Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (367) (entfernen)
Sprache
- Englisch (367) (entfernen)
Schlagworte
- Fluorescence (22)
- ICP-MS (21)
- Mass spectrometry (18)
- Nanoparticle (17)
- Laser ablation (16)
- Quality assurance (13)
- BAMline (10)
- Imaging (10)
- Quantum yield (10)
- Synchrotron (10)
- Cancer (9)
- Mycotoxins (9)
- Traceability (9)
- Calibration (8)
- Cell (8)
- Luminescence (8)
- MALDI-TOF MS (8)
- Mass-Spectrometry (8)
- Metrology (8)
- Reference material (8)
- Lifetime (7)
- Mechanochemistry (7)
- Microplastics (7)
- Quantitative spectroscopy (7)
- Immunoassay (6)
- Microplastic (6)
- Nano (6)
- TED-GC/MS (6)
- Analytical Chemistry (5)
- Dye (5)
- Electrochemistry (5)
- Energy transfer (5)
- Food (5)
- LA-ICP-MS (5)
- LC-MS/MS (5)
- Magnetic resonance imaging (5)
- Mass Spectrometry (5)
- Metabolomics (5)
- PFAS (5)
- Particle (5)
- Polylactide (5)
- Reproducibility (5)
- Spectroscopy (5)
- Synthesis (5)
- Transformation products (5)
- Uncertainty (5)
- XRF (5)
- Automation (4)
- CCQM (4)
- Copper (4)
- Food analysis (4)
- HRMS (4)
- Human serum (4)
- Immunohistochemistry (4)
- In situ (4)
- Industry 4.0 (4)
- Interlaboratory comparison (4)
- Isotope dilution (4)
- LIBS (4)
- Nanoparticles (4)
- Sulfur (4)
- Tumor metabolism (4)
- XRD (4)
- Absolute isotope ratio (3)
- Acoustic levitation (3)
- Adsorption (3)
- Bioconjugation (3)
- Bioimaging (3)
- Brain (3)
- CONSENS (3)
- CRM (3)
- Cement (3)
- ELISA (3)
- Ergot alkaloids (3)
- Fatty acid metabolism (3)
- GDMS (3)
- Gadolinium (3)
- Gas chromatography (3)
- HPLC (3)
- HR-CS-MAS (3)
- Lanthanide (3)
- Lipidomic profile (3)
- MC-ICP-MS (3)
- Mass Spectroscopy (3)
- Measurement uncertainty (3)
- Metabolic stress (3)
- Method (3)
- Modular Production (3)
- Mycotoxin (3)
- Nanomaterials (3)
- Probe (3)
- Process Analytical Technology (3)
- Purity assessment (3)
- Quality control (3)
- Sensor (3)
- Soil (3)
- AAS (2)
- Abwasser (2)
- Affinity chromatography (2)
- Amino acid analysis (2)
- Amperometry (2)
- Amplification (2)
- Antibody (2)
- Aromatic amino acid analysis (2)
- Array (2)
- Artificial neural networks (2)
- BODIPY (2)
- Benz[a]anthracene (BaA) (2)
- Benzo[a]pyrene (BaP) (2)
- Biomarker (2)
- Biosensing (2)
- CXC (2)
- Cells (2)
- Certified reference material (2)
- Chlorine (2)
- Chromatography (2)
- Cocoa (2)
- Combustion ion chromatography (CIC) (2)
- Conjugate (2)
- Core-shell particles (2)
- Crystalinity (2)
- Crystallization (2)
- Cyclization (2)
- Degradation (2)
- Delta value (2)
- Derivatization (2)
- Diagnosis (2)
- Diagnostics (2)
- Diatoms (2)
- Diclofenac (2)
- Electrocatalysis (2)
- Environmental speciation (2)
- Epoxy (2)
- Extracellular matrix (2)
- Extractable organically bound fluorine (EOF) (2)
- Fluorine (2)
- GD-OES (2)
- Gas chromatography (GC) (2)
- General Earth and Planetary Sciences (2)
- General Materials Science (2)
- Graphite furnace (2)
- HPLC-MS/MS (2)
- Heart failure (2)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (2)
- Hydrazinolysis (2)
- Hydrogen (2)
- Hydrolysis (2)
- ILC (2)
- Iron (2)
- Isotope (2)
- Isotope dilution (ID) (2)
- Isotope dilution mass spectrometry (2)
- Isotope ratio (2)
- Isotope ratios (2)
- Isotopic fractionation (2)
- Li-ion battery (2)
- Lipidomics (2)
- Liquid chromatography (2)
- Liquid chromatography (LC) (2)
- Lithium (2)
- MALDI (2)
- MALDI TOF MS (2)
- MRI (2)
- MYCN (2)
- Machine learning (2)
- Magnetic beads (2)
- Mass spectrometry (MS) (2)
- Mercury (2)
- Metals (2)
- Method development (2)
- Mobile phase (2)
- Molar mass (2)
- Molecularly imprinted polymers (2)
- Multimodal (2)
- Nanopartikel (2)
- Nickel (2)
- Nitrotyrosine (2)
- Online NMR spectroscopy (2)
- Oxygen sensor (2)
- Peptide analysis (2)
- Peptide library (2)
- Permethrin (2)
- Pesticide (2)
- Phenylalanine (2)
- Photodegradation (2)
- Plasma (2)
- Plasma modeling (2)
- Pollen (2)
- Polycyclic aromatic hydrocarbon (PAH) (2)
- Polymer (2)
- Process analytical technology (2)
- Purity (2)
- Quantification (2)
- Quantitative protein analysis (2)
- R package (2)
- Raman (2)
- Real-time process monitoring (2)
- Reference materials (2)
- SAXS (2)
- SBA-15 (2)
- SERS (2)
- SI (2)
- SI traceability (2)
- Screening (2)
- Single particle ICP-MS (2)
- Sr isotopes (2)
- Standardization (2)
- Surface water (2)
- TGA-FTIR (2)
- Tire wear (2)
- Transformation product (2)
- Triple isotope fractionation (2)
- Tyrosine (2)
- VOC (2)
- Validation (2)
- Volatile organic compounds (2)
- Wastewater (2)
- Water (2)
- XANES (2)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 2-propanol oxidation (1)
- 280 nm (1)
- 3D ultrastructural analysis (1)
- 3D-printing (1)
- 5-Bromouracil (1)
- 6xHis (1)
- A4F (1)
- AAA (1)
- AAAA (1)
- ABC (1)
- ABID (1)
- AF4 (1)
- AFM (1)
- AG nanoparticle (1)
- ANOVA (1)
- ATCUN (1)
- AU nanoparticle (1)
- Absorption spectrometry (1)
- Accuracy (1)
- Acidic oxygen evolution reaction (1)
- Acoustic (1)
- Acrylamide (1)
- Acute myocardial infarction (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Advanced nanomaterials (1)
- Aeroacoustics (1)
- Affinity Chromatography (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity extraction (1)
- Aflatoxins (1)
- Air analysis (1)
- Air filter samples (1)
- Air particulate matter (1)
- Air-coupled ultrasound (1)
- Airport (1)
- Akaike information criterion picker (1)
- AlCl (1)
- Albumin (1)
- Alcohol electrooxidation (1)
- Algorithms (1)
- Allergy (1)
- Altenuene (1)
- Alternaria mycotoxins (1)
- Aluminium (1)
- Aluminum (1)
- Aluminum alloys (1)
- Aluminum oxide (1)
- Alzheimer’s disease (1)
- Ambient pressure laser ionization (1)
- Amyloid (1)
- Amyloid-beta (1)
- Analysis (1)
- Analytical chemistry (1)
- Analytical methods (1)
- Anemia (1)
- Anilinopyridine (1)
- Anion receptors (1)
- Annealing (1)
- Antagonists (1)
- Anthropocene (1)
- Antibody Purification (1)
- Antibody antigen complex (1)
- Antibody conjugates (1)
- Antibody identification (1)
- Antibody quality (1)
- Antibody quantification (1)
- Antibody-gated indicator delivery (1)
- Antifouling biocides (1)
- Antikensammlung Berlin (1)
- Antikörper (1)
- App (1)
- Archaeometry (1)
- Arsenite (1)
- Artificial Neural Networks (1)
- Aspergillus (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Atmospheric aerosol (1)
- Atomic Absorption Spectrometry (1)
- Atomic Force Microscopy (1)
- Atomic absorption spectrometry (1)
- Atomic and molecular physics, and optics (1)
- Atomic layer deposition (1)
- Augmented data (1)
- Automated Purification (1)
- Automated image analysis (1)
- Automated system (1)
- Automatisierung (1)
- Autophagy (1)
- Aviation (1)
- Avogadro constant (1)
- BCA test (1)
- BERM (1)
- BLE Bluetooth low energy (1)
- BPA removal (1)
- Back-side integration (1)
- Bacterial lysates (1)
- Bakterien (1)
- Barium (1)
- Basic solvent (1)
- Battery (1)
- Bawit (1)
- Bbeverages (1)
- Bead injection spectroscopy (1)
- Bead-based assay (1)
- Benchtop NMR Spectroscopy (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Binder (1)
- Binding strength (1)
- Bio-interaction (1)
- Bioactive glass (1)
- Bioapatite (1)
- Biochemistry (1)
- Biochip (1)
- Biodiesel fuel (1)
- Biogenic carbonates (1)
- Bioinformatics (1)
- Biological & biomedical applications (1)
- Biological boron recycling (1)
- Biopolymers Probes (1)
- Biosensor (1)
- Biosensors (1)
- Bioseparation (1)
- Biosilicification (1)
- Biosynthesis (1)
- Biotests (1)
- Biotransformation (1)
- Bismuth (1)
- Bisphenol A (1)
- Bisphenol-A (1)
- Block copolymer (1)
- Blood-brain barrier (1)
- Bombs (1)
- Bone matrix (1)
- Boron isotope (1)
- Boron isotope fractionation (1)
- Boron isotopic composition (1)
- Borosilicate Glass (1)
- Borosilicate glass (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Brassica napus (1)
- Breath (1)
- Byproducts (1)
- CCQM key comparison (1)
- CE/MC-ICP-MS (1)
- COVID-19 (1)
- CRP (1)
- CT simulation (1)
- CaCl emission bands (1)
- Cadmium (1)
- Calcification (1)
- Calcium (1)
- Calcium monofluoride (1)
- Cancer awareness measure (1)
- Cancer cells (1)
- Cancer risk (1)
- Cancer therapy (1)
- Canine olfactometry (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Capillary electrophoresis-mass spectrometry (1)
- Carbodiimide crosslinking (1)
- Carboxyl group (1)
- Cardiac troponin (1)
- Cardiolipins (1)
- Cardiovascular (1)
- Carrier (1)
- Carrier gas hot extraction (1)
- Catalysts (1)
- Cathode material (1)
- Cconventional method (1)
- CdSe/ZnS quantum Dots (1)
- Cellular trafficking (1)
- Cellular uptake (1)
- Central Taurus (1)
- Certification (1)
- Charge Transfer (1)
- Chemical Process Control (1)
- Chemical Safety (1)
- Chemical protein modification (1)
- Chemical sensors (1)
- Chemical transformation (1)
- Chemiluminescence (1)
- Chenopodium album (1)
- Chicken antibodies (1)
- Chlorides (1)
- Chlorine determination (1)
- Chronic kidney disease (1)
- Citizen Science (1)
- Classical primary measurement method (CPM) (1)
- Classification (1)
- Cleaning (1)
- Cleavage (1)
- Climate (1)
- Clinical Biochemistry (1)
- Clone M2 (1)
- Cluster (1)
- Cobalt deposition (1)
- Coded Aperture (1)
- Colorimetric Test (1)
- Column holder (1)
- Combustion (1)
- Combustion ion chromatography (1)
- Comparability (1)
- Competitive immunoassay (1)
- Complementary MS (1)
- Complex (1)
- Complexation (1)
- Compost (1)
- Compound-independent calibration (1)
- Computed tomography (1)
- Comsumer good samples (1)
- Concentration step (1)
- Confocal laser scanning microscopy (1)
- Construction (1)
- Consumer Products (1)
- Continuous Sensor (1)
- Continuous processes (1)
- Contrast agent (1)
- Conventional isotope ratio (1)
- Converter material (1)
- Coordination polymers (1)
- Coptic manuscripts (1)
- Corona virus (1)
- Corophium volutator (1)
- Corrosion (1)
- Coulometric sensors (1)
- Coumarin (1)
- Coupling reactions (1)
- Cr(III) (1)
- Cr(III) complex (1)
- Cryo-soft X-ray tomography (1)
- Cryoadsorption (1)
- Cyanide (1)
- Cyanide in soil (1)
- Cyber-Physical Systems (1)
- Cyber-physical system (1)
- Cyber-physical systems (1)
- Cyclic voltammetry (1)
- Cycloparaphenylenes (1)
- Cytoplasm (1)
- Cytoplasmic remodeling (1)
- D-glucose (1)
- D2XRF (1)
- DC-Arc (1)
- DEA (1)
- DHAP (1)
- DNA (1)
- DNA origami (1)
- DNA radiation damage (1)
- DNA strand breaks (1)
- Damage-associated molecular patterns (DAMPs) (1)
- Data Analysis (1)
- Data Fusion (1)
- Data processing (1)
- Debromination (1)
- Debye-Waller parameter (1)
- Delta scale (1)
- Dendrite growth (1)
- Dendritic polyglycerol sulfate (1)
- Density functional theory (1)
- Density separation (1)
- Depht profiling (1)
- Depth profile (1)
- Deuterium (1)
- Deuterium enriched water (1)
- Diagenesis (1)
- Diagnostic Antibodies (1)
- Diastolic dysfunction (1)
- Diatomic molecule (1)
- Diesel exhaust (1)
- Diffusion (1)
- Digestion (1)
- Digital Transformation (1)
- Digital twins (1)
- Digitale Transformation (1)
- Digitalisation (1)
- Dimerization (1)
- Dip-stick assay (1)
- Direct alcohol fuel cells (1)
- Direct metal assay (1)
- Dispersive-XAS (1)
- Dissociation constant (1)
- Dissolution (1)
- Dityrosine (1)
- Down Stream Processing (1)
- Downstream processing (1)
- Dried fig (1)
- Droplets (1)
- Drug Discovery (1)
- Drug transporters (1)
- Duplex stainless steels (1)
- Dye monomers (1)
- Dyes/pigments (1)
- E. coli (1)
- EC/LC/MS (1)
- EC/MS (1)
