Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (47)
- Zeitschriftenartikel (40)
- Posterpräsentation (9)
- Buchkapitel (2)
- Beitrag zu einem Sammelband (2)
- Beitrag zu einem Tagungsband (2)
- Sonstiges (2)
- Forschungsbericht (2)
Schlagworte
- Traceability (32)
- Metrology (30)
- Absolute isotope ratio (16)
- Uncertainty (13)
- Isotope ratio (11)
- CCQM (9)
- Delta value (7)
- Measurement uncertainty (7)
- Reference material (7)
- IDMS (6)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (65)
- 1.1 Anorganische Spurenanalytik (65)
- P Präsident (3)
- P.0 Präsident und andere (3)
- 1.4 Prozessanalytik (2)
- 1.3 Instrumentelle Analytik (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 6 Materialchemie (1)
- 6.3 Strukturanalytik (1)
- PST Präsidiale Stabsstelle (1)
Eingeladener Vortrag
- nein (47)
Soil certified reference material (CRM), UME EnvCRM 03 was produced by a collaborative approach among national metrology institutes, designated institutes and university research laboratories within the scope of the EMPIR project: Matrix Reference Materials for Environmental Analysis. This paper presents the sampling and processing methodology, homogeneity, stability, characterization campaign, the assignment of property values and their associated uncertainties in compliance with ISO 17034:2016. The material processing methodology involves blending a natural soil sample with a contaminated soil sample obtained by spiking elemental solutions for 8 elements (Cd, Co, Cu, Hg, Ni, Pb, Sb and Zn) to reach the level of warning risk monitoring values specified for metals and metalloids of soils in Europe. Comparative homogeneity and stability test data were obtained by two different institutes, ensuring the reliability and back up of the data. The certified values and associated expanded uncertainties for the total mass fractions of thirteen elements (As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Sb, V and Zn) are established. The developed CRM can be used for the development and validation of measurement procedures for the determination of the total mass fractions of elements in soil and also for quality control/assurance purposes. The developed CRM is the first example of a soil material originating from Türkiye.
The need for quality assessment of anthropogenic impact on environmental pollution is increasing due to discharge from various industries, the use of chemicals in agriculture and the consumption of fossil fuels. Diminishing resources such as natural waters used for the cultivation of agricultural products, plant and animal habitats are under severe pollution pressure and are at constant risk. Several parameters, such as Pb, Cd, Ni, Hg were listed by Water Framework Directive in Directive(2008/105/EC) in the priority substances. Cadmium and Hg were identified as priority hazardous substances whereas As is an important contaminant for its potential toxicological and carcinogenic effects. An inter-comparison study is organised in EURAMET TC-MC in order to demonstrate the capability participants for measuring five elements in river water. The participants carried out measurements for analytes: Pb, Cd, Ni and As as mandatory elements, and Se as an optional one. Participants were asked to perform the measurements with respect to the protocol provided. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Accurate and precise isotope ratio measurements of heavy elements are playing an increasinglyimportant role in modern analytical sciences and have numerous applications. Today, isotope ratio measurements are typically performed with two principal techniques: thermal ionization mass spectrometry (TIMS) and multiple collector-inductively coupled plasma mass spectrometry (MC-ICP-MS). To obtain accurate results by mass spectrometry, isotopic certified reference materials (iCRMs) are needed for mass bias correction and for the validation of the method used for analysis.Thus, it is of paramount importance to achieve measurement comparability of all data reported, and to assess measurement capability of each CRM producer/National Metrology Institute (NMI). Therefore, the international comparison (CCQM-P213) was performed to assess the analytical capabilities of NMIs for the accurate determination of copper isotope ratio delta values in high purity materials. The study was proposed by the coordinating laboratories, National Research Council Canada (NRC), National Institute of Standards and Technology (NIST), Bundesanstalt für Materialforschung und -prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB), as an activity of the Isotope Ratio Working Group (IRWG) of the Consultative Committee for Amount of Substance - Metrology in Chemistry and Biology (CCQM). Participants included six NMIs and one designated institute (DI) from the six countries. Although no measurement method was prescribed by the coordinating laboratories, MC-ICP-MS with either standard-sample bracketing (SSB) or combined SSB with internal normalization (C-SSBIN) models for mass bias correction were recommended. Results obtained from the six NMIs and one DI were in good agreement.
