7.6 Korrosion und Korrosionsschutz
Filtern
Erscheinungsjahr
- 2019 (123) (entfernen)
Dokumenttyp
- Vortrag (73)
- Zeitschriftenartikel (16)
- Sonstiges (16)
- Beitrag zu einem Tagungsband (15)
- Forschungsbericht (3)
Sprache
- Deutsch (64)
- Englisch (57)
- Mehrsprachig (2)
Schlagworte
- Korrosion (43)
- Corrosion (32)
- Nichtrostender Stahl (11)
- Carbon steel (9)
- Deckschichtbildung (8)
- Gelartige Elektrolyte (7)
- Korrosionsschutz (7)
- KorroPad (6)
- Korrosionsprüfung (6)
- CCS (5)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (123)
- 7.6 Korrosion und Korrosionsschutz (123)
- 5 Werkstofftechnik (15)
- 5.1 Mikrostruktur Design und Degradation (14)
- 3 Gefahrgutumschließungen; Energiespeicher (8)
- 3.2 Gefahrguttanks und Unfallmechanik (8)
- 7.4 Baustofftechnologie (4)
- 8 Zerstörungsfreie Prüfung (3)
- 8.0 Abteilungsleitung und andere (2)
- 5.3 Polymere Verbundwerkstoffe (1)
- 7.2 Ingenieurbau (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 9 Komponentensicherheit (1)
- 9.3 Schweißtechnische Fertigungsverfahren (1)
Eingeladener Vortrag
- nein (73)
Since materials play an important role when designing and servicing industrial facilities. Also, for energy systems there is no way around. Selection of appropriate materials is an essential aspect for successful application and reliable service life. Future engineers must be made aware on the importance of this fact. So, they may prevail in techno‐economic discussions.
The book fulfills its intension of providing to students in science and engineering a comprehensive understanding of different energy processes and what role materials play in this conjunction. Also, it gives interested engineers and scientists an insight in this matter. After being introduced the user should dig deeper in the existing detailed knowledge available for materials selection within these special conditions to assure a reliable operation of the energy production facility.
Specific amounts of oxidizing and reductive impurities as well as some moisture were added to dense phase CO2 to replicate CO2 streams from sources in a CCS pipeline network. Due to the moisture content being only 50 ppmV no visible acid condensation took place. To simulate stress conditions at the inside pipeline surface due to fluid pressure (10 MPa) specimens were preloaded using a load frame. Experiments conducted at 278 K and at 313 K revealed the highest corrosion rate at lower temperature. Corrosive effect of impurities was strongest applying mixed atmosphere, containing oxidizing and reductive components, closely followed by CO2 streams with pure oxidizing character. By far, the lowest corrosion rate (10x lower) resulted from reductive atmosphere. In general, at constant temperature and pressure the CO2 stream composition strongly influences the morphology, thickness and composition of the corrosion products. Applying oxidizing or mixed impurities, iron hydroxides or oxides (e.g. goethite, hematite) occur as dominating corrosion products, capable to incorporate different amounts of sulfur. In contrast, using reductive atmosphere very thin corrosion layers with low crystallinity were developed, and phase identification by XRD was unfeasible. SEM/EDX analysis revealed the formation of Fe-O compounds, most likely attributed to the oxygen partial pressure in the system induced by CO2 (≥0.985 volume fraction) and volatile H2O. In addition to the surface covering corrosion layer, secondary phases had grown locally distributed on top of the layer. These compounds are characteristic for the applied atmosphere and vary in number, shape and chemical composition.
Für Anwender nichtrostender Stähle wird im neu überarbeiteten Merkbaltt 833 eine Planungshilfe für Anwendungen nichtrostender Stähle in Erdböden gegeben. Hinweise und Empfehlungen zur Werkstoffauswahl sowie allgemeine Hinweise zum Einsatz nichtrostender Stähle und auch Anwendungsbeispiele sind im neu überarbeitetn Merkblatt enthalten.
Ein neuer Ansatz bei elektrochemischen Korrosionsuntersuchungen kann durch den Einsatz von gelartigen Elektrolyten als Alternative zu wässrigen Prüfelektrolyten beschritten werden. Gelartige Elektrolyte ermöglichen minimalinvasive Untersuchungen an natürlich gebildeten Zinkdeckschichten. Dadurch können korrosionsrelevante Kennwerte ermittelt werden, die Aussagen zur Deckschichtbildung und zur Stabilität von atmosphärisch gebildeten Deckschichten erlauben. In diesem Beitrag wird anhand verschiedener Untersuchungen an Reinzink der Mehrwert von gelartigen Elektrolyten für die Korrosionsforschung und -prüfung verdeutlicht. Darüber hinaus werden neue Erkenntnisse zur Deckschichtbildung von Zink unter atmosphärischen Bedingungen vorgestellt.