- ECR (1)
- EDTAD (1)
- EPMA (1)
- EPR spectroscopy (1)
- ESEM (1)
- ESMA (1)
- ETV (1)
- EU-WFD (1)
- EXAFS (1)
- Early Earth (1)
- Ecotoxicity (1)
- Ecotoxicological Testing (1)
- Ecotoxicology testing (1)
- Editorial (1)
- Einzelzellanalyse (1)
- Elastin-specific contrast agent ESMA (1)
- Elastin-specific molecular agent (1)
- Electrochemical Reactor (1)
- Electrochemical energy conversion (1)
- Electrochemical oxidation (1)
- Electrochemical real-time mass spectrometry (1)
- Electrochemistry mass spectrometry (1)
- Electromagnetic (1)
- Electronic Lab Notebook (ELN) (1)
- Electronic nose (1)
- Electrospray (1)
- Elektronenmikroskopie (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Elemental analysis (1)
- Elemental composition (1)
- Elemental fingerprints (1)
- Emergency (1)
- Emerging brominated flame retardant (1)
- Emerging contaminants (1)
- Emerging/novel brominated flame retardant (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Energy storage (1)
- Environmental analysis (1)
- Environmental impacts (1)
- Environmental pollutants (1)
- Environmental pollution monitoring (1)
- Equilibrium constant (1)
- Escherichia coli (1)
- Esterification (1)
- Estrogens (1)
- Ethyl glucuronide (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- European Reference Material (1)
- Exhaust (1)
- Experimental design (1)
- Exposure (1)
- Extended X-ray absorption fine structure (1)
- Extractable organic fluorine (1)
- Extraction (1)
- FAIR research data management (1)
- FLAG peptide (1)
- FLIM (1)
- FPLC (1)
- FTIR (1)
- FTIR spectroscopy (1)
- Fast flow GD (1)
- Fast single pulse response (1)
- Fatty acid desaturation (1)
- Fatty acid synthesis (1)
- Fatty acid uptake (1)
- Fatty acids (1)
- Fe nanoparticles metabolism (1)
- Fenton (1)
- Fenton’s reagent (1)
- Fertilizer (1)
- Festphasenextraktion (1)
- Filter crucible (1)
- Finow Canal (1)
- Flow Chemistry (1)
- Flow cytometry (1)
- Flow injection immunoassay (1)
- Fluidics (1)
- Fluorescence lifetime (1)
- Fluorescence sensing (1)
- Fluorination (1)
- Fluorophilic interactions (1)
- Fluxomics (1)
- Folic acid (1)
- Food Analysis (1)
- Food contaminants (1)
- Food fermentation (1)
- Food safety (1)
- Formulation additives (1)
- Fow injection analysis (1)
- Fracture (1)
- Fragmentation activation (1)
- Fundamentals (1)
- Fungicide (1)
- Fusarium (1)
- Fusarium mycotoxin (1)
- GD-MS (1)
- GF-MAS (1)
- GMAW (1)
- Gadofosveset (1)
- Gadolinium-based contrast agent (1)
- Gadolinium-based contrast agents (GBCAs) (1)
- Gadovist (1)
- Gas analysis (1)
- Gated hybrid material (1)
- General Chemistry (1)
- General Medicine (1)
- Genetics (1)
- Geochemistry (1)
- Geochemistry and Petrology (1)
- Geological material (1)
- Geophysics (1)
- Germanium chlorides (1)
- Germanium sulfide (1)
- Gerätekommunikation (1)
- Gilding (1)
- Github (1)
- Glass Support (1)
- Glucose (1)
- Glycosaminoglycan (1)
- Gold (1)
- Gold nanoparticles (1)
- Graphit (1)
- Greek curse tablets (1)
- Group profile (1)
- HERFD-XAS (1)
- HF free Digestion (1)
- HLA (1)
- HPLC-DAD/FLD (1)
- HPLC-ICP-MS (1)
- HPLC-MS (1)
- HPLC–MS (1)
- HR-CS-GFMAS (1)
- HT22 (1)
- HTS (1)
- Harsh environment (1)
- Hay fever (1)
- Hazardous substances (1)
- HeLa (1)
- Heart attack (1)
- Heat flow (1)
- Heavy crude oil (1)
- Heavy metals (1)
- Hepatocellular carcinoma (1)
- HexaHis-Tag (1)
- Hierarchical cluster analysis (1)
- High pH (1)
- High pressure experiments (1)
- High purity (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-fired gypsum mortar (1)
- High-frequency arc discharge (1)
- High-purity elements (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- High-resolution continuum source molecular absorption spectrometry (1)
- High-resolution mass spectrometry (1)
- High-resolution synchrotron XRF (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Histology (1)
- Hormone (1)
- Host–guest systems (1)
- Hot electrons (1)
- Hot-pressing (1)
- Human Plasma (1)
- Human papillomavirus (1)
- Hybridization (1)
- Hybridoma (1)
- Hydrated silicate melts (1)
- Hydrochloric acid (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrogen Storage (1)
- Hydrogen adsorption storage (1)
- Hydrogen reduction (1)
- Hydrolysis products (1)
- Hydrolytic resistance (1)
- Hydrothermal fluid (1)
- Hydroxylation (1)
- Hypothalamus (1)
- IC50 (1)
- ICP MS (1)
- ICP-AES (1)
- ICP-MS/MS (1)
- ICP-OES (1)
- ICP-TOF-MS (1)
- ICP-TOFMS (1)
- ICP-ToF-MS (1)
- IDMS (1)
- IMAC purification (1)
- ISO 16000-6 (1)
- ISO REMCO (1)
- Identity (1)
- IgG determination (1)
- IgY (1)
- Iinductively coupled plasma mass spectrometry (1)
- Immunoaffinity extraction (1)
- Immunoassays (1)
- Immunocapture (1)
- Immunofluorescence (1)
- Immunology (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Implant material (1)
- Impurites (1)
- Impurity assessment (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In situ measurement (1)
- In situ studies (1)
- In vitro (1)
- In vivo imaging (1)
- Indirect Hard Modeling (1)
- Indoor air (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inductively coupled plasma mass spectroscopy (1)
- Industrial and Manufacturing Engineering (1)
- Industrial gypsum (1)
- Industry 4.0, (1)
- Inflammation (1)
- Ink analysis (1)
- Inlet ionization (1)
- Inline NMR Spectroscopy (1)
- Inorganic chemical analysis (1)
- Insecticide (1)
- Instrument Communication (1)
- Instrumental isotope fractionation (1)
- Instrumentation (1)
- Integrated Processes (1)
- Interlaboratory key comparison (1)
- Internal standard (1)
- Ion mobility (1)
- Ion mobility spectrometry (1)
- Ionization (1)
- Ionmobility spectrometry (1)
- Ionophore (1)
- Ionophore antibiotics (1)
- Iposomes (1)
- Iridium oxide (1)
- Iron Complex (1)
- Iron disorders (1)
- Iron nanoparticles (1)
- Iron oxide (1)
- Isotope Dilution (1)
- Isotope Labelling (1)
- Isotope amount ratio (1)
- Isotope delta value (1)
- Isotope fractionation (1)
- Isotope-labeled (1)
- Isotopes (1)
- Isotopic analysis (1)
- Isotopic dilution (1)
- Isotopologue Distribution (1)
- Iterative real-time optimization (1)
- Job plot (1)
- Kidney (1)
- Kilogram (1)
- Kinetics (1)
- Kjeldahl (1)
- Kläranlage (1)
- Knowledge representation (1)
- Konjugate (1)
- L-alanine (1)
- LA-(MC-)ICP-MS (1)
- LA-ICP-SFMS (1)
- LA/ICP-MS Imaging (1)
- LC-UV absorbance (1)
- LC/HRMS (1)
- Lab of the Future (1)
- Lab-on-a-Chip (1)
- Lab-on-a-chip (1)
- Labeling (1)
- Labor der Zukunft (1)
- Laboratory 4.0 (1)
- Lactate (1)
- Lacunary Keggin ion (1)
- Ladder sequencing (1)
- Lapis lazuli (1)
- Lasalocid (1)
- Laser (1)
- Laser Ablation (1)
- Laser Doppler vibrometer (1)
- Laser ablation inductively coupled plasma–mass spectrometry imaging (LA-ICP-MSI) (1)
- Laser ablation-inductively coupled plasma-mass spectrometry (1)
- Laser beam welding (1)
- Laser induced breakdown Spectrocopy (LIBS) (1)
- Laser induced plasma (1)
- Laser metal deposition (LMD) (1)
- Lateral flow assay (1)
- Lateral flow test (1)
- Lead ions (1)
- Lead isotope composition (1)
- Lead isotopes (1)
- Lebensmittel (1)
- Legacy pollution (1)
- Library (1)
- Ligand design (1)
- Ligands (1)
- Light chain (1)
- Limit of detection (1)
- Lipid metabolism (1)
- Lipids (1)
- Liver X receptor (1)
- Low energy electrons (1)
- Low-energy electrons (1)
- Luminescence lifetime (1)
- Luminol (1)
- Lung cancer (1)
- Lymnaea stagnalis (1)
- Lysergic acid hydrazide (1)
- Lysosome (1)
- MALDI Imaging MS (1)
- MALDI-ToF-MS (1)
- MAS NMR spectroscopy (1)
- MC-TIMS (1)
- MCC (1)
- MICAP-MS (1)
- MOF (1)
- MOSH/MOAH (1)
- MR Angiography (1)
- MR imaging (1)
- MS/MS (1)
- Macrocycles (1)
- Macrophagen (1)
- Magnesium (1)
- Magnesium isotope ratios (1)
- Magnetic nanocatalyst (1)
- Magnetically stabilized (1)
- Maia detector (1)
- Maillard reaction (1)
- Mass contents (1)
- Mass cytometry (1)
- Mass-spectrometry (1)
- Material Science (1)
- Materials science and engineering (1)
- Matrices (1)
- Matrix independent calibration (1)
- Matrix-assisted laser desorption ionization–mass spectrometry imaging (MALDI-MSI) (1)
- Matrixeffekte (1)
- Measuremment uncertainty (1)
- Mechanism (1)
- Mechanochemical synthesis (1)
- Medicinal application (1)
- MefHySto (1)
- Melanoidin (1)
- Melanoidine (1)
- Mercury speciation (1)
- Mesoporous materials (1)
- Mesoporous particles (1)
- Mesoporous silica (1)
- Messunsicherheit (1)
- Metabolic Flux (1)
- Metabolism (1)
- Metabolization (1)
- Metal nanoclusters (1)
- Metal nanoparticles (1)
- Metal toxicity (1)
- Metal uptake (1)
- Metalloprotein (1)
- Metal−organic frameworks (1)
- Metformin (1)
- Methylmercury (1)
- Metrology in Chemistry (1)
- Metrology in chemistry (1)
- Micro-Hydrocyclone (1)
- Micro-XRF (1)
- Micro-sublimation (1)
- Microbe interactions (1)
- Microbial proteomics (1)
- Microdialysis (1)
- Microdroplet generator (1)
- Microemulsion (1)
- Microfluidic Chip (1)
- Microfluidic system (1)
- Microfluidics (1)
- Microfluids (1)
- Microparticles (1)
- Microplastic analysis (1)
- Microplastic pathways (1)
- Microplastic-induced effects (1)
- Microplastics analytic (1)
- Microplatic (1)
- Microscopy (1)
- Microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) (1)
- Mikroplastik (1)
- Mikroplastik Massegehalt (1)
- Mineral oil hydrocarobons (1)
- Miniaturization (1)
- Missing wedge (1)
- Mixed ink (1)
- Mixture toxicity (1)
- Mobile analysis (1)
- Mobile analytics (1)
- Model (1)
- Modelling (1)
- Modified mycotoxins (1)
- Modifier adaptation (1)
- Moisture measurements (1)
- Mole (1)
- Molecular Biology (1)
- Molecular analysis (1)
- Molecular dynamics simulations (1)
- Molecular emission (1)
- Molecular imaging (1)
- Molecular imprinted polymers (1)
- Molecular imprinting (1)
- Molecular marker (1)
- Molecular recognition (1)
- Molecular spectra (1)
- Molecular-MRI (1)
- Molecule (1)
- Monensin (1)
- Monitoring (1)
- Monoclonal Antibodies (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monoclonal antibody (1)
- Monolith (1)
- Monolithic column (1)
- Monoterpene (1)
- Moxidectin (1)
- Mud volcanoe fluids (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multi-element analysis (1)
- Multiple sclerosis (1)
- Multiple-injection sample-standard bracketing (1)
- Multiplexing (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- Multivariate analysis (1)
- Mycotoxin Analysis (1)
- Müllverbrennung (1)
- NIR (1)
- NIR Spectroscopy (1)
- NIR emitter (1)
- NIR spectroscopy (1)
- NIR-II (1)
- NIST (1)
- NIST-mAb 8671 (1)
- NMR (1)
- NMR Spectroscopy (1)
- NMR spectroscopy (1)
- Nano-carrier (1)
- Nanocluster (1)
- Nanomaterial (1)
- Nanoparticle characterization (1)
- Nanoparticles with same nominal diameter (1)
- Nanoplatelet (1)
- Naphthalene (Nap) (1)
- Near edge X-ray absorption fine structure spectroscopy (1)
- Near-infrared refectography (1)
- Network (1)
- Neural network (1)
- Nickel chelate (1)
- Nile Red (1)
- Nitration (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Nitrogen plasma (1)
- Non-destructive testing (1)
- Non-metal analysis (1)
- Non-targeted analysis (1)
- Nondestructive testing (1)
- Nondestructive testing techniques (1)
- Nontarget analysis (1)
- Nuclear Magnetic Resonance Spectroscopy (1)
- Nuclear magnetic resonance spectroscopy (1)
- Nuclear receptor (1)
- Nucleocapsid (1)
- OECD (1)
- Oberflächenwasser (1)
- Ochratoxin A (1)
- On-line CE/MC-ICP-MS (1)
- On-site detection (1)
