Iron isotopes are used in a variety of fields from e.g., geologic question to medical applications. Measurements of iron isotopes are usually performed as delta measurements to an artificial based delta zero standard. In the case of Fe isotopes is that delta zero standard IRMM-014, a pure Fe metal. Unfortunately, that conventional delta zero reference material defining the 56/54Fe scale is out of stock and therefore unavailable. To overcome that situation and fulfill the need for laboratories that measure Fe isotope on a regular basis we will provide a set of solutions with IRMM-014 and a second anchor point for Fe isotope ratio measurements that is based on a pure Fe metal. This new second anchor point, a high purity Fe from BAM, will be calibrated against IRMM-014 and can be used as bracketing standard or as reference value for stable Fe isotope measurements.
We are in the good situation that BAM ordered a large stock of IRMM-014 several years ago. That stock of IRMM-014 Fe cubes and IRMM-014 Fe wires will be dissolved in 6M HCl in a large quantity. The new anchor point, the high purity Fe metal, that is commercially available at BAM, is a pure Fe metal with only trace amounts of impurities. The high purity BAM material will also be dissolved in 6M HCl in large quantity. Several aliquots of both solutions will be measured on the Neptune Plus MC-ICP-MS to define this second anchor point with a low uncertainty. Further will we send several aliquots of both solutions to different laboratories to also measure this second anchor point of high purity Fe on the 56/54Fe scale.
We will report the values of that study on BAM high purity Fe and will provide a guide for scale conversion to the IRMM-014 scale and for uncertainty calculation to use that new anchor point instead of the exhausted IRMM-014.
AbstractThe minor and trace element composition of minerals provides critical insights into a variety of geological processes. Multi-element mapping by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is an important technique applied for this purpose and although the method is rapidly advancing, there remains a fundamental compromise between spatial resolution, detection limit, and experiment duration when using sequential mass analyzers. To address the limitation of limited analyte selection for high spatial resolution maps imposed by the sequential nature of typical quadrupole (Q)-ICP-MS, we tested the Aerosol Rapid Introduction System (ARIS) for repeat mapping of the same area. The ARIS is a high-speed transfer tubing system that reduces aerosol washout times, permitting resolution of individual pulses at 40–60 Hz. Here, the ARIS was tested not for pulse resolution but with novel operating conditions optimized to perform fast, high spatial resolution mapping of minor and trace element distribution in pyrite and marcasite. For this purpose, ablation was conducted with a 5 µm beam aperture, a repetition rate of 50 Hz, and a continuous stage scan speed of 40 µm s−1. For each LA-Q-ICP-MS map, data were acquired for six elements with an acquisition time of 20 ms per element. This deliberately reduced the individual pulse resolution of the ARIS but instead exploited the spatial resolution and sensitivity gains afforded by the high-laser repetition rate combined with efficient aerosol transfer. The new method successfully mapped trace elements at single to double-digit parts per million levels, and the maps reveal fine-scale zoning of trace elements with an effective x and y resolution of 5 µm, while white light interferometry showed that for each experiment, only ca. 1 µm of the sample was removed. Repeated mapping of the same area showed excellent correspondence not only between element concentrations in successive experiments but also in the shape, dimension, and location of regions of interest defined by concentration criteria. The very good repeatability of the elemental maps indicates that for studies requiring more analytes, successive mapping of additional elements is possible. By contrast with conventional very small spot (i.e., 5 µm) analysis, fast repetition rate and stage scan speed mapping avoids down-hole fractionation effects and minimizes accidental analysis of buried invisible inclusions. Compared to conventional LA-ICP-MS mapping, the method reduces the experiment time by 4–8 times.