7.6 Korrosion und Korrosionsschutz
Filtern
Dokumenttyp
- Vortrag (350)
- Zeitschriftenartikel (78)
- Beitrag zu einem Tagungsband (53)
- Sonstiges (53)
- Posterpräsentation (15)
- Forschungsbericht (11)
- Tagungsband (Herausgeberschaft für den kompletten Band) (3)
- Beitrag zu einem Sammelband (2)
- Dissertation (2)
- Handbuch (2)
Sprache
- Deutsch (325)
- Englisch (241)
- Mehrsprachig (2)
- Französisch (1)
Schlagworte
- Korrosion (240)
- Corrosion (162)
- Nichtrostender Stahl (63)
- KorroPad (49)
- Potentialfeldmessung (44)
- Korrosionsschutz (31)
- Zink (31)
- Korrosionsprüfung (29)
- Deckschichtbildung (28)
- Geothermal (27)
- Stainless steel (25)
- Gelartige Elektrolyte (23)
- Spannungsrisskorrosion (23)
- Atmosphärische Korrosion (22)
- Corrosion testing (20)
- Spannstahl (19)
- Coating (17)
- Passivschicht (17)
- EPR (15)
- Lochkorrosion (15)
- Steel (15)
- CCUS (14)
- Polyaniline (14)
- Corrosion resistance (13)
- Korrosionsschnelltest (13)
- Normung (13)
- Passivität (13)
- Trinkwasser (13)
- Bimetallkorrosion (12)
- CCS (12)
- Copper (12)
- Heat treatment (12)
- Auslagerungsversuche (11)
- Carbon steel (11)
- Crevice corrosion (11)
- Dauerhaftigkeit (10)
- Elektrochemie (10)
- Runoff (10)
- CO2 (9)
- Impurities (9)
- Korrosionsuntersuchungen (9)
- Martensitic steel (9)
- Pitting corrosion (9)
- Wasserstoff (9)
- Concrete (8)
- Gel-type electrolytes (8)
- Hygiene (8)
- Korrosionsbeständigkeit (8)
- Monitoring (8)
- Offshore (8)
- CCU (7)
- Electrochemistry (7)
- Supercritical/dense phase CO2 (7)
- Zinc (7)
- Zinc coatings (7)
- Atmospheric Corrosion (6)
- Betonstahl (6)
- CO2 quality (6)
- Carbon steels (6)
- Drinking water (6)
- Droplet corrosion (6)
- FAME (6)
- Hydrogen (6)
- ISO 15630-3 (6)
- Kupfer (6)
- Lead (6)
- Maritime atmosphere (6)
- Martensitic stainless steels (6)
- Metallene Werkstoffe (6)
- Nichtrostende Stähle (6)
- Salinization (6)
- Schadensanalyse (6)
- Spannbetonbauwerke (6)
- Stahl (6)
- Superaustenite steel (6)
- Tunnel (6)
- Wasserstoffversprödung (6)
- Wärmebehandlung (6)
- Zinkdeckschichten (6)
- Additive Fertigung (5)
- Carbon dioxide (5)
- Civil engineering (5)
- Duplexstahl (5)
- Freibewitterung (5)
- Geothermal energy (5)
- LIBS (5)
- Layer formation (5)
- Magnesium (5)
- Maritime Atmosphäre (5)
- Pipeline network (5)
- Schleifen (5)
- SiO2 (5)
- Spaltkorrosion (5)
- ThermoCalc (5)
- Versalzung (5)
- Werkstoffauswahl (5)
- Werkstoffe (5)
- Zinküberzüge (5)
- Alkali-activated materials (4)
- Aluminium (4)
- Atmospheric corrosion (4)
- Atmosphäre (4)
- Beton (4)
- Biodiesel (4)
- Bridge (4)
- Carbon capture storage (4)
- Coatings (4)
- Corrosion Testing (4)
- Duplex (4)
- ECA (4)
- Geothermie (4)
- Heizöl (4)
- Hygienische Bewertung (4)
- Korrosionsverhalten (4)
- Leaching (4)
- Lean Duplex (4)
- Potential mapping (4)
- REM (4)
- Recommendations (4)
- Ringversuch (4)
- Risikobewertung (4)
- Schweißen (4)
- Schweißnaht (4)
- Steel corrosion (4)
- Tensile properties (4)
- Testing (4)
- WIPANO (4)
- Whole-chain CCS scenario (4)
- Überzüge (4)
- Additive manufacturing (3)
- Carbon capture (3)
- Cathodic delamination (3)
- Corrosion products (3)
- DIN EN ISO 15630-3 (3)
- Deckschichten (3)
- Deckschichtwiderstand (3)
- Disinfection (3)
- Electrochemical impedance spectroscopy (3)
- Erdboden (3)
- Failure analysis (3)
- Gel electrolytes (3)
- Grinding (3)
- Gutachten (3)
- Kathodische Enthaftung (3)
- Korrosionsmonitoring (3)
- Korund (3)
- Kupferazid (3)
- Messing (3)
- Oberfläche (3)
- Organic coatings (3)
- Organische Beschichtungen (3)
- Passive film (3)
- Passivity (3)
- Pitting (3)
- Polymer (3)
- Prestressing Steels (3)
- Prestressing steels (3)
- Protection (3)
- RME (3)
- Schwermetalle (3)
- Sediment (3)
- Sensibilisierung (3)
- Shore hardness (3)
- Stainless Steel (3)
- Stainless steels (3)
- Strahlen (3)
- Stress corrosion cracking (3)
- Surface (3)
- Umlaufkühler (3)
- Utilization (3)
- Verzinkt (3)
- Werkstoffprüfung (3)
- X-ray photoelectron spectroscopy (3)
- nichtrostender Stahl (3)
- Aktiv-Passiv-Element (2)
- Al2O3 (2)
- Alloy 31 (2)
- Altern (2)
- Anlagensicherheit (2)
- Artificial seawater (2)
- Atmosphere (2)
- Austenitic stainless steel (2)
- Bauwesen (2)
- Befeuchtungsdauer (2)
- Belüftungselement (2)
- Beschichtung (2)
- Beständigkeit (2)
- Biobrennstoff (2)
- Brass (2)
- Brücke (2)
- Capture (2)
- Carbon (2)
- Carbonation (2)
- Cathodic protection (2)
- Cement (2)
- Chloridgehalt (2)
- Compatibility (2)
- Compatibility evaluations (2)
- Condensate (2)
- Condensation (2)
- Corrosion prevention (2)
- Corrosion rate (2)
- Corrosion resistant materials (2)
- Corrosivity (2)
- Crevice (2)
- Critical chloride content (2)
- DIN 50929-3 (2)
- Dealloying (2)
- Desinfection (2)
- Drinking (2)
- Duplexstähle (2)
- Durability assessment (2)
- EBSD (2)
- Edelstahl rostfrei (2)
- Electrochemical deposition (2)
- Experimentalvortrag (2)
- Explosion (2)
- FT-IR (2)
- Failure (2)
- Feuerverzinkter Stahl (2)
- Galvanische Anoden (2)
- Gefahrstoff (2)
- Grabenkorrosion (2)
- Hartstoffschichten (2)
- ISO 9223 (2)
- Injection (2)
- Konzentrationselement (2)
- Korrosionswechselprüfung (2)
- Korrosivität (2)
- Korundschleifen (2)
- Laboratory Container (2)
- Legierung (2)
- Legierungen (2)
- Lining (2)
- Luftqualität (2)
- Marine Corrosion (2)
- Martensitischer nichtrostender Stahl (2)
- Materials (2)
- Materialuntersuchung (2)
- Metals (2)
- Nitrieren (2)
- Nitrogen (2)
- Nomenklatur (2)
- Non-destrucive testing (2)
- Nondestructive testing (2)
