Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Vortrag (90)
- Zeitschriftenartikel (72)
- Posterpräsentation (27)
- Forschungsdatensatz (3)
- Forschungsbericht (2)
- Buchkapitel (1)
- Beitrag zu einem Tagungsband (1)
- Preprint (1)
Sprache
- Englisch (156)
- Deutsch (40)
- Mehrsprachig (1)
Schlagworte
- Synchrotron (33)
- BAMline (30)
- Mikroplastik (29)
- TED-GC/MS (25)
- Microplastic (18)
- Microplastics (18)
- XRF (18)
- Mechanochemistry (10)
- TED-GC-MS (9)
- XANES (9)
- MALDI-TOF MS (8)
- Gold (7)
- Machine learning (7)
- Nanoparticle (6)
- Reference material (6)
- Analytik (5)
- Polymer 3R (5)
- XRD (5)
- Analysis (4)
- Automation (4)
- Bayesian Statistics (4)
- In situ (4)
- Pollen (4)
- Polylactide (4)
- Reference materials (4)
- Single cell analysis (4)
- TXRF (4)
- Water (4)
- Archaea (3)
- Coded Aperture (3)
- DNA (3)
- Dosimetry (3)
- Gaussian process (3)
- Machine Learning (3)
- Microbiologically influenced corrosion (3)
- Mikroplastik-Analytik (3)
- Nanoparticles separation capillary electrophoresis asymmetrcial flow field flow fractionation (3)
- Neural network (3)
- Probennahme (3)
- Referenzmaterialien (3)
- SAXS (3)
- Sampling (3)
- Sampling techniques (3)
- Standardisation (3)
- Tire wear (3)
- Trinkwasser (3)
- Affinity Chromatography (2)
- Aktivkohle (2)
- Amperometry (2)
- Analytic (2)
- Artificial Inelligence (2)
- Artificial intelligence (2)
- Asymmetrical flow field flow fractionation (AF4) (2)
- Batteries (2)
- Bayesian Optimization (2)
- Bioimaging (2)
- CXC (2)
- Capillary electrophoresis (2)
- Capillary electrophoresis (CE) (2)
- Certification (2)
- Crystalinity (2)
- D2XRF (2)
- EXAFS (2)
- FPLC (2)
- HPLC (2)
- Harmonisation (2)
- Homogeneity (2)
- ILC (2)
- Immunoassay (2)
- Internal Standard (2)
- Ionization (2)
- Lanthanide (2)
- MALDI TOF MS (2)
- Nanomaterial (2)
- Polymere (2)
- Polymers (2)
- Probenahme (2)
- Quality testing (2)
- Referenzmaterial (2)
- Risk assessment (2)
- SC-ICP-ToF-MS (2)
- Sc-ICP-ToF-MS (2)
- Soil (2)
- Spectroscopy (2)
- Stability (2)
- Standarisierung (2)
- Synthesis (2)
- Thermogravimetrie (2)
- Umwelt (2)
- Wasseraufbereitung (2)
- X-ray fluorescence (2)
- XAFS (2)
- A4F (1)
- AG nanoparticle (1)
- AU nanoparticle (1)
- Absorption spectrometry (1)
- Acidic oxygen evolution reaction (1)
- Acoustic levitation (1)
- Acute myocardial infarction (1)
- Additive (1)
- Additive Manufacturing (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Amyloid (1)
- Analyse (1)
- Analytical Sciences (1)
- Analytical standards (1)
- Antibodies (1)
- Antibody Purification (1)
- Antikensammlung Berlin (1)
- Application properties (1)
- Archaeometry (1)
- Archäometrie (1)
- Artificial Intelligence (1)
- Aspergillus (1)
- Atomic layer deposition (1)
- Aufbereitung (1)
- Automated Purification (1)
- Barium (1)
- Battery (1)
- Bayes (1)
- Bbeverages (1)
- Beamline (1)
- Bernstorf (1)
- Biological & biomedical applications (1)
- Biomarker (1)
- Biosensor (1)
- Biosynthesis (1)
- Bismuth (1)
- Bisphenol A (1)
- Bone matrix (1)
- Borosilicate Glass (1)
- Böden (1)
- CCQM key comparison (1)
- Calcium monofluoride (1)
- Carboxyl group (1)
- Cardiac troponin (1)
- Cascade filtration (1)
- Catalysts (1)
- Cathode material (1)
