- Digital detector array (DDA) (3)
- Betatron (2)
- NDT (2)
- Radiography (2)
- X-ray backscatter imaging (2)
- Aerospace applications (1)
- Casting (1)
- Comparison of detectors (1)
- Computed tomography (1)
- Conservation of wooden artwork (1)
A comparative study on the performance of digital detector systems for high energy applications
(2014)
For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements.
The objects of this investigation were sculptures taken from a ca. three hundred years old baroque epitaph of a church in Tonning, a town in Northern Germany. Around 1900 it was found in a disastrous state heavily damaged by wood-worm. At that time, the whole artwork was treated with the tar extract carbolineum as a remedy. Nowadays, this substance has been identified as carcinogenic, and its presence can be perceived by its stench and visually at certain spots on the surface where it has penetrated the covering paint.
A gold-painted sculpture of a massive wooden skull was interrogated with X-rays and fast neutrons to investigate the internal distribution of the carbolineum. The X-ray tomography, with its excellent spatial resolution revealed galleries left over from the worm infestation in the outer areas and cracks in the central region. The golden color coating appeared as a thick and dense layer. In comparison the tomography with fast neutrons, though being of lower resolution and yet unresolved artefacts revealed sections of slightly different densities in the bulk of the wood. These differences we attribute to the differences in the distribution of the impregnant in the wood, visible due to its higher hydrogen content making it less transparent for neutrons.
Innovative X-ray backscatter technique for security applications: Detection of dangerous materials
(2014)
Radiological inspections, in general, are NDT&E methods to detect the bulk of explosives without invasion into the object of analysis. In contrast to personal luggage, cargo or structural components constitute a complexity that may significantly hamper the detection of a threat by conventional transmission radiography. A novel approach of interrogating a large object to a certain depth only with a single sided access will be presented. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattered objects. The new X-ray backscatter camera is not only imaging the objects due to their densities but also by taking into account the influences of surrounding objects. Additionally, it does not only image illuminated features but also depicts shadows from absorbing materials. This is a unique characteristic of the developed X-ray backscatter camera. Experimental mock-ups are conducted imitating container with threats among a complex packing as they may be encountered in reality. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security will be discussed.
In this contribution, we present a dual high-energy X-ray imaging technique for cargo container inspection using the 'spectral high-energy X-ray attenuation method'. This method is based on attenuation of continuous highenergy spectra. The developed experimental technique consists of a betatron as high-energy (up to 7.5 MeV) X-ray source and a matrix detector with high spatial resolution (400 ìm) for digital X-ray imaging. In order to evaluate the material discrimination capability using dual high-energy X-ray imaging, a test specimen is proposed, comprising step wedges of different low and high atomic number (Z) materials. The selected X-ray spectra for the dual-energy experiments correspond to 3 MV and 7.5 MV acceleration potential of the betatron. We evaluated the ratio between low- and high-energy X-ray attenuation coefficients quantitatively based on simulated poly-energetic high-energy X-ray source spectra and the detector sensitivity using the 'analytical Radiographic Testing inspection simulation tool' (aRTist) developed at BAM. The simulated effective attenuation coefficients are compared with corresponding experimental results in order to establish a method for identification of low- and high-Z materials in the container. Finally, important applications of the proposed technique in the context of aviation security are discussed.
Critical parts in aircraft manufacturing such as stringers are very commonly used in modern aircraft structures to resist the compressive loads caused by the aerodynamic effects. They are generally made-up of thin aluminium (Al) metal sheets and are one of the key components in the aircraft wings. Any defects in the stringer leads to weakening of the stiffness of the whole wing structure and consequently, failures may occur. Hence, the structural integrity of the stringers should be evaluated using reliable non-destructive testing (NDT) methods. Due to the complex shaped structure of the stringer, the one-sided access NDT method such as X-ray backscatter technique is more preferable for the non-destructive imaging. In this paper, we present a new X-ray backscatter technique to image the internal sections of the stringer with only a single-sided access. The whole object was inspected by changing the viewing direction of the X-ray backscatter camera. For the first time, the X-ray backscatter measurements were conducted using high-energy (> 0.5MeV) X-rays and proved the applicability of the present technique to inspect thick carbon-fiber laminated components. In order to improve the inspection time and image quality of the backscatter image, we used high-resolution (180ìm) digital detector arrays (DDAs). At the end, important applications of the presented X-ray backscatter technique to the aerospace industry are discussed.
Abweichend von der gängigen Vorgehensweise, mit einem Bleistiftstrahl
die Lage eines Bildpunktes festzulegen und die rückgestreute Strahlung großflächig aufzunehmen, bietet die neu entwickelte Kamera Unabhängigkeit von Einstrahl- und Blickrichtung. Ausgestattet mit einer 'Optik' für hochenergetische Strahlung, wie die bereits beschriebene Schlitzblendenkamera, ist die variable Gestaltung von Einstrahl- und Blickrichtung möglich. Damit eröffnet sich die
Chance, Strahlung absorbierende Details in einem Objekt sichtbar werden zu lassen, die sonst von einer streuenden Umgebung überstrahlt würden. Zudem wird gezeigt, wie sich das Erscheinungsbild von Objekten umgebungsbedingt im Rückstreubild ändern kann.