Ein neuer Ansatz bei elektrochemischen Korrosionsuntersuchungen kann durch den Einsatz von gelartigen Elektrolyten als Alternative zu wässrigen Prüfelektrolyten beschritten werden. Gelartige Elektrolyte ermöglichen minimalinvasive Untersuchungen an natürlich gebildeten Zinkdeckschichten. Dadurch können korrosionsrelevante Kennwerte ermittelt werden, die Aussagen zur Deckschichtbildung und zur Stabilität von atmosphärisch gebildeten Deckschichten erlauben. In diesem Beitrag wird anhand verschiedener Untersuchungen an Reinzink der Mehrwert von gelartigen Elektrolyten für die Korrosionsforschung und -prüfung verdeutlicht. Darüber hinaus werden neue Erkenntnisse zur Deckschichtbildung von Zink unter atmosphärischen Bedingungen vorgestellt.
Der Vortrag verdeutlicht am Beispiel von Offshore-Windenergieanlagen, welchen Beitrag ein geeigneter Korrosionsschutz zu Fragen der Wirtschaftlichkeit, der Gesundheitstechnik und der Sicherheit leistet. Die Umweltverträglichkeit von Korrosionsschutzmaßnahmen wird anhand der Emission von chemischen Substanzen und Verbindungen beleuchtet.
In der aktuellen RL-SIB wie auch im Gelbdruck der Instandhaltungsrichtlinie ist bei Anwendung des Instandsetzungsprinzips W-Cl bzw. Verfahren 8.3 der Erfolg der Maßnahme durch Einbau und Messung von Korrosionsstrom-Mess-Einrichtungen nachzuweisen. Auch wird bei der Instandsetzung von chloridbelasteten Rissen bei Stahlbetonbauteilen durch Verpressen der Risse bzw. Aufbringen einer Rissbandage ein Korrosionsmonitoring empfohlen. Anerkannte Regelwerke oder Normen über Art und Aufbau des Monitoring-Systems sowie Kriterien zur Bewertung der Messergebnisse im Hinblick auf den Erfolg der Instandsetzungsmaßnahme gibt es derzeit nicht. Auch sind keine Untersuchungen zur Qualität der Messergebnisse veröffentlicht.
Ziel des Vorhabens ist die Ausarbeitung eines Regelwerks-Entwurfes für die Art und den Aufbau von Korrosionsmonitoring-Systemen sowie für Kriterien zur zuverlässigen Bewertung der Messergebnisse, mit denen der Erfolg bei verschiedenen Instandsetzungskonzepten überprüft werden kann.
Das Verhalten von Erdböden gegenüber metallenen Konstruktionswerkstoffen ähnelt in vielen Fällen der von neutralen Wässern. Der in natürlichen Erdböden vorhandene Wasseranteil bildet mit den löslichen Inhaltsstoffen eine Elektrolytlösung. Eine merkbare Korrosionsgeschwindigkeit tritt erst dann auf, wenn der Boden einen bestimmten Wassergehalt aufweist, der eine Sauerstoffdiffusion im Boden zur Oberfläche des Metalls gewährleistet. Von maßgebendem Einfluss auf die korrosionsverursachende Wirkung der Böden ist neben dem Feuchtegehalt, der die Leitfähigkeit des Bodens bestimmt, der pH-Wert. Verschiedene Bodenarten besitzen unterschiedliche Wasser- und Sauerstoffdurchlässigkeiten, sowie Unterschiede der gelösten Inhaltsstoffe wie Chloride oder Sulfate, wodurch sich das Korrosionsverhalten von Metallen in verschiedenen Böden stark unterscheidet. In der DIN 50929-3 werden Böden in vier verschiedene Bodenklassen mit Korrosionsbelastungen von sehr niedrig bis hoch unterteilt. Durch verschiedene Bodenanalysen und örtliche Gegebenheiten kann nach DIN 50929-3 zwar die Korrosivität eines Bodens bestimmt werden, jedoch ist die Reproduzierbarkeit eines Bodens (Prüfmediums) praktisch nicht möglich.
Es gibt jedoch Überlegungen, wie die Einstellung einer Bodenklasse durch Verwendung von Normsand und der Zugabe von Stoffen erzielt werden kann, wodurch die Reproduzierbarkeit eines Bodens ermöglicht wird.
Messing unter Druck
(2019)
Dictionary of Metallurgy and Metal Processing - English-German – German-English (Book review)
(2019)
The first issue of this classic dictionary contains highly specialized terms, not only of the area of metallurgy but also of welding, soldering and corrosion. Special attention was paid by the author to a correct reference of each term according to the field of application.
Finally, this book fulfills the intension of its author, to collect relevant terms with the correct pendant from a huge variety of sources and applications. It provides the user a foundation for correct terminology and communication for international contacts.
Biodiesel is subject to degradation processes like oil and grease. The oxidative degradation products of vegetable oil esters in biodiesel particularly lead to enhanced sedimentation in blended fuels.
The polarity of biodiesel increases its solvency and facilitates permeation and extraction. Solvation, swelling and/or extraction lead to changes in the physical properties and chemical changes of polymeric materials. It also accelerates the degradation (hydrolysis and oxidation) of these materials with the loss of additives and stabilizers.
