Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
- 2016 (439) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (439) (entfernen)
Sprache
- Englisch (382)
- Deutsch (55)
- Italienisch (1)
- Mehrsprachig (1)
Schlagworte
- XPS (10)
- Corrosion (8)
- Fluorescence (7)
- ICP-MS (7)
- NDT (7)
- EBSD (6)
- Microstructure (6)
- Prozessanalytik (6)
- Computed tomography (5)
- Graphene (5)
In coal-fired power plants using oxyfuel combustion process with carbon capture and sequestration, instead of air, a mixture of oxygen and recirculated flue gas is injected in the boiler. A series of steels were exposed to CO2-SO2-Ar-H2O gas mixtures at 600 °C for 1000 h to compare their high temperature corrosion behavior. During the corrosion process, carburization, decarburization and recrystallization were observed underneath the oxide scale depending on the gas mixture and alloy composition. The conditions that lead to carburization are not yet completely understood, but decarburization can be simulated using thermodynamic and kinetic models. In this work, the results of these simulations are compared with measured values for one of the alloys that displayed a decarburized region. Since the mobility of carbon in the scale is not known, two strategies were adopted: simulation of alloy-atmosphere contact; and estimation of the carbon flux to produce the observed decarburization. The second approach might give an insight on how permeable to carbon the scale is.
Various methods have been used for introducing fire retardant additives into polymers. Deposition of thick fire retardant coatings directly onto polymer substrates is an alternative technique. An important Advantage of the coating technique is the preservation of the physical and chemical integrity of the polymer material. Moreover, the fire retardancy of the polymer materials can be achieved following their production. Suitable coating materials are inorganics, intumescent, char-forming, oxygendiluting, and cooling or radical quenching layers. The most important problem is to achieve sufficient coating thickness to withstand the direct attack of flame and to protect the polymer bulk from pyrolysis, otherwise blistering of coating, caused by emitted pyrolysis gases, is often observed.
To avoid blistering of coating, the adhesion between polyolefin Substrate and fire retardant coating has to be extraordinarily high.
In order to achieve such a high level of adhesion, the polymer surface has to be modified with adhesion-promoting functional groups. The deposition of thin plasma polymers as adhesion-promoting layers with NH2, OH or COOH groups has been the most suited method. These functional groups are able to form covalent bonds and other interactions between the fire-resistant coating and the plasma-modified polyolefin substrate.
Additionally, the plasma polymer counteracts the strong mechanical stresses in the laminate on exposure to high temperatures by its flexibility. The thick fire retardant coatings were chosen based on “green” ecological aspects to avoid flame-initiated emission of toxic or corrosive gases and remains of toxic char.
Der vorliegende Fachartikel stellt die wichtigsten zerstörungsfreien Prüfmethoden zur Qualitätssicherung von dünnen Strukturklebungen vor. Auf diese Weise wird ersichtlich, welche Methoden neben der zerstörenden Prüfung von dünnen Strukturklebungen eingesetzt werden können, um einen Haftfestigkeitsverlust zu detektieren. Steigende Leichtbau- und Dämpfungsanforderungen an großflächige Blechbauteile sorgen trotz erhöhter Kosten für einen zunehmenden Einsatz von modernen hybriden Schichtverbundwerkstoffen in zahlreichen Konstruktionsanwendungen. In der Luft- und Raumfahrtindustrie gehören solche Werkstoffe seit geraumer Zeit zum aktuellen Stand der Technik, wohingegen diese Werkstoffkonzepte in der mobilen Großserie derzeit nur selten zum Einsatz kommen. Neben dem Materialversagen der einzelnen Schichten von Schichtverbundwerkstoffen spielt das interlaminare Versagen der Schichten untereinander eine entscheidende Rolle. In der Umformtechnik ist es möglich, dass die polymere Zwischenschicht und das Deckblech nach der Umformung noch in Kontakt stehen, obwohl die Scherfestigkeit bereits überschritten wurde. Dieser Kraftschluss der beiden Fügepartner resultiert aus den schwachen Van-der-Waals-Kräften, die eine eindeutige Detektion mit Hilfe von zerstörungsfreier Prüfung erschweren. Die vorliegende Publikation soll die Eignung diverser zerstörungsfreier Prüfverfahren auf die Detektion von sogenannten „kissing bonds“ (schwaches Anhaften der Schichten nach Versagen der Verbindung) überprüfen.
Focus of this work is the detection of vertical movements behind the casing of groundwater observation wells within the seal. A new multi-methodical and azimuthal logging tool, named Azimuthal-Annulus-Convection-Identification (AACI)-Log has been developed and tested. The measurement concept of this probe is based on the combination of three azimuthal measuring logs – contact temperature on the inside of the casing wall, backscattered gamma-rays (gamma-gamma density), and natural radioactivity (gamma ray). Consequently, a direction-oriented image of the annular space can be derived. Not only the reason (void, potential channel) but also the resulting effect (vertical movement of fluids) can be detected with the Azimuthal-Annulus-Convection (AACI) – Log at the same time.
