Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (72) (entfernen)
Schlagworte
- BAMline (10)
- Synchrotron (10)
- MALDI-TOF MS (7)
- Mechanochemistry (7)
- Microplastics (7)
- TED-GC/MS (7)
- Microplastic (6)
- Nanoparticle (5)
- XRF (5)
- Polylactide (4)
- XRD (4)
- In situ (3)
- CXC (2)
- Crystalinity (2)
- MALDI TOF MS (2)
- Mikroplastik (2)
- Pollen (2)
- SAXS (2)
- Tire wear (2)
- XANES (2)
- A4F (1)
- AG nanoparticle (1)
- AU nanoparticle (1)
- Absorption spectrometry (1)
- Acidic oxygen evolution reaction (1)
- Acute myocardial infarction (1)
- Additive Manufacturing (1)
- Affinity Chromatography (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Aktivkohle (1)
- Amperometry (1)
- Amyloid (1)
- Analysis (1)
- Antibody Purification (1)
- Antikensammlung Berlin (1)
- Archaeometry (1)
- Aspergillus (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Atomic layer deposition (1)
- Automated Purification (1)
- Automation (1)
- Barium (1)
- Battery (1)
- Bbeverages (1)
- Bioimaging (1)
- Biological & biomedical applications (1)
- Biomarker (1)
- Biosensor (1)
- Biosynthesis (1)
- Bismuth (1)
- Bisphenol A (1)
- Bone matrix (1)
- Borosilicate Glass (1)
- CCQM key comparison (1)
- Calcium monofluoride (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Carboxyl group (1)
- Cardiac troponin (1)
- Catalysts (1)
- Cathode material (1)
- Chemical transformation (1)
- Chemiluminescence (1)
- Citizen Science (1)
- Classification (1)
- Cobalt deposition (1)
- Cocoa (1)
- Coded Aperture (1)
- Column holder (1)
- Compost (1)
- Concentration step (1)
- Conjugate (1)
- Construction (1)
- Coordination polymers (1)
- Corrosion (1)
- Coupling reactions (1)
- Crystallization (1)
- Cyclic voltammetry (1)
- Cyclization (1)
- Cycloparaphenylenes (1)
- D2XRF (1)
- Debye-Waller parameter (1)
- Density separation (1)
- Depth profile (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Dispersive-XAS (1)
- Down Stream Processing (1)
- EXAFS (1)
- Electrocatalysis (1)
- Electrochemistry (1)
- Elektronenmikroskopie (1)
- Emergency (1)
- Endocrine disruptor (1)
- Energy storage (1)
- Environmental impacts (1)
- Epoxy (1)
- Extended X-ray absorption fine structure (1)
- FPLC (1)
- FTIR (1)
- Fenton (1)
- Filter crucible (1)
- Flow injection immunoassay (1)
- Fluorine (1)
- Folic acid (1)
- Fundamentals (1)
- Fusarium (1)
- General Chemistry (1)
- General Materials Science (1)
- Gilding (1)
- Glass Support (1)
- Gold (1)
- Graphite furnace (1)
- Greek curse tablets (1)
- HERFD-XAS (1)
- HPLC (1)
- HR-CS-MAS (1)
- Hazardous substances (1)
- Heart attack (1)
- Heavy metals (1)
- Hierarchical cluster analysis (1)
- High-Speed Separations (1)
- High-resolution synchrotron XRF (1)
- Histology (1)
- Host–guest systems (1)
- Human Plasma (1)
- IgG determination (1)
- Immunoassay (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Implant material (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In situ studies (1)
- Inlet ionization (1)
- Ion mobility (1)
- Ionization (1)
- Iridium oxide (1)
- Lacunary Keggin ion (1)
- Lanthanide (1)
- Lead ions (1)
- Lead isotopes (1)
- Li-ion battery (1)
- Luminol (1)
- MALDI Imaging MS (1)
- MAS NMR spectroscopy (1)
- MCC (1)
- MOF (1)
- Machine learning (1)
- Macrocycles (1)
- Macrophagen (1)
- Magnetic nanocatalyst (1)
- Maia detector (1)
- Mass contents (1)
- Mass spectrometry (1)
- Matrices (1)
- Mechanism (1)
- Mechanochemical synthesis (1)
- Metal nanoparticles (1)
- Microfluidic system (1)
- Microplastic analysis (1)
- Microplastic pathways (1)
- Microplastics analytic (1)
- Mikroplastik Massegehalt (1)
- Modelling (1)
- Molecular recognition (1)