- Causes leading to scientific misconduct (1)
- Channel access (1)
- Chemical composition (1)
- Chemical transformation (1)
- Chemiluminescence (1)
- Citizen Science (1)
- Classification (1)
- Cobalt deposition (1)
- Cocoa (1)
- Cocrystal (1)
- Color X-ray Camera (1)
- Column holder (1)
- Comparative test (1)
- Compost (1)
- Concentration step (1)
- Conjugate (1)
- Construction (1)
- Coordination polymers (1)
- Core-shell nanoparticles (1)
- Core/shell nanoparticle (1)
- Corrosion (1)
- Coupling reactions (1)
- Crystallization (1)
- Cyclic voltammetry (1)
- Cyclization (1)
- Cycloparaphenylenes (1)
- Cylic Voltammetry (1)
- DNA strand break (1)
- Data conversion (1)
- Data manipulation (1)
- Debye-Waller parameter (1)
- Deep work (1)
- Degradation (1)
- Density separation (1)
- Depth profile (1)
- Desorption (1)
- Detektion (1)
- Detektion von Mikroplastik (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Digital laboratory (1)
- Digitalization (1)
- Dispersive-XAS (1)
- Dose (1)
- Down Stream Processing (1)
- EPICS (1)
- Ectoine (1)
- Ectoine radiation protection (1)
- Egypt (1)
- Electrocatalysis (1)
- Electrochemistry (1)
- Electrohpresis (1)
- Elektronenmikroskopie (1)
- Emergency (1)
- Endocrine disruptor (1)
- Energy input (1)
- Energy storage (1)
- Environmental analysis (1)
- Environmental impacts (1)
- Epoxy (1)
- Extended X-ray absorption fine structure (1)
- FTIR (1)
- Farbenlehre (1)
- Fenton (1)
- Filter crucible (1)
- Filtration (1)
- Flow injection immunoassay (1)
- Fluorescence (1)
- Fluorine (1)
- Folic acid (1)
- Food safety (1)
- Fraktionierte Filtration (1)
- Framework (1)
- Fundamentals (1)
- Fusarium (1)
- GUI (1)
- Gaussian Process (1)
- General Chemistry (1)
- General Materials Science (1)
- Gilding (1)
- Glass (1)
- Glass Support (1)
- Goethe (1)
- Graphite furnace (1)
- Greek curse tablets (1)
- H/D-Austausch (1)
- H/D-Exchange (1)
- H2020 (1)
- HDF5 (1)
- HERFD-XAS (1)
- HR-CS-MAS (1)
- Hamonisierung (1)
- Handheld (1)
- Harmonisierung (1)
- Hazardous substances (1)
- Heart attack (1)
- Heavy metals (1)
- Hierarchical cluster analysis (1)
- High repetition-rate (1)
- High-Speed Separations (1)
- High-entropy alloy (1)
- High-resolution synchrotron XRF (1)
- Histology (1)
- Holistic science (1)
- Host–guest systems (1)
- Human Plasma (1)
- Hydrogen (1)
- ILC on detection methods (1)
- IgG determination (1)
- Image manipulation (1)
- Immuno assay (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Implant material (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In situ studies (1)
- Inlet ionization (1)
- Instrument control (1)
- Instrumentation (1)
- Instrumentation utilization (1)
- Inter-laboratory comparison (1)
- Interner Standard (1)
- Ion mobility (1)
- Ionizing radiation (1)
- Iridium oxide (1)
- Klassifizierung (1)
- LA-ICP-MS (1)
- Laboratory automation (1)
- Laboratory management (1)
- Lacunary Keggin ion (1)
- Lead ions (1)
- Lead isotopes (1)
- Levitation (1)
- Li-ion battery (1)
- Luminol (1)
- MALDI (1)
- MALDI Imaging (1)
- MALDI Imaging MS (1)
- MALDI-TOF Massenspektrometrie (1)
- MALDI-ToF MS (1)
- MAS NMR spectroscopy (1)
- MCC (1)
- MDG ICP-ToF-MS (1)
- MOF (1)
- MOUSE (1)
- Machining (1)
