Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Vortrag (91)
- Zeitschriftenartikel (72)
- Posterpräsentation (27)
- Forschungsdatensatz (4)
- Forschungsbericht (2)
- Buchkapitel (1)
- Beitrag zu einem Tagungsband (1)
- Preprint (1)
Sprache
- Englisch (158)
- Deutsch (40)
- Mehrsprachig (1)
Schlagworte
- Synchrotron (33)
- BAMline (30)
- Mikroplastik (29)
- TED-GC/MS (25)
- Microplastics (19)
- Microplastic (18)
- XRF (18)
- Mechanochemistry (10)
- MALDI-TOF MS (9)
- TED-GC-MS (9)
Organisationseinheit der BAM
- 6 Materialchemie (199) (entfernen)
Paper des Monats
- ja (1)
To gain insight into the possible origin of the gold used in the production of tesserae containing gold leaf less than 0.5 μm thick placed between two layers of glass, we propose a non-destructive synchrotron radiation (SR) XRF protocol based on sequential analysis under optimised analytical conditions. Using this protocol, trace element analysis is achieved with detection limits of 1–6 mg/kg. As Pt and Au have adjacent fluorescence energies, we tested the most challenging situation, when Pt is present in very low concentrations in gold. Data obtained by double-dispersive XRF (D2XRF) and μXRF for fourth–ninth-century mosaics decorating nine Eastern and Western religious buildings show that the Eastern and Western tesserae are made from different alloys.
However, these alloys are identical to those used to make gold leaf for gilding, because plastic deformation requires the use of gold alloys with high ductility and malleability. Although trace element composition of gold used in the concerned period is only available for coins, by comparing the amounts of Pt contained in the tesserae and in the coins we show that Roman tesserae are made from Roman gold, as described in the documentary sources. We observe for the Byzantine period the use of a Byzantine gold and of gold supposedly from different stages of recycling, and we suggest the use of Umayyad and Abbasid gold for the production of Islamic tesserae.
By automatically recording as much information as possible in automated laboratory setups, reproducibility and traceability of experiments are vastly improved. This presentation shows what such an approach means for the quality of experiments in an X-ray scattering laboratory and an automated synthesis set-up.
Getting more efficient – The use of Bayesian optimization and Gaussian processes at the BAMline
(2022)
For more than 20 years, BAM is operating the BAMline at the synchrotron BESSY II in Berlin Adlershof. During this time, the complexity of the setup and the amount of data generated have multiplied. To increase the effectiveness and in preparation for BESSY III, algorithms from the field of machine learning are increasingly used.
After a short introduction to BO and GP, the first example is the automatic alignment of our double multilayer monochromator (DMM).
The second example is the optimization of measurement time in XRF scanning.
Exceptional ion mobility spectrometry mass spectrometry (IMS-MS) developments by von Helden, Jarrold, and Clemmer provided technology that gives a view of chemical/biological compositions previously not achievable. The ionization method of choice used with IMS-MS has been electrospray ionization (ESI). In this Special issue contribution, we focus on fundamentals of heretofore unprecedented means for transferring volatile and nonvolatile compounds into gas-phase ions singly and multiply charged. These newer ionization processes frequently lead to different selectivity relative to ESI and, together with IMS-MS, may provide a more comprehensive view of chemical compositions directly from their original Environment such as surfaces, e.g., tissue. Similarities of results using solvent- and matrix-assisted ionization are highlighted, as are differences between ESI and the inlet ionization methods, especially with mixtures such as bacterial extracts. Selectivity using different matrices is discussed, as are results which add to our fundamental knowledge of inlet ionization as well as pose additional avenues for inquiry. IMS-MS provides an opportunity for comparison studies relative to ESI and will prove valuable using the new ionization technologies for direct analyses. Our hypothesis is that some ESI-IMS-MS applications will be replaced by the new ionization processes and by understanding mechanistic aspects to aid enhanced source and method developments this will be hastened.