- Molecule (1)
- Monitoring (1)
- Monoclonal Antibodies (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Monolithic column (1)
- Multimodal (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- Mycotoxin (1)
- NIR spectroscopy (1)
- Nano (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanoparticles with same nominal diameter (1)
- Near edge X-ray absorption fine structure spectroscopy (1)
- Neural network (1)
- Nondestructive testing techniques (1)
- OECD (1)
- Ochratoxin A (1)
- Online biosensor (1)
- Open Science (1)
- P-aminothiophenol (1)
- PXRD (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle size distribution (1)
- Pb isotopes (1)
- Peroxidase (1)
- Phosphonate esters (1)
- Photodegradation (1)
- Photooxidation (1)
- Plastic bottles (1)
- Pollen grains (1)
- Polyclonal Antibodies (1)
- Polymer blends (1)
- Polymers (1)
- Polymorphs (1)
- Polyoxometalates (1)
- Polyurethanes (1)
- Principal component analysis (1)
- Principal component analysis (PCA) (1)
- Protein A (1)
- Protein Purification (1)
- Purity assessment (1)
- Quick-XAS (1)
- RXES (1)
- Raman (1)
- Reference material (1)
- Refractory alloys (1)
- Regeneration (1)
- Renewable Energy (1)
- Rhizopus (1)
- River (1)
- Robustness (1)
- Sample preparation (1)
- Sampling (1)
- Sampling techniques (1)
- Sedimentation box (SB) (1)
- Self-assembly (1)
- Sensing (1)
- Sers (1)
- Silver nanoparticles (1)
- Sintered Material (1)
- Slags (1)
- Soft-templated mesoporous films (1)
- Soil (1)
- Solvent-free (1)
- Sonochemical synthesis (1)
- Spectroscopy (1)
- Spinel (1)
- Supramolecular chemistry (1)
- Surface coating (1)
- Suspended particulate matter (SPM) (1)
- Sustainability and the Environment (1)
- TED-GC-MS (1)
- TGA-FTIR (1)
- TGA-MS (1)
- TXRF-XAS (1)
- Tattoo inks (1)
- Tesserae (1)
- The MOUSE (1)
- Therapeutic Antibodies (1)
- Thermal analysis (1)
- Thermal degradation (1)
- Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS), monitoring (1)
- Thermal extraction-desorption gas chromatography mass spectrometry (1)
- Thermo-desorption (1)
- Thermogravimetrie (1)
- Tire Wear (1)
- Tire particles (1)
- Toxic metals (1)
- Transesterification (1)
- Trinkwasser (1)
- Two-dimensional off-line coupling (1)
- Urban (1)
- Vacuum ionization (1)
- Vanadium redox flow battery (1)
- Wasseraufbereitung (1)
- Wastewater (1)
- Water (1)
- X-Ray Fluorescence (1)
- X-ray absorption spectroscopy (1)
- X-ray fluorescence spectroscopy (1)
- XAS (1)
- Xerogel (1)
- Zearalenone (1)
- Zinc analysis (1)
- Zirconium (1)
- Ägyptisches Museum Berlin (1)
Organisationseinheit der BAM
- 6 Materialchemie (72) (entfernen)
Paper des Monats
- ja (1)
n situ monitoring of mechanochemical reactions between dicyandiamide (DCD) and CuX2 salts (X = Cl−, NO3−), for the preparation of compounds of agrochemical interest, showed the appearance of a number of phases. It is demonstrated that milling conditions, such as the amount of water added in wet grinding and/or the milling frequency, may affect the course of the mechanochemical reactions, and drive the reaction towards the formation of different products. It has been possible to discover by in situ monitored experiments two novel crystalline forms, namely the neutral complexes [Cu(DCD)2(OH2)2(NO3)2] (2) and [Cu(DCD)2(OH2)Cl2]·H2O (4), in addition to the previously known molecular salt [Cu(DCD)2(OH2)2][NO3]2·2H2O (1, DIVWAG) and neutral complex [Cu(DCD)2(OH2)Cl2] (3, AQCYCU), for which no synthesis conditions were available. Compounds 2 and 4 were fully characterized via a combination of solid-state techniques, including X-ray diffraction, Raman spectroscopy and TGA.
