Eigenverlag BAM
Filtern
Dokumenttyp
Schlagworte
- Dosimetry (2)
- Element-specific spectroscopy (2)
- Geant4 (2)
- High-entropy alloys (2)
- MCS (2)
- Magnetism (2)
- Microdosimetry (2)
- Monte-Carlo simulation (2)
- Particle scattering (2)
- Reverse Monte Carlo (RMC) (2)
- TOPAS (2)
- TOPAS-nBio (2)
- Antiadhesive surfaces (1)
- Artificial neural network modelling (1)
- AuNP (1)
- Bacteria-repellent surfaces (1)
- Bacterial adhesion tests (1)
- Berliner Tuffsteinfassaden (1)
- Betondickglasfenster des Glockenturms am Eiermannbau (1)
- Biofilms (1)
- Cancer therapy (1)
- Cell (1)
- Cribellate spiders (1)
- Croyo-starage (1)
- Data fusion (1)
- Duplex stainless steels (1)
- Exchange interaction (1)
- Extended X-ray absorption fine structure (EXAFS) (1)
- Extended X-ray absorption fine structure (EXAFS), (1)
- Ferromagnetism (1)
- Formaldehyde (1)
- G5P (1)
- GV5 (1)
- Geant4-DNA (1)
- Gold (1)
- Gold mit Synchrotronstrahlung (1)
- High-pressure volumetric analyzer (HPVA) (1)
- Hydrogen Fuelling Stations (1)
- Hydrogen Storage (1)
- Hydrogen assisted cracking (1)
- Kaiser-Wilhelm-Gedächtniskirche (1)
- Kandelaber des Ensembles am Charlottenburger Tor (1)
- LLG (1)
- Landau Lifshitz equation (1)
- Laser-induced periodic surface structures (LIPSS) (1)
- Magnetic moment (1)
- Magnetic nanoparticles (1)
- Metal-organic frameworks (MOFs) (1)
- Micorscopic dose-damage relation (1)
- Micromagnetism (1)
- Microplastic (1)
- Mitochondria (1)
- Molecular VOx catalysts (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Nucleus (1)
- OOMMF (1)
- Object oriented micromagnetic framework (1)
- PET (1)
- Pergamonmuseums (1)
- Phonons (1)
- Protein (1)
- Proteins (1)
- Radiation therapy (1)
- Radiografische Untersuchung (1)
- Reference material (1)
- Reversible Hydrogen Storage (1)
- SAXS (1)
- Schriftrollen vom Toten Meer (1)
- Selective oxidation (1)
- Simulation (1)
- Stochastic Landau Lifshitz Gilbert equation (1)
- Targeted nanoparticle (1)
- Temperature (1)
- Temperature scaling (1)
- Thermal conductivity (1)
- Thetaevolve (1)
- Time-of-Flight secondary ion mass spectrometry (1)
- X-ray absorption near edge structure (XANES) (1)
- X-ray magnetic circular dichroism (XMCD), (1)
Organisationseinheit der BAM
- 6 Materialchemie (13) (entfernen)
For almost 150 years it is known that hydrogen has a deleterious effect on the mechanical properties of metallic components. Nowadays, the problem of hydrogen assisted degradation is highly relevant in energy related fields due to the massive use of steel as a structural component in these applications and its sensitivity to hydrogen. Since the discovery of hydrogen assisted cracking (HAC), researchers studied intensively and suggested possible explanations and mechanisms in order to define how hydrogen is affecting the material. In general, it is considered that hydrogen changes the mechanical properties more in terms of ductility (deformation capacities) than in strength (load capacities). Hydrogen concentration is one of three crucial factors in the degradation process, together with the microstructure of the material and the internal/external mechanical load. The relatively high concentration of hydrogen resulting in this loss of ductility can originate during production or before service (e.g. welding processes) and during service (i.e. catholically protected systems to eliminate corrosion processes in sour environments).
