Chemische Charakterisierung und Spurenanalytik
Filtern
Erscheinungsjahr
- 2018 (62) (entfernen)
Dokumenttyp
- Vortrag (62)
Sprache
- Englisch (62) (entfernen)
Referierte Publikation
- nein (62)
Schlagworte
- Fluorescence (5)
- ICP-MS (5)
- Laser ablation (5)
- Nanoparticle (5)
- Nanoparticles (4)
- Traceability (4)
- BAMline (3)
- Benchtop NMR spectroscopy (3)
- HR-CS-MAS (3)
- Imaging (3)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (46)
- 1.1 Anorganische Spurenanalytik (21)
- 6 Materialchemie (14)
- 6.3 Strukturanalytik (10)
- 1.4 Prozessanalytik (8)
- 1.6 Anorganische Referenzmaterialien (8)
- 1.9 Chemische und optische Sensorik (6)
- 1.2 Biophotonik (4)
- 1.0 Abteilungsleitung und andere (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 1.8 Umweltanalytik (3)
- 6.6 Physik und chemische Analytik der Polymere (3)
- 4 Material und Umwelt (2)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
- 8 Zerstörungsfreie Prüfung (2)
- 1.3 Instrumentelle Analytik (1)
- 4.0 Abteilungsleitung und andere (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (1)
- 8.0 Abteilungsleitung und andere (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 9 Komponentensicherheit (1)
- 9.0 Abteilungsleitung und andere (1)
- 9.4 Integrität von Schweißverbindungen (1)
- P Präsident (1)
- P.0 Präsident und andere (1)
- PST Präsidiale Stabsstelle (1)
Eingeladener Vortrag
- nein (62) (entfernen)
Hydrogen determination in weld seams is standardized in ISO 3690. In accordance to this standard, a defined time for hydrogen collection has to be anticipated for different extraction temperatures. In other words, the temperature is the most important value that has to be monitored in addition to the aimed hydrogen determination.
The specimen geometry has influence on the real sample temperature during CGHE vs. the adjusted furnace temperature. This presentation gives a short summary on possible influences on the "correct" hydrogen determination temperature during carrier gas hot extraction (CGHE) using infrared radiation driven furnace. The main findings are: (1) specimen surface is important in terms of polished or oxidized condition, (2) specimen geometry is important for fast heating, (3) PID-values of control software are a considerable influence to accelerate the heating process depite thick specimens and (4) independent sample temperature determination before CGHE is strongly recommended.
The overall interest in nanotoxicity, triggered by the increasing use of nanomaterials in the material and life sciences, and the synthesis of an ever increasing number of new functional nanoparticles calls for standardized test procedures1,2 and for efficient approaches to screen the potential genotoxicity of these materials. Aiming at the development of fast and easy to use, automated microscopic methods for the determination of the genotoxicity of different types of nanoparticles, we assess the potential of the fluorometric γH2AX assay for this purpose. This assay, which can be run on an automated microscopic detection system, relies on the detection of DNA double strand breaks as a sign for genotoxicity3. Here, we provide first results obtained with broadly used nanomaterials like CdSe/CdS and InP/ZnS quantum dots as well as iron oxide, gold, and polymer particles of different surface chemistry with previously tested colloidal stability and different cell lines like Hep-2 and 8E11 cells, which reveal a dependence of the genotoxicity on the chemical composition as well as the surface chemistry of these nanomaterials. These studies will be also used to establish nanomaterials as positive and negative genotoxicity controls or standards for assay performance validation for users of this fluorometric genotoxicity assay. In the future, after proper validation, this microscopic platform technology will be expanded to other typical toxicity assays.