsic Fabry-Perot interferometers sensors and fibre Bragg gratings sensors together with the results of the conducted static load test as well as the dynamic load Tests and pile integrity tests.
Reinforced concrete piles are used in case of structures that are constructed on soft ground to transfer the loads into deeper strata with sufficient bearing capacity. In order to determine the pile’s behavior and possible damage, static and dynamic pile tests are carried out. Dynamic measurements taken from the pile head can show the bearing behavior and structural integrity by using the theory of wave propagation. In order to receive more precise information about the pile features, now, a string of sensors is embedded at different levels of the pile. A fiber optic strain wave sensor, based on the extrinsic Fabry-Perot interferometer (EFPI), has already been developed and tested in full-scale field tests by Schallert (2010). It was possible to detect the introduced deformation caused by the static load and the dilatational wave during dynamic loading. Although the full-scale tests were successful, the engineering design of the sensor body left room - from the economical point of view - to be optimized. After laboratory tests with the optimized sensor, a cast-in-situ bored pile has been built at the BAM Test Site Technical Safety in Horstwalde, South of Berlin. Additionally to the EFPI sensors, fiber Bragg grating (FBG) sensors, temperature sensors and resistance strain gauge (RSG) sensors are embedded in order to compare the signals with each other. In this paper, the modified sensor and the Setup of the cast-in-situ bored pile along with results of dynamic tests are shown.