In parallel to the theoretical work, tremendous efforts were, and are still, invested in searching for a proper method to elucidate, map and quantify the hydrogen in the microstructure, which is the basis for this work. For steels, the focus is mainly on the observations of diffusion processes and the interaction of hydrogen with the microstructure
in regions with high local stresses/strains (for example around evolving cracks). The challenge for reaching this goal arises from the fact that accurate indication of hydrogen by means of position, unlike heavier atoms, can be made only by mass spectrometry or by interaction with another element (e.g. silver decoration, special coating and resonant nuclear reaction by nitrogen). In addition to this, the difficulty recording the hydrogen behavior while it rapidly diffuses through the material, leaving only the unpredicted failure, should be taken into account.
Although using powerful characterization methods, models and computational simulations, the key to defining the mechanisms behind HAC is still under debate and not fully understood. The relationship between material and hydrogen is determined by three factors, i.e., the material structure and microstructure – determining the physical properties, the mechanical load applied on the material and the hydrogen concentration. It is well known that in order to have a complete definition of HAC these three factors must be examined locally with the minimal scale and the maximal resolution reachable. The major gap is the lack in such a characterization method or a technique by which one has the ability to detect and observe the hydrogen in the metallic microstructure. The commonly used techniques nowadays are capable of characterization of the microstructure without the ability to observe the hydrogen distribution. Global hydrogen concentration and localized hydrogen observation are possible by some techniques which are incapable of indicating a change in the structure or microstructure therefore a comprehensive overview can be gained only by combining several methods.
In the presented research, secondary ion mass spectrometry (SIMS) was adopted as the main tool to detect and locally map the hydrogen distribution in two types of duplex stainless steel grades: EN 1.4462 (standard 2205 duplex stainless steel) and EN 1.4162 (2101 lean duplex stainless steel). The term duplex stainless steel (DSS) refers to the austenitic-ferritic microstructure of the steel where the combination of physical and mechanical properties of the two phases is achieved. The DSS was selected as a case study for this work due to the wide use of this grade in many energy and the lack of knowledge on hydrogen behavior in two-phase containing microstructures. ToFSIMS was exploited in-situ and ex-situ in three experimental approaches during or following
an electrochemical charging procedure. This type of hydrogen charging was selected as it simulated a procedure of cathodic protection of most sub-water oil and gas extraction and delivery systems. The experimental procedures were:
1. Ex-situ charging followed by ToF-SIMS imaging for basic understanding of hydrogen distribution.
2. Ex-situ charging followed by in-situ mechanical loading to obtain information on hydrogen behavior around a propagating crack.
3. In-situ permeation of hydrogen through a steel membrane inside the ToF-SIMS to obtain information on diffusion behavior of hydrogen in a two-phase microstructure.
The comprehensive view of the effect of hydrogen on steel was gained by using supplementary methods, such as high resolution scanning electron microscopy (HR-SEM), focused ion beam (FIB) and electron back-scattered diffraction (EBSD). The state of the art in this work lies in applying both: in-situ experimental approaches and data treatment of the ToF-SIMS raw data. The data treatment includes the combination of data from several sources (data fusion).
The results for the ex-situ charging followed by static sample imaging and data fusion showed that when the analyzed surface is directly exposed to the electrolyte the degradation is pronounced differently in the ferrite, austenite and interface. The degradation mechanisms in the ferrite and austenite were reflected by the formation of cracks on the surface of both, where a high concentration of hydrogen was obtained. This result supports the assumption that hydrogen is attracted to highly deformed regions. The advantage of using in-situ charging/permeation in comparison to ex-situ charging is that the effect of hydrogen on the ferrite and austenite phases when the hydrogen is evolving from within the microstructure is realized, in comparison to when the analyzed surface is initially exposed directly to the electrolyte. In both experiments the ferrite was observed as a fast diffusion path for the hydrogen. The faster diffusion of hydrogen through the ferrite is expected due to the higher diffusion coefficient, however, a direct proof for the diffusion sequence in this scale was never shown. Most significant results were achieved by the ‘core’ experiments of this research. These experiments included the design of a novel dynamic mechanical loading device to apply an external load during SIMS imaging of a hydrogen precharged-notched sample. For the first time it was shown that plastic deformation induced by applying a mechanical load is resulting in a redistribution of hydrogen locally around the notch.
