Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (24)
- Vortrag (21)
- Beitrag zu einem Tagungsband (13)
- Beitrag zu einem Sammelband (3)
- Sonstiges (2)
- Posterpräsentation (2)
- Corrigendum (1)
- Forschungsbericht (1)
Schlagworte
- Aktive Thermografie (9)
- Flash thermography (8)
- Thermografie (8)
- NDT (7)
- Thermography (7)
- Zerstörungsfreie Prüfung (7)
- Active thermography (5)
- Concrete (5)
- CFK (4)
- GFRP (4)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (21)
Asphalt is one of the most common materials used in road construction. It is subject to both chemical and structural aging processes during use. At least to our knowledge, it is not currently known whether these aging processes also lead to a measurable change in the thermal properties of asphalt. If so, these changes could be exploited for non-destructive testing of the aging condition in situ. Photothermal analysis of a component surface involves looking at the time course of the surface temperature during and after pulse-like heating with an expanded laser beam. In the case of concrete surfaces, this method works well under laboratory conditions. It allowed the determination of the thermal effusivity. Now it should be investigated whether the photothermal signal allows conclusions to be made regarding the aging state of the asphalt. Within the scope of this paper, 2 asphalt specimens were investigated: a closed asphalt with 3% void content (SMA 11S) and an open-pore asphalt with 25% void content (PA 8). Both samples were artificially degraded according to a standardized procedure, leaving a portion of the surface unaffected. Subsections from both areas were then separated for photothermal testing. It was found, that the photothermal method is apparently not sensitive enough to detect aging on asphalt in general. However, it is noteworthy that both asphalt types heat up significantly faster than would be expected from the theory of heat conduction, which might be explained by the specific microstructure.
Up to now, the inspection of wind turbines with industrial climbers has been considered ”state of the art”. However, ever-larger wind turbines and advancing digitization make modern and automated inspection methods indispensable. Passive thermography can serve as such a digital and atomized method while it is well known for its applications in the inspection of buildings or electrical circuits. However, its application relies on thermal gradients in the inspected object such that a temperature contrast exists between damaged and sound areas. This also holds for unheated structures like rotor blades of wind turbines which show no intrinsic temperature gradient and can hardly be heated. Under certain weather conditions with sufficient solar loading and diurnal temperature variations, passive thermography is suitable for the in-service inspection of rotor blades. However, for a reliable use of passive thermography on ”thermal passive” components, the incorporation of these environmental conditions in the planning and evaluation of thermal inspections is crucial. Additionally, the complex inner structure of wind turbine blades in comparison to other objects and buildings require a specific method referencing the individual rotor blades to each other. This allows the distinction between the thermal response of design-specific structural features and damages or irregularities between the three blades. We show thermal signatures of damage in rotor blades and contrast them with structural characteristics by comparing the three blades. In addition to measurements in industrial environments, laboratory measurements are shown and compared to simulations. The long-term goal is to simulate the influence of different weather parameters and thus gain a better understanding of measurements in the field. The results shown here can be seen as one step towards industrial application.
The evaluation of thermal properties is probably an underrated tool for the onsite health monitoring of concrete structures. The photothermal approach offers a possibility to realize a real onsite measurement. This contribution presents the application of the photothermal approach under lab conditions on three different concrete types. The obtained results were compared with those of a commercial device based on the Transient Plane Source (TPS) method. Both agreed well within the estimated uncertainty ranges and therefore demonstrate the applicability of the photothermal method for this kind of investigations. First results of a concrete sample with different water contents support the potential of this method for the characterization of concrete in general.
Evaluation of passive Thermography for the inspection of wind turbine blades. Comparison of passive thermography from the ground with drone-supported images and active thermography. Better understand the influence of weather conditions through field measurements. Development of an inspection planning tool that incorporates weather forecasts. Use FEM simulations to predict thermal contrasts of different damages under different environmental conditions.