The objective of this research was to determine the resistance of frequently used polymeric materials such as ACM, EPDM, FKM, FVMQ, CR, CSM, IIR, HNBR, NBR, PA, PE; POM, PUR, PVC and VMQ in biodiesel and heating oil with 10 %/20 % biodiesel (B10/B20) at 40°C and 70°C.
Mass, tensile strength and breaking elongation of the test specimens were determined before and after the exposure for 84 days in the biodiesel heating oil blends. The visual examination of some elastomer test specimens clearly showed the great volume increase until break or partial dissolution. Shore hardness A and D were determined before and after exposure of the test specimens in the biofuels for 42 days.
The elastomers CR, CSM, EPDM, IIR, NBR and VMQ were generally not resistant to biodiesel and B10 at 40°C and 70°C. FKM, ACM, HNBR, PA, PE, POM, and PVC showed high compatibility in B10/B20 at 40°C. A lower compatibility was determined for ACM in biodiesel. ACM and HNBR were not resistant in B20 at 70°C.
Effizienz und Qualität sind schon immer Antriebsmotoren für die Wirtschaft. Um das heutzutage in einer stetig schneller agierenden Welt zu erreichen, wird konsequentes Prozessmanagement immer wichtiger. Dabei werden Prozesse nicht nur klar und eindeutig beschrieben, sondern auch Kompetenzen, Aufgaben und Verantwortlichkeiten festgelegt, um das Resultat für den Kunden in den Fokus zu rücken und zeitraubende Hierarchiekämpfe zu vermeiden.
Der Autor untermalt die gut strukturierten Textpassagen, in denen wichtige Schlagworte fett abgedruckt sind, mit vielen Schaubildern zu Prozessen und übersichtlichen Tabellen. Er gibt dem Leser Werkzeuge in Form von Checklisten sowie Diagnoseplänen und Analyseformularen.
Gleichzeitig wird durch beispielhaft ausgefüllte Formulare (Checklisten) der Praxisbezug anhand unterschiedlicher Branchenbereiche wie z.B. Controlling, Produktion, Medizin, etc. hergestellt. Somit liegt hier ein Arbeitsbuch vor für jeden, der gleich losstarten möchte.
This contribution provides current findings regarding materials susceptibility for carbon capture, utilization and storage (CCUS) applications. Basing on results gathered in 2 German long-term projects (COORAL and CLUSTER) suitable materials are introduced as well as dominating impurities of the CO2-stream and corrosion mechanisms. Investigations cover the whole CCUS process chain and provide material recommendations for certain parts.
This contribution provides current findings regarding materials susceptibility for carbon capture, utilization and storage (CCUS) applications. Basing on results gathered in 2 German long-term projects (COORAL and CLUSTER) suitable materials are introduced as well as dominating impurities of the CO2-stream and corrosion mechanisms. Investigations cover the whole CCUS process chain and provide material recommendations for certain parts.
Susceptibility of 304 stainless steel to crevice corrosion in electrochemically active fluids
(2019)
The susceptibility of AISI 304 stainless steel to crevice corrosion on the effect of contact with electrochemically active fluids was investigated using exposure and stepwise potentiostatic polarisation. Crevice materials made up of 304 SS and Polyether ether ketone (PEEK) forming two kinds of crevices including 304 SS-to-PEEK and 304 SS-to-304 SS were tested.
Susceptibility of 304 stainless steel to crevice corrosion in electrochemically active fluids
(2019)
The susceptibility of AISI 304 stainless steel to crevice corrosion on the effect of contact with electrochemically active fluids was investigated using exposure and stepwise potentiostatic polarisation. Crevice materials made up of 304 SS and Polyether ether ketone (PEEK) forming two kinds of crevices including 304 SS-to-PEEK and 304 SS-to-304 SS were tested.
Susceptibility of 304 stainless steel to crevice corrosion in electrochemically active fluids
(2019)
The susceptibility of AISI 304 stainless steel to crevice corrosion on the effect of contact with electrochemically active fluids was investigated using exposure and stepwise potentiostatic polarisation. Crevice materials made up of 304 SS and Polyether ether ketone (PEEK) forming two kinds of crevices including 304 SS-to-PEEK and 304 SS-to-304 SS were tested.
Ziel des Projektes ist die Qualifizierung von Duplexstählen in Tunnelbauwerken um die Einsatzmöglichkeiten alternativer nichtrostender Stähle zu den bislang gebräuchlichen rostfreien Edelstählen 1.4404 und 1.4571 zu eruieren. Da Duplexstähle im Vergleich zu austenitischen Stählen über eine doppelt so hohe Festigkeit verfügen, können Bauteile schlanker konstruiert werden, wodurch Material eingespart werden kann. Neben der Wirtschaftlichkeit muss die Dauerhaftigkeit untersucht werden. Dazu wurden speziell konzipierte Wand- und Deckenracks mit unterschiedlichen metallenen Werkstoffen und Oberflächen hergestellt und in den Tunnelbauwerken montiert. Nach bestimmten Auslagerungszeiten von bis zu drei Jahren werden die Proben demontiert und auf ihr Korrosionsverhalten untersucht. Ein weiteres Ziel neben der Qualifizierung der Werkstoffgruppe sind die Reduktion der Instandsetzungs- und Wartungsmaßnahmen der Tunnelbetreiber
Aus Rapsöl gewonnener Biodiesel ist eine umweltfreundliche Alternative zu fossilen Energiequellen. In der Europäischen Union, in der 80 % der ölhaltigen Brennstoffe importiert werden müssen, besteht zudem ein Interesse, die Abhängigkeit von exter-nen Ölversorgern zu reduzieren.