Tire wear (TW) constitutes a significant source of microplastic in terrestrial ecosystems. It is known that particles emitted by roads can have an effect up to 100 m into adjacent areas. Here, we apply for the first-time thermal extraction desorption gas chromatography-mass spectrometry (TED-GC/MS) to determine TW in soil samples by detection of thermal decomposition products of styrene-butadiene rubber (SBR), without additional enrichment. Additionally, zinc contents were determined as an elemental marker for TW. Mixed soil samples were taken along three transects along a German motorway in 0.3, 2.0, and 5.0 m distance from the road. Sampling depths were 0–2, 2–5, 5–10, and 10–20 cm. Four fine fractions, 1 000–500, 500–100, 100–50, and <50 μm, were analyzed.
TW contents based on SBR ranged from 155 to 15 898 mg kg−1. TW contents based on zinc were between 413 and 44 812 mg kg−1. Comparison of individual values of SBR and zinc reveals SBR as a more specific marker. Results confirm that most TW ends up in the topsoil within a 2 m distance.
The sampling strategy resulted in representative data for a larger area. Standard deviations of quadruple TED-GC/MS determination of SBR were <10% for all grain size fractions. TED-GC/MS is a suitable analytical tool for determining TW in soil samples without the use of toxic chemicals, enrichment, or special sample preparation.
Die große Herausforderung in der Detektion von Mikroplastik (MP)‑Partikeln (1-1000 µm) besteht darin, sie neben Millionen von natürlichen Partikeln in Umweltproben nachzuweisen. Zum Aufspüren von Senken, Eintragspfaden und für Monitoring-Kampagnen ist ein schnelles, automatisiertes Verfahren unerlässlich. Ein solches Verfahren wurde an der Bundesanstalt für Materialforschung und -prüfung (BAM) mit der ThermoExtraktion/Desorption-Gaschromatographie-Massenspektrometrie (TED-GC/MS) in den letzten Jahren entwickelt.
With the increasing production of renewable energy and concomitant depletion of fossil resources, the demand for efficient water splitting electrocatalysts continues to grow. Iridium (Ir) and iridium oxides (IrOₓ) are currently the most promising candidates for an efficient oxygen evolution reaction (OER) in acidic medium, which remains the bottleneck in water electrolysis. Yet, the extremely high costs for Ir hamper a widespread production of hydrogen (H₂) on an industrial scale. Herein, the authors report a concept for the synthesis of electrode coatings with template-controlled mesoporosity surface-modified with highly active Ir species. The improved utilization of noble metal species relies on the synthesis of soft-templated metal oxide supports and a subsequent shape-conformal deposition of Ir species via atomic layer deposition (ALD) at two different reaction temperatures. The study reveals that a minimum Ir content in the mesoporous titania-based support is mandatory to provide a sufficient electrical bulk conductivity. After ALD, a significantly enhanced OER activity results in dependency of the ALD cycle number and temperature. The most active developed electrocatalyst film achieves an outstanding mass-specific activity of 2622 mA mg(Ir)⁻¹ at 1.60 V(RHE) in a rotating-disc electrode (RDE) setup at 25 °C using 0.5 m H₂SO₄ as a supporting electrolyte.