- Online NMR Spectroscopy (1)
- Online biosensor (1)
- Ontology (1)
- Open Science (1)
- Open science (1)
- Optical detection (1)
- Optical emission spectroscopy (1)
- Optical sensor (1)
- Orbitrap (1)
- Ore provenance (1)
- Organic Synthesis (1)
- Organic calibration solution (1)
- Organic contaminants (1)
- Outdoor odor emissions (1)
- Oxidative metabolism (1)
- Oxygen evolution reaction (1)
- Oxygen isotope ratios (1)
- P-aminothiophenol (1)
- PAH (1)
- PAHs (1)
- PEG (1)
- PGAA (1)
- PIC technology (1)
- PIXE (1)
- PLS regression (1)
- PXRD (1)
- Papyrus (1)
- Partial Least Squares Regression (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle size distribution (1)
- Pattern recognition receptor (1)
- Pb isotopes (1)
- Peptide (1)
- Peptide library screening (1)
- Peptide losses (1)
- Peptide mass fingerprinting (1)
- Peptides (1)
- Peptides and Proteins (1)
- Per- and Polyfluoroalkyl substances (PFAS) (1)
- Per- and polyfluorinated alkly substances (PFASs) (1)
- Per- and polyfluorinated alkyl substances (PFASs) (1)
- Per- and polyfluoroalkyl substances (PFAS) (1)
- Peristaltic pumps (1)
- Peroxidase (1)
- Ph (1)
- Pharmaceutical (1)
- Pharmaceutical Science (1)
- Pharmazeutika (1)
- Phase field method (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phospholipids (1)
- Phosphonate esters (1)
- Phosphor (1)
- Photocatalysis (1)
- Photochemistry (1)
- Photodynamische Inaktivierung (1)
- Photokatalyse (1)
- Photonic biosensor (1)
- Photooxidation (1)
- Photophysics (1)
- Photosensibilisator (1)
- Photosensitization (1)
- Phthalocyanin (1)
- Physical and theoretical chemistry (1)
- Physical twin (1)
- Phytoliths (1)
- Pigment analyses (1)
- Pilot comparison (1)
- Plant tissue (1)
- Plant-model mismatch (1)
- Plasma induced luminescence (1)
- Plasmaspectrochemistry (1)
- Plastic bottles (1)
- Point of inflection (1)
- Polarised light microscopy (1)
- Polishing (1)
- Pollen extract (1)
- Pollen grains (1)
- Pollution (1)
- Polyclonal Antibodies (1)
- Polycyclic aromatic hydrocarbons (1)
- Polyethylenimine (1)
- Polymer blends (1)
- Polymer membrane (1)
- Polymer particle (1)
- Polymers (1)
- Polymorphs (1)
- Polyoxometalates (1)
- Polyurethanes (1)
- Pore fluids (1)
- Porphyrin (1)
- Portland cement (1)
- Portland clinker (1)
- Priam's treasure (1)
- Primary difference measurement method (PDM) (1)
- Primary transfer standards (PTSs) (1)
- Principal component analysis (1)
- Principal component analysis (PCA) (1)
- Priority effect (1)
- Probenvorbereitung (1)
- Process Industry (1)
- Process control (1)
- Process industry (1)
- Process intelligence (1)
- Production (1)
- Proficiency testing (1)
- Programmed cell death (1)
- Prostate cancer (1)
- Protein (1)
- Protein A (1)
- Protein Purification (1)
- Protein analysis (1)
- Protein content (1)
- Protein hydrolysis (1)
- Protein imaging (1)
- Protein nitration (1)
- Protein oligomerization (1)
- Protein quantification (1)
- Protein test (1)
- Provenance (1)
- Provenance studies (1)
- Provenancing (1)
- Pt-based drugs (1)
- PtNP (1)
- Pulsed-GD-SFMS (1)
- Pulverization (1)
- Pyrethroid (1)
- Pyrolysis (1)
- QC (1)
- Quality Assurance (1)
- Quality Control (1)
- Qualitätskontrolle (1)
- Quantitative bioimaging (1)
- Quantitative determination (1)
- Quantum dots (1)
- Quantum rod (1)
- Quick-XAS (1)
- RBD (1)
- RSSI Received Signal Strength Indicator (1)
- RXES (1)
- Raman microspectroscopy (1)
- Raman spectroscopy (1)
- Rat/human liver microsomes (1)
- Rational design (1)
- Reaction Monitoring (1)
- Reactor control (1)
- Real-time imaging (1)
- Real-time quality control (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Recovery (1)
- Reference (1)
- Reference Material (1)
- Reference Materials (1)
- Reference measurements (1)
- Referenzmaterial (1)
- Refractory alloys (1)
- Regeneration (1)
- Region of interest (1)
- Remediation (1)
- Renal disease (1)
- Renewable Energy (1)
- Research Data Infrastructure (1)
- Research Data Management (1)
- Resonance wavelength shift (1)
- Reversible covalent hydrazine chemistry (RCHC) (1)
- Revision of the SI (1)
- Rhizopus (1)
- Rhizopus and Aspergillus oryzae (1)
- Rhodamine (1)
- Ring resonator (1)
- River (1)
- River water sulfate (1)
- Robustness (1)
- Round robin exercise (1)
- Round robin test (1)
- SBA-16 (1)
- SC-ICP-MS (1)
- SDHI-fungicide (1)
- SI Traceability (1)
- SI-traceability (1)
- SIDA-LC-MS/MS (1)
- SOM-SM (1)
- SPM (1)
- SPR (1)
- Safety (1)
- Salinomycin (1)
- Sample preparation (1)
- Sample treatment (1)
- Sample-sample bracketing (1)
- Sampling (1)
- Sampling techniques (1)
- Sapphire (1)
- Scale anchor (1)
- Screening method (1)
- Seawater (1)
- Secondary alcohols (1)
- Sediment (1)
- Sedimentation box (SB) (1)
- Selenium (1)
- Self-assembly (1)
- Self-healing (1)
- Semantic data integration (1)
- Semantic interoperability (1)
- Semiconductor nanocrystals (1)
- Semiconductor quantum dot (1)
- Sensing (1)
- Sensor network (1)
- Sensors (1)
- Sequence coverage (1)
- Sequence dependence (1)
- Sequencing (1)
- Sers (1)
- Serum (1)
- Sewage sludge (1)
- Sewage treatment plant (1)
- Signal enhancement (1)
- Silanization (1)
- Silbernanopartikel (1)
- Silica diagenesis (1)
- Silicon (1)
- Silicon chlorides (1)
- Silicon isotopes (1)
- Silver nanoparticles (1)
- Single Cell (1)
- Single cell (1)
- Single cell analysis (1)
- Single cell-ICP-MS (1)
- Single-cell analysis (1)
- Sintered Material (1)
- Sintering (1)
- Slags (1)
- Smart Sensors (1)
- Smart sensors (1)
- Smart test laboratories (1)
- Smartphone readout device (1)
- Society of hair testing (1)
- Soda-lime glass (1)
- Soft-templated mesoporous films (1)
- Software (1)
- Soil available boron (1)
- Soils (1)
- Solid phase extraction (SPE) (1)
- Solid state NMR (1)
- Solid-liquid extraction (1)
- Solid-phase extraction (1)
- Solvent-free (1)
- Solvents (1)
- Sonochemical synthesis (1)
- Sorghum (1)
- Spark plasma sintering (1)
- Special issue, young analytical scientists (1)
- Speciation analysis (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrometer (1)
- Spectrometry (1)
- Speroid (1)
- Spheroid (1)
- Spike protein (1)
- Spinel (1)
- Sputtering (1)
- Sr and Nd isotope analysis (1)
- Sr isotope analysis (1)
- Stability (1)
- Stable isotopes (1)
- Stakeholders (1)
- Standards (1)
- Static Mixing (1)
- Statistical analysis (1)
- Steel (1)
- Strain identification (1)
- Strontium isotope (1)
- Structural Biology (1)
- Structural Health Monitoring (1)
- Sulfur isotopes (1)
- Sulphur isotope (1)
- Sum Parameter (1)
- Sum Parameter Method (1)
- Sum parameter (1)
- Sum parameter method (1)
- Supramolecular chemistry (1)
- Surface chemistry (1)
- Surface coating (1)
- Surface modification (1)
- Surface waters (1)
- Surface-plasmon resonance (1)
- Suspended particulate matter (SPM) (1)
- Sustainability and the Environment (1)
- Sustainable Food Safety (1)
- Sustainable Production (1)
- Suzuki coupling (1)
- Synchrotron FTIR (1)
- Synthetic peptides (1)
- TD-GC-MS (1)
- TED-GC-MS (1)
- TGA-MS (1)
- TXRF-XAS (1)
- Tag (1)
- Tandem MS (1)
- Tantalum oxyfluorides (1)
- Target (1)
- Tattoo inks (1)
- Tau (1)
- Terephthalic acid (1)
- Terrorism (1)
- Tesserae (1)
- Test midpoint (1)
- Test strips (1)
- Tetramethylammonium hydroxide (1)
- The MOUSE (1)
- Therapeutic Antibodies (1)
- Therapeutic Drug Monitoring (1)
- Thermal analysis (1)
- Thermal conductivity device (1)
- Thermal decomposition (1)
- Thermal degradation (1)
- Thermal desorption (1)
- Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS), monitoring (1)
- Thermal extraction-desorption gas chromatography mass spectrometry (1)
- Thermal model (1)
- Thermo-desorption (1)
- Thermoplastic (1)
- Thin tissue sections (1)
- Time of flight (1)
- Tire Wear (1)
- Tire particles (1)
- Tissue (1)
- Tissue soldering (1)
- Titanium hydride (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Total cyanide (1)
- Total element content (1)
- Total element determination (1)
- Toxic metals (1)
- Toxicity (1)
- Toxicity testing (1)
- Toxikologie (1)
- Toys (1)
- Trace Analysis (1)
- Trace humdity measurement (1)
- Transesterification (1)
- Transferrin (1)
- Transformationsprodukte (1)
- Transient signal (1)
- Trojan silver artefacts (1)
- Truffle (1)
- Truffle Aroma (1)
- Tryptic digest (1)
- Tryptophan (1)
- Tuber melanosporum (1)
- Two-dimensional off-line coupling (1)
- Two-phase system (1)
- Type-I pyrethroids (1)
- UV Bestrahlung (1)
- UV irradiation (1)
- Ultrasensitive (1)
- Ultrasound (1)
- Urban (1)
- Urine (1)
- VO (1)
- Vacuum ionization (1)
- Vacuum ultraviolet (VUV) light (1)
- Validation trial (1)
- Validierung (1)
- Vanadium (1)
- Vanadium redox flow battery (1)
- Vegetable edible oil (1)
- Veterinary drugs (1)
- Viscosity (1)
- Visualization (1)
- Volatile marker (1)
- Volatile organic compounds; (1)
- Volatiles (1)
- WWTP (1)
- Wasser (1)
- Water analysis (1)
- Water stable isotope analysis (1)
- Whole water samples (1)
- Workflow (1)
- X-Ray Fluorescence (1)
- X-ray absorption spectroscopy (1)
- X-ray fluorescence spectroscopy (1)
- X-ray fuorescence (1)
- XANES spectroscopy (1)
- XAS (1)
- XRCD method (1)
- Xerogel (1)
- Yerba mate tea (1)
- ZIF-8 (1)
- Zearalenone (1)
- Zearalenone sulfate (1)
- Zebrafisch (1)
- Zenodo (1)
- Zinc (1)
- Zinc analysis (1)
- Zirconium (1)
- Zn (1)
- Zyklisierung (1)
- a-zearalenol (1)
- aRTist (1)
- battery aging mechanism (1)
- bell pepper (1)
- boron (1)
- current collector corrosion (1)
- delta value (1)
- depth profiles (1)
- ion optics (1)
- isotope fractionation (1)
- lank characterization (1)
- magnetic nanocatalysts (1)
- measurement uncertainty (1)
- metabolism (1)
- microstructural changes (1)
- openBIS (1)
- p-Aminothiophenol (1)
- p-Nitrothiophenol (1)
- pH sensor (1)
- pL-droplets (1)
- silicon (1)
- spICP-MS (1)
- species-specific isotope information (1)
- tandard addition (1)
- Ägyptisches Museum Berlin (1)
- β-lactam (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (288)
- 1.1 Anorganische Spurenanalytik (106)
- 6 Materialchemie (71)
- 1.7 Organische Spuren- und Lebensmittelanalytik (69)
- 6.3 Strukturanalytik (51)
- 1.8 Umweltanalytik (40)
- 1.4 Prozessanalytik (27)
- 1.6 Anorganische Referenzmaterialien (27)
- 1.5 Proteinanalytik (26)
- P Präsident (22)
Paper des Monats
- ja (7)
The combination of acoustically levitated droplets, mid-IR laser evaporation, and subsequent post-ionization by secondary electrospray ionization was applied for monitoring the enzymatic digestion of various proteins. Acoustically levitated droplets are an ideal, wall-free model reactor, readily allowing compartmentalized microfluidic trypsin digestions. Time-resolved interrogation of the droplets yielded real-time information on the progress of the reaction and thus provided insights into reaction kinetics. After 30 min of digestion in the acoustic levitator, the obtained protein sequence coverages were identical to the reference overnight digestions. Importantly, our results clearly demonstrate that the applied experimental setup can be used for the real-time investigation of chemical reactions. Furthermore, the described methodology only uses a fraction of the typically applied amounts of solvent, analyte, and trypsin. Thus, the results exemplify the use of acoustic levitation as a green analytical chemistry alternative to the currently used batch reactions.
