Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Dokumenttyp
Sprache
- Englisch (9)
Referierte Publikation
- ja (9)
Schlagworte
- ETV (2)
- Impurities (2)
- Atomic-absorption spectrophotometry (1)
- Boron carbide (1)
- Calibration (1)
- Certification (1)
- Certified reference material (1)
- Chemical analysis (1)
- Comparability (1)
- Copper (1)
Organisationseinheit der BAM
A method, based on electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICP OES), has been optimized for direct solid sampling analysis of soda-lime glass - the most common type of industrially manufactured glass. This method allows fast and reliable quantification of the main elements - Al, Ca, K, Mg, Na, and Si - and trace elements - As, Ba, Cd, Ce, Co, Cr, Cu, Fe, Mn, Mo, Ni, (P), Pb, Sb, (Se), Sn, Sr, Ti, V, Zn, and Zr. In the presented ETV-ICP OES method, calibration is performed predominantly with matrix-free synthetic samples. This metrological advantage is normally not achieved with direct solid sampling methods and is one of the goals of the present study. In a certification interlaboratory comparison for the soda-lime glass CRM BAM-S005c, 2 out of 16 laboratories employed the ETV-ICP OES method. An improved analytical performance was obtained compared with the results of laboratories that used conventional liquid ICP OES. For both methods, the average relative deviations between the laboratory results and certified values as well as the average values of relative standard deviation were with a few exceptions <10%, in most cases even <5%, which indicated high trueness and precision.
A magnetically stabilized DC arc device, designed for operation with OES spectrometers was used to determine the elements Ag, Al, B, Ba, Be, Ca, Co, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Mo, Na, Nb, Ni, Si, Sn, Sr, Ti, V, Zr at trace levels of some μg kg−1 up to some 10 mg kg−1 in graphite powders. The coil for the generation of the homogeneous magnetic field was placed outside the closed arc chamber. The time programs of variable current strengths of the magnetic coil (up to 6 A) and of the arc (up to 17 A) which was burning in air were computer controlled. Halogenating gases (mainly CCl2F2, alternatively SF6 and NF3) were used as chemical modifiers to allow an effective release of the carbide forming trace elements. The mass flow controlled modifier gas was led through a special carrier electrode near the arc plasma. The emission radiation was guided by an optical fiber alternatively into two different ICP spectrometers in which the ICP torches were removed. The synergistic interaction of the magnetic field with the halogenating modifier gases resulted in a significant improvement in the analytical performance of the optimized analytical method. All our results for 22 trace elements were in good agreement with the means of an inter-laboratory comparison by BAM for certification of a pure graphite powder material; this holds also for our results for two other graphite materials. The optimized method showed an analytical performance suitable for comprehensive trace analysis of pure graphite. The instrumentation could be integrated into modern DC arc emission spectrometers to improve their analytical capabilities substantially.
In supplementary work to the one published earlier, experiments with SF6, NF3, CF4 and H2 as new modifier gases for the matrix studied were performed. Our investigations were continued to improve the described analytical method and to achieve additional insights into the mechanism of analyte release. Our new survey is split in two parts. At first fluorinating modifiers were used to investigate the behaviour of a variety of trace elements (Ag, Al, As, Au, Bi, Cd, Co, Cr, Fe, Mg, Mn, Ni, P, Pb, Sb, Se, Si, Sn, Te, Ti, Zn and Zr). Most of them (exceptions Au, Se, and Te) could be effectively released from the copper matrix by thermo-halogenation reactions and by partial sub-sample evaporation. Using SF6 and NF3 as modifier gases, low limits of quantification (LOQs) were achieved for the 19 well released trace elements (typical ≤0.1 mg kg-1). Most elements (exceptions Ag, Mg, and Ni) could be calibrated by using aqueous calibration solutions without any sample pretreatment. For the trace determination of Se, Te, and Au, a further analytical method of ETV-ICP OES is described in the second part based on thermo-hydrogenation reactions by using a hydrogen/argon mixture as a modifier gas. The determination of Se and Te with very high analytical performance (LOQ < 0.1 mg kg-1) can either be carried out in a second analytical step succeeding the halogenation procedure, or the sub-sample is directly treated with H2 without previous halogenation procedure whereby the sub-sample can either be partially or totally evaporated. In this case some other analytes (Ag, Au, As, Bi, Cd, Fe, Mg, Ni, Pb, Sb, Sn, and Zn) can additionally be quantified simultaneously with Se and Te.