- Oberflächenanalytik (2)
- Oberflächenbearbeitung (2)
- Offshore-Windenergieanlagen (2)
- PVD (2)
- PVD hard coating (2)
- Permeation measurements (2)
- Permeationsmessung (2)
- Physik (2)
- Pipeline (2)
- Pipelines (2)
- Polyaniniline (2)
- Polymer in fuels (2)
- Potential (2)
- Protective coating (2)
- Qualitätsmanagement (2)
- Qualitätssicherung (2)
- Quenching and partitioning (2)
- Sensoren (2)
- Sibayak (2)
- Silicate (2)
- Silicon dioxide (2)
- Sol-gel coating (2)
- Stahlbeton (2)
- Stainless (2)
- Standardization (2)
- Storage (2)
- Straßentunnel (2)
- Sulfide (2)
- Thermodynamik (2)
- TiN (2)
- Titanium nitride (2)
- Trinkwasser-Installation (2)
- Trinkwasserinstallation (2)
- Tunnelbauwerke (2)
- Utilization, and storage (CCUS) technology (2)
- Verzinkter Betonstahl (2)
- Vorgehensweise (2)
- Water (2)
- Windenergie (2)
- Wirksumme (2)
- corrosion (2)
- gelartige Elektrolyte (2)
- 3D-Metal-Printing (1)
- AAM (1)
- ACM (1)
- Abrasive belt (1)
- Absicherung (1)
- Agar (1)
- Aged heating oil with 10% and 20% biodiesel (1)
- Ageing treatment (1)
- Al-Composite (1)
- Al/SiO2 composite (1)
- Alkali-activation (1)
- Alloys (1)
- Analyse (1)
- Analytical Chemistry (1)
- Anode (1)
- Anticorrosion (1)
- Aquifer fluid (1)
- Arbeit (1)
- Artificial Sea Water (1)
- Atmospheric conditions (1)
- Atmospheric exposure (1)
- Auslagerung (1)
- Auslagerungsversuch (1)
- Batteries (1)
- Behmite (1)
- Beschichtungssysteme (1)
- Beständigkeitsbewertung (1)
- Beständigkeitsbewertungen (1)
- Beständigkeitsuntersuchungen (1)
- Bimetallkorroison (1)
- Binary zinc alloys (1)
- Biofuel (1)
- Biogene Brennstoffe (1)
- Brennstoff (1)
- Brittle fracture (1)
- Böden (1)
- CCUS, supercritical/dense phase CO2, carbon steels, martensitic steel, superaustenite steel, droplet corrosion (1)
- CO2 Corrosion (1)
- CO2 pipeline transport (1)
- CO2-Corrosion (1)
- CO2-Speicherung (1)
- CO2-corrosion (1)
- Carbon steels (1)
- Carbon Capture (1)
- Carbon Capture, Utilization and Storage (CCUS) (1)
- Carbon capture, utilization and storage technology (1)
- Casing (1)
- Cathodic Protection (1)
- Ccrit (1)
- Ceramic (1)
- Chloridbelastete Stahlbetonbauwerke (1)
- Chloride (1)
- Chloride attack (1)
- Chloride extraction (1)
- Chloride induced corrosion (1)
- Chloride‐induced corrosion (1)
- Chloridhaltiger Beton (1)
- Chloridinduzierte Lochkorrosion (1)
- Chromstahl (1)
- Cladding (1)
- CoCrMo (1)
- Concrete Carbonation (1)
- Concrete structures (1)
- Constant Load Test (1)
- Contact angle (1)
- Corrosion Protection (1)
- Corrosion and storage (CCUS) technology (1)
- Corrosion costs (1)
- Corrosion product layer (1)
- Corrosion protecting system (1)
- Corrosion protection (1)
- Corrosivity category (1)
- Corundum grinding (1)
- Coûts de la corrosion (1)
- Critical pitting temperature (1)
- DIN EN ISO 9223 (1)
- Damage cases (1)
- Dangerous good (1)
- Datenfusion (1)
- Degradation (1)
- Dense phase (1)
- Deschichtwiderstand (1)
- Desinfektion (1)
- Desinfektion nichtrostender Stahl (1)
- Disinfectants (1)
- Drawing layers (1)
- Drinking water installations (1)
- Droplet (1)
- Duplex stainless steels (1)
- EIS (1)
- Einflussgrößen (1)
- Einflussparameter (1)
- Eisenoxid (1)
- Elastomer (1)
- Elastomere (1)
- Electrochemical (1)
- Electrochemical characterisation (1)
- Electrochemical methods (1)
- Electrochemical noise (1)
- Electrochemical potentiodynamic reactivation (1)
- Electrochemical potentiokinetic reactivation (1)
- Elektrochemische Korrosion (1)
- Elementanalyse (1)
- Emission (1)
- Energie (1)
- Energy (1)
- Energy systems (1)
- Entzinkung (1)
- Environment (1)
- Environmental Chemistry (1)
- Erdböden (1)
- Erneuerbare Energien (1)
- Experimente (1)
- Exposure (1)
- FKM (1)
- FTIR-ATR Measurements (1)
- Fehlerquellen (1)
- Festigkeit (1)
- Feuerlöscheinrichtungen (1)
- Feuerlöschen (1)
- Feuerverzinken (1)
- Feuerverzinkt (1)
- Field exposure studies (1)
- Flow depth (1)
- Flue gas desulphurisation facilities (1)
- Fluoreszenz (1)
- Formeln (1)
- Free weathering (1)
- Freibewitterungsprüfung (1)
- GGBFS (1)
- Galvanic corrosion (1)
- Galvanische Korrosion (1)
- Galvanized reinforcement (1)
- Galvanized steel (1)
- Gastheorie (1)
- Gefahrgut (1)
- Gel-bound Colorants (1)
- Gelartige Elektolyte (1)
- Gelelektrolyte (1)
- General Chemical Engineering (1)
- Geoenergie (1)
- Geopolymer (1)
- Geopolymere (1)
- Gleichungssysteme (1)
- Green-Death solution (1)
- Grinding processes (1)
- Grooving corrosion (1)
- Ground granulated blast furnace slag (1)
- Growth defects (1)
- HNBR (1)
- HSCC (1)
- HVO (1)
- Half-cell potential (1)
- Heating oil (1)
- Heating oil - biodiesel - blend (1)
- Heating oil with 10% biodiesel (1)
- Heating oil with 20% biodiesel (1)
- Heating oil-Biodiesel-Blend (1)
- Heizöl mit 20 % Biodiesel (1)
- Heizöl mit 20% Biodiesel (B20) (1)
- Heizöl-20% Biodiesel-Blend (1)
- Heizöl-FAME-Blends (1)
- High ductility (1)
- High‐nitrogen steel (1)
- Holz (1)
- Hydrogen charging (1)
- Hydrogen-induced Stress Corrosion Cracking (1)
- Hydrogen-induced stress corrosion cracking (1)
- Hydrogen‐induced stress corrosion cracking (1)
- Hygieische Bewertung (1)
- Hygienic assessment (1)
- ISO 8407 (1)
- Impact assessment (1)
- Impedance spectroscopy (1)
- In-situ ED-XRD (1)
- Indonesien (1)
- Inhibitor (1)
- Instandhaltung (1)
- Instandsetzung (1)
- Interkristalline Korrosion (1)
- Iron–chromium–nickel alloy (1)
- Junge GfKORR (1)
- KKS (1)
- Kaltwasserzirkulation (1)
- Kathodische Korrosionsschutz (1)
- Kathodischer Korrosionsschutz (1)