Visualization of surface modifications may be very challenging for coating/substrate systems of either almost identical optical constants, e.g. transparent films on substrates of the same material, or minor film thickness, substance quantity and affected area, e.g. ultra-thin or island films. Methods for visualization are optical microscopy (OM), imaging ellipsometry (IE), and referenced spectroscopic ellipsometry (RSE). Imaging ellipsometry operates at oblique incidence near Brewster angle of the bare, clean or unmodified substrate. In this configuration, reflected intensities are rather weak. However, the contrast to add-on and sub-off features may be superior. Referenced spectroscopic ellipsometry operates in a two-sample configuration but with much higher intensities. In many cases, both ellipsometric techniques reveal and visualize thin films, printed-pattern, laser-induced changes, and impurities better than optical microscopy. In particular for stratified homogeneous modifications, ellipsometric techniques give access to modelling and hence thickness determination. Modifications under investigation are polymer foil residue on silicon, laser-induced changes of ta-C:H coatings on 100Cr6 steel, imperfections of ta-C:H on thermal silicon oxide, degradation of glass, thin film tin oxide pattern on silicon, printed and dried pattern of liquids such as deionized water, cleaning agents, and dissolved silicone. © 2016 Elsevier B.V. All rights reserved.
On April 23rd 2013 at 2:07 a.m., a 1.3 kg meteorite fell in the Braunschweig suburb Melverode (52° 13′ 32.19″ N. 10° 31′ 11.60″ E). Its estimated velocity was 250 km/h and it formed an impact pit in the concrete fall site with a diameter of 7 cm and a depth of 3 cm. Radial dust striae are present around the impact pit. As a result of the impact, the meteorite disintegrated into several hundred fragments with masses up to 214 g. The meteorite is a typical L6 chondrite, moderately shocked (S4) – but with a remarkably high porosity (up to 20 vol%). The meteorite was ejected from its parent body as an object with a radius of about 10–15 cm (15–50 kg). The U,Th-He gas retention age of ∼550 Ma overlaps with the main impact event on the L-chondrite parent body ∼470 Ma ago that is recorded by many shocked L chondrites. The preferred cosmic-ray exposure age derived from production of radionuclides and noble gas isotopes is (6.0 ± 1.3) Ma.
Quantification of microbial load in diesel storage tanks using culture- and qPCR-based approaches
(2016)
Microbial contamination of fuels, associated with a wide variety of bacteria and fungi, leads to decreased product quality and can compromise equipment performance by biofouling and microbiologically influenced corrosion of pipelines and storage tanks. Detection and quantification of biomass are critical in monitoring fuel systems for an early detection of microbial outbreaks. The aims of this study are (i) to quantify bacterial and fungal contamination in samples from diesel storage tanks of petrol stations, using both culture dependent- and culture independent (qPCR) approaches, and (ii) to analyse the diversity of cultivable diesel-contaminating microorganisms with the purpose to create a strain collection for further use in biodeterioration experiments. Both methodological approaches revealed a high microbial contamination in all studied samples, with the bacterial load being much higher than the fungal load. The diversity of cultivable microorganisms was rather low. Based on criteria of abundance and fuel degradation potential, the most relevant microorganisms were identified as bacteria of genera Bacillus, Citrobacter, Burkholderia and Acetobacter, the filamentous fungi Paecilomyces variotii and Pseudallescheria boydii, and a Dipodascaceae yeast. Furthermore the validity and utility of qPCR-based methods are discussed.
There is currently a debate within the SIP community about the characteristic textural length scale controlling relaxation time of consolidated porousmedia.One idea is that the relaxation time is dominated by the pore throat size distribution or more specifically the modal pore throat size as determined in mercury intrusion capillary pressure tests. Recently new studies on inverting pore size distributions from SIP data were published implying that the relaxation mechanisms and controlling length scale are well understood. In contrast new analytical model studies based on the Marshall-Madden membrane polarization theory suggested that two relaxation processes might compete: the one along the short narrow pore (the throat) with one across the wider pore in case the narrow pores become relatively long.
This paper presents a first systematically focused study into the relationship of pore throat sizes and SIP relaxation times. The generality of predicted trends is investigated across a wide range of materials differing considerably in chemical composition, specific surface and pore space characteristics. Three different groups of relaxation behaviors can be clearly distinguished. The different behaviors are related to clay content and type, carbonate content, size of the grains and the wide pores in the samples.
