Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (75)
- Vortrag (29)
- Posterpräsentation (4)
- Beitrag zu einem Tagungsband (3)
- Sonstiges (1)
Schlagworte
- Immunoassay (31)
- ELISA (24)
- Biosensoren (14)
- Antikörper (9)
- Biosensor (9)
- Abwasser (8)
- Carbamazepine (8)
- Biomarkers (7)
- Wastewater (7)
- Antibody (6)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (58)
- 1.8 Umweltanalytik (58)
- 1.9 Chemische und optische Sensorik (5)
- 6 Materialchemie (4)
- P Präsident (4)
- P.0 Präsident und andere (4)
- 6.1 Oberflächen- und Dünnschichtanalyse (3)
- 1.5 Proteinanalytik (2)
- 1.1 Anorganische Spurenanalytik (1)
- 6.3 Strukturanalytik (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (29)
Alternative Tools (AT) such as on-site test kits, on-site portable devices and continuous measuring devices, are useful to improve water quality assessment under EU directives, and water treatment processes, thus contributing to improving water management, as well as get insights on the dynamic of pollutants within water bodies. Although these tools have clear advantages (e.g. fast response allowing for real-time monitoring, ease-of-use, lower cost), they are perceived as less reliable than conventional analytical methods. Their alternative nature, innovative status, and non-standard operation mode require specific validation strategies that differ significantly from those of conventional analytical methods. Nevertheless, the validation of ATs, especially on-site test kits, portable devices and continuous measuring devices for water quality monitoring is crucial to support their acceptance, promote their use and make their application sustainable. In this paper, a validation procedure in 4 steps is proposed: (1) Comprehensive description of the AT; (2) Assessment of intrinsic metrological performance and operational factors within a single laboratory; (3) Assessment of inter-laboratory performances through an inter-laboratory comparison and, (4) Demonstration of the equivalence of results between the AT and a reference method. This paper discusses each step of the validation procedure, and examples to illustrate critical issues are provided.
Analytische Methoden für die Quantifizierung von Mikroschadstoffen (Synonym für Spurenstoffe) und Pathogenen im Wasser sind eine Grundvoraussetzung für die Umsetzung des Ziels Nr. 6 für Nachhaltige Entwicklung der UN, weltweit sauberes Wasser zur Verfügung zu stellen. Dafür sind schnelle, einfach zu bedienende und kostengünstige Überwachungssysteme notwendig. Antikörperbasierte Biosensoren haben das Potential, z.B. die Eliminationsleistung bezüglich kleiner organischer Moleküle durch die vierte Reinigungsstufe von Kläranlagen vor Ort zu überwachen. Darüber hinaus kommt modernen bioanalytischen Verfahren bei der Quantifizierung von Pathogenen eine immer wichtigere Rolle zu. Neben einer Bestandsaufnahme zu diesen Themen ist es das Ziel dieses Beitrags, die Anwendungsbarrieren von Biosensoren für die Wasseranalytik von Mikroschadstoffen abbauen zu helfen und die Vorzüge moderner bioanalytischer Methoden für die Quantifizierung von Pathogenen aufzuzeigen.
Der Vortrag beschreibt den Stand der Arbeiten an der BAM, Fachbereich Umweltanalytik zur Entwicklung von Sensoren für die Wasseranalytik. Er stellt die bisherigen Arbeiten da, die ausgehend von ELISAs, zunehmend portable Plattformen wie FPIA und LFIA umfassen. Beas-based Formate werden von mikrotiterplatten-basierten Techniken auf mikrofluidische Lab-on-Chip-Systeme übertragen, die bei geeigneter Miniaturisierung und Automatisierung als Sensorsysteme angesehen werden können. Der Vortrag endet mit einem Blick auf ein laufendes Monitoring-Projekt von anthropogenen Markern in Abwasser und charakterisiert die Treiber, die die Entwicklung von Sensoren für die Wasseranalytik in den letzten Jahren vorantreiben.