Bei jeder Veränderung der Zusammensetzung eines Brennstoffs muss auch die Ma-terialverträglichkeit gewährleistet bleiben. Es stellt sich die Frage, ob Elastomere im Vergleich zu reinem Heizöl auch in Heizöl mit 20 % Biodiesel (B20) beständig sind.
Die Polarität des Biodiesels erhöht die Quellung und fördert die Permeation und Ex-traktion. Sowohl Quellung als auch Extraktion bedingen Änderungen der physikali-schen Eigenschaften der Elastomere. Extraktion verändert die chemische des Heiz-öls. Diese chemischen Veränderungen können auch den Abbau (Hydrolyse und Oxi-dation) der Polymere durch das Herauslösen von Additiven und Stabilisatoren be-schleunigen.
Ziel dieser Arbeit war die Bestimmung der Beständigkeit der Elastomere ACM (Poly-acrylatkautschuk), HNBR (Hydrierter Acrylnitrilbutadienkautschuk), FKM (Fluorkaut-schuk) und PUR (Polyurethan) in Heizöl und im Heizölgemisch B20.
Prüfkörper der Elastomere wurden für 42 Tage (Härteprüfung) und 84 Tage (Zugprü-fung) bei 40 °C ausgelagert. Anschließend wurde die Änderung der Masse, Shore Härte A, Zugfestigkeit, und Reißdehnung bezogen auf die Werte vor der Aus-lagerung bestimmt. Die weniger zur Quellung neigenden Elastomere FKM und HNBR wurden zusätzlich bei 70 °C ausgelagert.
Um die Elastomere im verpressten Zustand zu testen, wurde der Druckverformungs-rest nach DIN ISO 815 bestimmt. Hierzu wurden zylindrische Prüfkörper aus ACM, HNBR und FKM verpresst und in Heizöl und Heizöl mit 20 % FAME für 3, 7, 14, 28, 56 und 90 Tage bei 40 °C ausgelagert. Anschließend wurde über die Dickenmes-sung der Druckverformungsrest ermittelt. Zum Vergleich wurden Prüfkörper verpresst und ohne Medium bei 40 °C ausgelagert.
In den internationalen Normen wurde kein Grenzwert für die Veränderung der Zugei-genschaften und der Härte für eine positive Bewertung der Beständigkeit festgelegt. Deshalb wurde in der BAM ein Grenzwert von 15 % für die Beständigkeitsbewertung herangezogen.
Bei 40 °C lag die Änderung der Zugeigenschaften und der Shore Härte von ACM, HNBR und FKM in Heizöl und in B20 unter 15 %. Folglich sind ACM, HNBR und FKM bei 40 °C in Heizöl und in B20 beständig. PUR ist bei 40 °C in Heizöl beständig, je-doch nicht für eine Verwendung in B20 geeignet, da sich die Zugfestigkeit und Reiß-dehnung um 50 % vermindert haben.
Bei 70 °C ist FKM in Heizöl und B20 beständig, wohingegen HNBR an seine Einsatz-grenzen gelangt und unbeständig ist, in B20 haben sich die Zugfestigkeit um 40 % und die Reißdehnung um 50 % reduziert.
In Europe biodiesel gained from rapeseeds are considered as an alternative to common fossil fuels due to its environmental performance and its independence from import of raw materials. Biodiesel is also suitable to serve as blending component to heating oil. In that case, it must be considered that changes of fuel composition might cause material degradation.
The objective of this research was to investigate the resistance of metallic materials exposed to heating oil, heating oil blend B20 with 20 % biodiesel and pure biodiesel. Furthermore, the resistance of metals to eight-year aged B10 and six-year aged pure biodiesel was evaluated. Ageing of biodiesel forms acids and water which might propagate metal corrosion. The investigated metals (aluminium, unalloyed steel, austenitic CrNi-steel, copper, die cast zinc and brass) are commonly used for components in middle distillate facilities.
According to DIN 50905-4 the immersed metals were exposed in a climate chamber at 50°C for 4 weeks. The metallic materials were evaluated as resistant if the annual corrosion rate due to uniform corrosion remained under 0.1 mm/year and no localized corrosion in the form of pitting occurred.
The corrosion rates of the exposed materials stayed far below the limit of 0.1 mm/year for all tested fuels. An exception was die cast zinc ZP0410 in eight-year aged B10; a corrosion rate up to 0.3 mm/year due to uniform corrosion was measured. In no case localized corrosion occurred. Copper and brass caused discolouration of biodiesel from yellow to green.