This paper discusses the feasibility of a novel strategy based on the combination of bioprinting nano-doping technology and laser ablation-inductively coupled plasma time-of-flight mass spectrometry analysis for the preparation and characterization of gelatin- based multi-element calibration standards suitable for quantitative imaging. To achieve this, lanthanide up-conversion nanoparticles were added to a gelatin matrix to produce the bioprinted calibration standards. The features of this bioprinting approach were com- pared with manual cryosectioning standard preparation, in terms of throughput, between batch repeatability and elemental signal homogeneity at 5 μm spatial resolution. By using bioprinting, the between batch variability for three independent standards of the same concentration of 89 Y (range 0–600 mg/kg) was reduced to 5% compared to up to 27% for cryosectioning. On this basis, the relative standard deviation ( RSD ) obtained between three independent calibration slopes measured within 1 day also reduced from 16% (using cryosectioning ) to 5% (using bioprinting), supporting the use of a single standard preparation replicate for each of the concentrations to achieve good calibration performance using bioprinting. This helped reduce the analysis time by approximately 3-fold. With cryosectioning each standard was prepared and sectioned individually, whereas using bio-printing it was possible to have up to six different standards printed simultaneously, reducing the preparation time from approximately 2 h to under 20 min (by approxi- mately 6-fold). The bio-printed calibration standards were found stable for a period of 2 months when stored at ambient temperature and in the dark.
This study shows remarkably different features between the oxidation of secondary and primary C₃-C₅ alcohols. The oxidation of primary alcohols is controlled by the oxidative removal of blocking adsorbates, such as CO, formed after the dissociative adsorption of alcohol molecules. Conversely, secondary alcohols do not undergo dissociative adsorption and therefore their oxidation is purely controlled by the energetics of the elementary reaction steps. In this respect, a different role of ruthenium is revealed for the electrooxidation of primary and secondary alcohols on bimetallic platinum-ruthenium catalysts. Ruthenium enhances the oxidation of primary alcohols via the established bifunctional mechanism, in which the adsorption of (hydr)oxide species that are necessary to remove the blocking adsorbates is favored. In contrast, the oxidation of secondary alcohols is enhanced by the Ru-assisted stabilization of an O-bound intermediate that is involved in the potential-limiting step. This alternative pathway enables the oxidation of secondary alcohols close to the equilibrium potential.
This work aimed to evaluate high-resolution continuum source molecular absorption spectrometry (HR-CS MAS), traditionally used to determine non-metals, for the determination of a new element, metal, vanadium. VO was selected as a target molecule because it is relatively stable and was expected to be spontaneously generated in a flame or a graphite furnace (GF). The high-resolution overview spectra of the molecule were obtained in a wide range of 480–630 nm, and absorption due to the X4Σ−–C4Σ− electronic transition was registered. A unique instrumental setup, comprising a prototype Modular Simultaneous Echelle Spectrograph (MOSES) and a commercial HR-CS MAS apparatus, was applied in the research. Finally, the spectral area centered at 550.6230 nm was selected for analysis. A method was developed to determine V in solutions of catalysts of heavy petroleum oil hydroprocessing using a commercial HR-CS spectrometer in a flame version. Although sensitivity was relatively poor (characteristic concentration 380 mg L−1), an extremely low noise enabled reaching a satisfactory detection limit (20 mg L−1 in solution, i.e. 0.1% m:m in the catalyst). For the first time vanadium was determined using ordinary air-acetylene flame. The obtained results were consistent with the results of atomic absorption spectrometry with N2O-C2H2 flame. Unfortunately, only a small population of VO molecules could have been generated in GF measurements. Furthermore, the observed VO molecules appeared only at unfavorably high temperatures. The work shows the potential of HR-CS MAS as a scientific tool for investigating the mechanism of processes occurring in the GF. This work can inspire other research of new analytes for HR-CS MAS.
Cryoadsorption on the inner surface of porous materials is a promising solution for safe, fast, and reversible hydrogen storage. Within the class of highly porous metal−organic frameworks, zeolitic imidazolate frameworks (ZIFs) show high thermal, chemical, and mechanical stability. In this study, we selected ZIF-8 synthesized mechanochemically by twin-screw extrusion as powder and pellets. The hydrogen storage capacity at 77 K and up to 100 bar has been analyzed in two laboratories applying three different measurement setups showing a high reproducibility. Pelletizing ZIF-8 increases the packing density close to the corresponding value for a single crystal without loss of porosity, resulting in an improved volumetric hydrogen storage capacity close to the upper limit for a single crystal. The high volumetric uptake combined with a low and constant heat of adsorption provides ca. 31 g of usable hydrogen per liter of pellet assuming a temperature−pressure swing adsorption process between 77 K − 100 bar and 117 K − 5 bar. Cycling experiments do not indicate any degradation in storage capacity. The excellent stability during preparation, handling, and operation of ZIF-8 pellets demonstrates its potential as a robust adsorbent material for technical application in pilot- and full-scale adsorption vessel prototypes.
The 18O/16O ratio of cherts (δ18Ochert) increases nearly monotonically by ~15‰ from the Archean to present. Two end-member explanations have emerged: cooling seawater temperature (TSW) and increasing seawater δ18O (δ18Osw). Yet despite decades of work, there is no consensus, leading some to view the δ18Ochert record as pervasively altered.
Here, we demonstrate that cherts are a robust archive of diagenetic temperatures, despite metamorphism and exposure to meteoric fluids, and show that the timing and temperature of quartz precipitation and thus δ18Ochert are determined by the kinetics of silica diagenesis. A diagenetic model shows that δ18Ochert is influenced by heat flow through the sediment column. Heat flow has decreased over time as planetary heat is dissipated, and reasonable Archean-modern heat flow changes account for ~5‰ of the increase in δ18Ochert, obviating the need for extreme TSW or δ18Osw reconstructions. The seawater oxygen isotope budget is also influenced by solid Earth cooling, with a recent reconstruction placing Archean δ18OSW 5 to 10‰ lower than today. Together, this provides an internally consistent view of the δ18Ochert record as driven by solid Earth cooling over billion-year timescales that is compatible with Precambrian glaciations and biological.
In recent years, thermoextraction/desorption-gas chromatography/mass spectrometry (TED-GC/MS) has been developed as a rapid detection method for the determination of microplastics (MP) mass contents in numerous environmentally relevant matrices and, in particular, for the measurement of polymers in water samples without time-consuming sample preparation. The TED-GC/MS method was applied to investigate a typical European municipal wastewater system for possible MP masses. Such investigations are important in view of the recent revision of the Urban Wastewater Treatment Directive. Four different representative sampling sites were selected: greywater (domestic wastewater without toilet), combined sewer, and influent and effluent of a wastewater treatment plant (WWTP). All samples were collected by fractional filtration. Filtration was carried out over mesh sizes of 500, 100, 50, and in some cases, 5 µm. Polyethylene (PE), polypropylene (PP), and polystyrene (PS) were detected in all samples, with the PE fraction dominating in all cases. Styrene-butadiene rubber which serves as an indication of tire abrasion, was only found in the influent of the WWTP. The highest MP mass contents were found in the combined sewer, so MP can become a source of pollution during heavy rain events when the capacity limits of the effluent are reached, and the polluted effluent is released uncontrolled into the environment. Based on the studies, MP retention from the WWTP could be estimated to be approximately 96%. Few trends in polymer type or mass contents were detected within the different fractions of the samples or when comparing samples to each other.
A certain group of mycotoxins, the ergot alkaloids, has caused countless deaths throughout human history. They are found in rye and other cereals and ingesting contaminated foods can cause serious health problems. To identify contaminated food exceeding the legal limits for ergot alkaloids, a portable and cost-effective test system is of great interest to the food industry. Rapid analysis can be achieved by screening for a marker compound, for which we chose ergometrine. We developed a magnetic bead-based immunoassay for ergometrine with amperometric detection in a flow injection system using a handheld potentiostat and a smartphone. With this assay a limit of detection of 3 nM (1 μg/L) was achieved. In spiked rye flour, ergometrine levels from 25 to 250 μg/kg could be quantified. All results could be verified by optical detection. The developed assay offers great promise to meet the demand for on-site ergometrine detection in the food industry.
The composition of acoustically levitated droplets was probed by a novel combination of mid-IR laser evaporation and subsequent postionization via secondary electrospray ionization. The combination of microliter samples and subnanoliter sampling provided time-resolved interrogation of droplets and allowed for a kinetic investigation of the laser-induced release of the analyte, which was found to strongly depend on the analytes. The observed substancespecific delayed release of the analytes permitted baseline-separated discrimination of the analytes, ideal for the study of complex samples.
The additionally applied postionization scheme was found to enable efficient detection of small volatile compounds as well as peptides. The detection of small molecules and peptides occurred under very different sampling geometries, pointing to two distinct underlying ionization mechanisms. Overall, our results suggest that the experimental setup presented in this study can serve as a widely applicable platform to study chemical reactions in acoustically levitated droplets as model reactors.