A candidate material for the use as primary standard for silver determination was characterized with respect to total purity. Except the radioactive elements and He, all possible impurities were considered. Based on glow discharge mass spectrometry, inductively coupled plasma-mass spectrometry and carrier gas hot extraction measurements, the demonstrated total purity and its standard uncertainty is w(Ag) = (99.999 52 ± 0.000 11) %. The purity value and its uncertainty is dominated by the contributions from the measurements of the nonmetallic impurities, namely S, N, C and O.
Within the scope of a project of the 'European Association of National Metrology Institutes' (EURAMET), a European metrological dissemination System (network) providing traceable reference values assigned to matrix materials for validation purposes is described and put to the test. It enables testing laboratories (TL) to obtain comparable results for measurements under the 'EU Water Framework Directive 2000/60/EC' (WFD) and thus, to comply with a core requirement of this very directive. The dissemination system is characterized by the fact that it is available to all laboratories throughout Europe which intend to perform measurements in the context of the WFD and that it can ensure sustainable metrological traceability to the International System of Units (SI) as a reference point for the measurement results. This Dissemination system is set up in a hierarchical manner and links up the level of the national metrology institutes (NMI) with that of the TLs via an intermediate level of calibration laboratories (CL) by comparison measurements. The CLs are expert laboratories with respect to the measurement of the analytes considered here (within the project, the CLs are called potential calibration laboratories (PCL)) and are additionally involved in the organization of comparison measurements within the scope of regional quality assurance (QA) systems.
Three comparison measurements have been performed to support the approach. A total of about 130 laboratories participated in this exercise with the focus on the measurement of the priority substances Pb, Cd, Hg, and Ni defined in the WFD. The elemental concentrations in the water samples roughly corresponded to one of the established environmental quality standards (EQS), the annual average concentration (AA-EQS), which is defined in the daughter Directive 2008/105/EC of the WFD. It turned out that a significant number of TLs still need to improve their measurement methods in order to be able to fulfill the Minimum requirements of the WFD, in particular, with regard to the elements Cd and Hg probably due to their low EQS values.
Furthermore, it became obvious that the hierarchical Dissemination system suggested here actually corresponds to the measuring capabilities of the three participating Groups (NMIs, PCLs, and TLs).
Inspired by the globule arc technique a new electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV-ICP OES) method was developed for the analysis of high-purity copper materials. The performance of the method was investigated for the analytes Ag, Al, As, Bi, Cd, Co, Cr, Fe, Mg, Mn, Ni, P, Pb, S, Sb, Se, Si, Sn, Te, Ti, Zn and Zr. ETV parameters were optimized regarding the release of the analytes, the transport efficiency and the quality of analytical results in terms of precision, trueness and power of detection. The influence of CCl2F2, CHClF2, C2H2F4 and CHF3 as gaseous halogenation modifiers was investigated. A sufficient in situ analyte matrix separation was achieved by using CHF3 as halogenating reagent avoiding a high matrix input from the molten copper sample into the ETV system and the plasma. A complete release from the samples was obtained for all investigated analytes except Se and Te. Acceptable results for the determination of the trace elements Ag, Al, As, Bi, Cd, Co, Cr, Fe, Mg, Mn, Ni, P, Pb, S, Sb, Si, Sn, Ti, Zn and Zr in high-purity copper were achieved. The method includes a preceding sample preparation step of oxidizing the surface of copper samples which results in a significantly enhanced sensitivity. In addition to the calibration with copper samples, the feasibility of the calibration with liquid multi-element solutions was investigated. Except for Ag, Mg and Ni all analytes could be analyzed using aqueous calibration solutions. The trueness of the method was tested by the determination of analyte contents of certified reference materials. Limits of quantification ranging from 0.6 ng g-1 to 29 ng g-1 were achieved. The developed direct solid sampling method is time and cost effective and well suited for the characterization of high-purity copper materials. The method can be automated to a large extent and is applicable for processes accompanying analyses. In contrast to all other investigated trace elements, Se and Te were not released from the matrix at measurable levels under the used conditions. The determination of these elements is still under investigation and will be reported in a succeeding publication.