The vanadium redox flow battery (VRFB) is currently a potential candidate for stationary energy storage. A major challenge is the unintended vanadium transport through the separator, which results in a fade of capacity. To overcome this issue, it is necessary to understand the transport processes in the membrane on a more fundamental level. In this work, the vanadium species distribution in Nafion™ 117 after cyclization was investigated. Two membranes, one from a charged VRFB and another from a discharged VRFB, were analyzed using ultraviolet–visible spectroscopy (UV/VIS) and X-ray absorption near edge structure spectroscopy (XANES). Little difference between the two membranes was recognizable according to the UV/VIS results. In comparison, the XANES results showed that the membrane from the charged VRFB contains more V3+ than VO2+, whereas for the discharged case, more VO2+ is present in the membrane.
X-ray absorption spectroscopy (XAS), in its various modalities, has gained exponential attention and applicability in the field of biological and biomedical systems. Particularly in this field, challenges like low concentration of analyte or proneness to radiation damage have certainly settle the basis for further analytical developments, when using X-ray based methods. Low concentration calls for higher sensitivity—by increasing the detection limits (DL); while susceptibility for radiation damage requires shorter measurement times and/or cryogenic sample environment possibilities. This manuscript reviews the latest analytical possibilities that make XAS more and more adequate to investigate biological or biomedical systems in the last 5 years.
Electrochemical methods offer great promise in meeting the demand for user-friendly on-site devices for Monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme-linked immunosorbent assays, with photometric detection of 3,3’,5,5’-tetramethylbenzidine (TMB),form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detectionstep, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphonebased, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis forsensing of further analytes.
A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 min. Due to the glass material’s excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nano-filtration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run.
SnOct2 (Sn(II) 2-ethylhexanoate) catalyzed ROPs of L-lactide were performed in bulk with eight different alcohols as initiators. The time was varied between 1 h and 24 h for all initiators. For two initiators the temperature was also lowered to 115 ◦C. Even-numbered chains were predominantly formed in all polymerizations at short times, but the rate of transesterification (e.g. even/odd equilibration) and the molecular weight distribution were found to depend significantly on the nature of the initiator. Observed transesterification reactions also continued in solid poly (L-lactide), and with the most active initiator, almost total equilibration was achieved even at 130 ◦C. This means that all chains including those of the crystallites were involved in transesterification reactions proceeding across the flat surfaces of the crystallites. The more or less equilibrated crystalline polylactides were characterized by DSC and SAXS measurements with regard to their melting temperature (Tm), crystallinity and crystal thickness.
The scientific and practical challenge of detecting microplastics (MPs) in the environment in a targeted and rapid manner is solved by innovative coupling of thermogravimetric analysis with mass spectrometric methods.
Fast identification and quantitative determination of most thermoplastic polymers and elastomers is possible by using thermal extraction Desorption gas chromatography–mass spectrometry (TED-GC–MS).
A set of strained aromatic macrocycles based on [n]cyclo2,7-(4,5,9,10-tetrahydro)pyrenylenes is presented with size dependent photophysical properties. The K-region of pyrene was functionalized with ethylene glycol groups to decorate the outer rim and thereby confine the space inside the macrocycle. This confined space is especially pronounced for n = 5, which leads to an internal binding of up to 8.0×104 M–1 between the ether-decorated [5]cyclo-2,7-pyrenylene and shape complementary crown ether–cation complexes.
Both, the ether-decorated [n]cyclo-pyrenylenes as well as one of their host–guest complexes have been structurally characterized by single crystal X-ray analysis. In combination with computational methods the structural and thermodynamic reasons for the exceptionally strong binding have been elucidated. The presented rim confinement strategy makes cycloparaphenylenes an attractive supramolecular host family with a favorable, size-independent read-out signature and binding capabilities extending beyond fullerene guests.
