Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Dokumenttyp
- Vortrag (14) (entfernen)
Sprache
- Englisch (14)
Referierte Publikation
- nein (14)
Schlagworte
- Fluorescence (11)
- Microfluidics (3)
- Molecularly imprinted polymers (3)
- Sensor (3)
- Dyes (2)
- Mikrofluidik (2)
- PFAS (2)
- Particles (2)
- Probes (2)
- Sensing (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (14)
The development of a Lab-on-a-Chip (LoC) is presented, which can detect reactive phosphorous compounds in the gas phase in combination with an optochemical hand-held sensor. The LoC prototype contains three pairs of sensing materials containing fluorescent indicator dyes in various carrier materials. By measuring the fluorescence response to phosphoryl chloride, a surrogate compound, the detection of chemical warfare agents (CWAs) in gas phase becomes possible within seconds, introducing a novel approach to CWA detection.
In particular, the rapid development of lateral flow assays as indispensable tools for everyone to contain the SARS-CoV-2 pandemic has fuelled the global demand for analytical tests that can be used outside dedicated laboratories. In addition to their use in medical diagnostics, rapid tests and assays have become increasingly important in various fields such as food safety, security, forensics, and environmental management. The advantage is obvious: taking the assay directly to the sample minimizes the time between suspicion and decision-making, allowing faster action. Especially today, when mobile communication devices with powerful computing capabilities and built-in cameras are ubiquitous, more people than ever before around the world have the basic skills to operate a powerful detector at their fingertips. This sets the stage for a much wider use of analytical measurements in terms of prognosis and prevention, enabling professional laypersons in particular.
However, current strip-based systems are primarily focused on single parameter analysis, whether it is SARS-CoV-2 biomarkers, blood glucose levels, or lead concentrations in water samples. Industrial applications of such methods also often still rely on single-parameter assays, requiring multiple runs even for a limited number of key parameters. Overcoming these limitations depends on developing low-number multiplexing strategies that ensure robustness, reliability, speed, ease of use, and sensitivity.
This lecture will give an overview of several generic approaches developed in recent years to address these challenges. It will highlight how the synergy of supramolecular (bio)chemistry, luminescence detection, hybrid (nano)materials and device miniaturization can result in powerful (bio)analytical assays that can be used at a point-of-need.1-5 Selected examples will introduce key aspects of such systems that include tailored signaling mechanisms and recognition elements, materials functionalization and device integration, including hybrid nanomaterials, gated indicator release systems, strip modification, and smartphone-based analysis.
PFAS Sensors
(2023)
This contribution provides an introduction to the development of sensors for PFAS analysis, presents the most common approaches, and describes the opto-microfluidic strategy in combination with polymerizable indicators and detection matrices currently being pursued by the Chemical and Optical Sensing Division at BAM.
Microbial contamination of fuels by fungi or bacteria poses risks such as corrosion and fuel system fouling, which can lead to critical problems in refineries and distribution systems and has a significant economic impact at every stage of the process. Many factors have been cited as being responsible for microbial growth, like the presence of water in the storage tanks. In fact, only 1 % water in a storage system is sufficient for the growth of microorganisms like bacteria or yeasts, as well as for the development of fungal biomass at the oil/water interface.
This work presents a rapid test for the accurate determination of genomic DNA from aqueous fuel extracts. The detection is based on the use of polystyrene-mesoporous silica core-shell particles onto which modified fluorescent molecular beacons are covalently grafted. These beacons contain in the hairpin loop a target sequence highly conserved in all bacteria, corresponding to a fragment of the 16S ribosomal RNA subunit. The designed single-stranded molecular beacon contained fluorescein as an internal indicator and a quencher in its proximity when not hybridized. Upon hybridization in presence of the target sequence, the indicator and the quencher are spatially separated, resulting in fluorescence enhancement. To perform the assay the developed particles were deposited on different glass fibre strips to obtain a portable and sensitive rapid test. The assays showed that the presence of genomic DNA extracts from bacteria down to 50–70 μg L–1 induced a fluorescence response. The optical read-out was adapted for on-site monitoring by fitting a 3D-printed case to a conventional smartphone, taking advantages of the sensitivity of the CMOS detector. Such embedded assembly enabled the detection of genomic DNA in aqueous extracts down to the mg L–1 range and represents an interesting step toward on-site monitoring of fuel contamination.