Im Vorhaben „MARKERIA - Bestimmung von anthropogenen Markerkonzentrationen für die SARS-CoV-2 Quantifizierung mittels eines Hochdurchsatzverfahrens (ELISA)“ geht es um die Bestimmung von Carbamazepin, Diclofenac, Koffein und einer endogenen Gallensäure als potentielle Marker für die Kalibrierung der SARS-CoV-2 Quantifizierung im Abwasser. Der Vortrag wurde gehalten im Rahmen der 22. Sitzung des Begleitkreises des übergeordneten Projektes ESI-CorA. Er gab den Projektstand wieder, den die BAM bis dahin erzielt hatte. Die Marker waren in sämtlichen untersuchten Abwasser-Zulaufproben enthalten und zeigten spezifische Trends. Weitere Korrelationen müsse die weitergehende Datenauswertung ergeben.A
Immunoassays, based on analyte recognition and capture by highly selective antibodies with high affinity, are intensively used in all fields of laboratory diagnostics and in screen-ings of food and environmental samples. Yet, for many purposes, online sensors are desir-able, and, in principle, all immunoassay tech-niques can be integrated into lab-on-chip set-ups that can work as continuous monitoring devices. Yet, the challenge remains to devel-op platforms and elements that are fit for a quick transition of laboratory microplate as-says to immunosensors.
The poster describes how molecular biology, especially recombinant expression of proteins, in this case, an enzyme, can underpin developments of biosensors. The fumonisin oxidase produced by the fungus Aspergillus niger (AnFAO) is highly selective for the toxic mycotoxin fumonisin. Its structure and sequence has been published before. We took this information and expressed the enzyme in E. coli. The enzyme proved active and could be employed in an amperometric biosensor for the detection of the mycotoxin.
The environmental fate of the frequently used broad-spectrum β-lactam antibiotic amoxicillin (AMX) is of high concern regarding the potential evolution of antimicrobial resistance (AMR). Moreover, it is known that AMX is prone to hydrolysis, yielding a variety of hydrolysis products (HPs) with yet unknown effects. Studies to identify those HPs and investigate their formation mechanisms have been reported but a long-term study on their stability in real water samples was missing. In this regard, we investigated the hydrolysis of AMX at two concentration levels in four distinct water types under three different storage conditions over two months. Concentrations of AMX and four relevant HPs were monitored by an LC-MS/MS method revealing pronounced differences in the hydrolysis rate of AMX in tap water and mineral water on the one hand (fast) and surface water on the other(slow). In this context, the occurrence, relative intensities, and stability of certain HPs are more dependent on the water type than on the storage condition. As clarified by ICP-MS, the main difference between the water types was the content of the metals copper and zinc which are supposed to catalyze AMX hydrolysis demonstrating an effective method to degrade AMX at ambient conditions.
Functionalized Ti3C2Tx nanosheets based biosensor for point-of-care detection of SARS-CoV‑2 antigen
(2023)
MXenes are considered a promising class of two-dimensional materials with extraordinary physical and electrochemical properties. Distinguished features like high specific surface area and outstanding electrical conductivity make them suitable for electrochemical biosensing applications. Here, we report the development of a biosensor involving the functionalized MXene−titanium carbide nanosheets (Ti3C2Tx-NS) and monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SARS-CoV-2 mAb) to design a point-of-care device for detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 NP) antigen. Few-layered titanium carbide nanosheets (denoted as FL-Ti3C2Tx-NS) have been synthesized using a single-step etching and delamination method and characterized using optical and electron microscopy techniques revealing the suitability for immunosensing applications. Binding studies revealed the excellent affinity between the biosensor and the SARS-CoV-2 NP. Electrochemical detection of SARS-CoV-2 NP is performed using differential pulse voltammetry and read by a smartphone-based user interface. The proposed FL-Ti3C2Tx-NS based biosensor offers the detection of SARS-CoV-2 NP with a limit of detection of 0.91 nM in a wide detection range in spiked saliva samples. Additionally, there is no cross-reactivity in the presence of potential interferants like SARS-CoV-2 spike glycoprotein and bovine serum albumin. These findings demonstrate the potential of MXenes in developing a rapid and reliable tool for SARS-CoV-2 NP detection. While we report the biosensing of SARS-CoV-2 NP, our system also paves the way for the detection of other SARS-CoV-2 antigens like spike protein or other biomolecules based on antigen−antibody interactions.