- Macrocycles (1)
- Macrophagen (1)
- Magnetic nanocatalyst (1)
- Maia detector (1)
- Mass contents (1)
- Mass spectrometry (1)
- Massenspektrometrie (1)
- Material characterization (1)
- Matrices (1)
- Measurement data conversion (1)
- Mechanism (1)
- Mechanochemical synthesis (1)
- Metal nanoparticles (1)
- Metal-tag (1)
- Metformin (1)
- Methodenentwicklung Böden (1)
- Methodology (1)
- Metrics (1)
- Microdosimetry (1)
- Microdroplet generator (1)
- Microfluidic system (1)
- Microplastic analysis (1)
- Microplastic mass (1)
- Microplastic particles (1)
- Microplastic pathways (1)
- Microplastics analytic (1)
- Microplastics detection (1)
- Microplastics sampling (1)
- Microplastics standardisation (1)
- Mikroplastik Böden (1)
- Mikroplastik Massegehalt (1)
- Mikroplastik in Luft (1)
- Mikroplastikreferenzmaterial (1)
- Modelling (1)
- Molecular recognition (1)
- Molecule (1)
- Monitoring (1)
- Monoclonal Antibodies (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Monolithic column (1)
- Motor controller (1)
- Multimodal (1)
- Multivariate Analyse (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- Mycotoxin (1)
- Mycotoxins (1)
- NIR spectroscopy (1)
- NMR (1)
- NXsas (1)
- Nano (1)
- Nanocarrier (1)
- Nanocrystal (1)
- Nanomaterials (1)
- Nanoparticles (1)
- Nanoparticles with same nominal diameter (1)
- Nanoparticles with same nominal diameter; surface coating; two-dimensional off-line coupling (1)
- Nanoplastic (1)
- Nanoplastics (1)
- Natural language processing (1)
- NeXus (1)
- Near edge X-ray absorption fine structure spectroscopy (1)
- Nebra (1)
- Neural Network (1)
- Neural networks (1)
- Nondestructive testing techniques (1)
- OECD (1)
- Ochratoxin A (1)
- Online biosensor (1)
- Open Science (1)
- Optimierung (1)
- Outreach (1)
- P-aminothiophenol (1)
- PET (1)
- PXRD (1)
- Paper mills (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle size distribution (1)
- Pb isotopes (1)
- Peroxidase (1)
- Pharmacy (1)
- Phosphonate esters (1)
- Phosphonates (1)
- Photocatalysis (1)
- Photodegradation (1)
- Photooxidation (1)
- Plastic bottles (1)
- Pollen grains (1)
- Pollenkörner (1)
- Polycapillaries (1)
- Polyclonal Antibodies (1)
- Polyethyleneglycol (1)
- Polymer blends (1)
- Polymere Eigenschaften (1)
- Polymorph (1)
- Polymorphs (1)
- Polyoxometalates (1)
- Polyurethanes (1)
- Pomodore (1)
- Poster presentation (1)
- Principal component analysis (1)
- Principal component analysis (PCA) (1)
- Prisma (1)
- Probenpräparation (1)
- Procedure (1)
- Protein A (1)
- Protein Purification (1)
- Purification (1)
- Purity assessment (1)
- Python (1)
- Quality (1)
- Qualitätssicherung (1)
- Quantum dot (1)
- Quick-XAS (1)
- RUSEKU (1)
- RXES (1)
- Radiation (1)
- Radiation damage (1)
- Raman (1)
- Refractory alloys (1)
- Regeneration (1)
- Reifenabrieb (1)
- Release kinetics (1)
- Reliabiilty (1)
- Renewable Energy (1)
- Rhizopus (1)
- Ringversuch (1)
- Ringversuche (1)
- River (1)
- Robustness (1)
- Röntgenfluoreszenz (1)
- Salt (1)
- Sample preparation (1)
- Sata corrections (1)
- Scattering (1)
- Scientific misconduct (1)
- Sedimentation box (SB) (1)
- Sedimentationskasten (1)
- Sedimenttaionskasten (1)
- Self-assembly (1)
- Sensing (1)
- Separation (1)