Living organisms constantly interact with their environment, including through the exchange of gases. Respiration and the release and uptake of volatile organic compounds (VOCs) create dynamic microenvironments in biological systems. Studying the kinetics of volatiles in biological systems requires expensive instruments, and data analysis is challenging. Therefore, we aimed to design a minimal analytical device for measuring the composition of gaseous mixtures in realtime.
We built the ‘Modular Biological Mass Spectrometer’ (MoBiMS) from 3D-printed parts and custom sensors to fit a wide array of experimental set-ups. We tested the chemical detection range and temporal resolution of the MoBiMS employing pure compounds and complex biological samples.
Compounds with a higher than 0.4 mmHg vapor pressure and a molecular weight up to 154 g/mol were reliably sensed within seconds. The generated electron impact (EI) spectra were directly comparable with standard databases like the NIST EI library. Under a direct analysis approach, the MoBiMS identified the characteristic odor of banana (Musa sp.), that is, isoamyl acetate; tracked the dynamics of CO2 release while the Alka-Seltzer® reaction occurred showed the kinetics of the transient production and consumption of carbon dioxide during photosynthesis. MoBiMS also discriminated between volatile compounds ions coming from tobacco (Nicotiana benthamiana) leaves and the surrounding air through untargeted analysis. The small footprint of the MoBiMS and its relatively low energy consumption facilitate in situ analyses, as an additional gas supply is not necessary with EI ionization. The MoBiMS is easy to assemble, and its construction and operation are very cost-efficient compared to commercial devices. The analytical performance of the MoBiMS is suitable for real-time studies of biological systems, environmental monitoring, and medical diagnostics.
Estrogens are endocrine disrupting chemicals and of high concerns due to demonstrated harmful effects on the environment and low effect levels. For monitoring and risk assessment, several estrogens were included in the "watch list" of the EU Water Framework Directive which sets very low environmental quality standard (EQS) levels for Estrone (E1) and 17β-Estradiol (E2) of 0.4 ng L−1 and for 17α-Ethinylestradiol (EE2) of 0.035 ng L−1 requiring sensitive detection methods, as well as extensive sample preparation. A sensitive, derivatization-free, isotope dilution calibration HPLC-MS/MS method for a panel of 5 selected estrogens (including the 3 estrogens of the EU WFD watchlist), and a procedure for the reproducible preparation of a representative whole water matrix including mineral water, humic acids and solid particulate matter are presented. These are used in a diligent comparison of classical solid phase extraction (SPE) on hydrophilic-lipophilic balanced (HLB) phase to SPE on an estrogen-specific molecularly imprinted polymer phase (MISPE) for ultra-trace levels of the analytes (1–10 ng L−1). Additionally, a two-step procedure combining HLB SPE disks followed by MISPE is evaluated. The tow-step procedure provides superior enrichment, matrix removal and sample throughput while maintaining comparable recovery rates to simple cartridge SPE. Estimated method quantification limits (MQLs) range from 0.109–0.184 ng L−1 and thus meet EQS-levels for E1 and E2, but not EE2. The representative whole water matrix provides a reproducible comparison of sample preparation methods and lays the foundation for a certified reference material for estrogen analysis. The presented method will serve as the basis for an extended validation study to assess its use for estrogen monitoring in the environment.
X-ray fluorescence imaging is a well-established tool in materials characterization. In this work, we present the adaption of coded aperture imaging to full-field X-ray fluorescence imaging at the synchrotron. Coded aperture imaging has its origins in astrophysics, and has several advantages: Coded apertures are relatively easy to fabricate, achromatic, allow a high photon throughput, and high angular acceptance. Coded aperture imaging is a two-step-process, consisting of the measurement process and a reconstruction step. Different programs have been written, for the raytracing/forward projection and the reconstruction. Experiments with coded aperture in combination with a Color X-ray Camera and an energy-dispersive area detector, have been conducted at the BAMline. Measured samples were successfully reconstructed, and gave a 9.1-fold increase in count rate compared to a polycapillary optic.
n this study, two green synthesis routes were used for the synthesis of Ag/ZnO nanoparticles, using cassava starch as a simple and low-cost effective fuel and Aloe vera as a reducing and stabilizing agent. The Ag/ZnO nanoparticles were characterized and used for bacterial dis-
infection of lake water contaminated with Escherichia coli (E. coli). Characterization indicated the formation of a face-centered cubic structure of metallic silver nanoparticles with no insertion of Ag into the ZnO hexagonal wurtzite structure. Physicochemical and bacteriological analyses described in “Standard Methods for the Examination of Water and Wastewater” were used to evaluate the efficiency of the treatment. In comparison to pure ZnO, the synthesized Ag/ZnO nanoparticles showed high efficiencies against Escherichia coli (E. coli) and general coliforms present in the lake
water. These pathogens were absent after treatment using Ag/ZnO nanoparticles. The results indicate that Ag/ZnO nanoparticles synthesized via green chemistry are a promising candidate for the treatment of wastewaters contaminated by bacteria, due to their facile preparation, low-cost synthesis,and disinfection efficiency.
The most profound consequences of the presence of Ca–Mg carbonates (CaCO3–MgCO3) in the Earth’s upper mantle may be to lower the melting temperatures of the mantle and control the melt composition.
Low-degree partial melting of a carbonate-bearing mantle produces CO2-rich, silica-poor melts compositionally imposed by the melting relations of carbonates. Thus, understanding the melting relations in the CaCO3–MgCO3 system facilitates the interpretation of natural carbonate-bearing silicate systems.
We report the melting relations of the CaCO3–MgCO3 system and the partition coefficient of trace elements between carbonates and carbonate melt from experiments at high pressure (6 and 9 GPa) and temperature (1300–1800 ◦C) using a rocking multi-anvil press. In the absence of water, Ca–Mg carbonates are stable along geothermal gradients typical of subducting slabs. Ca–Mg carbonates (∼ Mg0.1–0.9Ca0.9–0.1CO3) partially melt beneath mid-ocean ridges and in plume settings. Ca–Mg carbonates melt incongruently, forming periclase crystals and carbonate melt between 4 and 9 GPa. Furthermore, we show that the rare earth element (REE) signature of Group-I kimberlites, namely strong REE fractionation and depletion of heavy REE relative to the primitive mantle, is resembled by carbonate melt in equilibrium with Ca-bearing magnesite and periclase at 6 and 9 GPa. This suggests that the dolomite–magnesite join of the CaCO3–MgCO3 system might be useful to approximate the REE signature of carbonate-rich melts parental to kimberlites.
The environmental fate of the frequently used broad-spectrum β-lactam antibiotic amoxicillin (AMX) is of high concern regarding the potential evolution of antimicrobial resistance (AMR). Moreover, it is known that AMX is prone to hydrolysis, yielding a variety of hydrolysis products (HPs) with yet unknown effects. Studies to identify those HPs and investigate their formation mechanisms have been reported but a long-term study on their stability in real water samples was missing. In this regard, we investigated the hydrolysis of AMX at two concentration levels in four distinct water types under three different storage conditions over two months. Concentrations of AMX and four relevant HPs were monitored by an LC-MS/MS method revealing pronounced differences in the hydrolysis rate of AMX in tap water and mineral water on the one hand (fast) and surface water on the other(slow). In this context, the occurrence, relative intensities, and stability of certain HPs are more dependent on the water type than on the storage condition. As clarified by ICP-MS, the main difference between the water types was the content of the metals copper and zinc which are supposed to catalyze AMX hydrolysis demonstrating an effective method to degrade AMX at ambient conditions.
In this study, we employed nitrogen microwave inductively coupled atmospheric-pressure plasma (MICAP) combined with quadrupole mass spectrometry (MS) and a liquid sample introduction system to analyze heavy metals in soils. The vanadium, cobalt, nickel, zinc, copper, chromium, arsenic, lead, and cadmium contents in seven reference and three environmental soil samples determined using MICAP-MS were within the uncertainty of the reference values, indicating that MICAP-MS is promising for soil analysis similar to the conventional inductively coupled plasma mass spectrometry (ICP-MS) technique. In addition, the limits of detection (LODs) and sensitivity of both techniques using N2 and Ar plasma were of the same order of magnitude. Furthermore, the performance of MICAP-MS under different N2 purity was investigated, and we found that the plasma formation and ionization efficiency were not influenced by the impurities in the gas. A prominent advantage of MICAP-MS is the low operating cost associated with gas consumption. In this work, MICAP-MS used nitrogen, which is cheaper than argon, and consumed 25% less gas than ICP-MS. Using low-purity N2 can further reduce the gas cost, making MICAP-MS more cost effective than ICP-MS. These results suggest that MICAP-MS is a promising alternative to ICP-MS for the analysis of heavy metals in the soil.
Despite numerous advantages offered by hyphenation of chromatography and electrokinetic separation methods with multicollector (MC) ICP-MS for isotope analysis, the main limitation of such systems is the decrease in precision and increase in uncertainty due to generation of short transient signals. To minimize this limitation, most authors compare several isotope ratio calculation methods and establish a multi-step data processing routine based on the precision and accuracy of the methods. However, to the best of our knowledge, there is no universal data processing tool available that incorporates all important steps of the treatment of the transient signals. Thus, we introduce a data processing application (App) IsoCor that facilitates automatic calculation of isotope ratios from transient signals and eases selection of the most suitable method. The IsoCor App performs baseline subtraction, peak detection, mass bias correction, isotope ratio calculation and delta calculation. The feasibility and reliability of the App was proven by reproducing the results from isotope analysis of three elements (neodymium, mercury and sulfur) measured on-line via hyphenated systems. The IsoCor App provides trackability of the results to ensure quality control of the analysis.
The aim of this study was to identify specific truffle marker substances within the truffle aroma. The aroma profile of different truffle species was analyzed using static headspace sampling with gas chromatography mass spectrometry analysis (SHS/GC-MS). Possible marker substances were identified, taking the additional literature into account. The selected marker substances were tested in an experiment with 19 truffle dogs. The hypothesis “If trained truffle dogs recognize the substances as supposed truffles in the context of an experiment, they can be regarded as specific” was made. As it would be nearly impossible to investigate every other possible emitter of the same compounds to determine their specificity, this hypothesis was a reasonable approximation. We were interested in the question of what it is the dogs actually search for on a chemical level and whether we can link their ability to find truffles to one or more specific marker substances. The results of the dog experiment are not as unambiguous as could have been expected based on the SHS/GC-MS measurements. Presumably, the truffle aroma is mainly characterized and perceived by dogs by dimethyl sulfide and dimethyl disulfide. However, as dogs are living beings and not analytical instruments, it seems unavoidable that one must live with some degree of uncertainty regarding these results.
Nebivolol (NEB), a β-blocker frequently used to treat cardiovascular diseases, has been widely detected in aquatic environments, and can be degraded under exposure to UV radiation, leading to the formation of certain transformation products (UV-TPs). Thus, the toxic effects of NEB and its UV-TPs on aquatic organisms are of great importance for aquatic ecosystems. In the present study, the degradation pathway of NEB under UV radiation was investigated. Subsequently, zebrafish embryos/larvae were used to assess the median lethal concentration (LC50) of NEB, and to clarify the sub-lethal effects of NEB and its UV-TPs for the first time. It was found that UV radiation could reduce the toxic effects of NEB on the early development of zebrafish. Transcriptomic analysis identified the top 20 enriched Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways in zebrafish larvae exposed to NEB, most of which were associated with the antioxidant, nervous, and immune systems. The number of differentially expressed genes (DEGs) in the pathways were reduced after UV radiation. Furthermore, the analysis of protein biomarkers, including CAT and GST (antioxidant response), AChE and ACh (neurotoxicity), CRP and LYS (immune response), revealed that NEB exposure reduced the activity of these biomarkers, whereas UV radiation could alleviate the effects. The present study provides initial insights into the mechanisms underlying toxic effects of NEB and the detoxification effects of UV radiation on the early development of zebrafish. It highlights the necessity of considering the toxicity of UV-TPs when evaluating the toxicity of emerging pollutants in aquatic systems.
Inflammatory bowel diseases (IBD) comprise mainly ulcerative colitis (UC) and Crohn´s disease (CD). Both forms present with a chronic inflammation of the (gastro) intestinal tract, which induces excessive changes in the composition of the associated extracellular matrix (ECM). In UC, the inflammation is limited to the colon, whereas it can occur throughout the entire gastrointestinal tract in CD. Tools for early diagnosis of IBD are still very limited and highly invasive and measures for standardized evaluation of structural changes are scarce. To investigate an efficient non-invasive way of diagnosing intestinal inflammation and early changes of the ECM, very small superparamagnetic iron oxide nanoparticles (VSOPs) in magnetic resonance imaging (MRI) were applied in two mouse models of experimental colitis: the dextran sulfate sodium (DSS)-induced colitis and the transfer model of colitis. For further validation of ECM changes and inflammation, tissue sections were analyzed by immunohistochemistry. For in depth ex-vivo investigation of VSOPs localization within the tissue, Europium-doped VSOPs served to visualize the contrast agent by imaging mass cytometry (IMC). VSOPs accumulation in the inflamed colon wall of DSS-induced colitis mice was visualized in T2* weighted MRI scans. Components of the ECM, especially the hyaluronic acid content, were found to influence VSOPs binding. Using IMC, colocalization of VSOPs with macrophages and endothelial cells in colon tissue was shown. In contrast to the DSS model, colonic inflammation could not be visualized with VSOP-enhanced MRI in transfer colitis. VSOPs present a potential contrast agent for contrast-enhanced MRI to detect intestinal inflammation in mice at an early stage and in a less invasive manner depending on hyaluronic acid content.