A semi-automatic thermographic procedure for the assessment of the welded area of resistance projection welded joints has been developed. Currently, to assess the quality of RPW joints destructive tests are used and the more commonly used non-destructive technique is the ultrasonic one. The possibility for a quantitative evaluation of the welded area by thermographic technique has been proved by means of an innovative procedure applied on steel RPW joints with ‘as it’ surface conditions. Measurements obtained by thermography and ultrasound have been compared, to verify the developed procedure.
Die Thermografie beruht auf der bildlichen Darstellung von Temperaturunterschieden oder auch thermischen Kontrasten an der Oberfläche eines Untersuchungsobjektes. Diese bilden sich nur her-aus, wenn sich das Untersuchungsobjekt gerade erwärmt oder abkühlt. Der Beitrag erklärt mittels eines stark vereinfachten Modells die Entstehung solcher Kontraste als dynamischen Effekt ver-schiedener Abkühlgeschwindigkeiten. Neben Laborergebnissen werden beispielhaft einige Ergeb-nisse von einem mittelalterlichen Baudenkmal präsentiert, um das Verständnis für die thermografi-sche Inspektion von Fassaden zu vertiefen.
The knowledge about energy release and transient behaviour of flash lamps, used as short-term energy source in flash thermography investigations, is essential for a quantitative analysis of the results as well as for simulations regarding such experiments. Usually, only a rectangular pulse shape of a typical duration of a few milliseconds is regarded when flash lamps pulses are described. This note considers the afterglow period of a flash lamp explicitly and shows that negligence of this afterglow effect leads to a systematic underestimation of the pulse length and the related total energy release. In the reported case, the intensity transient recorded by a Silicon photo diode was transformed into a temperature transient, allowing the study of the real energy release. It turns out that approximately only 50% of the entire pulse energy were released during the usually regarded period of 2.8 ms, while the other half was released within a period of 20 ms with an exponential decay.
In vielen Umgebungen, besonders bei hohen Temperaturen, korrosiven Umgebungen oder auf bewegten oder schlecht zugänglichen Flächen, kann die Temperatur nicht oder nur mit nicht akzeptablem Aufwand mit Berührungsthermometern gemessen werden. Diese Umgebungsbedingungen sind unter anderem in der chemischen Industrie, der Lebensmittel-, Metall-, Glas-, Kunststoff- und Papierherstellung sowie bei der Lacktrocknung anzutreffen. In diesen Bereichen kommen Strahlungsthermometer zum Einsatz. Der VDI-Statusreport zeigt typische Anwendungsfelder von nicht radiometrisch kalibrierten Wärmebildkameras und von radiometrisch kalibrierten Thermografiekameras. Um verlässlich mit spezifizierten Messunsicherheiten berührungslos Temperaturen zu messen, müssen die Strahlungsthermometer und Thermografiekameras nicht nur kalibriert, sondern radiometrisch und strahlungsthermometrisch umfassend charakterisiert werden. Auch die optische Materialeigenschaft, der spektrale Emissionsgrad und die Gesamtstrahlungsbilanz (Strahlung des Messobjekts und der Umgebung) sind bei der industriellen Temperaturmessung von großer Bedeutung. In den letzten Jahrzehnten ist dazu ein umfassendes technisches Regelwerk entstanden, das wir Ihnen mit diesem VDI-Statusreport vorstellen. Manche in den Richtlinien beschriebenen Kennwerte mögen abstrakt wirken. In diesem Statusreport zeigen wir an konkreten Beispielen, was diese Kenngrößen für die berührungslose Temperaturmessung bedeuten. Beispiele von Anwendungen zeigen, wo temperaturmessende Thermografiekameras und ausschließlich bildgebende Wärmebildkameras in der Praxis eingesetzt werden. Mit einer Analyse, welche Themen und Anwendungen derzeit besonders intensiv diskutiert werden, versuchen wir Trends für zukünftige Entwicklungen herauszuarbeiten.