Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Vortrag (90)
- Zeitschriftenartikel (72)
- Posterpräsentation (27)
- Forschungsdatensatz (3)
- Forschungsbericht (2)
- Buchkapitel (1)
- Beitrag zu einem Tagungsband (1)
- Preprint (1)
Sprache
- Englisch (156)
- Deutsch (40)
- Mehrsprachig (1)
Schlagworte
- Synchrotron (33)
- BAMline (30)
- Mikroplastik (29)
- TED-GC/MS (25)
- Microplastic (18)
- Microplastics (18)
- XRF (18)
- Mechanochemistry (10)
- TED-GC-MS (9)
- XANES (9)
- MALDI-TOF MS (8)
- Gold (7)
- Machine learning (7)
- Nanoparticle (6)
- Reference material (6)
- Analytik (5)
- Polymer 3R (5)
- XRD (5)
- Analysis (4)
- Automation (4)
- Bayesian Statistics (4)
- In situ (4)
- Pollen (4)
- Polylactide (4)
- Reference materials (4)
- Single cell analysis (4)
- TXRF (4)
- Water (4)
- Archaea (3)
- Coded Aperture (3)
- DNA (3)
- Dosimetry (3)
- Gaussian process (3)
- Machine Learning (3)
- Microbiologically influenced corrosion (3)
- Mikroplastik-Analytik (3)
- Nanoparticles separation capillary electrophoresis asymmetrcial flow field flow fractionation (3)
- Neural network (3)
- Probennahme (3)
- Referenzmaterialien (3)
- SAXS (3)
- Sampling (3)
- Sampling techniques (3)
- Standardisation (3)
- Tire wear (3)
- Trinkwasser (3)
- Affinity Chromatography (2)
- Aktivkohle (2)
- Amperometry (2)
- Analytic (2)
- Artificial Inelligence (2)
- Artificial intelligence (2)
- Asymmetrical flow field flow fractionation (AF4) (2)
- Batteries (2)
- Bayesian Optimization (2)
- Bioimaging (2)
- CXC (2)
- Capillary electrophoresis (2)
- Capillary electrophoresis (CE) (2)
- Certification (2)
- Crystalinity (2)
- D2XRF (2)
- EXAFS (2)
- FPLC (2)
- HPLC (2)
- Harmonisation (2)
- Homogeneity (2)
- ILC (2)
- Immunoassay (2)
- Internal Standard (2)
- Ionization (2)
- Lanthanide (2)
- MALDI TOF MS (2)
- Nanomaterial (2)
- Polymere (2)
- Polymers (2)
- Probenahme (2)
- Quality testing (2)
- Referenzmaterial (2)
- Risk assessment (2)
- SC-ICP-ToF-MS (2)
- Sc-ICP-ToF-MS (2)
- Soil (2)
- Spectroscopy (2)
- Stability (2)
- Standarisierung (2)
- Synthesis (2)
- Thermogravimetrie (2)
- Umwelt (2)
- Wasseraufbereitung (2)
- X-ray fluorescence (2)
- XAFS (2)
- A4F (1)
- AG nanoparticle (1)
- AU nanoparticle (1)
- Absorption spectrometry (1)
- Acidic oxygen evolution reaction (1)
- Acoustic levitation (1)
- Acute myocardial infarction (1)
- Additive (1)
- Additive Manufacturing (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Amyloid (1)
- Analyse (1)
- Analytical Sciences (1)
- Analytical standards (1)
- Antibodies (1)
- Antibody Purification (1)
- Antikensammlung Berlin (1)
- Application properties (1)
- Archaeometry (1)
- Archäometrie (1)
- Artificial Intelligence (1)
- Aspergillus (1)
- Atomic layer deposition (1)
- Aufbereitung (1)
- Automated Purification (1)
- Barium (1)
- Battery (1)
- Bayes (1)
- Bbeverages (1)
- Beamline (1)
- Bernstorf (1)
- Biological & biomedical applications (1)
- Biomarker (1)
- Biosensor (1)
- Biosynthesis (1)
- Bismuth (1)
- Bisphenol A (1)
- Bone matrix (1)
- Borosilicate Glass (1)
- Böden (1)
- CCQM key comparison (1)
- Calcium monofluoride (1)
- Carboxyl group (1)
- Cardiac troponin (1)
- Cascade filtration (1)
- Catalysts (1)
- Cathode material (1)
- Causes leading to scientific misconduct (1)
- Channel access (1)
- Chemical composition (1)
- Chemical transformation (1)
- Chemiluminescence (1)
- Citizen Science (1)
- Classification (1)
- Cobalt deposition (1)
- Cocoa (1)
- Cocrystal (1)
- Color X-ray Camera (1)