Zur Durchstrahlung großer, dichter Objekte reichen die Energien, die mit normalen Röntgenröhren erzielt werden können, ab gewissen Schichtdicken nicht mehr aus. Als hochenergetische Strahlenquellen stehen Kobalt-60 und Elektronenbeschleuniger zur Verfügung. Als Einschränkung der Hochenergieradiographie ist der geringere Kontrast besonders beim Vorhandensein leichterer Objekte umgeben von Körpern bestehend aus schweren Elementen anzusehen. Es ist daher zu erwarten, dass Objekte aus organischen Substanzen hinter dicken Schwermetallwänden oder in Bohrungen von Metallblöcken schwer zu erkennen sind. Im Gegensatz zu einem Gammastrahler wie Kobalt-60 mit den beiden Spektrallinien um 1,3 MeV besitzt die Bremsstrahlung aus einem Beschleuniger einen wesentlichen Anteil an niederenergetischer Strahlung, der fließend zu höheren Energien übergeht. Es wird hier untersucht, welche Signaturen von leichten Materialien in einer Umgebung aus Schwermetall bis zu welcher Dicke und bis zu welchem Komplexizitätsgrad erkennbar sind. Mit einem Betatron (JME X-ray Betatron 7,5 MeV) und einem Matrixdetektor (Perkin Elmer XRD 1621) wurden Aufnahmen von unterschiedlichen leichten Objekten angefertigt, die zunehmend in eine Umgebung aus Schwermetallen gestellt wurden. Mit unterschiedlichen Energieeinstellungen wurde untersucht, inwieweit eine Materialerkennung hinter welcher Abschirmung möglich ist. Die experimentellen Ergebnisse werden mit Simulationen verglichen, die mit einer Software zur Modellierung von Durchstrahlungsverfahren (aRTist) erzeugt wurden. Dabei wird dem Problem der Aufhärtung bei Anwendung von Bremsstrahlung Rechnung getragen. Die Ergebnisse können sowohl zur Erkennung von Fremdkörpern in Maschinen oder Pumpen als auch zur Überprüfung von Frachtladungen im Bereich der öffentlichen Sicherheit und bei Zollkontrollen dienen.
Die Arbeitsgruppe 5 der Europäischen Föderation für Zerstörungsfreie Prüfung (EFNDT Working Group 5 „Public Security and Safety“, EFNDT WG 5) verfolgt weiterhin das Ziel, organisatorisch weit auseinanderliegende Zuständigkeiten und Arbeitsgebiete zusammenzuführen, die weitgehend mit gleichen, zumindest ähnlichen Prinzipien und Methoden arbeiten.
Auf der Suche nach neuen Wegen stoßen beide Seiten auf Gemeinsamkeiten. Dies gilt auch für neue Ansätze und Bewertungsmethoden von Techniken, mit denen Risiken vermindert werden sollen. Hierzu hat in Berlin ein Workshop im Oktober 2012 stattgefunden, auf dem parallele Projekte zur Container- und Frachtsicherheit zusammengeführt werden konnten. Herausgestellt wurde die Komplementarität der laufenden Projekte, gemeinsame Aspekte sollen künftig auch zusammen bearbeitet werden. Darüber hinaus wurden neue Methoden und Vorgehensweisen vorgestellt, aber auch die Sichtweise der Europäischen Kommission mit ihren Vorstellungen zu einem europäischen Markt für Sicherheitstechnik dargestellt. Angesprochen wurden bestehende und vorgeschlagene europaweite Regulierungen und das europäische Referenznetz zum Schutz kritischer Infrastrukturen (ERNCIP), welches ein Netzwerk von Laboratorien für den Test von Sicherheitstechnik zum Ziel hat. Auf technischem Sektor standen Methoden im Vordergrund, mit denen die Gesamtmenge eines Gefahrstoffes wie z.B. Sprengstoff erkannt werden können, und nicht nur Spuren als indirektem Hinweis. Die Arbeitsgruppe konnte somit erstmalig ein neutrales Forum für parallel laufende Projekte zur öffentlichen Sicherheit zur Verfügung stellen. Die auf den Workshops 2010 bis 2012 in Berlin gehaltenen Vorträge sind auf der EFNDT WG 5 – Webseite im geschützten Bereich zu finden.
Nicht alles davon ist geeignet, es der allgemeinen Öffentlichkeit zugänglich zu machen. Deshalb sind alle Vorträge aus den Workshops in einem passwortgeschützten Verzeichnis abgelegt. Die Erteilung des Passwortes erfolgt über den Convenor der Arbeitsgruppe durch die EFNDT. Eine Erweiterung dieser Struktur zu einem Austauschforum ist vorgeschlagen. Zur Teilnahme daran sind nicht nur Mitglieder in den Gesellschaften für zerstörungsfreien Prüfung eingeladen, sondern auch diejenigen, die in den Anwendungsgebieten zur öffentlichen Sicherheit tätig sind.