Per- and polyfluoroalkyl substances (PFAS) are a class of man-made organo-fluorine chemicals that have become environmental contaminants of emerging concern, originating from a variety of materials such as adhesive, stain- and oil-resistant coatings, firefighting foams, etc. The high strength of this C-F bond makes PFAS thermodynamically stable and resistant to (bio)degradation, thus retaining them in the environment over time. Perfluoroalkyl carboxylic acids (PFCAs), one category of the most used PFAS, consist of a fully fluorinated carbon backbone and a charged carboxylic acid headgroup, and have been classified as Substances of Very High Concern (SVHC) and added to the REACH Candidate List due to their persistence in the environment, non-biodegradability and toxicological effects.[1-2] Traditional techniques for the analysis of PFCAs include GC-MS, HRMS and HPLC-based approaches, which are laborious, not portable, costly and require trained personnel. In contrast, fluorescence assays can be designed as easy-to-operate, portable and cost-effective methods with high sensitivity and fast response. Integration of fluorescent probes with an adequately miniaturized assay enables a promising alternative for PFCAs analysis.
Here, a novel guanidine fluorescent probe has been synthesized and fully characterized for the detection of PFCAs in a biphasic extract-&-detect assay. The fluorescent probe was then incorporated into polymeric matrices supported by a red dye-doped SiO2 nanoparticle to construct a dual-emission sensing platform. Such a system allows precise and selective detection of PFCAs, reducing the interference of competitors, matrix effects and other factors except for the PFCAs. The system was then employed in a droplet-based microfluidic setup which offers a portable and easy to operate detection platform.
The reversible analyte-induced switching between a colourless leuco form of a dye and its coloured all-π-conjugated form is one of the oldest concepts in probe- or indicator-based optical analysis,1 constituting so-called “one-color indicators”.2 In contrast to colour changes in the visible region, for which usually a bond-forming or a non-covalent interaction between a functional group on an indicator and an analyte is responsible, the extraordinarily large shifts of 150–250 nm seen for leuco-to-all-π-conjugated transformation are only possible when the reaction takes place directly at a site that is an intrinsic part of a dye’s π-system; the classic case are triphenylmethane dyes.3 Despite its obvious potential, this approach has not been a very popular area of scientific research for decades, perhaps because it is much more difficult to implement selectivity than by modifying terminal functional groups. However, in recent years, reaction-based fluorescence probes have attracted increasing attention by virtue of their superior sensitivity.4,5
Nowadays, rhodamines and fluoresceins are by far the most prominent groups of reaction-based indicators.5 They are usually switched between a colourless and non-fluorescent and a greenish-yellowish absorbing and yellowish-reddish emitting form. Typically, the coloured and fluorescent form is ionic, while the colourless form is neutral, reactions having mainly be designed to occur at the end groups of the xanthenoid π-system. BODIPY dyes, with their favourable spectroscopic and chemical properties as well as facile wavelength tunability features have only very recently been explored into this direction.6,7 Reaction at the core dipyrrin framework of these dyes led to strong colour and fluorescence modulations with potential applications in materials sciences6 and cell imaging.7 The present contribution will highlight the mechanisms at play and the sensing performance realized so far, and will compare core-reactive approaches to reaction-based signalling that involves π-extension of BODIPYs.8,9
Chlorination of pool water and wastewater, in food and pharmaceutical production, as well as in pesticide and paper manufacturing is a routinely used technique. However, the amount of chlorine in water must be strictly adjusted, to ensure enough concentration to kill pathogenic bacteria and viruses, while preventing too high concentrations inducing negative effects on human health. As an indicator, a molecular fluorescent probe based on a BODIPY structure was designed. This indicator exhibits a sensitive and selective fluorescence response upon increasing concentrations of hypochlorite in aqueous solvent mixtures. Real-time analyses became possible after the integration of this fluorescent indicator into newly designed 2D & 3D microfluidic chips incorporating a passive sinusoidal mixer and a micro-hydrocyclone, respectively. A comparison of the two microfluidic systems, including their ability to prevent accumulation or circulation of microbubbles, has shown excellent fluidic behaviour for the micro-hydrocyclone device. This system was distinctly more robust against gas bubbles, showed a higher signal gain and allowed to halve the limit of detection to 0.02 mg L–1. The use of the 3D system to quantify the chlorine content of pool water samples for sensitive and quantitative chlorine monitoring has been demonstrated.