- Column holder (1)
- Comparative test (1)
- Compost (1)
- Concentration step (1)
- Conjugate (1)
- Construction (1)
- Coordination polymers (1)
- Core-shell nanoparticles (1)
- Core/shell nanoparticle (1)
- Corrosion (1)
- Coupling reactions (1)
- Crystallization (1)
- Cyclic voltammetry (1)
- Cyclization (1)
- Cycloparaphenylenes (1)
- Cylic Voltammetry (1)
- DNA strand break (1)
- Data conversion (1)
- Data manipulation (1)
- Debye-Waller parameter (1)
- Deep work (1)
- Degradation (1)
- Density separation (1)
- Depth profile (1)
- Desorption (1)
- Detektion (1)
- Detektion von Mikroplastik (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Digital laboratory (1)
- Digitalization (1)
- Dispersive-XAS (1)
- Dose (1)
- Down Stream Processing (1)
- EPICS (1)
- Ectoine (1)
- Ectoine radiation protection (1)
- Egypt (1)
- Electrocatalysis (1)
- Electrochemistry (1)
- Electrohpresis (1)
- Elektronenmikroskopie (1)
- Emergency (1)
- Endocrine disruptor (1)
- Energy input (1)
- Energy storage (1)
- Environmental analysis (1)
- Environmental impacts (1)
- Epoxy (1)
- Extended X-ray absorption fine structure (1)
- FTIR (1)
- Farbenlehre (1)
- Fenton (1)
- Filter crucible (1)
- Filtration (1)
- Flow injection immunoassay (1)
- Fluorescence (1)
- Fluorine (1)
- Folic acid (1)
- Food safety (1)
- Fraktionierte Filtration (1)
- Framework (1)
- Fundamentals (1)
- Fusarium (1)
- GUI (1)
- Gaussian Process (1)
- General Chemistry (1)
- General Materials Science (1)
- Gilding (1)
- Glass (1)
- Glass Support (1)
- Goethe (1)
- Graphite furnace (1)
- Greek curse tablets (1)
- H/D-Austausch (1)
- H/D-Exchange (1)
- H2020 (1)
- HDF5 (1)
- HERFD-XAS (1)
- HR-CS-MAS (1)
- Hamonisierung (1)
- Handheld (1)
- Harmonisierung (1)
- Hazardous substances (1)
- Heart attack (1)
- Heavy metals (1)
- Hierarchical cluster analysis (1)
- High repetition-rate (1)
- High-Speed Separations (1)
- High-entropy alloy (1)
- High-resolution synchrotron XRF (1)
- Histology (1)
- Holistic science (1)
- Host–guest systems (1)
- Human Plasma (1)
- Hydrogen (1)
- ILC on detection methods (1)
- IgG determination (1)
- Image manipulation (1)
- Immuno assay (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Implant material (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In situ studies (1)
- Inlet ionization (1)
- Instrument control (1)
- Instrumentation (1)
- Instrumentation utilization (1)
- Inter-laboratory comparison (1)
- Interner Standard (1)
- Ion mobility (1)
- Ionizing radiation (1)
- Iridium oxide (1)
- Klassifizierung (1)
- LA-ICP-MS (1)
- Laboratory automation (1)
- Laboratory management (1)
- Lacunary Keggin ion (1)
- Lead ions (1)
- Lead isotopes (1)
- Levitation (1)
- Li-ion battery (1)
- Luminol (1)
- MALDI (1)
- MALDI Imaging (1)
- MALDI Imaging MS (1)
- MALDI-TOF Massenspektrometrie (1)
- MALDI-ToF MS (1)
- MAS NMR spectroscopy (1)
- MCC (1)
- MDG ICP-ToF-MS (1)
- MOF (1)
- MOUSE (1)
- Machining (1)
- Macrocycles (1)
- Macrophagen (1)
- Magnetic nanocatalyst (1)
- Maia detector (1)
- Mass contents (1)
- Mass spectrometry (1)
- Massenspektrometrie (1)
- Material characterization (1)
- Matrices (1)
- Measurement data conversion (1)
- Mechanism (1)
- Mechanochemical synthesis (1)
- Metal nanoparticles (1)
- Metal-tag (1)
- Metformin (1)
- Methodenentwicklung Böden (1)
- Methodology (1)
- Metrics (1)
- Microdosimetry (1)
- Microdroplet generator (1)
- Microfluidic system (1)
- Microplastic analysis (1)
- Microplastic mass (1)
- Microplastic particles (1)