Rapid, cost-efficient, and eco-friendly methods are desired today for routine analysis of the Fusarium mycotoxin zearalenone (ZEN) in edible vegetable oils. Liquid chromatography with fluorescence detection (HPLC-FLD) is commonly used to reliably control the specified ZEN maximum levels, which requires efficient sample clean-up to avoid matrix interferences. Therefore, a highly selective extraction and clean-up method based on reversible covalent hydrazine chemistry (RCHC) using hydrazine-functionalized silica was developed. This efficient solid-phase extraction (SPE) involves reversible hydrazone formation of ZEN with the hydrazine moiety covalently bound to a solid phase. Optimal conditions were achieved with 1 mL SPE cartridges filled with 400 mg of hydrazine-functionalized silica. The developed RCHC-SPE method was validated in an interlaboratory comparison study (ILC) with twelve participants analyzing six edible vegetable oils with a focus on maize oils. The derived method parameters (ZEN recovery 83%, repeatability 7.0%, and reproducibility 18%) meet the performance criteria of Commission Regulation (EC) No 401/2006. The developed RCHC-SPE-based HPLC-FLD method allows the reliable quantification of ZEN in the range of 47–494 μg/kg for different types of edible vegetable oils, also for matrix-reach native oils. Due to the high efficiency, the significantly reduced matrix load helps to extend the lifetime of analytical equipment. Furthermore, the re-useability of the RCHC-SPE cartridges contributes to an eco-friendly approach and reduced analysis costs. To our knowledge, this is the first report on ZEN quantification in edible vegetable oils based on manual RCHC-SPE cartridges. Due to its high performance, the developed RCHC-SPE method is a promising alternative to the current European standard method EN 16924:2017 (HPLC-FLD part).
Lithium and boron are trace components of magmas, released during exsolution of a gas phase during volcanic activity. In this study, we determine the difusivity and isotopic fractionation of Li and B in hydrous silicate melts. Two glasses were synthesized with the same rhyolitic composition (4.2 wt% water), having diferent Li and B contents; these were studied in difusion-couple experiments that were performed using an internally heated pressure vessel, operated at 300 MPa in the temperature range 700–1250 °C for durations from 0 s to 24 h. From this we determined activation energies for Li and B difusion of 57±4 kJ/mol and 152±15 kJ/mol with pre-exponential factors of 1.53 × 10–7 m2/s and 3.80× 10–8 m2 /s, respectively. Lithium isotopic fractionation during difusion gave β values between 0.15 and 0.20, whereas B showed no clear isotopic fractionation. Our Li difusivities and isotopic fractionation results difer somewhat from earlier published values, but overall confrm that Li difusivity increases with water content. Our results on B difusion show that similarly to Li, B mobility increases in the presence of water. By applying the Eyring relation, we confrm that B difusivity is limited by viscous fow in silicate melts. Our results on Li and B difusion present a new tool for understanding degassing-related processes, ofering a potential geospeedometer to measure volcanic ascent rates.
Analysis of electrochemical and liver microsomal transformation products of lasalocid by LC/HRMS
(2022)
Rationale: Lasalocid (LAS), an ionophore, is used in cattle and poultry farming as feed additive for its antibiotic and growth-promoting properties. Literature on transformation products (TP) resulting from LAS degradation is limited. So far, only hydroxylation is found to occur as the metabolic reaction during the LAS degradation. To investigate potential TPs of LAS, we used electrochemistry (EC) and liver microsome (LM) assays to synthesize TPs, which were identified using liquid chromatography high-resolution mass spectrometry (LC/HRMS).
Methods: Electrochemically produced TPs were analyzed online by direct coupling of the electrochemical cell to the electrospray ionization (ESI) source of a Sciex Triple-TOF high resolution mass spectrometer. Then, EC-treated LAS solution was collected and analyzed offline using LC/HRMS to confirm stable TPs and improve their annotation with a chemical structure due to informative MS/MS spectra. In a complementary approach, TPs formed by rat and human microsomal incubation were investigated using LC/HRMS. The resulting data were used to investigate LAS modification reactions and elucidate the chemical structure of obtained TPs.
Results: The online measurements identified a broad variety of TPs, resulting from modification reactions like (de-)hydrogenation, hydration, methylation, oxidation as well as adduct formation with methanol. We consistently observed different ion complexations of LAS and LAS-TPs (Na+; 2Na+ K+; NaNH4 +; KNH4 +). Two stable methylated EC-TPs were found, structurally annotated, and assigned to a likely modification reaction. Using LM incubation, seven TPs were formed, mostly by oxidation/hydroxylation. After the identification of LM-TPs as Na+-complexes, we identified LM-TPs as K+-complexes.
Conclusion: We identified and characterized TPs of LAS using EC- and LM-based methods. Moreover, we found different ion complexes of LAS-based TPs. This knowledge, especially the different ion complexes, may help elucidate the metabolic and environmental degradation pathways of LAS.
Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are critical components of every industrial chemical process as they provide information on the concentrations of individual compounds and by-products. These processes are carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been developed to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra to train an ANN with better prediction performance and speed than state-of-theart analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a possible strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control.
Li-rich nanoparticles of Li1+xMn2–xO4 doped with Al, Co, or Ni are successfully synthesized using a facile, fast, and efficient microwave-assisted hydrothermal route. Synchrotron X-ray diffraction confirms the formation of the crystalline cubic spinel phase type. X-ray absorption spectroscopy analysis at the Co and Ni K- and L-edges verifies that the dopants are within the Li1+xMn2–xO4 spinel structure and are inactive during cycling in the bulk and at the surface. Moreover, we demonstrate that nanocrystallinity and cationic doping play an important role in improving the electrochemical performance with respect to LiMn2O4 microparticles. They significantly reduce the charge-transfer resistance, lower the first cycle irreversible capacity loss to 6%, and achieve a capacity retention between 85 and 90% after 380 cycles, with excellent Coulombic efficiency close to 99% without compromising the specific charge at a 5C cycling rate. Furthermore, the Mn K- and L-edges attest that after long cycling, the Mn oxidation state in the bulk differs from that at the surface caused by the Mn disproportion reaction; however, the cationic doping helps mitigate the Mn dissolution with respect to the undoped Li1+xMn2–xO4 nanoparticles, as indicated by inductively coupled plasma atomic emission spectrometry.
Fire-gilding is a historic technique for the application of golden layers on a number of different base materials utilizing a gold amalgam. This technique leaves a significant amount of Hg in the golden layer, giving archeometrists a reliable indicator to identify firegildings.
Recent findings on presumably fire-gilded objects have shown in several cases significantly lower Hg content than previously studied objects. This prompted a synchrotron-based X-ray fluorescence investigation into the Hg distribution along the material–gilding interface, as well as a series of measurements regarding the Hg content development in fire-gilded samples during artificial aging. This work presents findings on laboratory-prepared fire-gildings, indicating an Hg enrichment at the interface of firegilded silver samples. Notably, such an enrichment is missing in fire-gilded copper samples. Further, it is confirmed that fire-gilded layers typically do not undercut an Hg bulk content of 5%. In this light, it seems improbable that ancient samples that contain <5% Hg are fire-gilded. The results presented in this study might lead to a non-destructive method to identify the Hg enrichment at the interface. This might be obtained by a combination of different non-destructive measurements and might also work unambiguously in samples in which the gold top layer is altered.
EXAFS analysis of pure elements, binary and ternary equiatomic refractory alloys within the Nb-Zr-Ti-Hf- Ta system is performed at the Nb and Zr K-edges to analyze the evolution of the chemical local environ- ment and the lattice distortion. A good mixing of the elements is found at the atomic scale. For some compounds, a distribution of distances between the central atom and its neighbors suggests a distortion of the structure. Finally, analysis of the Debye-Waller parameters shows some correlation with the lat- tice distortion parameter δ², and allows to quantify experimentally the static disorder in medium entropy alloys.
Within this work, the combination of a microdroplet generator and an ICP-ToF-MS for nanoparticle analysis is presented. For the size determination of platinum nanoparticles an on-line isotope dilution analysis approach was developed. The 194Pt/195Pt isotopic ratio was used for the characterization of the particles, while the 182W/183W isotopic ratio was monitored simultaneously for mass bias correction. The on-line ID-MDG-sp-ICP-ToF-MS approach was deployed for the size determination of three platinum nanoparticle samples (50 nm, 63 nm, 70 nm); for validation, complementary size characterization techniques (sp-ICP-ToF-MS and TEM) were used. The robustness of this technique was evidenced, by using sodium chloride concentrations up to 100 mg L−1 as a matrix component. Our new on-line ID MDG-sp-ICP-ToF-MS approach is a promising tool for the fast and reliable determination of nanoparticles' size in severe matrix concentrations, e.g., environmental samples.
Electron microscopy (EM) is the gold standard for the characterisation of the morphology (size and shape) of nanoparticles. Visual observation of objects under examination is always a necessary first step in the characterisation process. Several questions arise when undertaking to identify and count particles to measure their size and shape distribution. In addition to challenges with the dispersion and identification of the particles, more than one protocol for counting particles is in use. This paper focuses on precise rules for the counting of particles in EM micrographs, as this influences the measurement accuracy of the number of particles, thus implicitly affecting the size values of the counted particles. We review and compare four different, commonly used methods for counting, which we then apply in case studies. The impact of the selected counting rule on the obtained final particle size distribution is highlighted. One main aim of this analysis is to support the application of a specific, well-defined counting approach in accordance with regulatory
requirements to contribute to achieving more reliable and reproducible results. It is also useful for the new harmonised measurement procedures for determining the particle size and particle size distribution of nanomaterials.
In this study, carried out within the Joint Danube Survey 4, a comprehensive microplastic screening in the water column within a large European river basin from its source to estuary, including major tributaries, was realized. The objective was to develop principles of a systematic and practicable microplastic monitoring strategy using sedimentation boxes for collection of suspended particulate matter followed by its subsequent analysis using thermal extraction desorption-gas chromatography/mass spectrometry. In total, 18 sampling sites in the Danube River Basin were investigated. The obtained suspended particulate matter samples were subdivided into the fractions of >100 μm and <100 μm and subsequently analyzed for microplastic mass contents. The results showed that microplastics were detected in all samples, with polyethylene being the predominant polymer with maximum contents of 22.24 μg/mg, 3.23 μg/mg for polystyrene, 1.03 μg/mg for styrene-butadiene-rubber, and 0.45 μg/mg for polypropylene. Further, polymers such as different sorts of polyester, polyacrylates, polylactide, and natural rubber were not detected or below the detection limit. Additional investigations on possible interference of polyethylene signals by algae-derived fatty acids were assessed. In the context of targeted monitoring, repeated measurements provide more certainty in the interpretation of the results for the individual sites. Nevertheless, it can be stated that the chosen approach using an integrative sampling and determination of total plastic content proved to be successful.
Boron isotope fractionation in soil-plant systems and its influence on biogeochemical cycling
(2022)
Boron (B) is an essential mineral nutrient for higher plants. Although B plant nutrition is well studied, the B isotope fractionation at the soil-plant interface, within plant metabolism, and its influence on biogeochemical cycling is not fully understood. Boron concentrations and isotope variations (δ11B) of the dicotyledonous plants of Chenopodium album and Brassica napus and their growing soils along a climatic gradient were analyzed to decipher these unresolved issues of the B behavior. The boron concentrations and δ11B values show an increasing trend from roots to leaves for both plants, while a decreasing trend from flower to shell and to seed for Brassica napus. A large boron isotope fractionation occurs within the plants with median Δ11Bleaf-root ≈ +20‰, which is related to different boron transporters and transportation ways. Formation of borate dimerized rhamnogalacturonan II in cell and B(OH)3 transportation in xylem lead to heavier δ11B values from root to stem and leaf while B(OH)4 transportation in phloem lead to lighter δ11B values from flower to shell and seed. Although samples cover a distinct transect with systematically different climatic conditions, Δδ11B within the individual plant compartments and between the bulk plants and the soil available B do not show any systematic variation.