In conclusion, the tested metallic materials were resistant in heating oil, heating oil blend B20 and pure biodiesel at 50 °C. Even the metals exposed to six-year aged biodiesel and eight-year aged B10 showed no uniform or localized corrosion; except for zinc, which was not resistant in eight-year aged B10.
Zinc materials are of high importance in the field of corrosion protection. For example, almost half of the annual production of zinc is used as anti-corrosive layer for steel components, particularly under atmospheric conditions. The corrosion protection is frequently ascribed to zinc carbonate species with low solubility which form on the metal surface under atmospheric conditions. Due to the technological importance and wide use of zinc materials, its corrosion behavior and the formation of reaction products has been intensively investigated over decades.
Assuming atmospheric corrosion conditions, an initial native passive film of few nanometers thickness forms spontaneously. It consists of zinc oxide and hydroxide, transforming into various species in dependence of the surrounding atmospheric conditions.
This study focusses on the investigation of corrosion product layers on massive titanium-zinc sheets, formed during short- and mid-term exposure experiments by Fourier-transformed infrared spectroscopy. This method enables the investigation of extremely thin native passive films which form during the initial hours of exposure. Furthermore, aged surface layers are analyzed which were formed by transformation of initial passive layers over the time of several weeks. The spectroscopic investigations are complemented by scanning electron microscopy (SEM/EDX) in order to obtain information on the chemical composition and morphology of the corrosion products. The combination of both methods offers a comprehensive view on the processes occurring in the early stages of zinc corrosion.
Carbon Capture and Storage (CCS) is identified as an excellent technology to reach the target of CO2 reduction. However, the safety issue and cost-effectiveness hinder the future of CCS. For the reliability and safety issues of injection wells, the corrosion resistance of the materials used needs to be determined.
In this study, representative low-cost materials including carbon steel 1.8977 and low alloyed steel 1.7225 were investigated in simulated pore water at 333 K and under CO2 saturation condition to represent the worst-case scenario: CO2 diffusion and aquifer fluid penetration. These simulated pore waters were made from relevant cement powder to mimic the realistic casing-cement interface. Electrochemical studies were carried out using the pore water made of cement powder dissolved in water in comparison with those dissolved in synthetic aquifer fluid, to reveal the effect of cement as well as formation water on the steel performance. Two commercially available types of cement were investigated: Dyckerhoff Variodur® and Wollastonite. Variodur® is a cement containing high performance binder with ultra-fine blast furnace slag which can be used to produce high acid resistance concrete. On the other hand, Wollastonite is an emerging natural material mainly made of CaSiO3 which can be hardened by converting to CaCO3 during CO2 injection.
The results showed the pH-reducing effect of CO2 on the simulated pore water/aquifer (from more than 10 to less than 5) leading to the active corrosion process that happened on both 1.8977 and 1.7225. Electrochemical characterization showed negative free corrosion potential and polarisation curves without passive behaviors. The tested coupons suffered from pitting corrosion, which was confirmed by surface analysis. Interestingly, basing on the pit depth measurements from the tested coupons and the hardness of cement powder, it is suggested that Variodur® performed better than Wollastonite in both aspects. The electrochemical data was compared to that resulted from exposure tests to give a recommendation on material selection for bore-hole construction.
Der Einsatz von Edelstahl Rostfrei in Böden wird nur in wenigen Regelwerken behandelt, somit müssen sich Anwender und mPlaner auf Erfahruzngen und Studien stützen um Hilfestellung zum Beispiel zur Werkstoffauswahl zu erhalten. Der Vortrag stellt das von der BAM und der ISEr überarbeiteet Merkblatt 833 vor, welches den Einsatz von Edelstahl Rostfrei im Erdboden bahandelt.
Carbon Capture and Storage (CCS) is identified as an excellent technology to reach the target of CO2 reduction. However, the safety issue and cost-effectiveness hinder the future of CCS. For the reliability and safety issues of injection wells, the corrosion resistance of the materials used needs to be determined.
In this study, representative low-cost materials including carbon steel 1.8977 and low alloyed steel 1.7225 were investigated in simulated pore water at 333 K and under CO2 saturation condition to represent the worst-case scenario: CO2 diffusion and aquifer fluid penetration. These simulated pore waters were made from relevant cement powder to mimic the realistic casing-cement interface. Electrochemical studies were carried out using the pore water made of cement powder dissolved in water in comparison with those dissolved in synthetic aquifer fluid, to reveal the effect of cement as well as formation water on the steel performance. Two commercially available types of cement were investigated: Dyckerhoff Variodur® and Wollastonite. Variodur® is a cement containing high performance binder with ultra-fine blast furnace slag which can be used to produce high acid resistance concrete. On the other hand, Wollastonite is an emerging natural material mainly made of CaSiO3 which can be hardened by converting to CaCO3 during CO2 injection.