- Microplastic pathways (1)
- Microplastics analytic (1)
- Microplastics detection (1)
- Microplastics sampling (1)
- Microplastics standardisation (1)
- Mikroplastik Böden (1)
- Mikroplastik Massegehalt (1)
- Mikroplastik in Luft (1)
- Mikroplastikreferenzmaterial (1)
- Modelling (1)
- Molecular recognition (1)
- Molecule (1)
- Monitoring (1)
- Monoclonal Antibodies (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Monolithic column (1)
- Motor controller (1)
- Multimodal (1)
- Multivariate Analyse (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- Mycotoxin (1)
- Mycotoxins (1)
- NIR spectroscopy (1)
- NMR (1)
- NXsas (1)
- Nano (1)
- Nanocarrier (1)
- Nanocrystal (1)
- Nanomaterials (1)
- Nanoparticles (1)
- Nanoparticles with same nominal diameter (1)
- Nanoparticles with same nominal diameter; surface coating; two-dimensional off-line coupling (1)
- Nanoplastic (1)
- Nanoplastics (1)
- Natural language processing (1)
- NeXus (1)
- Near edge X-ray absorption fine structure spectroscopy (1)
- Nebra (1)
- Neural Network (1)
- Neural networks (1)
- Nondestructive testing techniques (1)
- OECD (1)
- Ochratoxin A (1)
- Online biosensor (1)
- Open Science (1)
- Optimierung (1)
- Outreach (1)
- P-aminothiophenol (1)
- PET (1)
- PXRD (1)
- Paper mills (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle size distribution (1)
- Pb isotopes (1)
- Peroxidase (1)
- Pharmacy (1)
- Phosphonate esters (1)
- Phosphonates (1)
- Photocatalysis (1)
- Photodegradation (1)
- Photooxidation (1)
- Plastic bottles (1)
- Pollen grains (1)
- Pollenkörner (1)
- Polycapillaries (1)
- Polyclonal Antibodies (1)
- Polyethyleneglycol (1)
- Polymer blends (1)
- Polymere Eigenschaften (1)
- Polymorph (1)
- Polymorphs (1)
- Polyoxometalates (1)
- Polyurethanes (1)
- Pomodore (1)
- Poster presentation (1)
- Principal component analysis (1)
- Principal component analysis (PCA) (1)
- Prisma (1)
- Probenpräparation (1)
- Procedure (1)
- Protein A (1)
- Protein Purification (1)
- Purification (1)
- Purity assessment (1)
- Python (1)
- Quality (1)
- Qualitätssicherung (1)
- Quantum dot (1)
- Quick-XAS (1)
- RUSEKU (1)
- RXES (1)
- Radiation (1)
- Radiation damage (1)
- Raman (1)
- Refractory alloys (1)
- Regeneration (1)
- Reifenabrieb (1)
- Release kinetics (1)
- Reliabiilty (1)
- Renewable Energy (1)
- Rhizopus (1)
- Ringversuch (1)
- Ringversuche (1)
- River (1)
- Robustness (1)
- Röntgenfluoreszenz (1)
- Salt (1)
- Sample preparation (1)
- Sata corrections (1)
- Scattering (1)
- Scientific misconduct (1)
- Sedimentation box (SB) (1)
- Sedimentationskasten (1)
- Sedimenttaionskasten (1)
- Self-assembly (1)
- Sensing (1)
- Separation (1)
- Sers (1)
- Si wafer filter (1)
- Silver nanoparticles (1)
- Sintered Material (1)
- Size (1)
- Size exclusion chromatography (1)
- Slags (1)
- Small-angle scattering (1)
- Soft-templated mesoporous films (1)
- Software (1)
- Solid support (1)
- Solvent-free (1)
- Sonochemical synthesis (1)
- Spinel (1)
- Sportböden (1)
- Supramolecular chemistry (1)
- Surface chemistry (1)
- Surface coating (1)
- Suspended particulate matter (SPM) (1)
- Sustainability and the Environment (1)
- TGA-FTIR (1)
- TGA-MS (1)
- TMB (1)
- TXRF-XAS (1)
- Tattoo inks (1)
- Temperature (1)
- Tesserae (1)
- Textile fibres (1)
- The MOUSE (1)
- Therapeutic Antibodies (1)
- Thermal analysis (1)
- Thermal degradation (1)
- Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS), monitoring (1)
- Thermal extraction-desorption gas chromatography mass spectrometry (1)