The reference method for obtaining absolute isotope ratios still is the isotope mixture approach. Due the huge efforts required the full isotope mixture approach is applied only by a few institutes worldwide. To enable an IRWG key comparison with a sufficiently large number of participants a proposal for absolute cu isotope ratios is presented where participants will be provided with the enriched isotopes, the isotope mixtures and the samples. In parallel a pilot study will be organized where alternative approaches for obtaining absolute Cu isotope ratios can be applied.
The variation of isotope ratios is increasingly used to unravel natural and technical questions. With new upcoming techniques and research topics in the last two decades, such as material provenance or food authenticity to animal and human migration studies, the number of published isotope data has strongly increased. Here, isotope reference materials are indispensable to enable a reliable method validation or even SI-traceability. The fast development and broad availability of inductively coupled plasma mass spectrometry instrumentation (ICP-MS) also lead to an expansion of the classical research areas and new elements are under investigation. Owing to this large expansion of the field, the production and certification of isotope reference materials for calibration and validation is lagging behind, even for classical applications such as conventional 87Sr/86Sr isotope ratio analysis. To improve this situation, BAM organized an interlaboratory comparison (ILC) comprising of thirteen international laboratories for the characterisation of 87Sr/86Sr isotope ratios in geochemical and industrial reference materials. Six reference materials (four cements and two rocks) were provided as powder requiring extensive sample preparation prior to isotopic measurement. Additional requirements included the use of the conventional method for obtaining 87Sr/86Sr isotope ratios, also known as radiogenic 87Sr/86Sr isotope ratios, and the assessment of the measurement uncertainty. The primary goal was to evaluate potential differences in the application of multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for conventional 87Sr/86Sr isotope ratio determination, with a secondary goal to provide reference values for the 87Sr/86Sr isotope ratios in these potential new reference materials. All reported results are accompanied by an uncertainty statement and are traceable to the conventional method, which will be described in detail within this presentation. Current state-of-the-art statistical models were used to ensure the proper evaluation of the reported results and their associated measurement uncertainties within the frame of this ILC. Combined with results from appropriate homogeneity assessment, reference values for 87Sr/86Sr isotope ratios will be assigned.
This study uses conventional 87Sr/86Sr and 143Nd/144Nd isotope and interelement ratios of Ca, Sr, K, Mn, Mg and Ti as fingerprints for provenancing ordinary Portland cements (OPC). Herein, the first database of Sr and Nd isotope ratios investigated in OPCs, stemming from 29 cement plants located worldwide, was created. The results show that the Sr isotope ratios of OPCs are higher than those of seawater from the observed geological period. The spread of 143Nd/144Nd in OPCs is not as large as the spread for 87Sr/86Sr isotope ratios. However, the combination of both Sr and Nd isotope ratios provides the potential for distinguishing between cements of different production sites. Most of the OPCs investigated have measurable differences in their 87Sr/86Sr and 143Nd/144Nd isotope ratios, which can be employed as a valuable analytical fingerprinting tool. In the case of equivocal results, divisive hierarchical clustering was employed to help overcome this issue. The construction of geochemical profiles allowed the computing of suitably defined distances between cements and clustering them according to their chemical similarity. By applying this methodology, successful fingerprinting was achieved in 27 out of the 29 ordinary Portland cements that were analysed.
Pb isotope ratio analysis
(2023)
Sr isotope ratio analysis
(2023)
Detector deadtime
(2023)