Inductively coupled plasma mass spectrometry (ICP-MS) is a well-established analytical method for multi-elemental analysis in particular for elements at trace and ultra-trace levels. It has found acceptance in various application areas during the last decade. ICP-MS is also more and more applied for detection in the life sciences. For these applications, ICP-MS excels by a high sensitivity, which is independent of the molecular structure of the analyte, a wide linear dynamic range and by excellent multi-element capabilities. Furthermore, methods based on ICP-MS offer simple quantification concepts, for which usually (liquid) standards are applied, low matrix effects compared to other conventional bioanalytical techniques, and relative limits of detection (LODs) in the low pg g−1 range and absolute LODs down to the attomol range.
In this chapter, we focus on new applications where the multi-element capability of ICP-MS is used for detection of lanthanoides or rare earth elements, which are applied as elemental stains or tags of biomolecules and in particular of antibodies.
Inductively coupled plasma mass spectrometry (ICP-MS) is based on formation of positively charged atomic ions in a high-frequency inductively coupled Argon plasma at atmospheric pressure. The ions are extracted and transferred from the plasma source into a mass analyzer operated at high vacuum via an interface equipped with a sampling and a skimmer cone. The ions are separated in the mass analyzer according to their charge to mass ratio. The ions are converted at a conversion dynode and are detected by use of a secondary electron multiplier or a Faraday cup.
From an analytical point of view, ICP-MS is a well-established method for multi-elemental analysis in particular for elements at trace- and ultra-trace levels. Furthermore, methods based on ICP-MS offer simple quantification concepts, for which usually (liquid) standards are applied, low matrix effects compared to other conventional analytical techniques, and relative limits of detection (LODs) in the low pg g−1 range and absolute LODs down to the attomol range. For these applications, ICP-MS excels by a high sensitivity which is independent of the molecular structure and a wide linear dynamic range. It has found acceptance in various application areas and during the last decade ICP-MS is also more and more applied for detection of rare earth elements particularly in the life sciences.
Due to the fact that all molecules introduced into the high temperature of the plasma in the ion source were completely dissociated and broken down into atoms, which are subsequently ionized, all elemental species information is completely lost. However, if the different species are separated before they enter the plasma by using adequate fractionation or separation techniques, then ICP-MS can be used as a very sensitive element-specific detector. We will discuss this feature of ICP-MS in this chapter in more detail at hand of the speciation of gadolinium-containing contrast agents.
In coal-fired power plants using oxyfuel combustion process with carbon capture and sequestration, instead of air, a mixture of oxygen and recirculated flue gas is injected in the boiler. A series of steels were exposed to CO2-SO2-Ar-H2O gas mixtures at 600 °C for 1000 h to compare their high temperature corrosion behavior. During the corrosion process, carburization, decarburization and recrystallization were observed underneath the oxide scale depending on the gas mixture and alloy composition. The conditions that lead to carburization are not yet completely understood, but decarburization can be simulated using thermodynamic and kinetic models. In this work, the results of these simulations are compared with measured values for one of the alloys that displayed a decarburized region. Since the mobility of carbon in the scale is not known, two strategies were adopted: simulation of alloy-atmosphere contact; and estimation of the carbon flux to produce the observed decarburization. The second approach might give an insight on how permeable to carbon the scale is.
The relevance of the COOMET.QM-S5 comparison is founded on tightening of requirements to a control of automobile emissions (realization of environmental standards of EURO 4, EURO-5). Participating laboratories: VNIIM, BAM, BelGIM, Ukrmetrteststandart, KazInMetr. This comparison was carried out in 2013-2014. This supplementary comparison supports CMC claims for: CO2 in the range (4–16) 10⁻² mol/mol; CO in the range (0.5–5) 10⁻² mol/mol; C3H8 in the range (0.01–0.3) 10⁻² mol/mol. Results:
Component CO:
All laboratories identified the values of carbon monoxide mole fraction in the gas mixture within ±0.9134%.
Component CO2:
All laboratories identified the values of carbon dioxide mole fraction in the gas mixture within ±0.3042%.
Component C3H8:
All laboratories identified the values of propane mole fraction in the gas mixture within ±0.443%.
This key comparison aims to assess the capabilities of the participants to determine the amount-of-substance fraction oxygen in nitrogen. The GAWG has classified this as a track B comparison, due to the unexpected 50 μmol/mol argon mole fraction content of the transfer standards, which effects the achievable performance of some measurement techniques such a GC-TCD. The separation of oxygen and argon is challenging, and not all systems in use are equally well designed for it. As this analytical challenge due to a substantial fraction of argon in the transfer standards became a reality, the Gas Analysis Working Group (GAWG) decided to qualify this key comparison as a regular key comparison and not as a core comparison, which may be used to support calibration and measurement capabilities (CMCs) for oxygen in nitrogen, or for oxygen in nitrogen mixtures containing argon only (see also the section on support to CMCs).