The huge atomic heterogeneity of high-entropy materials along with a possibility to unravel the behavior of individual components at the atomic scale suggests a great promise in designing new compositionally complex systems with the desired multi-functionality. Herein, we apply multi-edge X-ray absorption spectroscopy (extended X-ray absorption fine structure (EXAFS), X-ray absorption near edge structure (XANES), and X-ray magnetic circular dichroism (XMCD)) to probe the structural, electronic, and magnetic properties of all individual constituents in the single-phase face-centered cubic (fcc)-structured nanocrystalline thin film of Cr20Mn26Fe18Co19Ni17 (at.%) high-entropy alloy on the local scale. The local crystallographic ordering and component-dependent lattice displacements were explored within the reverse Monte Carlo approach applied to EXAFS spectra collected at the K absorption edges of several constituents at room temperature. A homogeneous short-range fcc atomic environment around the absorbers of each type with very similar statistically averaged interatomic distances (2.54–2.55 Å) to their nearest-neighbors and enlarged structural relaxations of Cr atoms were revealed. XANES and XMCD spectra collected at the L2,3 absorption edges of all principal components at low temperature from the oxidized and in situ cleaned surfaces were used to probe the oxidation states, the changes in the electronic structure, and magnetic behavior of all constituents at the surface and in the sub-surface volume of the film. The spin and orbital magnetic moments of Fe, Co, and Ni components were quantitatively evaluated. The presence of magnetic phase transitions and the co-existence of different magnetic phases were uncovered by conventional magnetometry in a broad temperature range.
The superior properties of high-entropy multi-functional materials are strongly connected with their atomic heterogeneity through many different local atomic interactions. The detailed element-specific studies on a local scale can provide insight into the primary arrangements of atoms in multicomponent systems and benefit to unravel the role of individual components in certain macroscopic properties of complex compounds. Herein, multi-edge X-ray absorption spectroscopy combined with reverse Monte Carlo simulations was used to explore a homogeneity of the local crystallographic ordering and specific structure relaxations of each constituent in the equiatomic single-phase facecentered cubic CrMnFeCoNi high-entropy alloy at room temperature. Within the considered fitting approach, all five elements of the alloy were found to be distributed at the nodes of the fcc lattice without any signatures of the additional phases at the atomic scale and exhibit very close statistically averaged interatomic distances (2.54 – 2.55 Å) with their nearest-neighbors. Enlarged structural displacements were found solely for Cr atoms. The macroscopic magnetic properties probed by conventional magnetometry demonstrate no opening of the hysteresis loops at 5 K and illustrate a complex character of the long-range magnetic order after field-assisted cooling in ± 5 T. The observed magnetic behavior is assigned to effects related to structural relaxations of Cr. Besides, the advantages and limitations of the reverse Monte Carlo approach to studies of multicomponent systems like high-entropy alloys are highlighted.
This 6 minute long MP4-video presents some key results of the European research project "BioCombs4Nanofibers" to the broader public. Inspired by nature, some concepts of certain types of spiders are transferred to technology in order to develop bacteria-repellent surfaces through laser surface nanostructuring.
Funding notice: This study was funded by the European Union's research and innovation program under the FET Open grant agreement No. 862016 (BioCombs4Nanofibers, http://biocombs4nanofibers.eu).
Gas adsorption is based on physical properties between gases and solid materials, enriching the surface with packed gas molecules with a higher density than in the bulk phase. For using this mechanism as a gas storage strategy, highly porous materials are necessary since large surfaces in small volumes can provide the storage system with a higher density than the gas phase. In the case of hydrogen gas, the interaction forces with solid surfaces are generally low at room temperature but can increase considerably at low operating temperatures. As a counterpart, the storage pressure is considerably lower than that necessary by traditional gas compression.