The results showed the pH-reducing effect of CO2 on the simulated pore water/aquifer (from more than 10 to less than 5) leading to the active corrosion process that happened on both 1.8977 and 1.7225. Electrochemical characterization showed negative free corrosion potential and polarisation curves without passive behaviors. The tested coupons suffered from pitting corrosion, which was confirmed by surface analysis. Interestingly, basing on the pit depth measurements from the tested coupons and the hardness of cement powder, it is suggested that Variodur® performed better than Wollastonite in both aspects. The electrochemical data was compared to that resulted from exposure tests to give a recommendation on material selection for bore-hole construction.
Geothermal energy is one of the most promising energy resources to replace fossil fuel. To extract this energy, hot fluids of various salts and gases are pumped up from a geothermal well having a certain depth and location. Geothermal wells in volcanic regions often contain highly corrosive CO2 and H2S gases that can be corrosive to the geothermal power-plants, which are commonly constructed of different steels, such as carbon steel. This research focuses on the corrosion behaviour of carbon steel exposed to an artificial geothermal fluid containing CO2 gas, using an artificial acidic-saline geothermal brine as found in Sibayak, Indonesia. This medium has a pH of 4 and a chloride content of 1,500 mg/L. Exposure tests were conducted for seven days at 70 °C and 150 °C to simulate the operating temperatures for low and medium enthalpy geothermal sources. Surface morphology and cross-section of the specimens from the above experiments were analysed using scanning electron microscope (SEM) and energy dispersive X-ray (EDX). Electrochemical tests via open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) were performed to understand the corrosion processes of carbon steel in CO2-containing solution both at 70 °C and 150 °C. Localized corrosion was observed to a greater extent at 70 °C due to the less protectiveness of corrosion product layer compared to that at 150 °C, where FeCO3 has a high corrosion resistance. However, a longer exposure test for 28 days revealed the occurrence of localized corrosion with deeper pits compared to the seven-day exposed carbon steel. In addition, corrosion product transformation was observed after 28 days, indicating that more Ca2+ cations incorporate into the FeCO3 structure.
Der Vortrag stellt das WIPANO-Vorhaben GELELEK vor. Zu Beginn wird die Problemstellung und Projektidee kurz erläutert. Anschließend wird ein Überblick über die Projektpartner, Projektziele und Arbeitsschritte gegeben, sowie die ausgewählten Probenbleche vorgestellt. Abschließend wurde noch eine Einladung zur Teilnahme am projektbegleitenden Ausschuss ausgesprochen.
Der Vortrag stellt ein neuartiges Korrosionsprüfverfahren für Zinküberzüge auf Basis gelartiger Elektrolyte vor und führt die Vorteile gegenüber konventionellen Prüfverfahren auf. Basierend auf den Ergebnissen wird die Idee für einen IGF-Projektantrag in Kooperation mit dem Fraunhofer IKTS vorgestellt.
Biodiesel is viewed as a major source of energy. In areas such as the European Union, where 80 % of the oil-based fuel is imported, there is also the desire to reduce dependence on external oil supplies.
Materials compatibility is a major concern whenever the fuel composition is changed. The question arises of whether polymeric materials are resistant to heating oil with 20 % biodiesel (B20) in comparison to pure heating oil.
The polarity of biodiesel increases its solvency and facilitates permeation and extraction. Solvation, swelling and/or extraction lead to changes in the physical properties. Extraction alters the fuel chemistry. These chemical changes could also accelerate the degradation (hydrolysis and oxidation) of the polymeric material with the loss of additives and stabilizers.
The objective of this research was to determine the resistance of frequently used materials for components in middle distillate facilities such as ACM, FKM, HNBR, PA, PE, POM, PUR and PVC in heating oil and heating oil blend B20 for 84 days at 40 °C, and FKM, HNBR, PA, POM, PUR and PVC at 70 °C.
Mass, tensile strength, breaking elongation and Shore hardness A (D) of the test specimens were determined before and after exposure for 84 (42) days in the test fuels under static conditions.
For the investigations under compressed conditions, the mass and the compression set of FKM test specimens were determined before and after exposure for 3, 7, 14, 28, 56 and 90 days in B20 at 40 °C and 70 °C according to ISO 815-1 “Rubber, vul-canized or thermoplastic - determination of compression set – Part 1: At ambient or elevated temperatures”.
There is not determined a threshold for the reduction in tensile properties and Shore hardness in the international standards. Therefore, a threshold of 15 % was determined for the evaluation of the compatibility.
The change of tensile strength and breaking elongation of test specimens made of ACM, FKM, HNBR, PA, PE, POM, PUR and PVC exposed to heating oil and the blend B20 was less than 15 % at 40 °C. A maximum reduction in Shore hardness A of 14 % was determined for ACM at 40 °C and for HNBR of 15 % at 70 °C.
It can be concluded that ACM, FKM, HNBR, PA, PE, POM, PVC and PUR were resistant in B20 at 40°C. FKM, PA, POM and PVC were evaluated as resistant in heat-ing oil and B20 at 70 °C, HNBR and PUR were not resistant in these fuels at 70°C.