- Sers (1)
- Si wafer filter (1)
- Silver nanoparticles (1)
- Sintered Material (1)
- Size (1)
- Size exclusion chromatography (1)
- Slags (1)
- Small-angle scattering (1)
- Soft-templated mesoporous films (1)
- Software (1)
- Solid support (1)
- Solvent-free (1)
- Sonochemical synthesis (1)
- Spinel (1)
- Sportböden (1)
- Supramolecular chemistry (1)
- Surface chemistry (1)
- Surface coating (1)
- Suspended particulate matter (SPM) (1)
- Sustainability and the Environment (1)
- TGA-FTIR (1)
- TGA-MS (1)
- TMB (1)
- TXRF-XAS (1)
- Tattoo inks (1)
- Temperature (1)
- Tesserae (1)
- Textile fibres (1)
- The MOUSE (1)
- Therapeutic Antibodies (1)
- Thermal analysis (1)
- Thermal degradation (1)
- Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS), monitoring (1)
- Thermal extraction-desorption gas chromatography mass spectrometry (1)
- Thermo-desorption (1)
- Thermoanalyse (1)
- Thermoanalysis (1)
- Thermoanalytic (1)
- Thermoanalytical methods (1)
- Thermoanalytics (1)
- Thermoanalytik (1)
- Tire Wear (1)
- Tire particles (1)
- Tools to combat scientific misconduct (1)
- Toxic metals (1)
- Traceability (1)
- Transesterification (1)
- Two-dimensional off-line coupling (1)
- Ultrasound (1)
- Underwater LIBS (1)
- Urban (1)
- VAMAS (1)
- VRF (1)
- Vacuum ionization (1)
- Validation (1)
- Vanadium redox flow battery (1)
- WAXS (1)
- Wastewater (1)
- Water samples (1)
- Welding (1)
- X-Ray Fluorescence (1)
- X-ray absorption spectroscopy (1)
- X-ray and electron diffraction (1)
- X-ray fluorescence spectroscopy (1)
- X-ray photoelectron spectroscopy (1)
- X-ray scattering (1)
- X-ray spectroscopy (1)
- XAS (1)
- Xerogel (1)
- Zearalenone (1)
- Zinc analysis (1)
- Zirconium (1)
- electrocatalysis (1)
- microplastics, sampling, sampling techniques, water (1)
- nanostructured (1)
- µJ-DPSS laser (1)
- Ägyptisches Museum Berlin (1)
Organisationseinheit der BAM
- 6 Materialchemie (197) (entfernen)
Paper des Monats
- ja (1)
Mechanochemistry provides polymorphs that are difficult to obtain by conventional solution-based methods. Based on the nicotinamide and pimelic acid cocrystal, we demonstrated that the ball size, frequency, and temperature are essential parameters. Our results indicate that fine-tuning the energy input during a mechanochemical reaction can provide control over polymorphism.
Quantitative Analysis and 2D/3D Elemental Imaging of Cocoa Beans Using X‑ray Fluorescence Techniques
(2023)
As an important raw material for the confectionery industry, the cocoa bean (Theobroma cacao L.) has to meet certain legal requirements in terms of food safety and maximum contaminant levels in order to enter the cocoa market. Understanding the enrichment and distribution of essential minerals but also toxic metals is of utmost importance for improving the nutritional quality of this economically important raw food material. We present three X-ray fluorescence (XRF) techniques for elemental bio-imaging of intact cocoa beans and one additional XRF technique for quantitative analysis of cocoa pellets. The interrelation of all the methods presented gives a detailed picture of the content and 3D-resolved distribution of elements in complete cocoa beans for the first time.