This suggests that B uptake from the soil into Chenopodium album and Brassica napus occurs without a distinct isotope fractionation at the soil-plant interface (median Δ11Bbulkplant-soil = 0.2‰) and plants are able to regulate boron uptake. Both the observed large B fractionation within plant and low or absent B isotope fractionation at the soil-plant interface may have profound implications for the biological and geological B cycle. If this observed boron behavior also exists in other plants, their litters would be an important source for exporting 11B-rich biological material from continental ecosystems via rivers to the global oceans. This may be helpful for the explanation of ocean B cycle and the increasing δ11B values over the Cenozoic.
Prostate cancer (PCa) is one of the most common cancers in men. For detection and diagnosis of PCa, non-invasive methods, including magnetic resonance imaging (MRI), can reduce the risk potential of surgical intervention. To explore the molecular characteristics of the tumor, we investigated the applicability of ferumoxytol in PCa in a xenograft mouse model in two different tumor volumes, 500 mm3 and 1000 mm3. Macrophages play a key role in tumor progression, and they are able to internalize iron-oxide particles, such as ferumoxytol. When evaluating T2*-weighted sequences on MRI, a significant decrease of signal intensity between pre- and post-contrast images for each tumor volume (n = 14; p < 0.001) was measured. We, furthermore, observed a higher signal loss for a tumor volume of 500 mm3 than for 1000 mm3. These findings were confirmed by histological examinations and laser ablation inductively coupled plasma-mass spectrometry. The 500 mm3 tumors had 1.5% iron content (n = 14; sigma = 1.1), while the 1000 mm3 tumors contained only 0.4% iron (n = 14; sigma = 0.2). In vivo MRI data demonstrated a correlation with the ex vivo data (R2 = 0.75). The results of elemental analysis by inductively coupled plasma-mass spectrometry correlated strongly with the MRI data (R2 = 0.83) (n = 4). Due to its long retention time in the blood, biodegradability, and low toxicity to patients, ferumoxytol has great potential as a contrast agent for visualization PCa.
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P216, was coordinated by the Chinese National Institute of Metrology (NIM), National Research Council of Canada (NRC) and the Bureau International des Poids et Mesures (BIPM). Eleven Metrology Institutes or Designated Institutes and the BIPM participated in the first phase of the pilot study (Part 1). The purpose of this pilot study was to develop measurement capabilities for larger proteins using a recombinant humanized IgG monoclonal antibody against Spike glycoprotein of SARS-CoV-2 (Anti-S IgG mAb) in solution. The first phase of the study was designed to employ established methods that had been previously studies by the CCQM Protein Analysis Working Group, involving the digestion of protein down to the peptide or amino acid level. The global coronavirus pandemic has also led to increased focus on antibody quantitation methods. IgG are among the immunoglobulins produced by the immune system to provide protection against SARS-CoV-2. Anti-SARS-CoV-2 IgG can therefore be detected in samples from affected patients. Antibody tests can show whether a person has been exposed to the SARS-CoV-2, and whether or not they potentially show lasting immunity to the disease. With the constant spread of the virus and the high pressure of re-opening economies, antibody testing plays a critical role in the fight against COVID-19 by helping healthcare professionals to identify individuals who have developed an immune response, either via vaccination or exposure to the virus. Many countries have launched large-scale antibody testing for COVID-19. The development of measurement standards for the antibody detection of SARS-CoV-2 is critically important to deal with the challenges of the COVID-19 pandemic. In this study, the SARS-CoV-2 monoclonal antibody is being used as a model system to build capacity in methods that can be used in antibody quantification. Amino acid reference values with corresponding expanded uncertainty of 36.10 ± 1.55 mg/kg, 38.75 ± 1.45 mg/kg, 18.46 ± 0.78 mg/kg, 16.20 ± 0.67 mg/kg and 30.61 ± 1.30 mg/kg have been established for leucine, valine, phenylalanine, isoleucine and proline, respectively. Agreement between nearly all laboratories was achieved for the amino acid analysis within 2 to 2.5 %, with one participant achieving markedly higher results due to a technical issue found in their procedure; this result was thus excluded from the reference value calculations. The relatively good agreement within a laboratory between different amino acids was not dissimilar to previous results for peptides or small proteins, indicating that factors such as hydrolysis conditions and calibration procedures could be the largest sources of variability. Peptide reference values with corresponding expanded uncertainty of 4.99 ± 0.28 mg/kg and 6.83 ± 0.65 mg/kg have been established for ALPAPIEK and GPSVFPLAPSSK, respectively. Not surprisingly due to prior knowledge from previous studies on peptide quantitation, agreement between laboratories for the peptide-based analysis was slightly poorer at 3 to 5 %, with one laboratory's result excluded for the peptide GPSVFPLAPSSK. Again, this level of agreement was not significantly poorer than that achieved in previous studies with smaller or less complex proteins. To reach the main text of this paper, click on Final Report.
Lifestyle modifications could prevent almost one‑third to one‑half of all cancer cases. The awareness of cancer risk factors could motivate people to make such changes in their behaviors and lifestyles. This work aims to investigate the cancer awareness level in the Pakistani population. Telephone interviews of 657 individuals in Pakistan were carried out using the Cancer Awareness Measure (CAM) and Cancer Awareness Measure–MYthical Causes Scale (CAM‑MY). We observed that participants scored significantly better on the CAM scale than the CAM‑MY scale, and CAM scores were negatively associated with CAM‑MY scores. Years of formal education or a biology major at undergraduate or graduate level did not affect our population’s cancer awareness levels. Age displayed a weak but statistically significant negative association with CAM scores. Most participants failed to identify modifiable cancer risk factors, e.g., low physical activity. Efforts should be made to improve awareness of modifiable risk factors. We observed that brief training sessions could markedly improve people’s understanding of cancer risk factors and myths.
For more than 110 years, BAM has been producing reference materials for a wide range of application fields. With the development of new analytical methods and new applications as well as continuously emerging more stringent requirements of laboratory accreditation with regard to quality control and metrological traceability, the demand and requirements for reference materials are increasing. This trend article gives an overview of general developments in the field of reference materials as well as developments in selected fields of application in which BAM is active. This includes inorganic and metal analysis, gas analysis, food and consumer products, and geological samples. In addition to these more traditional fields of application, developments in the areas of optical spectroscopy, particulary fluorescence methods, and nanomaterials are considered.
Towards Unbiased Evaluation of Ionization Performance in LC-HRMS Metabolomics Method Development
(2022)
As metabolomics increasingly finds its way from basic science into applied and regulatory environments, analytical demands on nontargeted mass spectrometric detection methods continue to rise. In addition to improved chemical comprehensiveness, current developments aim at enhanced robustness and repeatability to allow long-term, inter-study, and meta-analyses. Comprehensive metabolomics relies on electrospray ionization (ESI) as the most versatile ionization technique, and recent liquid chromatography-high resolution mass spectrometry (LC-HRMS) instrumentation continues to overcome technical limitations that have hindered the adoption of ESI for applications in the past. Still, developing and standardizing nontargeted ESI methods and instrumental setups remains costly in terms of time and required chemicals, as large panels of metabolite standards are needed to reflect biochemical diversity. In this paper, we investigated in how far a nontargeted pilot experiment, consisting only of a few measurements of a test sample dilution series and comprehensive statistical analysis, can replace conventional targeted evaluation procedures. To examine this potential, two instrumental ESI ion source setups were compared, reflecting a common scenario in practical method development. Two types of feature evaluations were performed, (a) summary statistics solely involving feature intensity values, and (b) analyses additionally including chemical interpretation.
Results were compared in detail to a targeted evaluation of a large metabolite standard panel. We reflect on the advantages and shortcomings of both strategies in the context of current harmonization initiatives in the metabolomics field.
MALDI-TOF-MS-Based Identification of Monoclonal Murine Anti-SARS-CoV-2 Antibodies within One Hour
(2022)
During the SARS-CoV-2 pandemic, many virus-binding monoclonal antibodies have been developed for clinical and diagnostic purposes. This underlines the importance of antibodies as universal bioanalytical reagents. However, little attention is given to the reproducibility crisis that scientific studies are still facing to date. In a recent study, not even half of all research antibodies mentioned in publications could be identified at all. This should spark more efforts in the search for practical solutions for the traceability of antibodies. For this purpose, we used 35 monoclonal antibodies against SARS-CoV-2 to demonstrate how sequence-independent antibody identification can be achieved by simple means applied to the protein. First, we examined the intact and light chain masses of the antibodies relative to the reference material NIST-mAb 8671. Already half of the antibodies could be identified based solely on these two parameters. In addition, we developed two complementary peptide mass fingerprinting methods with MALDI-TOF-MS that can be performed in 60 min and had a combined sequence coverage of over 80%. One method is based on the partial acidic hydrolysis of the protein by 5 mM of sulfuric acid at 99 degrees C. Furthermore, we established a fast way for a tryptic digest without an alkylation step. We were able to show that the distinction of clones is possible simply by a brief visual comparison of the mass spectra. In this work, two clones originating from the same immunization gave the same fingerprints. Later, a hybridoma sequencing confirmed the sequence identity of these sister clones. In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0. This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
The investigation of metabolic fluxes and metabolite distributions within cells by means of tracer molecules is a valuable tool to unravel the complexity of biological systems. Technological advances in mass spectrometry (MS) technology such as atmospheric pressure chemical ionization (APCI) coupled with high resolution (HR), not only allows for highly sensitive analyses but also broadens the usefulness of tracer‐based experiments, as interesting signals can be annotated de novo when not yet present in a compound library. However, several effects in the APCI ion source, i.e., fragmentation and rearrangement, lead to superimposed mass isotopologue distributions (MID) within the mass spectra, which need to be corrected during data evaluation as they will impair enrichment calculation otherwise. Here, we present and evaluate a novel software tool to automatically perform such corrections. We discuss the different effects, explain the implemented
algorithm, and show its application on several experimental datasets. This adjustable tool is available as an R package from CRAN.
Objectives: Using a murine model of multiple sclerosis, we previously showed that repeated administration of gadopentetate dimeglumine led to retention of gadolinium (Gd) within cerebellar structures and that this process was enhanced with inflammation. This study aimed to compare the kinetics and retention profiles of Gd in inflamed and healthy brains after application of the macrocyclic Gd-based contrast agent (GBCA) gadobutrol or the linear GBCA gadopentetate. Moreover, potential Gd-induced neurotoxicity was investigated in living hippocampal slices ex vivo.
Materials and Methods: Mice at peak of experimental autoimmune encephalomyelitis (EAE; n = 29) and healthy control mice (HC; n = 24) were exposed to a cumulative dose of 20 mmol/kg bodyweight of either gadopentetate dimeglumine or gadobutrol (8 injections of 2.5 mmol/kg over 10 days). Magnetic resonance imaging (7 T) was performed at baseline as well as at day 1, 10, and 40 post final injection (pfi) of GBCAs. Mice were sacrificed after magnetic resonance imaging and brain and blood Gd content was assessed by laser ablation-inductively coupled plasma (ICP)-mass spectrometry (MS) and ICP-MS, respectively. In addition, using chronic organotypic hippocampal slice cultures, Gd-induced neurotoxicity was addressed in living brain tissue ex vivo, both under control or inflammatory (tumor necrosis factor α [TNF-α] at 50 ng/μL) conditions.
Results: Neuroinflammation promoted a significant decrease in T1 relaxation times after multiple injections of both GBCAs as shown by quantitative T1 mapping of EAE brains compared with HC. This corresponded to higher Gd retention within the EAE brains at 1, 10, and 40 days pfi as determined by laser ablation-ICP-MS. In inflamed cerebellum, in particular in the deep cerebellar nuclei (CN), elevated Gd retention was observed until day 40 after last gadopentetate application (CN: EAE vs HC, 55.06 ± 0.16 μM vs 30.44 ± 4.43 μM). In contrast, gadobutrol application led to a rather diffuse Gd content in the inflamed brains, which strongly diminished until day 40 (CN: EAE vs HC, 0.38 ± 0.08 μM vs 0.17 ± 0.03 μM). The analysis of cytotoxic effects of both GBCAs using living brain tissue revealed an elevated cell death rate after incubation with gadopentetate but not gadobutrol at 50 mM. The cytotoxic effect due to gadopentetate increased in the presence of the inflammatory mediator TNF-α (with vs without TNF-α, 3.15% ± 1.18% vs 2.17% ± 1.14%; P = 0.0345).
Conclusions: In the EAE model, neuroinflammation promoted increased Gd retention in the brain for both GBCAs. Whereas in the inflamed brains, efficient clearance of macrocyclic gadobutrol during the investigated time period was observed, the Gd retention after application of linear gadopentetate persisted over the entire observational period. Gadopentetate but not gadubutrol appeared to be neurotoxic in an ex vivo paradigm of neuronal inflammation.