- Thermo-desorption (1)
- Thermoanalyse (1)
- Thermoanalysis (1)
- Thermoanalytic (1)
- Thermoanalytical methods (1)
- Thermoanalytics (1)
- Thermoanalytik (1)
- Tire Wear (1)
- Tire particles (1)
- Tools to combat scientific misconduct (1)
- Toxic metals (1)
- Traceability (1)
- Transesterification (1)
- Two-dimensional off-line coupling (1)
- Ultrasound (1)
- Underwater LIBS (1)
- Urban (1)
- VAMAS (1)
- VRF (1)
- Vacuum ionization (1)
- Validation (1)
- Vanadium redox flow battery (1)
- WAXS (1)
- Wastewater (1)
- Water samples (1)
- Welding (1)
- X-Ray Fluorescence (1)
- X-ray absorption spectroscopy (1)
- X-ray and electron diffraction (1)
- X-ray fluorescence spectroscopy (1)
- X-ray photoelectron spectroscopy (1)
- X-ray scattering (1)
- X-ray spectroscopy (1)
- XAS (1)
- Xerogel (1)
- Zearalenone (1)
- Zinc analysis (1)
- Zirconium (1)
- electrocatalysis (1)
- microplastics, sampling, sampling techniques, water (1)
- nanostructured (1)
- µJ-DPSS laser (1)
- Ägyptisches Museum Berlin (1)
Organisationseinheit der BAM
- 6 Materialchemie (197) (entfernen)
Paper des Monats
- ja (1)
To gain insight into the possible origin of the gold used in the production of tesserae containing gold leaf less than 0.5 μm thick placed between two layers of glass, we propose a non-destructive synchrotron radiation (SR) XRF protocol based on sequential analysis under optimised analytical conditions. Using this protocol, trace element analysis is achieved with detection limits of 1–6 mg/kg. As Pt and Au have adjacent fluorescence energies, we tested the most challenging situation, when Pt is present in very low concentrations in gold. Data obtained by double-dispersive XRF (D2XRF) and μXRF for fourth–ninth-century mosaics decorating nine Eastern and Western religious buildings show that the Eastern and Western tesserae are made from different alloys.
However, these alloys are identical to those used to make gold leaf for gilding, because plastic deformation requires the use of gold alloys with high ductility and malleability. Although trace element composition of gold used in the concerned period is only available for coins, by comparing the amounts of Pt contained in the tesserae and in the coins we show that Roman tesserae are made from Roman gold, as described in the documentary sources. We observe for the Byzantine period the use of a Byzantine gold and of gold supposedly from different stages of recycling, and we suggest the use of Umayyad and Abbasid gold for the production of Islamic tesserae.
By automatically recording as much information as possible in automated laboratory setups, reproducibility and traceability of experiments are vastly improved. This presentation shows what such an approach means for the quality of experiments in an X-ray scattering laboratory and an automated synthesis set-up.
Getting more efficient – The use of Bayesian optimization and Gaussian processes at the BAMline
(2022)
For more than 20 years, BAM is operating the BAMline at the synchrotron BESSY II in Berlin Adlershof. During this time, the complexity of the setup and the amount of data generated have multiplied. To increase the effectiveness and in preparation for BESSY III, algorithms from the field of machine learning are increasingly used.
After a short introduction to BO and GP, the first example is the automatic alignment of our double multilayer monochromator (DMM).
The second example is the optimization of measurement time in XRF scanning.