The occurrence of microplastic (MP) in food products, such as beverages in plastic bottles, is of high public concern. Existing analytical methods focus on the determination of particle numbers, requiring elaborate sampling tools, laboratory infrastructure and generally time-consuming imaging detection methods. A comprehensive routine analysis of MP in food products is still not possible. In the present work, we present the development of a smart filter crucible as sampling and detection tool. After filtration and drying of the filtered-off solids, a direct determination of the MP mass content from the crucible sample can be done by thermal extraction desorption gas chromatography mass spectroscopy (TED-GC/MS). The new filter crucible allows a filtration of MP down to particle sizes of 5 µm. We determined MP contents below 0.01 µg/L up to 2 µg/L, depending on beverages bottle type. This may be directly related to the bottle type, especially the quality of the plastic material of the screw cap. Dependent on the plastic material, particle formation increases due to opening and closing operations during the use phase. However, we have also found that some individual determinations of samples were subjected to high errors due to random events. A conclusive quantitative evaluation of the products is therefore not possible at present.
In this work, we describe the use of artificial neural networks for the quantification of X-ray fluorescence measurements. The training data were generated using Monte Carlo simulation, which avoided the use of adapted reference materials. The extension of the available data set by means of an ANN to generate additional data was demonstrated. Particular emphasis was put on the comparability of simulated and experimental data and how the influence of deviations can be reduced. The search for the optimal hyperparameter, manual and automatic, is also described. For the presented case, we were able to train a network with a mean absolute error of 0.1 weight percent for the synthetic data and 0.7 weight percent for a set of experimental data obtained with certified reference materials.
Microplastic particles are currently detected in almost all environmental compartments. The results of detection vary widely, as a multitude of very different methods are used with very different requirements for analytical validity.
In this work four thermoanalytical methods are compared and their advantages and limitations are discussed. One of them is thermal extraction-desorption gas chromatography mass spectrometry (TED-GC/MS), an analysis method for microplastic detection that has become established in recent years. In addition, thermogravimetric analysis coupled with Fourier-transform infrared spectroscopy (TGA-FTIR) and mass spectrometry (TGA-MS) were applied, two methods that are less common in this field but are still used in other research areas. Finally, microscale combustion calorimeter (MCC) was applied, a method not yet used for microplastic detection.
The presented results are taken from a recently published interlaboratory comparison test by Becker et al. (2020). Here a reference material consisting of suspended matter and specified added polymer masses was examined, and only the results of the recoveries were presented. In the present paper, however, the results for the individual polymers are discussed in detail and individual perspectives for all instruments are shown.
It was found that TED-GC/MS is the most suitable method for samples with unknown matrix and unknown, variable kinds and contents of microplastic. TGA-FTIR is a robust method for samples with known matrix and with defined kinds of microplastic. TGA-MS may offer a solution for the detection of PVC particles in the future. MCC can be used as a very fast and simple screening method for the identification of a potential microplastic load of standard polymers in unknown samples.
Tire and road wear particles (TRWPs) are heteroagglomerates of tire rubber and other particles deposited on the road surface and one of the main contributors to non-exhaust emissions of automobile traffic. In this study, samples from road environments were analyzed for their TRWP contents and concentra- tions of eight organic tire constituents. TRWP concentrations were determined by quantifying Zn in the density fraction < 1.9 g/cm ³and by thermal extraction desorption-gas chromatography-mass spectrometry (TED-GC/MS) and the concentrations ranged from 3.7 to 480 mg TRWP/g. Strong and statistically signif- icant correlations with TRWPs were found for 2-hydroxybenzothiazole and 2-aminobenzothiazole, indi- cating that these substances may be suitable markers of TRWPs. The mass distribution of TRWPs in road dust suggests that the main mass fraction formed on roads consists of coarse particles ( > 100 μm). Data for a sedimentation basin indicate that the fine fraction ( < 50 μm) is preferentially transported by road runoffinto receiving waters. The size distribution and density data of TRWP gathered by three different quantitation approaches also suggest that aging of TRWPs leads to changes in their particle density. An improved understanding of the dynamics of TRWP properties is essential to assess the distribution and dissipation of this contaminant of emerging concern in the environment.