With increasing demand and environmental concerns, researchers are exploring new materials that can perform as well or better than traditional materials while reducing environmental impact. The BAMline, a real-life sample materials research beamline, provides unique insights into materials’ electronic and chemical structure at different time and length scales. The beamline specializes in x-ray absorption spectroscopy, x-ray fluorescence spectroscopy, and tomography experiments. This enables real-time optimization of material properties and performance for various applications, such as energy transfer, energy storage, catalysis, and corrosion resistance. This paper gives an overview of the analytical methods and sample environments of the BAMline, which cover non-destructive testing experiments in materials science, chemistry, biology, medicine, and cultural heritage. We also present our own synthesis methods, processes, and equipment developed specifically for the BAMline, and we give examples of synthesized materials and their potential applications. Finally, this article discusses the future perspectives of the BAMline and its potential for further advances in sustainable materials research.
Im Verbundprojekt RUSEKU wurde die Probenahme von Wasserproben entscheidend weiterentwickelt. Wichtig ist hierbei zu gewährleisten, dass genügend Merkmalsträger in jeder Probe untersucht werden. Es muss daher eine für den Probenahmeort repräsentative Beprobung hinsichtlich des Wasservolumens in Abhängigkeit der Partikelanzahl gewährleistet sein.
Das Hauptaugenmerk lag im vorliegenden Projekt auf einer praxisnahen Beprobungsstrategie. Es wurden verschiedene Konzepte ausprobiert.
• Grundsätzlich hat sich gezeigt, dass eine Stichprobe eine Momentaufnahme des MP-Massengehaltes zeigt. Es wird eine hohe Statistik, also eine Vielzahl an Messungen am gleichen Probenahmeort, benötigt, um eine valide Aussage über den MP-Gehalt zu machen.
• Es zeigt sich, dass eine integrale Probenahme über mehrere Wochen mit dem SK routinemäßig möglich ist. Die erfassten MP-Massen sind reproduzierbar und robust.
• Die DFZ ist für Stichproben geeignet. Partikel < 50 µm werden eventuell unterschätzt
• Die fraktionierte Filtration kann für Stich- und Mischproben direkt im Feld genutzt werden. Fraktionen von 10 und 5 µm werden später im Labor Vakuum filtriert. Es erfolgt eine Fraktionierung der Probe mit Siebmaschenweiten von 1000, 500, 100, 50, 10 und 5 µm.
• Die fraktionierte Filtration kann auch anschließend an die Beprobung mit dem SK zur Anwendung kommen. Wird die mit dem SK gewonnene Wasserprobe fraktioniert filtriert, kann neben einem MP-Gesamtgehalt auch eine Einschätzung über die Partikelgrößen gewonnen werden.
• Für Wässer mit geringen Partikelzahlen wurde ein Messfiltertiegel entwickelt. Dieser hat eine Maschenweite von 6 µm. Seine Anwendung kann mögliche Verluste beim Transferieren vom Probenahmetool zum Messgefäß und mögliche Kontaminationen reduzieren.
Die Optimierung der Probenahmestrategie wurde durch Modellversuche und Simulationen unterstützt. Modellversuche zum Sinkverhalten und Simulationen von MP in realen Gewässern verdeutlichten das komplexe Verhalten der Partikel. Es konnte gezeigt werden, dass Partikel ab einer bestimmten Größe (und kleiner) bei genügend starker Turbulenz sich in der Wassersäule unabhängig von ihrer Dichte verhalten und so auch MP mit kleiner Dichte (z.B. PE) in der gesamten Wassersäule zu finden sind. Es konnte mit dem TEM die Existenz von NP gezeigt werden.
Ein wesentlicher Aspekt des RUSEKU Projektes war die Beprobung realer Kompartimente. Beprobt wurde neben Oberflächengewässern, das urbane Abwassersystem der Stadt Kaiserslautern, Waschmaschinenabwasser und Flaschenwasser.
• In Oberflächengewässern wurde hauptsächlich PE gefunden. Je nach Probe und Gewässer konnten auch PP, PS, PET, PA, SBR und Acrylate nachgewiesen werden.