The certification of a boron carbide reference material for chemical composition is described. The mass fractions of 16 elements and two boron species are certified in an international interlaboratory comparison with 35 participating laboratories from six different countries. Beside chemical characterization the certification process includes homogeneity and stability testing of the candidate material boron carbide (type F360, 305M422). Details of the analytical methods used for chemical characterization and of the calculation of the uncertainties of the certified mass fractions are given. The new reference material ERM®-ED102 with certified mass fractions of 18 parameters (elements and species) and of the amount fraction of the isotope 10B is a valuable tool for laboratories working in the field of advanced ceramic materials analysis to improve their analytical results.
Calibration of two commercially available glow discharge double focusing mass spectrometers, the VG 9000 and Element GD, is described using synthetic pin standards pressed from solution doped copper and zinc matrices. A special pressing die was developed for this purpose and optimal results were obtained with the highest possible pressures, i.e., 95 kN·cm- 2. This calibration approach permits the determination of trace element mass fractions down to µg·kg- 1 with small uncertainties and additionally provides traceability of the GD-MS results in the most direct manner to the SI (International System of Units). Results were validated by concurrent measurements of a number of compact copper and zinc certified reference materials. The impact of the sample pin cross-section (circular or square) was investigated with the use of a new pin-sample holder system for the Element GD. The pin-sample holder was designed by the manufacturer for pin-samples having circular cross-section; however, samples with square pin cross-section were also shown to provide acceptable results. Relative Sensitivity Factors for some 50 analytes in copper (VG 9000, Element GD) and zinc matrices (VG 9000) are presented. The field of applicability of GD-MS may be considerably extended via analysis of pin geometry samples based on their ease of preparation, especially with respect to the accuracy and traceability of the results and the enhanced number of analytes which can be reliably calibrated using such samples.
Determining the influence of impurities on the fixed-point emperatures
of the ITS-90 requires the completion of several tasks. In this paper, the Progress made at Physikalisch-Technische Bundesanstalt (PTB) and BAMFederal Institute for Materials Research and Testing is presented and remaining questions are discussed.
The projected characterization procedure at PTB, which is based on the established SIE method (sum of the individual estimates), using a new indium fixed-point cell is described as an example. This procedure includes an SI-traceable chemical Analysis of the material in the fixed-point cell with sufficiently low uncertainties, the individual experimental determination of the influence of the quantified impurities on the fixed-point temperature, and the establishment of direct links to the phase-transition temperatures of the national standard and of an assumed material of ideal purity.
A characteristic difference to the common practice is the chemical analysis of the fixed-point metal being done after determining the cells freezing temperature. This allows for the detection and consideration of contamination and purification effects due to the filling process, or due to the contact with the carbon crucible and other parts of the fixed-point cell. A chemical analysis of an indium fixed-point was carried out by BAM with relative measurement uncertainties below 30 % which have not been previously achieved. The results provide evidence for the precipitation of some impurities,
which is apparently inconsistent with the corresponding binary phase diagrams, but was explained in a recent publication. Implications for the use of the SIE method shall be described briefly at the end.