- Klimawechseltest (1)
- Kobaltlegierung (1)
- Konformität (1)
- Kontaktkorrosion (1)
- Korosi (1)
- Korosionsschutz (1)
- KorroPad Prüfverfahren (1)
- Korrosionsbelastung (1)
- Korrosionselemente (1)
- Korrosionssensoren (1)
- Korrosionsuntersuchung (1)
- Korrosionsuntersuchungen in Böden (1)
- Korrosionsversuche (1)
- Korrosivitätskategorien (1)
- Kritischer (1)
- Labor (1)
- Laborarbeit (1)
- Laboratory experiments (1)
- Lean duplex (1)
- Lean-Duplex (1)
- Legierungselemente (1)
- Leitfaden (1)
- Machine learning (1)
- Magnesium Alloy (1)
- Marine (1)
- Marine atmosphere (1)
- Mariner Bewuchs (1)
- Martensit (1)
- Martensitic steel (1)
- Martensitic stainless steel (1)
- Martensitic steels (1)
- Maschinelles Lernen (1)
- Mass loss (1)
- MatLab (1)
- Material properties (1)
- Materials Chemistry (1)
- Materials behavior (1)
- Materialuntersuchungen (1)
- Mechanical Engineering (1)
- Mechanical properties (1)
- Mechanical strength (1)
- Mechanical testing (1)
- Mechanics of Materials (1)
- Meerwasser (1)
- Messsystemanalyse (1)
- Metallabgabe (1)
- Metallurgie (1)
- Metallurgy (1)
- Metals and Alloys (1)
- Metals hygienic assessment release (1)
- Microstructure (1)
- Mikrobielle Gemeinschaft (1)
- Mikroorganismen (1)
- Mikrostruktur (1)
- Monopile (1)
- Mortar (1)
- Mortel (1)
- Nachbearbeitung (1)
- Nachhaltigkeit (1)
- Nanoparticle (1)
- Nanotubes (1)
- Netzwerkbildung (1)
- Nicht rostender (1)
- Nickellegierung (1)
- Nitrocarburieren (1)
- Norm (1)
- Normen (1)
- Oberflächen (1)
- Offhsore-Windenergieanlagen (1)
- Outokumpu: Stainless steel (1)
- Overland flow (1)
- Oxyfuel (1)
- PREN (1)
- PUR (1)
- Physical vapour deposition (PVD) (1)
- Pinholes (1)
- Plastic (1)
- Polarisation (1)
- Polymere (1)
- Polymere Werkstoffe (1)
- Polymeric materials (1)
- Polymers (1)
- Polymerwerkstoff (1)
- Polymerwerkstoffe (1)
- Pore solution composition (1)
- Potentialbeeinflussung der Kontaktpartner (1)
- Potentialmessung (1)
- Pressverbindung (1)
- Prestressing Steel (1)
- Preventive strategies (1)
- Processing (1)
- Programmierung (1)
- Projektmanagement (1)
- Prozessmanagement (1)
- Rainfall classification (1)
- Rainfall simulator (1)
- Redox potential (1)
- Reinforced concrete (1)
- Reinforcement corrosion (1)
- Reinforcing steel (1)
- Resistance (1)
- Resistance of polymers (1)
- Risse (1)
- SCC (1)
- Saline brine (1)
- Saure und alkalische Baustoffe (1)
- Schadnesanalyse (1)
- Schleifbearbeitung (1)
- Schleifprozesse (1)
- Schneidwaren (1)
- Schnelltest (1)
- Schutzwirkung (1)
- Schweißnahtnachbearbeitung (1)
- Schwermetallabgabe (1)
- Schwimmhallen (1)
- Sea Water (1)
- Sea water (1)
- Semiconductive layer (1)
- Sensitisation (1)
- Shore Hardness (1)
- Shore-Härte (1)
- SiO 2 (1)
- SiO2 Nanoparticle (1)
- Sicherer Betrieb (1)
- Silica (1)
- Simulation (1)
- Soil (1)
- Spannbeton (1)
- Spannstahlprüfung (1)
- Stainless steel (1)
- Standard test samples (1)
- Standardproben (1)
- Steel pipes (1)
- Steel-concrete interface (1)
- Stratégies deprévention (1)
- Stress Corrosion Cracking (1)
- Stress Cracking (1)
- Stress corrosion tests (1)
- Superaustenite steel (1)
- Supercritical/dense phase CO 2 (1)
- Surface conditions (1)
- Surface finish (1)
- Surface treatment (1)
- Surfaces, Coatings and Films (1)
- Survey (1)
- TRIP (1)
- Tafel Plot (1)
- Ternary zinc alloys (1)
- Test Methods (1)
- Test electrolytes (1)
- Test solutions (1)
- Testing methods (1)
- Thermal Gravimetric Analysis (1)
- Thin film (1)
- TiMgN (1)
- Titan (1)
- Transformation induced plasticity (1)
- Trinkwasserinstalltion (1)
- Trinkwassersicherheit (1)
- Trockenschleifen (1)
- Tunnelatmosphöre (1)
- Umgebungseinflüsse (1)
- Umweltverträglichkeit (1)
- Urban flooding (1)
- Verarbeitung (1)
- Verfleckungen (1)
- Verformung (1)
- Vermeidung der Elementbildung (1)
- Verschleiß (1)
- Versprödung (1)
- Vorhaben (1)
- W-Cl (1)
- W-Cl Instandsetzungsprinzip (1)
- Wartung (1)
- Wasserzähler (1)
- Water-bearing (1)
- Werkstoffklassen (1)
- Wetting (1)
- Wind energy (1)
- ZFP (1)
- ZfP (1)
- Zinc and galvanized samples (1)
- Zinc anodes (1)
- Zinküberzug (1)
- Znc (1)
- Zugeigenschaften (1)
- arbon capture (1)
- carbon steel (1)
- condensate (1)
- copper (1)
- electrochemical characterization (1)
- geothermal energy (1)
- hygienische Bewertung (1)
- impurities (1)
- magnesium (1)
- nichtrostende Stähle (1)
- pH Indicator (1)
- pitting corrosion (1)
- steel (1)
- utilization, and storage (CCUS) technology (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (569)
- 7.6 Korrosion und Korrosionsschutz (569)
- 5 Werkstofftechnik (45)
- 5.1 Mikrostruktur Design und Degradation (43)
- 3 Gefahrgutumschließungen; Energiespeicher (15)
- 3.2 Gefahrguttanks und Unfallmechanik (15)
- 8 Zerstörungsfreie Prüfung (14)
- 7.4 Baustofftechnologie (11)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (8)
- 6 Materialchemie (7)
Paper des Monats
- ja (1)
In the late 1980s, a new type of corrosion appeared in drinking water installations where galvanized steel pipes failed forming a deep groove with no corrosion at the other surfaces. The reason was discussed quite fiercely between failure analysts and material suppliers. In the end the discussion lead to the solution: inductive welded pipes of a certain sulphur content were prone to selective corrosion. The history of the arguments is discussed using old communications between Wilhelm Schwenk and Wolfgang Stichel, who later published the results in a paper unfortunately only I german.