A vast number of emerging pollutants is being detected in the environment. Another lingering problem are health-threatening contaminants, such as mycotoxins, that deteriorate food and feed, and the pathogens themselves. Analytical methods, suitable for trace analysis, are needed that are desirably also fast, inexpensive and, if possible, robust and portable. It is set out, how immunoana-lytical, i.e., antibody-based methods, which are elaborated in a broad range of formats, can be profitably used to gain insights on the distribution and concentration trends of the target analytes at the point-of-need.
Immunoanalytical Techniques, i.e., antibody-based analytical methods, have been used for decades in clinical diagnostics. What makes them attractive for other fields of application is their short time-to-result and high sensitivity. Microplate-based assays such as ELISA have been adopted early in environmental and food analysis. Yet, to make immunoassays even faster, more sensitive, robust, and, most desirable, portable, advanced materials, sometimes developed for other purposes, can be profitably used to achieve these goals. Materials can be novel labels, e.g., chemical or particle labels, such as fluorophores or nanoparticles. Carrier particles, such as magnetic or polymer beads, make it possible to adopt the assays to meso- or microfluidic set-ups and encoding them opens the path to multiplex analysis. Specialty electrodes can enable for higher sensitivity in electrochemical detection. All this broadens the scope of application and lowers effort and cost for analysis at the point-of-need.
In urban waters, a multitude of organic micropollutants, often termed emerging pollutants, has been found over the last decades. Analytical methods suitable for trace analysis are needed that are desirably also fast, inexpensive and, if possible, robust and portable. Immunoanalytical, i.e., antibody-based, methods which are available in a broad range of formats, can be profitably used here to screen for the distribution and to monitor the trends of concentration levels of contaminants of emerging concern in the environment. Some of these formats are single-analyte but high-throughput methods. To use them wisely, indicator substances, sometimes called anthropogenic markers, should be selected and used in screening approaches, i.e., as indicators for contamination and the pre-selection of samples at which to have a closer look by multiplex methods like LC-MS/MS. Other methods are suitable to be performed on portable instrumentation in the field (on-site) or in facilities such as wastewater treatment plants for on-line monitoring of the treatment and elimination process. Furthermore, array technologies have been established that allow for parallel (multiplex) analysis of several analytes of interest.
The microtiter-plate based ELISA (Enzyme-linked Immunosorbent Assay) is the method of choice for the analysis of a large number of samples [1]. ELISAs are available to monitor for anthropogenic markers such as the antiepileptic carbamazepine, the analgesic diclofenac, the antihistaminic cetirizine, the steroid hormone estrone, the antimicrobial sulfamethoxazole, psychoactive caffeine and cocaine, the priority pollutant bisphenol A, and the bile acid isolithocholic acid. For on-site screening and monitoring, simpler formats, like mix-and-read assays, e.g., the Fluorescence Polarization Immunoassay (FPIA) [2] or Lateral-flow Immunoassays (LFIA) [3] are more suitable tools, the latter based on dipsticks or little cassettes, with which users have become very familiar during the COVID-19 pandemic via rapid antigen tests. The suitability of multi-analyte formats such as immunomicroarrays depends on the choice of a signal-producing system that provides small uncertainties and good reproducibility of the measurements. Bead-based (“suspension”) arrays, read out in flow cytometers, are a powerful platform for multiplex assays [4]. Electrochemical formats, run on portable devices, provide additional advantages as no light source is required. They are most promising for stand-alone analysers and biosensors [5].
The speed, low cost and on-site capabilities of these methods allow to gather a lot more data on anthropogenic compounds which enables to quantify inputs, differences in degradation power of elimination processes, dilution phenomena and a more precise image of individual water cycles which is demonstrated by several examples.
