Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (23)
- Beitrag zu einem Tagungsband (15)
- Zeitschriftenartikel (8)
- Posterpräsentation (4)
- Buchkapitel (3)
- Sonstiges (3)
- Forschungsbericht (3)
- Handbuch (1)
Schlagworte
- Zerstörungsfreie Prüfung (17)
- Brücken (10)
- NDT (9)
- Beton (6)
- Bridge (6)
- Concrete (6)
- Non-destructive testing (6)
- Validation (6)
- Digitalisierung (5)
- Nachrechnungsrichtlinie (5)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (44)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (44)
- 7 Bauwerkssicherheit (2)
- 7.6 Korrosion und Korrosionsschutz (2)
- 6 Materialchemie (1)
- 6.3 Strukturanalytik (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
- 9 Komponentensicherheit (1)
- 9.5 Tribologie und Verschleißschutz (1)
- VP Vizepräsident (1)
Eingeladener Vortrag
- nein (23)
Im deutschen Eisenbahnnetz sind ca. 80 Millionen Spannbetonschwellen verbaut. Analog zu anderen Bauwerken werden Wpannbetonschwellen regelmäßig visuell inspiziert. Die Rissbildung ist bei diesen Inspektionen ein Kriterium für die Schädigung einer Spannbetonschwelle. Durch Rissbildung kann es passieren, dass Betonschwellen ihre Nutzungsdauer nicht erreichen.
In der aktuellen Projektphase liegt der Fokus auf der Datenaufnahme, -bearbeitung und -speiche-rung mit dem Ziel, automatisierte Auswerteverfahren einsetzen zu können. Aktuell wurden primär punktuelle Messungen an ausgewählten Messtagen aufgenommen. Die Systeme sollen so weiter-entwickelt werden, dass sie sich auch für kontinuierliche Messungen im Rahmen von Monitoring-aufgaben eignen.
Ein wichtiger Fokus bei der Auswertung ist die Kombination mit numerischen Modellen, die mithilfe von Bayesian Update Verfahren und den aufgenommenen Messdaten kalibriert und im Verlauf der Monitoringaufgabe angepasst werden sollen. Insbesondere sollen auch zeitabhängige Modelle, die eine zeitliche Entwicklung von Struktureigenschaften beinhalten (Kriechen, Schwinden, Ermüdung, Korrosion) dazu verwendet werden, die zukünftige Performance der Struktur bewerten zu können. Basierend darauf werden dann Konzepte zur Planung von Inspektion und Wartung erstellt.
Post-tensioning systems provide safe and efficient construction solutions for long span bridges. Despite the improved grouting practices over the past decade, existing post-tensioning systems may have significant amount of grout defects, which could lead to corrosion of the strands. Condition assessment of post-tensioning systems is necessary to allow bridge owners to take timely, proactive actions to mitigate or prevent further Deterioration and unanticipated tendon failures. A detailed experimental study conducted to assess the performance of nondestructive evaluation techniques in detecting grout defects within internal tendons is presented herein.
Nondestructive evaluation techniques that include Ground Penetrating Radar, Impact Echo, Ultrasonic Tomography, and Ultrasonic Echo are evaluated in terms of detecting the location and severity of fabricated grout defects in a full-scale post-tensioned U-girder mock-up specimen. While Ground Penetrating Radar can identify the location and profile of the internal tendons, particularly metal ducts due to strong reflections, this method did not provide any information about the defect conditions within the tendon. Both Impact Echo and Ultrasonic Echo techniques are effective in identifying the Location of grout defects, but could not differentiate between water, void, or compromised grout conditions. The study clearly demonstrates the need for NDE techniques that are applicable to anchorage regions, and that are capable of estimating the severity and nature of grout defects in internal tendons.
Zerstörungsfreie Prüfverfahren (ZfPBau-Verfahren) sind auch im Bauwesen stets an praxisrelevante Prüfaufgaben gekoppelt. Die Ermittlung beispielsweise eines Ist-Zustandes im Vorfeld einer Betoninstandsetzung oder die Ermittlung von Schadensursache und Schadensumfang als Folge wiederkehrender Untersuchungen von Brücken nach DIN 1076 sind etablierte Anwendungsgebiete der ZfPBau. Mit der Einführung der Nachrechnungsrichtlinie für Straßenbrücken im Jahr 2011 hat die Nachfrage nach ZfPBau-Dienstleistungen einerseits stark zugenommen, andererseits eröffnet sie Möglichkeiten, in statischen Nachweisen die tatsächlichen Eigenschaften bestehender Konstruktionen rechnerisch anzusetzen. Dazu aber müssen Messergebnisse statistisch bewertet werden können. Dies geschieht durch eine einheitliche Ermittlung der Messunsicherheit, mit der die Voraussetzungen geschaffen werden, um Messergebnisse von ZfPBau-Verfahren in statischen Berechnungen verwenden zu können. Im folgenden Beitrag wird gezeigt, wie Messgrößen der ZfPBau als (stochastische) Basisvariablen in probabilistische Nachweise zur Berechnung der Zuverlässigkeit einfließen können, indem Grenzzustandsgleichungen modifiziert werden. Mit dieser Vorgehensweise sind weitere Schlussfolgerungen aus den Ergebnissen möglich.