Amongst ultra-porous adsorbent materials for hydrogen cryoadsorption, metal-organic frameworks (MOFs) are a group of remarkable solids made from metallic nodes linked by organic molecules exhibiting a wide variety of composition, geometry, porous properties, and chemical functionality. The scientific community focused in the last years on enhancing both the specific area of materials and the interaction energy to extend the storage properties of cryoadsorption to ambient-temperature and use it as hydrogen storage mechanisms in vehicles. However, the found difficulty in achieving ultra-porous structures with high-enough interaction energies decreased this research interest in the last years.
However, for a stationary application like hydrogen refueling stations, where space and weight are not such limits as in vehicles, cryoadsorption can still be considered a feasible candidate for hydrogen storage. Cryoadsorption is the only fast and fully reversible approach to store hydrogen at similar density values as compressed gas. Cryogenic operation is a technological challenge, but first, liquid nitrogen is cheap, and second, it is less energy-demanding than hydrogen liquefaction, which is indeed considered as feasible for transportation and storage. Cryoadsorption involves lower pressure
than compressed gas, increasing safety in the storage facilities, but additional research on the construction materials properties is necessary to better understand their behavior in contact with hydrogen at cryogenic temperatures. However, the knowledge of all these mechanisms is important to identify the improvement opportunities based on, probably, the interphase between different solutions.
To achieve the set project goals, this internal research report describes the work packages realised within the framework of the project.
The present study investigates the possibility of improving the selective oxidation of methane to formaldehyde over V-SBA-15 catalysts in two different ways. In a classical approach of catalyst optimization, the in situ synthesis of V-SBA-15 catalysts was optimized with regard to the applied pH value. Among the set of catalysts synthesized, a higher amount of incorporated vanadium, a higher content of polymeric VOx species as well as a less ordered structure of the support material were observed by increasing the pH values from 2.0 to 3.0. An optimum in performance during the selective oxidation of methane to formaldehyde with respect to activity and selectivity was found over V-SBA-15 prepared at a pH value of 2.5. With this knowledge, we have now evaluated the possibilities of reaction control using this catalyst. Specifically, artificial neural network modelling was applied after the collection of 232 training samples for obtaining insight into the influence of different reaction parameters (temperature; gas hourly space velocity (GHSV); and concentration of O2, N2 and H2O) onto methane conversion and selectivity towards formaldehyde.
This optimization of reaction conditions resulted in an outstanding high space-time yield of 13.6 kgCH2O∙kgcat∙h−1
Models for TOPAS/Geant4 to estimate the microscopic dose received by biomolecules during bioSAXS experiments.
The C++ classes in this repository extend the functionality of the TOPAS (http://www.topasmc.org/) Monte-Carlo program, which is itself a wrapper of the Geant4 MCS Toolkit (http://geant4.org).
These files contain cell models for TOPAS/Geant4 and the inclusion of nano particles in particle scattering simulations. A simple spherical cell with nanoparticles can be generated in a fast manner. The user has the option to include the following organelles: nucleus, mitochondria, cell membrane. Additionally nanoparticles can be included in the cytosol and at the surface of the nucleus and/or the mitochondria.
The C++ classes in this repository extend the functionality of the TOPAS (http://www.topasmc.org/) Monte-Carlo program, which is itself a wrapper of the Geant4 MCS Toolkit (http://geant4.org). The sourcecode together with examples and scorers are provided.
"If you use this extension please cite the following literature:
Hahn, M.B., Zutta Villate, J.M. "Combined cell and nanoparticle models for TOPAS to study radiation dose enhancement in cell organelles." Sci Rep 11, 6721 (2021).
https://doi.org/10.1038/s41598-021-85964-2 "
To simulate the movement of the macroscopic magnetic moment in ferromagnetic systems under the influence of elevated temperatures, the stochastic version of the Landau-Lifshitz (LL) or the Landau-Lifshitz-Gilbert equation with a spin density of one per unit cell has to be used.
To apply the stochastic LL to micromagnetic simulations, where the spin density per unit cell is generally higher, a conversion has to be performed. OOMMF sample files MIF) are provided which can be used to determine the Curie temperature for the classical bulk magnets, iron, nickel and cobalt.