Exceptional ion mobility spectrometry mass spectrometry (IMS-MS) developments by von Helden, Jarrold, and Clemmer provided technology that gives a view of chemical/biological compositions previously not achievable. The ionization method of choice used with IMS-MS has been electrospray ionization (ESI). In this Special issue contribution, we focus on fundamentals of heretofore unprecedented means for transferring volatile and nonvolatile compounds into gas-phase ions singly and multiply charged. These newer ionization processes frequently lead to different selectivity relative to ESI and, together with IMS-MS, may provide a more comprehensive view of chemical compositions directly from their original Environment such as surfaces, e.g., tissue. Similarities of results using solvent- and matrix-assisted ionization are highlighted, as are differences between ESI and the inlet ionization methods, especially with mixtures such as bacterial extracts. Selectivity using different matrices is discussed, as are results which add to our fundamental knowledge of inlet ionization as well as pose additional avenues for inquiry. IMS-MS provides an opportunity for comparison studies relative to ESI and will prove valuable using the new ionization technologies for direct analyses. Our hypothesis is that some ESI-IMS-MS applications will be replaced by the new ionization processes and by understanding mechanistic aspects to aid enhanced source and method developments this will be hastened.
With the online coupling (or hyphenation) of chemically-resolved spectroscopy detection with classical size-exclusion chromatography (SEC) it is possible to correlate polymer molecular size with chemical structure in a single in-situ or on-flow measurement. Medium-resolution 1H-NMR (60 MHz) spectroscopy (i.e., “desktop NMR”) and Fouriertransform Infrared Spectroscopy (FTIR) have both been developed as coupled methods (SEC-MR-NMR, SEC-FTIR) for the detection of polymer analytes by monitoring e.g. alkene or carbonyl functionality.1,2 Here, we have investigated the potential for the detection of polymer end groups, using a slightly higher field-strength spectrometer (80 MHz 1H Larmor frequency) and taking advantage of a columnless injection method that provides bulk spectra for reference. End-functionalized polymers were synthesized by reaction of PEG with toluene isocyanate, yielding ,-functionalized polymers with exactly 2 IR- and NMR-detectable functional groups per chain, as proven by MALD-TOF mass spectrometry. We have investigated the sensitivity (limit of detection) and spectral resolution for these functional groups in chloroform, THF, and water. Results have demonstrated a good feasibility for the simultaneous online detection of PEG backbone (M~4000 g/mol) and these end groups at the level of ca. 2 mol%.
Cost-effective water cleaning approaches using improved Treatment technologies, for instance based on catalytic processes with high activity catalysts, are urgently needed. The aim of our study was to synthesize efficient Fenton-like photo-catalysts for rapid degradation of persistent organic micropollutants in aqueous medium. Iron-based nanomaterials were chemically synthesized through simple procedures by immobilization of either iron(II) oxalate (FeO) or iron(III) citrate (FeC) on magnetite (M) nanoparticles stabilized with polyethylene glycol (PEG). Various investigation techniques were performed in order to characterize the freshly prepared catalysts. By applying advanced oxidation processes, the effect of catalyst dosage, hydrogen peroxide concentration and UV-A light exposure were examined for Bisphenol A (BPA) conversion, at laboratory scale, in mild conditions. The obtained results revealed that BPA degradation was rapidly enhanced in the presence of low-concentration H2O2, as well as under UV-A light, and is highly dependent on the surface characteristics of the catalyst. Complete photo-degradation of BPA was achieved over the M/PEG/FeO catalyst in less than 15 minutes. Based on the catalytic performance, a hierarchy of the tested catalysts was established: M/PEG/FeO > M/PEG/FeC > M/PEG. The results of cytotoxicity assay using MCF-7 cells indicated that the aqueous samples after treatment are less cytotoxic.
Gold is one of the seven metals already known in antiquity and was used from time immemorial as a medium of exchange and for the production of jewelry because of its luster and rarity. In addition, it is easy to work and largely resistant to chemical influences. Investigations of gold using synchrotron radiation excited X-ray fluorescence analysis are non-destructive and provide information about the chemical elements present in the sample under investigation. The investigations presented here at BAMline focus on questions such as the origin, manufacturing process, and association of gold findings. The different questions are explained by a number of examples ranging from the Viking treasure from Hiddensee to the Nebra Sky Disk and finds from Egypt. The find from Bernstorf is discussed in detail. A Bayesian treatment of the authenticity is shown.
