Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
- 2023 (3)
Dokumenttyp
- Zeitschriftenartikel (1)
- Vortrag (1)
- Posterpräsentation (1)
Sprache
- Englisch (3)
Schlagworte
- Ageing (1)
- Early-life overstress (1)
- GD-OES (1)
- Li-ion batteries (1)
- Li-ion battery (1)
- ageing (1)
- battery ageing (1)
- battery aging mechanism (1)
- current collector corrosion (1)
- depth profiles (1)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (3)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (3)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- S Qualitätsinfrastruktur (1)
- S.1 Qualität im Prüfwesen (1)
Eingeladener Vortrag
- nein (1)
In this work, we employed glow discharge optical emission spectrometry (GD-OES) depth profiling as a fast and semi-quantitative method to investigate the aluminum (Al) current collector degradation in commercial lithium cobalt oxide (LCO) pouch cells with no Al2O3 pretreatment. After battery aging, a heterogeneous deposit was found on the surface of the cathode. Gray hotspot areas within an extensive pale white region were formed. Consistent with energy dispersive X-ray (EDX) analysis of micro-cross sections milled via targeted focused ion beam (FIB), an Al-containing layer of approximately 3 µm can be observed using GD-OES. We attribute one main cause of this layer is the degradation of the Al current collector. The nonuniform growth of this layer was investigated by performing GD-OES depth profiling at different in-plane positions. We found that the gray area has a higher mass concentration of Al, probably in metallic form, whereas the white area was probably covered more homogeneously with Al2O3, resulting from the inhomogeneous distribution of the pitting positions on the current collector. Compared to FIB-EDX, GD-OES enables a faster and more convenient depth profile analysis, which allows the more productive characterization of lithium-ion batteries (LIBs), and consequently benefits the development of preferable battery materials.
Deconvoluting the impact of early-life abuse conditions on the degradation of lithium-ion cells
(2023)
The successful repurposing of degraded lithium-ion (Li-ion) batteries in second-life applications is a vital step towards achieving a circular economy. While reusing aged Li-cells is a promising way of mitigating their overall environmental footprint, it is crucial to anticipate their future safety and performance characteristics . Unfortunately, predicting these properties is a cumbersome task, essentially caused by limited knowledge of the interference of different degradation modes in the cells’ first life.
To still enable estimating of these parameters from a current state, the present study systematically investigates the impacts of abusive conditions in an early phase of the cells’ life on their subsequent degradation behavior. For this purpose, individual Li-cells are initially stressed by different measures such as overcharging, deep-discharging, plating, and deliberate combinations of the aforementioned methods. Electrochemical performance indicators are monitored during subsequent cycling of the cells which provides insights into the interdependencies of different degradation modes induced by specific stress conditions. In this manner, it is clarified whether or not the total degradation can be determined by a convolution or a superposition of individual deterioration effects and, thus, be described as a multidimensional state function.
This knowledge will finally contribute to a better understanding of the performance and safety behavior of degraded Li-ion batteries which can help to successfully implement them into second-life applications.
Understanding the safety characteristics of aged Lithiumion
(Li-ion) batteries is essential for their effective
integration into second-life applications. The SafeLiBatt
project is a research initiative focused on evaluating
safety-related parameters of these batteries.
The presented study elucidates the impact of a cells’
state of health (SOH) on its safety behavior. Four highpower
pouch cells (Li-NMC622) were exposed to elevated
temperatures to achieve accelerated ageing. Subsequent
thermal abuse tests were utilized to assess crucial
parameters related to the thermal runaway (TR).
When compared to their non-aged (begin of life, BOL)
analogs, the aged cells implicated a TR-onset lowered by
about 10 – 20 K.