Thus the knowledge got lost and new cases based on the same material problems are observed in application of so-called C-Steel piping systems. Failure cases are shown.
The screening of coatings shows that the modification by adding individual pigment was not sufficient to protect carbon steel even during a short-term exposure, indicated by the discoloration after only seven days of exposure.
Electrochemical tests indicated that the coating cathodically protects carbon steel or slows down the corrosion reaction.
A long-term exposure test confirmed that the PANI/SiO2 modified coating successfully protects the carbon steel in the Sibayak artificial geothermal water at 150 °C for 6 months.
Corrosive geothermal brines are a major challenge to geothermal power-plants. For cost reasons, plant designers favorize low alloyed steels, e.g., carbon steel, which are susceptible to uniform and localized corrosion when exposed to geothermal brines having acidic and saline properties. To solve such problem, coatings or inhibitors would be a protective solution as an alternative to the use of high alloyed materials.
This study investigated a coating system consisting of polyaniline/silicon dioxide basing on locally available resources. Protection against corrosion of carbon steel is shown by long-term exposure and electrochemical tests of coated carbon steels, performed in an artificial acidic and saline geothermal brine, comparable to real conditions at a site in Indonesia.
Therefore, an integrated coating system is presented for corrosion protection, combining the electro-chemical functionality of polyaniline and the physical advantages of silica.
The critical chloride content C(crit) is an indicator for the corrosion resistance of reinforcing steels in concrete. In this article, several experimental methods for determining the critical chloride content C(crit) of mild and an alloyed (12% Cr) steel in cementitious materials are compared. The methods used include accelerated polarization tests and tests using more natural (unpolarized) conditions in which chloride ingress occurs by diffusion and capillary uptake. The advantages and disadvantages of the methods are discussed, in particular, with the objective of reaching a compromise between applicability to practice and feasibility in laboratory testing.
This work presents machine learning-inspired data fusion approaches to improve the non-destructive testing of reinforced concrete. The principal effects that are used for data fusion are shown theoretically. Their effectiveness is tested in case studies carried out on largescale concrete specimens with built-in chloride-induced rebar corrosion. The dataset consists of half-cell potential mapping, Wenner resistivity, microwave moisture and ground penetrating radar measurements. Data fusion is based on the logistic Regression algorithm.
It learns an optimal linear decision boundary from multivariate labeled training data, to separate intact and defect areas. The training data are generated in an experiment that simulates the entire life cycle of chloride-exposed concrete building parts. The unique possibility to monitor the deterioration, and targeted corrosion initiation, allows data labeling.
The results exhibit an improved sensitivity of the data fusion with logistic regression compared to the best individual method half-cell potential.
Der Vortrag vermittelt dem betreuenden DIN Normenausschuss NMP 177 einen Gesamtüberblick über das abgeschlossene WIPANO-Vorhaben "Normenentwurf für ein Prüfverfahren zur Bestimmung von Deckschichtwiderständen an Zinküberzügen mittels gelartiger Elektrolyte (GELELEK). Innerhalb des Vorhabens wurden die elektrochemischen Methoden und die Verfahrensparameter systematisch untersucht, ein Messsystem für Feldanwendungen entwickelt, ein Ringversuch mit über 20 Teilnehmern durchgeführt und ein Normenvorschlag erarbeitet. Die Förderzeile der Initiative WIPANO wurden erreicht. Die Erarbeitung eines auf den Ergebnissen beruhenden Normenentwurfs wird auf der nächsten Sitzung des NMP 177 gestartet.
Nachdem im Verbundprojekt COORAL das Hauptaugenmerk auf überkritisches CO2 gelegt wurde, d. h. Transport über kurze Strecken bei erhöhter Temperatur, wurde in CLUSTER ein größeres lokales Transport-Netzwerk betrachtet, bei dem CO2 bei geringeren Temperaturen, also vorwiegend im flüssigen Zustand transportiert wird. Wurden in COORAL die CO2-Ströme von Kohlekraftwerken untersucht, ging es in CLUSTER zusätzlich um die Emissionen von relevanten Industrien, deren CO2-Emissionen nicht ohne Weiteres vermieden werden können.
Aufgrund der Erfahrungen in COORAL konnte eine Auswahl von kommerziellen Werkstoffen getroffen werden, die für einen konkreten Einsatz für CCS zur Verfügung stünden. Die gemischten und fluktuierenden CO2-Zusammensetzungen sind bei geeigneten Begrenzungen der Begleit¬stoffe im CO2 bezüglich Korrosionsvorgänge beherrschbar. Die Machbarkeit eines lokalen CCS-Clusters erscheint daher gegeben, soweit dies die Anlagen für Kompression, Transport und Injektion betrifft.
In dem Vortrag werden die Highlights und Ergebnisse des abgeschlossenen Wipano Forschungsprojekts "Spannstahlsicherheit" berichtet. In dem Vorhaben wurde das Projektziel ein neues Prüfverfahren für die Prüfung von Spannstählen auf Spannungsrisskorrosionsempfindlichkeit zu entwickeln erfolgreich abgeschossen. Weiterhin wurden neue Erkenntnisse zu den Ursachen der Ergebnisstreuung der bisherigen Prüfung gemäß ISO 15630-3 gewonnen. Das neue Prüfverfahren soll bei der nächsten Überarbeitungsrunde der ISO 15630-3 als Verfahren zunächst in den informativen Anhang aufgenommen werden.