Formation Mechanism of a Nano-Ring of Bismuth Cations and Mono-Lacunary Keggin-Type Phosphomolybdate
(2022)
A new hetero-bimetallic polyoxometalate (POM) nano-ring was synthesized in a one-pot procedure. The structure consists of tetrameric units containing four bismuth-substituted monolacunary Keggin anions including distorted [BiO8] cubes. The nano-ring is formed via self-assembly from metal precursors in aqueous acidic medium. The compound (NH4)16[(BiPMo11O39)4] ⋅ 22 H2O; (P4Bi4Mo44) was characterized by single-crystal X-ray diffraction, extended X-ray absorption fine structure spectroscopy (EXAFS), Raman spectroscopy, matrix-assisted laser desorption/ionisation-time of flight mass spectrometry (MALDI-TOF), and thermogravimetry/differential scanning calorimetry mass spectrometry (TG-DSC-MS). The formation of the nano-ring in solution was studied by time-resolved in situ small- and wide-angle X-ray scattering (SAXS/WAXS) and in situ EXAFS measurements at the Mo−K and the Bi−L3 edge indicating a two-step process consisting of condensation of Mo-anions and formation of Bi−Mo-units followed by a rapid self-assembly to yield the final tetrameric ring structure.
Fast quantitative detection of microplastics using TED-GC/MS, an innovative thermoanalytical method
(2021)
In the talk, the BAM is introduced and the motivation for our engagement in the field of microplastic analysis is explained. The challenges in the analysis of microplastics are shown and how we deal with them. The working principle of TED-GC/MS and its performance parameters are presented, as well as the procedure for identifying and quantifying polymers in environmental samples. Interesting results are shown using selected examples. Finally, BAM's microplastic reference materials are highlighted.
EXAFS analysis of pure elements, binary and ternary equiatomic refractory alloys within the Nb-Zr-Ti-Hf- Ta system is performed at the Nb and Zr K-edges to analyze the evolution of the chemical local environ- ment and the lattice distortion. A good mixing of the elements is found at the atomic scale. For some compounds, a distribution of distances between the central atom and its neighbors suggests a distortion of the structure. Finally, analysis of the Debye-Waller parameters shows some correlation with the lat- tice distortion parameter δ², and allows to quantify experimentally the static disorder in medium entropy alloys.
This is a set of use examples for the HDF5Translator framework. This framework lets you translate measurement files into a different (e.g. NeXus-compatible) structure, with some optional checks and conversions on the way. For an in-depth look at what it does, there is a blog post here.
The use examples provided herein are each accompanied by the measurement data necessary to test and replicate the conversion. The README.md files in each example show the steps necessary to do the conversion for each.
We encourage those who have used or adapted one or more of these exampes to create their own conversion, to get in touch with us so we may add your example to the set.
Up to now, different analytical methods for single cell analysis exist focusing on key features such as size, shape, morphology and elemental composition. The combination of the latest ICP-MS techniques - ICP-ToF-MS - together with the latest developments in the field of sample delivery - micro droplet generator (MDG) – will allow a Deep insight into the composition and size of cells.
Microbiologically influenced corrosion (MIC) is an oxidation of metals affected by the presence or activity (or both) of microorganisms e.g. Shewanella Putrefaciens in biofilms on the surface of the corroding material. As this can happen for example in the soil on iron pipes of water pipes, in oil tanks or on steel sheet piling, there is great interest in MIC research, not only from various industrial sectors, but also from the environmental aspect.
Microplastic particles are currently detected in almost all environmental compartments. The results of detection vary widely, as a multitude of very different methods are used with very different requirements for analytical validity.
In this work four thermoanalytical methods are compared and their advantages and limitations are discussed. One of them is thermal extraction-desorption gas chromatography mass spectrometry (TED-GC/MS), an analysis method for microplastic detection that has become established in recent years. In addition, thermogravimetric analysis coupled with Fourier-transform infrared spectroscopy (TGA-FTIR) and mass spectrometry (TGA-MS) were applied, two methods that are less common in this field but are still used in other research areas. Finally, microscale combustion calorimeter (MCC) was applied, a method not yet used for microplastic detection.
The presented results are taken from a recently published interlaboratory comparison test by Becker et al. (2020). Here a reference material consisting of suspended matter and specified added polymer masses was examined, and only the results of the recoveries were presented. In the present paper, however, the results for the individual polymers are discussed in detail and individual perspectives for all instruments are shown.
It was found that TED-GC/MS is the most suitable method for samples with unknown matrix and unknown, variable kinds and contents of microplastic. TGA-FTIR is a robust method for samples with known matrix and with defined kinds of microplastic. TGA-MS may offer a solution for the detection of PVC particles in the future. MCC can be used as a very fast and simple screening method for the identification of a potential microplastic load of standard polymers in unknown samples.
