Due to their increasing energy density, lithium-ion-batteries (LIBs) play a key role in the traffic energy transition. Regarding their safety behavior, the main challenge of LIB-cells remains the thermal runaway (TR) process. In situ/operando investigations of the TR on commercial cells is possible with radiographic and computer tomographic measurements. Nonetheless, high resolution visualization of the TR persists as a challenge due to the high progression speed of the TR-process itself. Generally, performing abuse tests at cryogenic temperatures allows to slow down or even prevent the TR. Nevertheless, not all abuse methods are suitable for TR investigations at low temperatures. Nail penetration is an appropriate option, however, contains numerous unknown parameters and therefore suffers regarding reproducibility.
Herein, a self-developed high precision nail-penetration-setup is introduced, approaching the necessary mechanically reproducibility with controlled temperatures down to -190°C. The setup allows the preparation of critically abused, however, at cryogenic temperatures stable LIB-cells. These cells were controlled rethermalized to room temperature during synchrotron x-ray computer tomography (SXCT) with a pixel size up to 0.7 μm. During this measurement, the temperature and voltage of the cell is monitored allowing the visualization of the initial internal cell reactions. This study reveals the relation between internal reactions and cell voltage. Finally, the developed set-up enables in-depth analysis of thermal runaway behavior down to material level for various commercial battery cells in the future.
Lithium batteries are the key technology for the successful implementation of the energy transition. Nevertheless, the consequences of thermal runaway of lithium batteries pose the greatest safety risk. In particular, the transport of damaged lithium batteries poses special challenges in order to minimize the effects of thermal runaway. By developing a precision nail test rig, the positive effects of cooling damaged lithium batteries can be investigated and safe transport temperatures identified.
Im Zusammenhang mit den Untersuchungen zu den Möglichkeiten von gekühlten Transporten von Lithiumbatterien werden unterschiedliche Zerstörungsmethoden vorgestellt und diskutiert. Insbesondere wird dabei das neu entwickelte Nageltool und die vorläufigen Untersuchungen für den Einfluss von Ultratiefkühlung auf unbeschädigte Lithiumbatterien vorgestellt.