CCS technology - Carbon Dioxide Capture and Storage, has been recognized as an excellent technology to reach the target of CO2 reduction. However, the safety issue and cost effectiveness currently hinder the future of CCS. Recent studies have shown that even at a very low concentration of impurities (less than 100 ppmV of SO2, NO2, O2 and H2O) the droplet formation and condensation of sulfuric and nitric acids in dense phase CO2 are possible and observable [1-3].To reveal the mechanism of droplet corrosion in dense CO2 at high pressure and low temperature, further studies on factors that affect wettability and resulting corrosion behaviors of transport pipeline steels are needed.
In this work, carbon steel 1.8977 (L485MB), CrMo-alloyed steel 1.7225 (42CrMo4), martensitic steel 1.4313, and superaustenite steel 1.4562 (alloy 31) were investigated. The wettability was determined by contact angle measurement of sessile drop in CO2 atmosphere, at different pressure and temperature. The corrosion behavior of steels was investigated with standard exposure tests, followed by mass loss determination, surface characterization by scanning electron microscope (SEM) and chemical analysis by Energy Dispersive X-Ray Analysis (EDX). Exposure tests with and without the synthetic CO2 saturated water droplets were performed at both low temperature (278 K) and higher temperatures (288 K and 313 K) at high pressure where CO2 is supercritical or in dense phase. The investigated flue gases were SO2 (70-220 ppmV) and O2 (6700 ppmV) and water (50-200 ppmV). To reveal the effects of surface morphology, carbon steel coupons with different surface roughness were prepared to expose to CO2 stream containing oxidizing/reducing impurities to observe the condensation and the corrosion process that followed.
This book fulfills its intention to provide a comprehensive overview on 3D-printing of metals.
The interested reader can get a lot of information about the topics one should deal with when working with additively manufactured metallic parts. It gives a general roadmap where to start, what to learn and how it fits together.
This book provides a state‐of‐the‐art overview on the processing, characterization, and modelling of metallic and ceramic materials used for energy and environmental applications. 17 scientists show a collection of current knowledge in 8 chapters.
This book fulfills its intention to provide a reference book containing a collection of publications on thin films and coatings made of ceramic and metals used for energy and environmental applications. It covers a broad range of this topic and provides a comprehensive insight. Graduate and undergraduate students of materials science and mechanical engineering can find an overview on this topic to step in this interesting field of engineering.
The copper alloyed stainless steel 1.4542 (X5CrNiCuNb16-4) is used in different areas due to its good mechanical properties and corrosion resistance. Strength and corrosion resistance can be adjusted by the heat treatment, which is of importance for the application of this alloy. The mechanical properties (strength and hardness) are attributed to the dispersive precipitation of the copper rich ε–Phase. The additional precipitation of chromium carbides can reduce the corrosion resistance. Different ageing states were produced to investigate the precipitation behaviour with various methods. Furthermore, the influence of cold-rolling on the precipitation behaviour was studied in comparison to a solution annealed state without deformation. The microstructure was studied by SEM and the variations of hardness and magnetic proportion were characterised. The electrochemical potentiodynamic reactivation (EPR) was used to determine the corrosion resistance and detect chromium depletion in all heat-treated states. The results show that a work hardening accelerates the precipitation rate, while ageing at 600 °C reduces the corrosion resistance due to chromium depletion.
The copper alloyed stainless steel 1.4542 (X5CrNiCuNb16-4) is used in different areas due to its good mechanical properties and corrosion resistance. Strength and corrosion resistance can be adjusted by the heat treatment, which is of importance for the application of this alloy. The mechanical properties (strength and hardness) are attributed to the dispersive precipitation of the copper rich ε–Phase. The additional precipitation of chromi-um carbides can reduce the corrosion resistance. Different ageing states were produced to investigate the precipitation behaviour with various methods. Furthermore, the influence of cold-rolling on the precipitation behaviour was studied in comparison to a solution annealed state without deformation. The microstructure was studied by SEM and the variations of hardness and magnetic proportion were characterised. The electrochemical potentiodynamic reactivation (EPR) was used to determine the corrosion resistance and detect chromium depletion in all heat-treated states. The results show that a work hard-ening accelerates the precipitation rate, while ageing at 600 °C reduces the corrosion resistance due to chromium depletion.
The copper alloyed stainless steel 1.4542 (X5CrNiCuNb16-4) is used in different areas due to its good mechanical properties and corrosion resistance. Strength and corrosion resistance can be adjusted by the heat treatment, which is of importance for the application of this alloy. The mechanical properties (strength and hardness) are attributed to the dispersive precipitation of the copper rich ε–Phase. The additional precipitation of chromi-um carbides can reduce the corrosion resistance. Different ageing states were produced to investigate the precipitation behaviour with various methods. Furthermore, the influence of cold-rolling on the precipitation behaviour was studied in comparison to a solution annealed state without deformation. The microstructure was studied by SEM and the variations of hardness and magnetic proportion were characterised. The electrochemical potentiodynamic reactivation (EPR) was used to determine the corrosion resistance and detect chromium depletion in all heat-treated states. The results show that a work hard-ening accelerates the precipitation rate, while ageing at 600 °C reduces the corrosion resistance due to chromium depletion.
The copper alloyed stainless steel 1.4542 (X5CrNiCuNb16-4) is used in different areas due to its good mechanical properties and corrosion resistance. Strength and corrosion resistance can be adjusted by the heat treatment, which is of importance for the application of this alloy. The mechanical properties (strength and hardness) are attributed to the dispersive precipitation of the copper rich ε–Phase. The additional precipitation of chromium carbides can reduce the corrosion resistance. Different ageing states were produced to investigate the precipitation behaviour with various methods. Furthermore, the influence of cold-rolling on the precipitation behaviour was studied in comparison to a solution annealed state without deformation. The microstructure was studied by SEM and the variations of hardness and magnetic proportion were characterised. The electrochemical potentiodynamic reactivation
(EPR) was used to determine the corrosion resistance and detect chromium depletion in all heattreated states. The results show that a work hardening accelerates the precipitation rate, while ageing at 600 °C reduces the corrosion resistance due to chromium depletion.
The copper alloyed stainless steel 1.4542 (X5CrNiCuNb16-4) is used in different areas due to its good mechanical properties and corrosion resistance. Strength and corrosion re-sistance can be adjusted by the heat treatment, which is of importance for the application of this alloy. The mechanical properties (strength and hardness) are attributed to the dispersive precipitation of the copper rich ε–Phase. The additional precipitation of chromium carbides can reduce the corrosion resistance. Different ageing states were produced to investigate the precipitation behaviour with various methods. Furthermore, the influence of cold-rolling on the precipitation behaviour was studied in comparison to a solution annealed state without deformation. The microstructure was studied by SEM and the variations of hardness and magnetic proportion were characterised. The electrochemical potentiodynamic reactivation (EPR) was used to determine the corrosion resistance and detect chromium depletion in all heat-treated states. The results show that a work hardening accelerates the precipitation rate, while ageing at 600 °C reduces the corrosion re-sistance due to chromium depletion.
Aging of passive film formed on UNS N08031 was investigated as a function of passivation time in Green-Death solution at 40°C. The specimen surface was in a stable passive state in the solution.