Im der Präsentation werden, neben der Möglichkeit der Mikroplastikquantifizierung, auf weitere Anwendungsfelder der Methode TED-GC/MS eigegangen. Dies beinhaltet die Erfassung von Degradationsprodukten UV/O2 geschädigter Polymere und die Detektion von Additiven. Die Optimierung der Methode betreffend Messzeit und materialspezifischer Messanforderung sind ebenfalls Gegenstand.
Enhancing efficiency at bamline: employing data science and machine learning for x-ray research
(2023)
This talk discusses how data science and machine learning techniques are being applied at the BAM Federal Institute for Materials Research and Testing to enhance efficiency and automation at the BAMLine synchrotron facility. The methods presented include Gaussian processes and Bayesian optimization for beamline adjustment and optimization of X-ray measurements. These statistical techniques allow automated alignment of beamline components and active learning scanning to reduce measurement time.
Additional machine learning methods covered are neural networks for quantification of X-ray fluorescence (XRF) data and decoding coded apertures.
Our aim is to develop a simple and inexpensive method for full field X-ray fluorescence imaging.We combine an energydispersive array detector with a coded aperture to obtain high resolut ion images. To obtain the information from the recorded image a reconstruction step is necessary. The reconstruction methods we have developed, were tested on simulated data and then applied to experimental data. The first tests were carried out at the BAMline @BESSY II. This method enables the simultaneous detection of multiple elements,which is important e.g. in the field of catalysis.
Polymer electrolyte membranes (PEM) are polymers which act as separator in an electrochemical cell and allow ionic charge flow to close the circuit. Widely used membranes are perfluorinated sulfonic-acid (PFSA) ionomers (e.g. Nafion™), a class of ion-conducting polymers with remarkable ion conductivity and chemical-mechanical stability. A nanoscopic water system around the sulfonic acid capped side-chains of the otherwise hydrophobic polymer allows the ion transport. Only approx. 14 molecules of water per sulfonic group are present in the fully hydrated state. In vanadium redox flow batteries (VRFB) ideally only protons are transported. The weak ion selectivity of Nafion™ is the main cause for the transportation of vanadium, briefly vanadium crossover, in VRFBs a system we have investigated more closely, lately. The consequences of crossover are a concentration imbalance and a self-discharge of the battery, which leads to a decrease of the capacity. The development of efficient energy storage systems is crucial for the transformation towards a renewable energy based economy. The VRFB has a great potential as a commercial electrochemical energy storage system due to properties including, but not limited to, no cross-contamination, a long cycle-life and a theoretically unlimited capacity. VRFB consists of two half-cells, which are linked to electrolyte tanks and separated by a membrane. The membrane plays a major role in overall cell performance. So far, vanadium transportation models, which include diffusion, migration, electroosmotic convection and pressure gradients, are inconsistent. There is no agreement in the literature on the diffusion coefficients of vanadium species (e.g. published diffusion coefficients of V2+ are located between 3.13·10-12 m²s-1 and 9.44·10-12 m²s-1) indicate that thevanadium crossover is not well understood and there is a lack on a more fundamental level. Since the membrane transport is the rate-determining step of the crossover as well as of the proton exchange it is extremely important to understand these phenomena on a fundamental level. This will eventually allow us to design better membranes. Alternative materials need to show equivalent performance compared with Nafion™ and ideally be more selective regarding ion cross-membrane transport.There are several options to approach the chemistry i.e. the interaction of dissolved and bound ions inside the confined water body of ionomeric membranes. Vanadium ions are a versatile model as UV/VIS data can be used to distinguish between the 5 species V2+, V3+, VO2+, VO2+ and V2O33+ of the electrolyte. Infrared spectroscopy has been applied to study the interaction of sulfonic groups and the ions. Molecular dynamic modeling is another approach to study the distribution and distances of ions. We now introduce X-ray absorption near edge structure spectroscopy (XANES) to study species and species changes inside Nafion™ and a novel membrane based on poly(1,1-difluoroethylene) (PVDF). We evaluated the methods and investigated the influence of irradiation, temperature and hydration on the measurements.
Electrochemical methods offer great promise in meeting the demand for user-friendly on-site devices for Monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme-linked immunosorbent assays, with photometric detection of 3,3’,5,5’-tetramethylbenzidine (TMB),form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detectionstep, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphonebased, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis forsensing of further analytes.