With the online coupling (or hyphenation) of chemically-resolved spectroscopy detection with classical size-exclusion chromatography (SEC) it is possible to correlate polymer molecular size with chemical structure in a single in-situ or on-flow measurement. Medium-resolution 1H-NMR (60 MHz) spectroscopy (i.e., “desktop NMR”) and Fouriertransform Infrared Spectroscopy (FTIR) have both been developed as coupled methods (SEC-MR-NMR, SEC-FTIR) for the detection of polymer analytes by monitoring e.g. alkene or carbonyl functionality.1,2 Here, we have investigated the potential for the detection of polymer end groups, using a slightly higher field-strength spectrometer (80 MHz 1H Larmor frequency) and taking advantage of a columnless injection method that provides bulk spectra for reference. End-functionalized polymers were synthesized by reaction of PEG with toluene isocyanate, yielding ,-functionalized polymers with exactly 2 IR- and NMR-detectable functional groups per chain, as proven by MALD-TOF mass spectrometry. We have investigated the sensitivity (limit of detection) and spectral resolution for these functional groups in chloroform, THF, and water. Results have demonstrated a good feasibility for the simultaneous online detection of PEG backbone (M~4000 g/mol) and these end groups at the level of ca. 2 mol%.
Cost-effective water cleaning approaches using improved Treatment technologies, for instance based on catalytic processes with high activity catalysts, are urgently needed. The aim of our study was to synthesize efficient Fenton-like photo-catalysts for rapid degradation of persistent organic micropollutants in aqueous medium. Iron-based nanomaterials were chemically synthesized through simple procedures by immobilization of either iron(II) oxalate (FeO) or iron(III) citrate (FeC) on magnetite (M) nanoparticles stabilized with polyethylene glycol (PEG). Various investigation techniques were performed in order to characterize the freshly prepared catalysts. By applying advanced oxidation processes, the effect of catalyst dosage, hydrogen peroxide concentration and UV-A light exposure were examined for Bisphenol A (BPA) conversion, at laboratory scale, in mild conditions. The obtained results revealed that BPA degradation was rapidly enhanced in the presence of low-concentration H2O2, as well as under UV-A light, and is highly dependent on the surface characteristics of the catalyst. Complete photo-degradation of BPA was achieved over the M/PEG/FeO catalyst in less than 15 minutes. Based on the catalytic performance, a hierarchy of the tested catalysts was established: M/PEG/FeO > M/PEG/FeC > M/PEG. The results of cytotoxicity assay using MCF-7 cells indicated that the aqueous samples after treatment are less cytotoxic.
Gold is one of the seven metals already known in antiquity and was used from time immemorial as a medium of exchange and for the production of jewelry because of its luster and rarity. In addition, it is easy to work and largely resistant to chemical influences. Investigations of gold using synchrotron radiation excited X-ray fluorescence analysis are non-destructive and provide information about the chemical elements present in the sample under investigation. The investigations presented here at BAMline focus on questions such as the origin, manufacturing process, and association of gold findings. The different questions are explained by a number of examples ranging from the Viking treasure from Hiddensee to the Nebra Sky Disk and finds from Egypt. The find from Bernstorf is discussed in detail. A Bayesian treatment of the authenticity is shown.
Formation Mechanism of a Nano-Ring of Bismuth Cations and Mono-Lacunary Keggin-Type Phosphomolybdate
(2022)
A new hetero-bimetallic polyoxometalate (POM) nano-ring was synthesized in a one-pot procedure. The structure consists of tetrameric units containing four bismuth-substituted monolacunary Keggin anions including distorted [BiO8] cubes. The nano-ring is formed via self-assembly from metal precursors in aqueous acidic medium. The compound (NH4)16[(BiPMo11O39)4] ⋅ 22 H2O; (P4Bi4Mo44) was characterized by single-crystal X-ray diffraction, extended X-ray absorption fine structure spectroscopy (EXAFS), Raman spectroscopy, matrix-assisted laser desorption/ionisation-time of flight mass spectrometry (MALDI-TOF), and thermogravimetry/differential scanning calorimetry mass spectrometry (TG-DSC-MS). The formation of the nano-ring in solution was studied by time-resolved in situ small- and wide-angle X-ray scattering (SAXS/WAXS) and in situ EXAFS measurements at the Mo−K and the Bi−L3 edge indicating a two-step process consisting of condensation of Mo-anions and formation of Bi−Mo-units followed by a rapid self-assembly to yield the final tetrameric ring structure.
Fast quantitative detection of microplastics using TED-GC/MS, an innovative thermoanalytical method
(2021)
In the talk, the BAM is introduced and the motivation for our engagement in the field of microplastic analysis is explained. The challenges in the analysis of microplastics are shown and how we deal with them. The working principle of TED-GC/MS and its performance parameters are presented, as well as the procedure for identifying and quantifying polymers in environmental samples. Interesting results are shown using selected examples. Finally, BAM's microplastic reference materials are highlighted.