Two sets of polystyrene nanoparticles (PSNPs) with comparable core sizes but different carboxyl group densities were made and separated using asymmetric flow field flow fractionation (AF4), capillary electrophoresis (CE), and the off-line hyphenation of both methods. Our results revealed the significant potential of two-dimensional off-line AF4-CE hyphenation to improve the separation and demonstrated for the first time, the applicability of CE to determine the functional group density of nanoparticles (NPs). Compared to the result acquired with conductometric titration, the result obtained with synthesized 100 nm sized PSNPs revealed only a slight deviation of 1.7%. Commercial 100 nm sized PSNPs yielded a deviation of 4.6 %. For 60 nm sized PSNPs, a larger deviation of 10.6 % between both methods was observed, which is attributed to the lower separation resolution.
To better study the impact of nanoparticles on both in vitro and in vivo models, tissue distribution and cellular doses need to be described more closely. Here silver nanoparticles were visualized in alveolar macrophages by means of synchrotron radiation micro X-ray fluorescence spectroscopy (SR-μXRF) with high spatial resolution of 3 × 3 μm2. For the spatial allocation of silver signals to cells and tissue structures, additional elemental labeling was carried out by staining with eosin, which binds to protein and can be detected as bromine signal with SR-μXRF. The method was compatible with immunostaining of macrophage antigens. We found that the silver distribution obtained with SR-μXRF was largely congruent with distribution maps from a subsequent laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) of the same tissue sites. The study shows a predominant, though not exclusive uptake of silver into alveolar macrophages in the rat lung, which can be modeled by a similar uptake in cultured alveolar macrophages. Advantages and limitations of the different strategies for measuring nanoparticle uptake at the single cell level are discussed.
Cyclic poly(L-lactide)s were prepared by ring-opening polymerization combined with simultaneous polycondensation (ROPPOC) in bulk at 160 ° with dibutyltin bis(4-cyanophenoxide) as catalyst. It is demonstrated by MALDI TOF mass spectrometry and 1H NMR end group analyses that cycles are formed by endto-end cyclization in addition to “back-biting” transesterification. Formation of high molar mass cyclic poly L-lactide)s by means of several more reactive ROPPOC catalysts presented previously and in new experiments is discussed. These experimental results, together with theoretical arguments, prove that part of the Jacobson–Stockmayer theory is wrong. The critical monomer concentration, above which end-toend cyclization is seemingly impossible, does not exist and reversible like irreversible polycondensations can theoretically proceed up to 100% conversion, so that finally all reaction products will necessarily adopt a cyclic architecture.
The analysis of pollen chemical composition is important to many fields, including agriculture, plant physiology, ecology, allergology, and climate studies. Here, the potential of a combination of different spectroscopic and spectrometric methods regarding the characterization of small biochemical differences between pollen samples was evaluated using multivariate statistical approaches. Pollen samples, collected from three populations of the grass Poa alpina, were analyzed using Fourier-transform infrared (FTIR) spectroscopy, Raman spectroscopy, surface enhanced Raman scattering (SERS), and matrix assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS). The variation in the sample set can be described in a hierarchical framework comprising three populations of the same grass species and four different growth conditions of the parent plants for each of the populations. Therefore, the data set can work here as a model system to evaluate the classification and characterization ability of the different spectroscopic and spectrometric methods. ANOVA Simultaneous Component Analysis (ASCA) was applied to achieve a separation of different sources of variance in the complex sample set. Since the chosen methods and sample preparations probe different parts and/or molecular constituents of the pollen grains, complementary information about the chemical composition of the pollen can be obtained. By using consensus principal component analysis (CPCA), data from the different methods are linked together. This enables an investigation of the underlying global information, since complementary chemical data are combined. The molecular information from four spectroscopies was combined with phenotypical information gathered from the parent plants, thereby helping to potentially link pollen chemistry to other biotic and abiotic parameters.