Supramolecular chemistry, fluorescence detection, hybrid (nano)materials and device miniaturization are in themselves highly interesting areas of research, yet especially their combination paves the way to (bio)chemical analysis systems that show outstanding performance. The lecture gives an overview of the toolbox of single components developed in BAM’s Chemical and Optical Sensing Division over the years, and how their combination can result in powerful sensors, quick tests and assays. While at the core of a development is the analytical problem, that is, the determination of a certain analyte in a sample of interest with the required sensitivity and selectivity by a specific end user in a given setting, signaling mechanisms, recognition elements, signal transduction modes, materials functionalization, device design and system integration are adequately chosen, tailored and adapted. Examples including molecularly imprinted polymers, hybrid mesoporous nanomaterials, gated indicator release systems, microfluidic devices, test strips and smartphone-based analysis will be presented.
Molecularly Imprinted Polymers with Integrated Fluorescence as Versatile Biomimetic Sensing Matrices
(2018)
Molecularly imprinted polymers (MIPs) are an established, versatile and high-performance matrix for the selective separation or enrichment of (bio)chemical species, especially small molecules of biochemical or environmental relevance. MIPs are prepared through the polymerization of a mixture of functional monomers and cross-linkers in the presence of the template with subsequent extraction of the latter. Conceptionally, this process can be seen as mimicking in a strongly accelerated, though single-step manner a biological process such as antibody formation. Because the resulting MIPs contain cavities in their matrix that are complementary in size, shape and electronic/ electrostatic or hydrogen bonding demand to the imprinted target molecule or template, these polymers are frequently termed “artificial antibodies”. Compared to natural antibodies, they are chemically and physically much more robust. Regarding sensitivity and selectivity, however, there is still a gap to bridge before MIPs can fully compete with antibodies.
Another favorable aspect that distinguishes MIPs from antibodies is that they can be endowed with an explicit function, allowing the use of MIPs in applications that require more than only an efficient binder. For instance, if specifically designed and polymerizable fluorescent indicators are integrated as functional monomers into a MIP, direct fluorescence sensing can be accomplished. Because MIPs can be prepared in a variety of different formats, their combination with miniaturized or other specific analytical techniques or sensory devices is possible, especially when the transduction mode is light. This presentation will introduce basic design considerations, challenges, limitations and the potential that lies with such sensor materials with some recent examples of our group, targeting various organic oxoanions as analytes.
The detection of potential contaminants as early as possible and as close to their point of emission as well as immission is becoming increasingly important in contemporary environmental analytical chemistry. In addition, real-time monitoring of important chemical parameters for process control is strongly gaining relevance within the context of Industry 4.0. Not only is the development of powerful optical probes thus necessary but also their integration into a matrix and/or device that allows for the application of such systems in realistic measurement scenarios. Integrating fluorescent probes with sensing matrices, however, presents a major challenge because usually, when confined in a rather rigid matrix, fluorophores tend to behave completely different than for instance in the molecular state in solution. The present contribution will highlight recent examples of successful integration of BODIPY (boron–dipyrromethene) based probes with devices that have been developed in our group.
A simple system utilizing a test strip for direct readout with a conventional miniaturized camera as for instance routinely used in smartphones was recently devised by us for the determination of organophosphate nerve or chemical warfare agents (CWAs) Sarin (GB), Soman (GD), and Tabun (GA) in aqueous environments. Here, we coupled a reactive BODIPY to the inner and outer surface of mesoporous silica nanoparticles. In the presence of CWAs, the reactive BODIPY dye with an optimally positioned hydroxyl group undergoes an acylation reaction, yielding a bicyclic product that is non-emissive. The strong fluorescence quenching response allows reaching LODs in the pM range in natural waters.
Steric embedding, again relying on test strip analysis in combination with a smartphone-based readout and data processing, was sufficient to create a reusable optical pH stick. The family of pH-responsive fluorescent BODIPY probes used for this purpose has been designed in a rational manner with the aid of quantum chemistry tools. All the probes display very similar spectroscopic properties with ON−OFF fluorescence switching responses, being retained after embedding of the probes into hydrogel sensor spots on a plastic strip.
Dispensing with a matrix yet invoking microfluidic chips finally permits to use a highly sensitive boronic acid-functionalized BODIPY probe for in-line sugar analysis for instance in the beverage industry. Placement of an amino group in direct neighbourhood of the boronic acid moiety yielded a broad working range at neutral pH while meeting the desired sensitivity in the micro-molar range due to a pronounced analyte-induced fluorescence increase, guaranteeing the straightforward detection of sugar in (coloured) sodas without sample clean-up.