The passive current density increased with an increase in the passivation potential. Electrochemical Impedance Spectroscopy and Mott–Schottky (M–S) analyses revealed that a more defective n-type
semiconductive passive film formed as the potential increased while the film became stable as the defects in the film decreased at potential lower than 1.0 VSSE. The increase of the applied potential and the polarisation time are likely reasons for the change in passive film stability.
Analyzing the performance of discrete galvanic anode systems using electrochemical investigations
(2021)
Corrosion of reinforcement is one of the major reasons in questioning the service life of building structures. The application of cathodic protection techniques plays a big role in controlling the corrosion process to ensure a longer service life of building structures. This systematic study compares the efficiency and durability of various discrete galvanic zinc anode systems available in the current market using different criteria for measuring efficiency such as potential measurements, electrolyte resistance measurements and several polarization methods to determine the polarizability of the anodes. The results to validate the performance of long-time exposure of discrete zinc anodes in concrete medium are discussed.
Nickel‐free high‐nitrogen‐alloyed stainless steels like the P2000 (X13CrMnMoN18‐14‐3) were developed to enhance the strength and corrosion resistance of austenitic stainless steels like 304 and 316 while keeping the typical high ductility. The mechanical and corrosive properties of P2000 were investigated and compared with 304 and 316 to highlight the application opportunities of this new alloy. The microstructure of the solution‐annealed condition was characterised by electron backscatter diffraction and the mechanical properties were studied by uniaxial tensile tests, Charpy impact tests and hardness measurements. The passivation behaviour was analysed using the electrochemical potentiodynamic reactivation, whereas the pitting corrosion resistance was compared by pitting potentials and pitting temperatures. However, secondary thermal influences or suboptimal heat treatment can impair the corrosion resistance due to the precipitation of secondary phases and the resulting sensitisation. Thermodynamic calculations and artificial ageing treatment in the range of 500–900°C for up to 100 h were used to determine critical time–temperature parameters for sensitisation. The microstructure of the various aged states was evaluated by scanning electron microscopy and compared with the degrading corrosion resistance characterised by the KorroPad method.
The double loop electrochemical potentiodynamic reactivation (EPR) method is a standardised procedure for detecting and quantifying sensitisation on austenitic, ferritic and ferritic-austenitic stainless-steel grades. This sensitisation is caused by microstructural alternations, as the formation of chromium carbides, nitrides or sigma-phases, which generate local chromium depleted zones nearby. The latter strongly influence the corrosion resistance and the electrochemical response of a stainless steel during electrochemical potentiodynamic reactivation, providing important information on the degree of chromium depletion. In case of martensitic stainless steels, which are used for cutlery and surgical instruments, the heat treatment has a strong impact on the microstructure, the material properties and especially on the corrosion resistance. To study this interaction, the EPR method was modified for the application on martensitic stainless steels with about 13 wt.-% chromium. Different H2SO4 concentrations and EPR-parameters were tested and compared on two standard martensitic stainless-steel grades (AISI 420 A / X20Cr13 and AISI 420 C / X46Cr13) to define applicable parameters. Afterwards, these parameters were used to study the effect of austenitisation time and cooling rate on the corrosion resistance of both martensitic stainless steels. The response of both alloys was different due to the different carbon levels, which will be explained by microstructural investigations in detail. All results allow postulating a process window, in which chromium depletion is suppressed and an optimised corrosion resistance is guaranteed. Based on this research, the modified EPR-test is now used to control the heat treatment and its impact on the corrosion resistance of martensitic stainless steels in the cutlery industry. The EPR-test is thus an interesting alternative for manufacturers, processors, users and researchers to the time-consuming exposition test normally used to characterise the corrosion resistance of martensitic stainless steels.
Im Sinne einer mittel- bis langfristigen Reduktion wartungsbedingter Verkehrsbeeinflussungen in Tunnelbauwerken ist es von Bedeutung, die intensiven und aufwendigen Reinigungs- und Pflegearbeiten für Ein- und Anbauteile aus nichtrostendem Stahl in Straßentunneln zu reduzieren. Unter diesem Aspekt besteht großes Interesse die Einsatzmöglichkeiten alternativer nichtrostender Stähle, zu den bislang gebräuchlichen nichtrostenden austenitischen Stählen 1.4404 und 1.4571, zu eruieren. In dem Forschungsprojekt geht es um die Qualifizierung nichtrostender ferritisch austenitischer Stähle (Duplexstahl) in Straßentunneln. Diese verfügen im Vergleich zu austenitischen Stählen über eine doppelt so hohe Festigkeit bei gleichzeitig hoher Korrosionsbeständigkeit. In dieser Präsentation werden die Auslagerungsergebnisse nach 3 Jahren vorgestellt.
Der Vortrag berichtet über die Auslagerung von Standardproben nach DIN EN ISO 9223 bis 9226 aus Zink, Stahl, Kupfer und Aluminium auf den verschiedenen atmosphärischen Bewitterungsständen der Bundesanstalt für Materialforschung und -prüfung (BAM). Im Vortrag werden die Masseverluste, Korrosionsgeschwindigkeiten und Korrosivitätskategorien der Standardproben im freibewitterten und überdachten Bereich nach einem Jahr vorgestellt und Unterschiede hinsichtlich der Atmosphärenbedingungen aufgezeigt. Freibewitterte Proben zeigen dabei deutliche Unterschiede hinsichtlich ihres Korrosionsverhaltens im Vergleich zu überdachten Proben. Die ermittelten Korrosivitätskategorien sind sowohl standort- als auch materialspezifisch.
Der Vortrag berichtet über die Auslagerung von Standardproben nach DIN EN ISO 9223 bis 9226 aus Zink, Stahl, Kupfer und Aluminium auf den verschiedenen atmosphärischen Bewitterungsständen der Bundesanstalt für Materialforschung und -prüfung (BAM). Im Vortrag werden die Masseverluste, Korrosionsgeschwindigkeiten und Korrosivitätskategorien der Standardproben im freibewitterten und überdachten Bereich nach einem Jahr vorgestellt und Unterschiede hinsichtlich der Atmosphärenbedingungen aufgezeigt. Freibewitterte Proben zeigen dabei deutliche Unterschiede hinsichtlich ihres Korrosionsverhaltens im Vergleich zu überdachten Proben. Die ermittelten Korrosivitätskategorien sind sowohl standort- als auch materialspezifisch.
Der Vortrag berichtet über die Auslagerung von Standardproben nach DIN EN ISO 9223 bis 9226 aus Zink, Stahl, Kupfer und Aluminium auf den verschiedenen atmosphärischen Bewitterungsständen der Bundesanstalt für Materialforschung und -prüfung (BAM). Im Vortrag werden die Masseverluste, Korrosionsgeschwindigkeiten und Korrosivitätskategorien der Standardproben im freibewitterten und überdachten Bereich nach einem Jahr vorgestellt und Unterschiede hinsichtlich der Atmosphärenbedingungen aufgezeigt. Freibewitterte Proben zeigen dabei deutliche Unterschiede hinsichtlich ihres Korrosionsverhaltens im Vergleich zu überdachten Proben. Die ermittelten Korrosivitätskategorien sind sowohl standort- als auch materialspezifisch.