Based on the mass increase and compression set values of FKM test specimens it can be stated that FKM is resistant in B20 under compressed conditions at 40 °C and 70 °C.
Zum Schutz vor Korrosionsprozessen werden metallene Werkstoffe in der Automobilindustrie üblicherweise mit komplexen Beschichtungssystemen versehen. Durch eine Beschädigung des Beschichtungssystems kann bei Zutritt von Feuchtigkeit und korrosionsstimulierenden Ionen das Metallsubstrat korrodieren und unter Umständen die Beschichtung im Bereich neben der Verletzung enthaften. Dabei gibt es verschiedene Mechanismen, die zu einer Unterwanderung und Enthaftung der Beschichtung führen können. In jedem Fall wird aber die Dauerhaftigkeit des Korrosionsschutzes negativ beeinflusst und die Lebensdauer des Bauteils herabgesetzt.
Die Industrie versucht deshalb, Beschichtungssysteme zu entwickeln, die dem Vorgang der kathodischen Enthaftung bestmöglich widerstehen können. Einen kritischen Entwicklungs- und Qualifizierungsschritt stellt dabei die geeignete Prüfung auf kathodische Unterwanderung und Enthaftung dar, da eine Prüfung der Beschichtung möglichst schnell und kosteneffizient zu belastbaren Ergebnissen führen soll. Neben den industriell üblichen Salzsprühnebeltests kommen häufig elektrochemische Polarisationstests zur Anwendung. Verschiedene Automobilherstellerhaben verwenden jeweils angepasste Tests, die sich bezüglich der Prüfparameter unterscheiden. Bei allen Testvarianten wird aber versucht, durch Verschärfung der Prüfparameter kurze Prüfzeiträume zu erreichen. Dabei kann es aber dazu kommen, dass die real ablaufenden Mechanismen der Unterwanderung beeinflusst und verändert werden und das Prüfergebnis von Ergebnissen im Feld zum Teil stark abweicht.
Im Vortrag werden mit Blick auf die geltenden Regelwerke und Normen die Unterschiede verschiedener Prüfmethoden zur kathodischen Enthaftung bei organischen Beschichtungen vorgestellt und deren Aussagekraft kritisch betrachtet. Am Beispiel von systematischen Versuchsreihen an einem ausgewählten Kurzzeittest werden die Grenzen einiger Methoden herausgearbeitet und die Anwendbarkeit für Qualitätsprüfungen betrachtet. Durch den Ansatz der statistischen Versuchsplanung wird der Einfluss einzelner Prüfparameter auf die Enthaftung und das Ergebnis des Kurzzeittests gezeigt.
Investigation of the salinization in marine and offshore environment - test methods and challenges
(2019)
Salinization and contamination of metal surfaces by chloride-containing aerosols is of great importance with regard to corrosion phenomena in the maritime sector and in offshore applications. Especially Offshore Wind Turbines are exposed to extreme corrosive conditions due to high chloride concentrations in the atmosphere and the resulting high chloride deposition rates. It is of great importance to evaluate to what extent salinization of the surface influences the corrosion protection of coatings and pitting occurrence on stainless steels under atmospheric conditions to evaluate the durability of metallic building structures in offshore and marine environments. The evaluation of the scientific literature and regulatory guidelines has shown that there are still many open questions regarding the contamination of metal surfaces by chlorides. This contribution will discuss how salinization of metal surfaces is evaluated and monitored according to current standards and guidelines. Future challenges concerning test methods and the application of evaluated salinization values and deposition rates will be discussed.
Rezension: Wörterbuch der Metallurgie und Metallverarbeitung ‐ Englisch‐Deutsch – Deutsch‐Englisch
(2019)
Die erste Auflage dieses klassischen Wörterbuches enthält hochspezialisierte Fachbegriffe nicht nur aus dem Bereich der Metallurgie, sondern auch zum Schweißen, Löten und zur Korrosion. Besonderer Wert wurde vom Autor auf einen korrekten Bezug zum jeweiligen Anwendungsgebiet gelegt.
Letztendlich erfüllt das Wörterbuch das Ansinnen seines Autors,aus der Vielzahl von Quellen und Anwendungsgebieten die relevanten Begriffe mit dem korrekten Pendant zusammenzustellen und bietet dem Nutzer eine Grundlage für korrekte Begrifflichkeit und Kommunikation im internationalen Kontakt.
Das in der 3. Auflage vorliegende Fachbuch wird die praktische Arbeit des Ingenieurs bei der Beurteilung von Verschleißerscheinungen unterstützen. In acht Kapiteln behandeln die Autoren alle interessanten Aspekte zu diesem Thema.
Zielgruppen sind Maschinen-bauingenieure, Techniker und Werkstofftechniker in der Entwicklung, Konstruktion und Instandhaltung. Sie werden für ihre Arbeit im Buch gute Unterstützung und Anregungen für ihre praktische Arbeitfinden.
In this also completely rewritten and reorganized second part of the two‐volume set 45 international experts comprise the current knowledge of conjugated polymers. In addition to part one on properties, processing characterization and morphology, 16 chapters cover perspectives, theory and new materials.
