Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Dokumenttyp
Sprache
- Englisch (3)
Referierte Publikation
- ja (3)
Schlagworte
- Aerosol analysis (1)
- LIBS (1)
- Laser-induced breakdown spectroscopy (1)
- Matrix effects (1)
Quantitative laser-induced breakdown spectroscopy (LIBS) analysis operates on the assumption that the sample is completely dissociated and diffused within the highly energetic plasma on time-scales of analyte analysis, resulting in analyte emission ideally at the bulk plasma temperature and a signal that is linear with analyte mass concentration. However, recent studies focusing on aerosol analysis have found the heat and mass diffusion rates within laser-induced plasmas to be finite, resulting in particle-rich, locally perturbed areas within the hot bulk plasma. The goal of this study is to observe any related plasma differences, by calculating the bulk and local (i.e. analyte rich regions) plasma temperatures and electron density, to better understand the time frame of equilibrium between the local and bulk plasma properties. This study also seeks to determine whether the presence of large quantities of a matrix element can significantly alter the local plasma conditions, thereby generating matrix effects. We report the temporal profiles of particle-derived species, adding additional insight into the effect of local perturbation of plasma properties, with the conclusion that significant plasma residence (tens of microseconds) is necessary to minimize such effects.
An inductively coupled plasma (ICP) is analyzed by means of experiments and numerical simulation. Important plasma properties are analyzed, namely, the effective temperature inside the central channel and the mean flow velocity inside the plasma. Furthermore, the effect of torches with different injector diameters is studied by the model. The temperature inside the central channel is determined from the end-on collected line-to-background ratio in dependence of the injector gas flow rates. Within the limits of 3% deviation, the results of the simulation and the experiments are in good agreement in the range of flow rates relevant for the analysis of relatively large droplets, i.e., ~ 50 µm. The deviation increases for higher gas flow rates but stays below 6% for all flow rates studied. The velocity of the gas inside the coil region was determined by side-on analyte emission measurements with single monodisperse droplet introduction and by the analysis of the injector gas path lines in the simulation. In the downstream region significantly higher velocities were found than in the upstream region in both the simulation and the experiment. The quantitative values show good agreement in the downstream region. In the upstream region, deviations were found in the absolute values which can be attributed to the flow conditions in that region and because the methods used for velocity determination are not fully consistent. Eddy structures are found in the simulated flow lines. These affect strongly the way taken by the path lines of the injector gas and they can explain the very long analytical signals found in the experiments at low flow rates. Simulations were performed for different injector diameters in order to find conditions where good analyte transport and optimum signals can be expected. The results clearly show the existence of a transition flow rate which marks the lower limit for effective analyte transport conditions through the plasma. A rule-of-thumb equation was extracted from the results from which the transition flow rate can be estimated for different injector diameters and different injector gas compositions.
Recently, first analyses of single sub-micrometre particles, embedded in liquid droplets, by inductively coupled plasma optical emission spectrometry (ICP-OES) with a size-equivalent detection limit of several hundred nanometres were reported.1,2 To achieve lower detection limits which might allow for the analysis of particles in the nanometre size range a more sensitive technique such as mass spectrometry (MS) is required. Various modifications of particle delivery and data acquisition systems commonly used were carried out to install a setup adequate for ICP-MS detection. These modifications enabled us to supply droplets generated by a commercial microdroplet generator (droplet size: 3040 µm) with nearly 100% efficiency and high uniformity to the ICP. Analyses were performed using both standard solutions of dissolved metals at concentrations of 1 (Ag), 2 (Au), 5 (Au), or 10 (Cu) mg L-1 and highly diluted suspensions of gold and silver nanoparticles with sizes below 110 nm. In doing so, detection efficiencies of 10-6 counts per atom could be achieved while size-related limits of quantification were found to be 21 nm and 33 nm for gold and silver, respectively. Furthermore, the advantages of utilizing microdroplet generators vs. conventional nebulizers for nanoparticle analyses by ICP-MS are discussed.