Der Vortrag berichtet über die Auslagerung von Standardproben nach DIN EN ISO 9223 bis 9226 aus Zink, Stahl, Kupfer und Aluminium auf den verschiedenen atmosphärischen Bewitterungsständen der Bundesanstalt für Materialforschung und -prüfung (BAM). Im Vortrag werden die Masseverluste, Korrosionsgeschwindigkeiten und Korrosivitätskategorien der Standardproben im freibewitterten und überdachten Bereich nach einem Jahr vorgestellt und Unterschiede hinsichtlich der Atmosphärenbedingungen aufgezeigt. Freibewitterte Proben zeigen dabei deutliche Unterschiede hinsichtlich ihres Korrosionsverhaltens im Vergleich zu überdachten Proben. Die ermittelten Korrosivitätskategorien sind sowohl standort- als auch materialspezifisch.
Anhand der Wirksumme ist eine Abschätzung des legierungsabhängigen Einflusses auf den Korrosionswiderstand gegen chloridhaltige Medien möglich. Die berechneten Werte sind nur bei optimaler Wärmebehandlung und Verarbeitung zutreffend.
Die Anwendung einer einfachen Formel unter Berücksichtigung von Chrom, Molybdän und Stickstoff ist in der Regel völlig ausreichend. Das daraus abgeleitete Ranking von Werkstoffen ist für diverse technische Regelwerke und zur Unterstützung der Werkstoffauswahl geeignet.
Für die Warenein-/Ausgangskontrolle ist die alleinige Feststellung der Wirksumme unzureichend. Ergänzende Korrosionsuntersuchungen/-prüfungen zur Beschreibung des Korrosionswiderstandes sind dafür notwendig. Gleiches gilt für die Beurteilung von Schadensfällen. Hier sind Verarbeitung, Einsatzbedingungen und die Konstruktion von ausschlaggebender Bedeutung.
Unter Passivität versteht man den Korrosionsschutz durch dünne, festhaftende Schichten aus Korrosionsprodukten. Für den schadensfreien Einsatz nichtrostender Stähle ergeben sich daraus zwei grundsätzliche Anforderungen.
Erstens muss sich die Passivschicht vollständig ausbilden können. Dabei sind die Oberflächenausführung, die mechanische Bearbeitung, die Elementverteilung, Ausscheidungen, die Wärmeeinbringung z.B. bei der schweißtechnischen Verarbeitung, Anlauffarben, sowie die chemische Nachbehandlung bzw. Konditionierung der Oberflächen von großer Bedeutung. Zweitens muss die Repassivierung von Defektstellen unter den Einsatzbedingungen möglich sein. Für das Repassivierungsvermögen sind die Legierungszusammensetzung, mögliche kritische Betriebszustände, prozessbedingte Besonderheiten, wie etwa Stagnationsbedingungen und Reinigungsprozesse von Bedeutung.
Unter Passivität versteht man den Korrosionsschutz durch dünne, festhaftende Schichten aus Korrosionsprodukten. Für den schadensfreien Einsatz nichtrostender Stähle ergeben sich daraus zwei grundsätzliche Anforderungen, die stets erfüllt sein müssen.
Erstens muss sich die Passivschicht vollständig ausbilden können. Dabei sind die Oberflächenausführung,die mechanische Bearbeitung,die Elementverteilung, Ausscheidungen, die Wärmeeinbringung z.B. bei der schweißtechnischen Verarbeitung, Anlauffarben, sowie die chemische Nachbehandlung bzw. Konditionierung der Oberflächen von großer Bedeutung. Zweitens muss die Repassivierung von möglichen Defektstellen unter den Einsatzbedingungen möglich sein. Für das Repassi-vierungsvermögen sind die Legierungszusammensetzung, mögliche kritische Betriebszustände, prozessbedingte Besonderheiten wie etwa Stagnationsbedingungen und Reinigungsprozesse von Bedeutung.
Unter Passivität versteht man den Korrosionsschutz durch dünne, festhaftende Schichten aus Korrosionsprodukten. Für den schadensfreien Einsatz nichtrostender Stähle ergeben sich daraus zwei grundsätzliche Anforderungen.
Erstens muss sich die Passivschicht vollständig ausbilden können. Dabei sind die Oberflächenausführung,die mechanische Bearbeitung,die Elementverteilung, Ausscheidungen, die Wärmeeinbringung z.B. bei der schweißtechnischen Verarbeitung, Anlauffarben, sowie die chemische Nachbehandlung bzw. Konditionierung der Oberflächen von großer Bedeutung. Zweitens muss die Repassivierung von möglichen Defektstellen unter den Einsatzbedingungen möglich sein. Für das Repassivierungsvermögen sind die Legierungszusammensetzung, mögliche kritische Betriebszustände, prozessbedingte Besonderheiten wie etwa Stagnationsbedingungen und Reinigungsprozesse von Bedeutung.
Die Anforderungen in verschiedenen Fachgebieten des Bauwesens an metallene Befestigungsmittels hinsichtlich des Korrosionsschutzes sind zum einen Abhängig von den verwendeten Werkstoffen und zum anderen von der Korrosivität in der jeweiligen Exposition. Hier wird ein Überblick über die gängigen Werkstoffe als auch Anwendung und Fehlerquellen verschafft
Corrosion of steel reinforcement in concrete is one of the major deterioration mechanisms limiting the service life of reinforced concrete structures. While for conventional (Portland cement-based) concretes a great amount of experience exists in this regard, the factors that determine the onset of reinforcement corrosion in alkali-activated materials are incompletely understood yet. One aspect of corrosion protection is leaching and the accompanying changes of the concrete pore solution. In the present study, alkali-activated fly ash mortars with embedded carbon steel rebars were exposed to de-ionised water for periods up to 330 days, and the electrochemical response of the steel (free corrosion potential, polarisation resistance), the alteration of the mortar (ohmic resistance, mechanical strength, pore size distribution) as well as the pore solution composition were monitored. Although substantial alkali leaching was observed, the pH of the pore solution remained at values sufficient to protect the embedded steel from depassivation. The mortar did not exhibit indications of significant deterioration. Thus, the present results suggest that leaching is not critical for protection of steel reinforcement in alkali-activated fly ash mortars and concretes.
Corrosion of steel reinforcement in concrete is one of the major deterioration mechanisms limiting the service life of reinforced concrete structures. While for conventional (Portland cement-based) concretes a great amount of experience exists in this regard, the factors that determine the onset of reinforcement corrosion in alkali-activated materials are incompletely understood yet.
One aspect of corrosion protection is leaching and the accompanying changes of the concrete pore solution. In the present study, alkali-activated fly ash mortars with embedded carbon steel rebars were exposed to de-ionised water for periods up to 330 days, and the electrochemical response of the steel (free corrosion potential, polarisation resistance), the alteration of the mortar (ohmic resistance, mechanical strength, pore size distribution) as well as the pore solu¬tion composition were monitored.