Finally, it can be concluded that this 4th edition of this handbook fulfills, like the first part, its intention, to be the definitive resource on the topic of conducting polymers. This is assured by the updated and added contributions of all authors, which consider the significant developments both in fundamental understanding, progress and applications since publication of the previous edition. So, it can be recommended to everyone, who wants to get a comprehensive overview on conjugated polymers, not just to researchers, advanced students, and industry professionals working in materials science and engineering.
The corrosion of steel in reinforced concrete structures is one of the main threats to their durability. Based on the scientific achievements of the past decades the knowledge about the deterioration mechanisms and possible repair strategies for corrosion induced damages have found their way into practice.
It is common sense, that a detailed assessment of the structure is the foundation for a successful repair measure. In addition to the “traditional” singular on-site-procedures such as measurement of concrete cover, carbonation depth, half-cell potentials and chloride contents the monitoring of corrosion related parameters has gained in importance over the past few years.
The advantages of a corrosion monitoring are obvious. In new buildings, structural elements which cannot be assessed after completion (e.g. tunnel segments), or members with electrically isolating coatings can be monitored by means of integrated sensors providing an insight into the development of crucial parameters such as electrochemical potentials, corrosion currents and the electrical resistivity of the concrete. A less known but very beneficial field of application is the use of corrosion monitoring as an integral part of a repair measure based on principles such as the cathodic protection of steel in concrete (CP) or increasing the electrical resistivity of the concrete (IR). By implementing a corrosion monitoring system, it is possible to survey the time dependent effect of the repair measure on the corrosion process which may lead to a confirmation of successful repair measure or to a modification of the repair strategy.
As the principle of cathodic protection for steel in concrete is a recognized repair measure today, the number of applications increases steadily and thus increasing the relevance for corrosion monitoring. Nevertheless, no standards or guidelines concerning the corrosion monitoring are available in Germany today, making it difficult to implement corrosion monitoring in common practice.
With this in mind an international task group formed to develop the specification B12 “Corrosion Monitoring of Reinforced and Prestressed Concrete Structures” published by the German Society for Non-Destructive Testing, DGZfP, spring 2018.
This paper will present the new specification B12 by highlighting the basic measurement principles and illustrating the potentials of corrosion monitoring for new and existing concrete structures by means of case studies.
This work presents machine learning-inspired data fusion approaches to improve the non-destructive testing of reinforced concrete. The principal effects that are used for data fusion are shown theoretically. Their effectiveness is tested in case studies carried out on largescale concrete specimens with built-in chloride-induced rebar corrosion. The dataset consists of half-cell potential mapping, Wenner resistivity, microwave moisture and ground penetrating radar measurements. Data fusion is based on the logistic Regression algorithm.
It learns an optimal linear decision boundary from multivariate labeled training data, to separate intact and defect areas. The training data are generated in an experiment that simulates the entire life cycle of chloride-exposed concrete building parts. The unique possibility to monitor the deterioration, and targeted corrosion initiation, allows data labeling.
The results exhibit an improved sensitivity of the data fusion with logistic regression compared to the best individual method half-cell potential.
The corrosion of steel in reinforced concrete structures is one of the main threats to their durability. Based on the scientific achievements of the past decades the knowledge about the deterioration mechanisms and possible repair strategies for corrosion induced damages have found their way into practice.
It is common sense, that a detailed assessment of the structure is the foundation for a successful repair measure. In addition to the “traditional” singular on-site-procedures such as measurement of concrete cover, carbonation depth, half-cell potentials and chloride contents the monitoring of corrosion related parameters has gained in importance over the past few years.
The advantages of a corrosion monitoring are obvious. In new buildings, structural elements which cannot be assessed after completion (e.g. tunnel segments), or members with electrically isolating coatings can be monitored by means of integrated sensors providing an insight into the development of crucial parameters such as electrochemical potentials, corrosion currents and the electrical resistivity of the concrete. A less known but very beneficial field of application is the use of corrosion monitoring as an integral part of a repair measure based on principles such as the cathodic protection of steel in concrete (CP) or increasing the electrical resistivity of the concrete (IR). By implementing a corrosion monitoring system, it is possible to survey the time dependent effect of the repair measure on the corrosion process which may lead to a confirmation of successful repair measure or to a modification of the repair strategy.
As the principle of cathodic protection for steel in concrete is a recognized repair measure today, the number of applications increases steadily and thus increasing the relevance for corrosion monitoring. Nevertheless, no standards or guidelines concerning the corrosion monitoring are available in Germany today, making it difficult to implement corrosion monitoring in common practice.
With this in mind an international task group formed to develop the specification B12 “Corrosion Monitoring of Reinforced and Prestressed Concrete Structures” published by the German Society for Non-Destructive Testing, DGZfP, spring 2018.
This paper will present the new specification B12 by highlighting the basic measurement principles and illustrating the potentials of corrosion monitoring for new and existing concrete structures by means of case studies.