Gas cylinders made of composite materials receive growing popularity in light-weight applications. Current standards are mostly based on safety determination relying on minimum amounts of endured load cycles and a minimum burst pressure of a small number of specimens. This paper investigates the possibilities of a probabilistic strength assessment for safety improvements as well as cost and weight savings. The probabilistic assessment is based on destructive testing of small sized samples. The influence of sample size on uncertainty of the assessment is analysed. Furthermore, methods for the assessment of in-service ageing (degradation) are discussed and displayed in performance charts.
It has been shown that selected types of substituents are able to vary the oxidative behavior of multi-walled carbon nanotubes. Such substituents investigated were sterically hindered secondary amino groups bonded in grafted piperidine units and covalently bonded bromine groups. Their interference and activity was preliminary determined in the model cumene and then in oil diesel fraction and low density polyethylene oxidation reactions. Results obtained indicate that chemical linking of amine moieties containing –NH groups directly to the carbon nanotubes core significantly increases their intrinsic anti-oxidative capacity while the grafting of Br-groups provokes the opposite functioning of the pristine samples. This inference was proved by thermogravimetric and differential thermal analysis of the polyethylene composites and experiments on profound aerobic oxidation of petroleum naphthenic fraction derived from the commercial Baku oils blend diesel cut.
The preparation and characterization of a Titanium dioxide (TiO2) by a simple, cost effective, facile and eco-friendly green synthesis method using Peltophorum pterocarpum plant extract is presented. The green synthesized nanoparticles were characterized using X-ray diffraction (XRD), Raman spectroscopy, High-resolution transmission electron microscopy (HR-TEM) and X-ray absorption near edge spectroscopy (XANES). XRD results show that the prepared TiO2 NPs were significantly crystalline with various percentages of anatase and rutile phases. The nanoparticles were found to have different diameters ranging from 20 to 80 nm. No evidence of any intermediate or different TiO2 phases were found in XANES measurements performed at the Ti K- and L-edge. It is shown that the TiO2 NPs with high uniformity, high surface area and minimum aggregation can be prepared with relative ease and the desired anatase: rutile phase ratio can be obtained by controlling the experimental conditions.
Quality control requirements imposed on assays used in clinical diagnostics and point-of-care-diagnostic testing (POCT), utilizing amplification reactions performed at elevated temperatures of 35 to 95 °C are very stringent. As the temperature of a reaction vessel has a large impact on the specificity and sensitivity of the amplification reaction, simple tools for local in situ temperature sensing and monitoring are required for reaction and assay control. We describe here a platform of stem-and-loop structured DNA hairpins (molecular beacons, MBs), absorbing and emitting in the visible and red spectral region, rationally designed for precise temperature measurements in microfluidic assays for POCT, and their ap-plication for temperature measurements in a common DNA-based molecular biological assay utilizing thermophilic helicase-dependent amplification (tHDA). Spectroscopic studies of these MBs, rationally designed from DNA se-quences of different thermal stabilities, chosen not to interact with the DNA probes applied in the nucleic acid amplification assay, and temperature-dependent fluorescence measurements of MB-assay mixtures revealed the suitability of these MBs for temperature measurements directly in such an assay with a temperature resolution of about 0.5 °C without interferences from assay components. Combining two spectrally distinguishable MBs provides a broader response range and an increase in temperature sensitivity up to 0.1 °C. This approach will find future application for temperature monitoring and quality control in commercialized diagnostics assays using dried reagents and microfluidic chips as well as assays read out with tube and microplate readers and PCR detection systems for temperature measurements in the range of 35 to 95 °C.
Microstructure-property connections for porous ceramics: The possibilities offered by micromechanics
(2016)
Microstructure of porous ceramics is highly “irregular”: it comprises pores and microcracks of diverse shapes and orientations.
This makes their quantitative modeling challenging, and one
often resorts to empirical relations containing Fitting Parameters and having somewhat uncertain range of applicability. We review the substantial progress made in modeling of “irregular” microstructures that does not seem to have been sufficiently utilized in the context of ceramics. We discuss the possibilities offered by micromechanics in developing microstructure–property relations for porous microcracked ceramics. After an overview of relevant micromechanics topics, we focus on several issues of specific interest for ceramics: nonlinear stress–strain behavior, effective elastic properties, and thermally induced microcracking. We discuss extraction of microscale Parameters (such as strength of the intergranular cohesion, density of cracks and pores, etc.) from macroscopic data and identify the extent of uncertainty in this process. We also argue that there is no quantitative correlation between fracturing process and the loss of elastic stiffness.