• Im urbanen Abwassersystem der Stadt Kaiserslautern konnte an allen Probenahmestandorten MP nachgewiesen werden. Es wurde hauptsächlich PE, neben geringeren Mengen an PP, PS und SBR gefunden. Nach einem Regenereignis war der SBR Anteil deutlich erhöht.
• Die Beprobung eines realen Wäschepostens, bestehend aus T-Shirts und Hemden mit PA/CO oder PES/CO Mischgewebe, zeigte einen PA- und PES-Austrag im Waschwasser. Der überwiegende Teil der detektierten Fasern ist aber auf Baumwolle zurückzuführen. Reine gravimetrische Messungen zur Detektion von MP führen zu einer starken Überschätzung.
• In Flaschenwasser (PET-Flaschen) konnte MP detektiert werden. PET wurde nur im stillen Mineralwasser, nicht in Mineralwasser mit Kohlensäure gefunden werden. Teilweise wurde auch das MP-Material des Verschlusses im Wasser detektiert.
• Für Luftproben konnte ein Aufbau zur größenselektiven Beprobung getestet werden.
Neben der Probenahme hat das Projekt auch gezeigt, dass die TED-GC/MS geeignet für die MP-Detektion im Routinebetrieb ist. Die TED-GC/MS konnte weiter optimiert werden. Es wurden MP-Massen bestimmt.
Im Projekt wurden erste realitätsnahe Referenzmaterialien für die MP Detektion hergestellt. Die Herstellung von realitätsnahen Polymeren in ausreichender Homogenität und Menge hat sich als große Herausforderung herausgestellt.
Cardiac troponin I (cTnI) is a crucial biomarker for diagnosing cardiac vascular diseases, including acute myocardial infarction (AMI). This study presents a proof-of-concept chemiluminescence-based immunosensor for rapid and accurate measurement of cTnI, with the potential for online monitoring. The immunosensor incorporates a flow cell design and a sensitive complementary metal-oxide-semiconductor (CMOS) camera for optical readout. A microfluidic setup was established to enable selective and quasi-online determination of cTnI within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer, demonstrating measurements in the concentration range of 2–25 µg/L, with a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) achieved using the optimized system. The immunosensor exhibited high selectivity, as no cross-reactivity was observed with other recombinant proteins such as cTnT and cTnC at a concentration of 16 µg/L. Measurements with diluted blood plasma and serum yielded an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively. This biosensor offers a promising approach for the rapid and sensitive detection of cTnI, contributing to the diagnosis and management of acute myocardial infarction and other cardiac vascular diseases.
Im der Präsentation werden, neben der Möglichkeit der Mikroplastikquantifizierung, auf weitere Anwendungsfelder der Methode TED-GC/MS eigegangen. Dies beinhaltet die Erfassung von Degradationsprodukten UV/O2 geschädigter Polymere und die Detektion von Additiven. Die Optimierung der Methode betreffend Messzeit und materialspezifischer Messanforderung sind ebenfalls Gegenstand.
Introduction to microplastics, definition, relevance, analytical approaches & challenges. TED-GC/MS working principle, features & performance. Optimisation in TED-GC/MS methodology, new validation data. Replacement of Internal Standard, outlook towards upcoming publication and application within EU´s revised drinking water directive.
This article describes the elaboration and characterization of diethylphosphonate-containing polymers coated electrodes as sensors for the detection of heavy metalstraces, by electrochemical impedance spectroscopy. Diethylphosphonate groupswere chosen as heavy metals binding sites. Two different series of polymers bearingthese anchoring groups were synthesized. Whereas the diethylphosphonate groupsare directly incorporated in the aromatic macromolecular chain in some polymers, analiphatic spacer is removing the chelating site from the polymer backbone in others.The influence of the macromolecular structure on the sensing response was studied,especially for the detection of Pb2+,Ni2+,Cd2+and Hg2+. Polymer P6, including thehigher amount of diethylphosphonate groups removed from the polymer chain by ashort alkyl spacer gave the higher sensitivity of detection of lead ions, with a detec-tion limit of 50 pM