Although substantial alkali leaching was observed, the pH of the pore solution remained at values sufficient to protect the embedded steel from depassivation. The mortar did not exhibit indications of significant deterioration. Thus, the present results suggest that leaching is not critical for pro¬tec¬tion of steel reinforcement in alkali-activated fly ash mortars and concretes.
Der Vortrag stellt ein neuartiges Korrosionsprüfverfahren für Zinküberzüge auf Basis gelartiger Elektrolyte vor und führt die Vorteile gegenüber konventionellen Prüfverfahren auf. Basierend auf den Ergebnissen wird die Idee für einen IGF-Projektantrag in Kooperation mit dem Fraunhofer IKTS vorgestellt.
Der Vortrag stellt ein neuartiges Korrosionsprüfverfahren für Zinküberzüge auf Basis gelartiger Elektrolyte vor und führt die Vorteile gegenüber konventionellen Prüfverfahren auf. Basierend auf den Ergebnissen wird die Idee für einen IGF-Projektantrag in Kooperation mit dem Fraunhofer IKTS vorgestellt.
Aus Rapsöl gewonnener Biodiesel ist eine umweltfreundliche Alternative zu fossilen Energiequellen. In der Europäischen Union, in der 80 % der ölhaltigen Brennstoffe importiert werden müssen, besteht zudem ein Interesse, die Abhängigkeit von exter-nen Ölversorgern zu reduzieren.
Bei jeder Veränderung der Zusammensetzung eines Brennstoffs muss auch die Ma-terialverträglichkeit gewährleistet bleiben. Es stellt sich die Frage, ob Elastomere im Vergleich zu reinem Heizöl auch in Heizöl mit 20 % Biodiesel (B20) beständig sind.
Die Polarität des Biodiesels erhöht die Quellung und fördert die Permeation und Ex-traktion. Sowohl Quellung als auch Extraktion bedingen Änderungen der physikali-schen Eigenschaften der Elastomere. Extraktion verändert die chemische des Heiz-öls. Diese chemischen Veränderungen können auch den Abbau (Hydrolyse und Oxi-dation) der Polymere durch das Herauslösen von Additiven und Stabilisatoren be-schleunigen.
Ziel dieser Arbeit war die Bestimmung der Beständigkeit der Elastomere ACM (Poly-acrylatkautschuk), HNBR (Hydrierter Acrylnitrilbutadienkautschuk), FKM (Fluorkaut-schuk) und PUR (Polyurethan) in Heizöl und im Heizölgemisch B20.
Prüfkörper der Elastomere wurden für 42 Tage (Härteprüfung) und 84 Tage (Zugprü-fung) bei 40 °C ausgelagert. Anschließend wurde die Änderung der Masse, Shore Härte A, Zugfestigkeit, und Reißdehnung bezogen auf die Werte vor der Aus-lagerung bestimmt. Die weniger zur Quellung neigenden Elastomere FKM und HNBR wurden zusätzlich bei 70 °C ausgelagert.
Um die Elastomere im verpressten Zustand zu testen, wurde der Druckverformungs-rest nach DIN ISO 815 bestimmt. Hierzu wurden zylindrische Prüfkörper aus ACM, HNBR und FKM verpresst und in Heizöl und Heizöl mit 20 % FAME für 3, 7, 14, 28, 56 und 90 Tage bei 40 °C ausgelagert. Anschließend wurde über die Dickenmes-sung der Druckverformungsrest ermittelt. Zum Vergleich wurden Prüfkörper verpresst und ohne Medium bei 40 °C ausgelagert.
In den internationalen Normen wurde kein Grenzwert für die Veränderung der Zugei-genschaften und der Härte für eine positive Bewertung der Beständigkeit festgelegt. Deshalb wurde in der BAM ein Grenzwert von 15 % für die Beständigkeitsbewertung herangezogen.
Bei 40 °C lag die Änderung der Zugeigenschaften und der Shore Härte von ACM, HNBR und FKM in Heizöl und in B20 unter 15 %. Folglich sind ACM, HNBR und FKM bei 40 °C in Heizöl und in B20 beständig. PUR ist bei 40 °C in Heizöl beständig, je-doch nicht für eine Verwendung in B20 geeignet, da sich die Zugfestigkeit und Reiß-dehnung um 50 % vermindert haben.
Bei 70 °C ist FKM in Heizöl und B20 beständig, wohingegen HNBR an seine Einsatz-grenzen gelangt und unbeständig ist, in B20 haben sich die Zugfestigkeit um 40 % und die Reißdehnung um 50 % reduziert.
Der kritische, Korrosion auslösende Chloridgehalt für die Beurteilung der Korrosions-beständigkeit von Betonstahl in Geopolymerbetonen ist von großer Bedeutung für die Dauerhaftigkeitsprognose für bewehrte Elemente aus solchen Materialien. Es sind kaum experimentelle Daten in der Fachliteratur vorhanden und die vorliegenden Werte unterscheiden sich zwischen den Studien erheblich. In diesem Projekt wurde der kritische, Korrosion auslösende Chloridgehalt für Betonstahl (BSt 500) in flugaschebasierten (Ca-armen) Geopolymermörtel für verschiedene Beaufschlagungskombinationen bestimmt: Chloridbeaufschlagung mit 1 M NaCl-Lösung; Auslaugen in entionisiertem Wasser und anschließende Chloridbeaufschlagung im 1 M NaCl-Lösung; Auslaugen in entionisiertem Wasser, Carbonatisierung in Luft bei 20 °C und natürlicher CO2 Konzentration und anschließende Chloridbeaufschlagung mit 1 M NaCl-Lösung. Für Referenz-Zwecke wurde zusätzlich der Korrosion auslösende Chloridgehalt für eine Portland-Zement Mischung bei Auslagerung in 1 M NaCl-Lösung bestimmt.
Für Bauteile (Komponenten) von Versorgungsanlagen für flüssige Brenn- und Kraftstoffe muss die Beständigkeit der metallenen Werkstoffe und Polymere nachgewiesen werden. Im Anwendungsfall von Heizöl mit 20 % biogenen Anteilen in Form von Rapsölfettsäuremethylester (FAME, Biodiesel) ist es für eine konservative Beurteilung des Korrosionssystems Werkstoff/Medium/Umgebung wichtig, die Alterungseffekte des Mediums einzubeziehen.
Entwicklung eines Prüfverfahrens für die Untersuchung der Beständigkeit von metallenen Werkstoffen und Polymeren in Heizöl und Heizöl-Biodiesel-Blends, das für eine Vorauswahl der Werkstoffe und zum Nachweis der Beständigkeit im Hinblick auf die bauaufsichtlichen Zulassungsverfahren geeignet ist. Ein Schwerpunkt wird bei den metallenen Werkstoffen auf der Erprobung von Messmethoden liegen, mit denen sich in kurzer Versuchszeit ein Korrosionsangriff detektieren lässt.