Analytical methods based on the selectivity of antibodies, often called immunoassays, are a back-bone of clinical laboratory diagnostics. To bring them to the field, i.e., to make immunoanalytical methods portable, hopefully even faster, more sensitive, and robust, advanced materials are re-quired. Materials can be novel labels, e.g., chemical or particle labels, such as fluorophores or na-noparticles. Carrier particles, such as magnetic or polymer beads, make it possible to adopt the as-says to meso- or microfluidic set-ups and encoding them opens the path to multiplex analysis. Spe-cialty electrodes can enable for higher sensitivity in electrochemical detection. Without research into better materials, efforts to bring analysis to the point-of-need will not bear fruit.
Vortrag zum Kick-off des Projektes.
Ziel des Projektes ist es, die Eignung der Bestimmung eines oder mehrerer der genannten anthropogenen Marker im Abwasser zur Volumenkorrektur („Kalibration“) im SARS-CoV-2-Monitoring von Abwässern auf der Basis eines von der BAM zu erhebenden Messdatensatzes zu evaluieren.
ESI-CorA ist ein nationales Verbundprojekt mit dem Ziel des Nachweises von SARS-CoV-2 im Abwasser.
Das UBA hat als Teilprojekt das Projekt MARKERIA (VH1802) an die BAM vergeben.
Ziel des Projektes ist es, die Eignung der Bestimmung eines oder mehrerer der genannten anthropogenen Marker im Abwasser zur Volumenkorrektur („Kalibration“) im SARS-CoV-2-Monitoring von Abwässern auf der Basis eines von der BAM zu erhebenden Messdatensatzes zu evaluieren.
1. Projektreffen mit dem Umweltbundesamt für das Projekt MARKERIA (VH1802).
Ziel des Projektes ist es, die Eignung der Bestimmung eines oder mehrerer der genannten anthropogenen Marker im Abwasser zur Volumenkorrektur („Kalibration“) im SARS-CoV-2-Monitoring von Abwässern auf der Basis eines von der BAM zu erhebenden Messdatensatzes zu evaluieren.
2. Projekttreffen mit dem Umweltbundesamt zum Projekt MARKERIA (VH1802).
Ziel des Projektes ist es, die Eignung der Bestimmung eines oder mehrerer der genannten anthropogenen Marker im Abwasser zur Volumenkorrektur („Kalibration“) im SARS-CoV-2-Monitoring von Abwässern auf der Basis eines von der BAM zu erhebenden Messdatensatzes zu evaluieren.
In Coastal Systems, pollutants as pharmaceutical drugs exert changes from the molecular to the organism level in marine bivalves. Besides pollutants, Coastal Systems are prone to changes in environmental Parameters, as the alteration of salinity values because of Climate Change. Together, these Stressors (pharmaceutical drugs and salinity changes) can exert different threats than each Stressor acting individually; for example, salinity can change the physical-chemical properties of the drugs and/or the sensitivity of the organisms to them. However, limited Information is available on this subject, with variable results, and for this reason, this study aimed to evaluate the impacts of salinity changes (15,25 and 35) on the effects of the antiepileptic carbamazepine (CBZ, 1 (ig/L) and the antihistamine cetirizine (CTZ, 0.6 pg/L), when acting individually and combined (CBZ + CTZ), in the edible clam Ruditapes philippinarum. After 28 days ofexposure, drugs concentrations, bioconcentration factors and biochemical parameters, related to clam's metabolic caparity and oxidative stress were evaluated. The results showed that dams under low salinity suffered more changes in metabolic, antioxidant and biotransformation activities, in comparison with the remaining salinities under study. However, limited impacts were observed when comparing drug effects at low salinity. Indeed, it seemed that CTZ and CBZ + CTZ, under high salinity (salinity 35) were the worst exposure conditions for the dams, since they caused higher leveis of cellular damage. It Stands out that salinity changes altered the impact of pharmaceutical drugs on marine bivalves.