Formation Mechanism of a Nano-Ring of Bismuth Cations and Mono-Lacunary Keggin-Type Phosphomolybdate
(2022)
A new hetero-bimetallic polyoxometalate (POM) nano-ring was synthesized in a one-pot procedure. The structure consists of tetrameric units containing four bismuth-substituted monolacunary Keggin anions including distorted [BiO8] cubes. The nano-ring is formed via self-assembly from metal precursors in aqueous acidic medium. The compound (NH4)16[(BiPMo11O39)4] ⋅ 22 H2O; (P4Bi4Mo44) was characterized by single-crystal X-ray diffraction, extended X-ray absorption fine structure spectroscopy (EXAFS), Raman spectroscopy, matrix-assisted laser desorption/ionisation-time of flight mass spectrometry (MALDI-TOF), and thermogravimetry/differential scanning calorimetry mass spectrometry (TG-DSC-MS). The formation of the nano-ring in solution was studied by time-resolved in situ small- and wide-angle X-ray scattering (SAXS/WAXS) and in situ EXAFS measurements at the Mo−K and the Bi−L3 edge indicating a two-step process consisting of condensation of Mo-anions and formation of Bi−Mo-units followed by a rapid self-assembly to yield the final tetrameric ring structure.
Fast and accurate determination of the protein content of a sample is an important and non-trivial task of many biochemical, biomedical, food chemical, pharmaceutical, and environmental research activities. Different methods of total protein determination are used for a wide range of proteins with highly variable properties in complex matrices. These methods usually work reasonably well for proteins under controlled conditions, but the results for non-standard and complex samples are often questionable. Here, we compare new and well-established methods, including traditional amino acid analysis (AAA), aromatic amino acid analysis (AAAA) based on the amino acids phenylalanine and tyrosine, reversed-phase liquid chromatography of intact proteins with UV absorbance measurements at 220 and 280 nm (LC-220, LC-280), and colorimetric assays like Coomassie Blue G-250 dye-binding assay (Bradford) and bicinchoninic acid (BCA) assay. We investigated different samples, including proteins with challenging properties, chemical modifications, mixtures, and complex matrices like air particulate matter and pollen extracts. All methods yielded accurate and precise results for the protein and matrix used for calibration. AAA, AAAA with fluorescence detection, and the LC-220 method yielded robust results even under more challenging conditions (variable analytes and matrices). These methods turned out to be well-suited for reliable determination of the protein content in a wide range of samples, such as air particulate matter and pollen.
The study, dedicated to Beautiful Pietàs conserved in South Tyrol (Northern Italy), aims to establish, for the first time, a connection between Austroalpine raw materials and the high-fired gypsum mortars constituting the Gothic figure groups in question. The origin and chronology of this stylistically and qualitatively differing ensemble have been subject of art historical debate for nearly a century. The discourse is dominated by three main hypotheses: itinerary of an Austrian artist versus itinerary of the work of art created in an artist’s workshop in Austria versus itinerary of the stylistic vocabulary via graphical or three-dimensional models. The comparison of the δ34S values and the 87Sr/86Sr ratios of the gypsum mortars and Austroalpine sulphate deposits (in a compilation of own reference samples and literature data) points to the exploitation of sediments in the Salzkammergut and possibly also in the evaporite district of the Eastern Calcareous Alps, thus evidencing the import of the sculptures and not the activities of local South Tyrolean or itinerant artists. Two geochronological units are distinguishable: The Pietà in the Church St. Martin in Göflan can be assigned to Upper Permian raw material, whereas the metrologically consistent sculptures in the Church of Our Lady of the Benedictine Abbey Marienberg and in the Chapel St. Ann in Mölten correlate with deposits of the Early Triassic (or the Lower-Middle Triassic transition). The medieval gypsum mortars also differ in their mineralogical characteristics, i.e. in their geologically related minor components, as in the first case, characterised by a significant proportion of primary anhydrite, natural carbonate impurities mainly consist of calcite (partly converted to lime-lump-like aggregates), whereas in the second group dolomite (or rather its hydration products after pyrometamorphic decomposition) predominates, accompanied by celestine, quartz and potassium feldspar. The Pietà in the Cathedral Maria Himmelfahrt in Bozen turned out to be made of Breitenbrunn calcareous sandstone (Leitha Mountains, Burgenland, Austria), which is why the sample is not considered in the geochemical analysis.
Quantitative proteomics is a growing research area and one of the most important tools in the life sciences. Well-characterized and quantified protein standards are needed to achieve accurate and reliable results. However, only a limited number of sufficiently characterized protein standards are currently available. To fill this gap, a method for traceable protein quantification using sulfur isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) was developed in this study.
Gel filtration and membrane filtration were tested for the separation of non-protein-bound sulfur in the protein solution.
Membrane filtration demonstrated a better performance due to the lower workload and the very low sulfur blanks of 11 ng, making it well suited for high-purity proteins such as NIST SRM 927, a bovine serum albumin (BSA). The method development was accomplished with NIST SRM 927e and a commercial avidin. The quantified mass fraction of NIST SRM 927e agreed very well with the certified value and showed similar uncertainties (3.6%) as established methods while requiring less sample preparation and no species-specific standards. Finally, the developed procedure was applied to the tau protein, which is a biomarker for a group of neurodegenerative diseases denoted “tauopathies” including, e.g., Alzheimer’s disease and frontotemporal dementia. For the absolute quantification of tau in the brain of transgenic mice overexpressing human tau, a well-defined calibration standard was needed. Therefore, a pure tau solution was quantified, yielding a protein mass fraction of (0.328 ± 0.036) g/kg, which was confirmed by amino acid analysis.
The entire process involving the determination of Cl by molecular emission detection in Laser-Induced Breakdown Spectroscopy (LIBS) is thoroughly studied in this paper. This critical evaluation considers how spectra are normalized, how interferences from other molecular species signals are removed, and how signal integration is applied. Moreover, a data treatment protocol is proposed to achieve reliable and accurate Cl determination from the CaCl molecular spectral signal, not requiring the use of more complex numerical approaches. Calcium chloride dihydrate (CaCl2⋅2H2O) and high purity anhydrite samples (CaSO4) are used to optimize the acquisition conditions and data treatment of CaCl emission signal. Using the developed protocol, calibration curves for Cl, covering the concentration range from 0 μg/g to 60,000 μg/g of Cl, are successfully achieved. Finally, the suitability of the proposed methodology for Cl determination is successfully applied in industrial gypsum waste samples, where the results obtained by LIBS are validated using high-resolution molecular absorption spectroscopy (HR-CS-MAS) and potentiometric titration.
Here, we describe an optimized fast and simple extraction method for the determination of per- and polyfluorinated alkyl substances (PFASs) in soils utilizing high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR–CS–GFMAS). To omit the bias of the solid phase extraction (SPE) step commonly used during the analysis of extractable organically bound fluorine (EOF) we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol without any additional SPE. Four extraction steps were representative to determine a high proportion of the EOF (>80% of eight extractions). Comparison of the optimized method with and without an additional SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. Differences of up to 94% were observed which were not explainable by coextracted inorganic fluoride. Therefore, not only a more accurate but also a more economic as well as ecologic method (bypassing of unnecessary SPE) was developed. The procedural limit of quantification (LOQ) of the developed method was 10.30 μg/kg which was sufficient for quantifying EOF concentrations in all tested samples. For future PFAS monitoring and potential regulative decisions the herein presented optimized extraction method can offer a valuable contribution.
n situ monitoring of mechanochemical reactions between dicyandiamide (DCD) and CuX2 salts (X = Cl−, NO3−), for the preparation of compounds of agrochemical interest, showed the appearance of a number of phases. It is demonstrated that milling conditions, such as the amount of water added in wet grinding and/or the milling frequency, may affect the course of the mechanochemical reactions, and drive the reaction towards the formation of different products. It has been possible to discover by in situ monitored experiments two novel crystalline forms, namely the neutral complexes [Cu(DCD)2(OH2)2(NO3)2] (2) and [Cu(DCD)2(OH2)Cl2]·H2O (4), in addition to the previously known molecular salt [Cu(DCD)2(OH2)2][NO3]2·2H2O (1, DIVWAG) and neutral complex [Cu(DCD)2(OH2)Cl2] (3, AQCYCU), for which no synthesis conditions were available. Compounds 2 and 4 were fully characterized via a combination of solid-state techniques, including X-ray diffraction, Raman spectroscopy and TGA.
Imaging Keratan Sulfate in Ocular Tissue Sections by Immunofluorescence Microscopy and LA-ICP-MS
(2022)
Carbohydrate-specific antibodies can serve as valuable tools to monitor alterations in the extracellular matrix resulting from pathologies. Here, the keratan sulfate-specific monoclonal antibody MZ15 was characterized in more detail by immunofluorescence microscopy as well as laser ablation ICP-MS using tissue cryosections and paraffin-embedded samples. Pretreatment with keratanase II prevented staining of samples and therefore demonstrated efficient enzymatic keratan sulfate degradation. Random fluorescent labeling and site-directed introduction of a metal cage into MZ15 were successful and allowed for a highly sensitive detection of the keratan sulfate landscape in the corneal stroma from rats and human tissue.
Tire wear (TW) constitutes a significant source of microplastic in terrestrial ecosystems. It is known that particles emitted by roads can have an effect up to 100 m into adjacent areas. Here, we apply for the first-time thermal extraction desorption gas chromatography-mass spectrometry (TED-GC/MS) to determine TW in soil samples by detection of thermal decomposition products of styrene-butadiene rubber (SBR), without additional enrichment. Additionally, zinc contents were determined as an elemental marker for TW. Mixed soil samples were taken along three transects along a German motorway in 0.3, 2.0, and 5.0 m distance from the road. Sampling depths were 0–2, 2–5, 5–10, and 10–20 cm. Four fine fractions, 1 000–500, 500–100, 100–50, and <50 μm, were analyzed.
TW contents based on SBR ranged from 155 to 15 898 mg kg−1. TW contents based on zinc were between 413 and 44 812 mg kg−1. Comparison of individual values of SBR and zinc reveals SBR as a more specific marker. Results confirm that most TW ends up in the topsoil within a 2 m distance.
The sampling strategy resulted in representative data for a larger area. Standard deviations of quadruple TED-GC/MS determination of SBR were <10% for all grain size fractions. TED-GC/MS is a suitable analytical tool for determining TW in soil samples without the use of toxic chemicals, enrichment, or special sample preparation.
With the increasing production of renewable energy and concomitant depletion of fossil resources, the demand for efficient water splitting electrocatalysts continues to grow. Iridium (Ir) and iridium oxides (IrOₓ) are currently the most promising candidates for an efficient oxygen evolution reaction (OER) in acidic medium, which remains the bottleneck in water electrolysis. Yet, the extremely high costs for Ir hamper a widespread production of hydrogen (H₂) on an industrial scale. Herein, the authors report a concept for the synthesis of electrode coatings with template-controlled mesoporosity surface-modified with highly active Ir species. The improved utilization of noble metal species relies on the synthesis of soft-templated metal oxide supports and a subsequent shape-conformal deposition of Ir species via atomic layer deposition (ALD) at two different reaction temperatures. The study reveals that a minimum Ir content in the mesoporous titania-based support is mandatory to provide a sufficient electrical bulk conductivity. After ALD, a significantly enhanced OER activity results in dependency of the ALD cycle number and temperature. The most active developed electrocatalyst film achieves an outstanding mass-specific activity of 2622 mA mg(Ir)⁻¹ at 1.60 V(RHE) in a rotating-disc electrode (RDE) setup at 25 °C using 0.5 m H₂SO₄ as a supporting electrolyte.
The drug salinomycin (SAL) is a polyether antibiotic and used in veterinary Medicine as coccidiostat and growth promoter. Recently, SAL was suggested as a potential anticancer drug.
However, transformation products (TPs) resulting from metabolic and environmental degradation of SAL are incompletely known and structural information is missing. In this study, we therefore systematically investigated the formation and identification of SAL derived TPs using electrochemistry (EC) in an electrochemical reactor and rat and human liver microsome incubation (RLM and HLM) as TP generating methods. Liquid chromatography (LC) coupled to high-resolution mass spectrometry (HRMS) was applied to determine accurate masses in a suspected target analysis to identify TPs and to deduce occurring modification reactions of derived TPs. A total of 14 new, structurally different TPs were found (two EC-TPs, five RLM-TPs, and 11 HLM-TPs). The main modification reactions are decarbonylation for EC-TPs and oxidation (hydroxylation) for RLM/HLM-TPs. Of particular interest are potassium-based TPs identified after liver microsome incubation because these might have been overlooked or declared as oxidated sodium adducts in previous, non-HRMS-based studies due to the small mass difference between K and O + Na of 21 mDa. The MS fragmentation pattern of TPs was used to predict the position of identified modifications in the SAL molecule. The obtained knowledge regarding transformation reactions and novel TPs of SAL will contribute to elucidate SAL-metabolites with regards to structural prediction.