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications.
To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
The majority of ultrasonic devices used for non-destructive testing in civil engineering require contact with the surface of the concrete (specimen), which significantly increases the time required for the measurement. This makes it impractical for extensive investigation of large-scale structures such as bridge decks, foundations, or tunnels.
In a pioneering approach, fluidic oscillators are used as contact free ultrasonic sources to overcome the aforementioned limitations. These robust and cost-effective actuators require only pressurised air and are ideally suited for harsh environments. At a constant supply pressure, they generate a continuous mono-frequent actuation signal. Further, varying the supply pressure via a fast pressure regulator was found to generate a frequency modulated signal which enabled time-of-flight measurement with an added advantage of increased signal to noise ratio. To demonstrate the feasibility of this novel idea of non-contact ultrasound, the results of the initial tests are presented.
Mit zunehmenden Alter und wachsenden Verkehr treten vermehrt Verschleißerscheinungen an Brückenbauwerken auf. Um in der Zukunft dem weiter steigendem Straßenverkehr gewachsen zu sein, muss besonders der Zustand der Bestandsbrücken vor 1985 erfasst und beurteilt werden.
Im Rahmen der Nachrechnungsrichtlinie von Straßenbrücken können genauere Kenntnisse über das Eigengewicht eines Brückenbauwerks dazu genutzt werden, um den entsprechenden Teilsicherheitsbeiwert auf der Einwirkungsseite der statischen Berechnung abzusenken und dadurch die Realität genauer abzubilden. Mit Hilfe des Ultraschallechoverfahrens wurden die Bauteildicken an einem Brückensegment der Spandauer-Damm-Brücke auf dem TTS der BAM ermittelt und zur Berechnung des Eigengewichtes weiter verwendet. Zeitgleich wurde dabei untersucht, wie dicht das Messraster gewählt werden muss, damit bei einem möglichst geringen Messaufwand dennoch zuverlässig Bauteildicken abgeschätzt werden können. Auf Grundlage der ausgewerteten Messdaten wurde für die verschiedenen Messpunktabstände die jeweilige Masse des Bauteils berechnet. Zur Überprüfung der Genauigkeit der Ergebnisse wurde das Brückensegment als Ganzes gewogen. Des Weiteren wurden die ermittelten Bauteildicken und Massen des Brückensegmentes nach der Methode des GUMs (Guide to the Expression of uncertainty in measurement) statistisch bewertet.
Die Ergebnisse zeigen, das Bauteildicken bis auf 96 % genau mit dem Ultraschallechoverfahren ermittelt werden können. Dabei offenbarte die statistische Auswertung, dass das Eigengewicht von der Rohdichte des Betons und den mit Ultraschallechoverfahren ermittelten Bauteildicken maßgebend beeinflusst werden. Daher sollte einer genaueren Bestimmung der Rohdichte zur Abschätzung des Eigengewichts nach der vorgestellten Methode besondere Aufmerksamkeit geschenkt werden.
Die Masterarbeit (Titel s.o.) entstand im Sommersemester 2015 an der HTW Berlin in Kooperation mit der BAM und ist in der Bibliothek der HTW Berlin verfügbar.
Corrosion of concrete reinforcement is one of the major damage mechanisms affecting both the load-bearing capacity and the serviceability of re-inforced concrete structures significantly. When externally discernible damages are observed during visual inspections on the structure, the extent of the damage inside the concrete is often already significant. Corrosion caused by carbonation often leads to severe discoloration of the surface or even large-area spalling of the concrete cover. In contrast, chloride-induced corrosion is usually difficult to observe visually but can cause much more serious damage in less time. The effect occurs locally and can lead to weakening of the cross-section of the reinforce-ment. This, in turn, can cause sudden structural collapses without prior notice.
In the meanwhile, various non-destructive and minimally invasive testing methods are available to evaluate the resistance to penetration of corrosion-pro-moting pollutants and to detect active corrosion. In this paper, a bridge crossing the river Regen is used as a case-study to demonstrate how the information ob-tained applying different testing methods can be combined and evaluated in the context of structural reassessments. Both the results of the permeability testing and the electrical resistance measurement are considered, as well as active corro-sion areas are localized using the half-cell potential mapping combined with the concrete cover measurement with the eddy current method and ground penetrat-ing radar. The results are evaluated using drill cores and in addition laser-induced breakdown spectroscopy was applied to obtain information about possible chlo-ride ion transport into the concrete.