Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Vortrag (90)
- Zeitschriftenartikel (72)
- Posterpräsentation (27)
- Forschungsdatensatz (3)
- Forschungsbericht (2)
- Buchkapitel (1)
- Beitrag zu einem Tagungsband (1)
- Preprint (1)
Sprache
- Englisch (156)
- Deutsch (40)
- Mehrsprachig (1)
Schlagworte
- Synchrotron (33)
- BAMline (30)
- Mikroplastik (29)
- TED-GC/MS (25)
- Microplastic (18)
- Microplastics (18)
- XRF (18)
- Mechanochemistry (10)
- TED-GC-MS (9)
- XANES (9)
- MALDI-TOF MS (8)
- Gold (7)
- Machine learning (7)
- Nanoparticle (6)
- Reference material (6)
- Analytik (5)
- Polymer 3R (5)
- XRD (5)
- Analysis (4)
- Automation (4)
- Bayesian Statistics (4)
- In situ (4)
- Pollen (4)
- Polylactide (4)
- Reference materials (4)
- Single cell analysis (4)
- TXRF (4)
- Water (4)
- Archaea (3)
- Coded Aperture (3)
- DNA (3)
- Dosimetry (3)
- Gaussian process (3)
- Machine Learning (3)
- Microbiologically influenced corrosion (3)
- Mikroplastik-Analytik (3)
- Nanoparticles separation capillary electrophoresis asymmetrcial flow field flow fractionation (3)
- Neural network (3)
- Probennahme (3)
- Referenzmaterialien (3)
- SAXS (3)
- Sampling (3)
- Sampling techniques (3)
- Standardisation (3)
- Tire wear (3)
- Trinkwasser (3)
- Affinity Chromatography (2)
- Aktivkohle (2)
- Amperometry (2)
- Analytic (2)
- Artificial Inelligence (2)
- Artificial intelligence (2)
- Asymmetrical flow field flow fractionation (AF4) (2)
- Batteries (2)
- Bayesian Optimization (2)
- Bioimaging (2)
- CXC (2)
- Capillary electrophoresis (2)
- Capillary electrophoresis (CE) (2)
- Certification (2)
- Crystalinity (2)
- D2XRF (2)
- EXAFS (2)
- FPLC (2)
- HPLC (2)
- Harmonisation (2)
- Homogeneity (2)
- ILC (2)
- Immunoassay (2)
- Internal Standard (2)
- Ionization (2)
- Lanthanide (2)
- MALDI TOF MS (2)
- Nanomaterial (2)
- Polymere (2)
- Polymers (2)
- Probenahme (2)
- Quality testing (2)
- Referenzmaterial (2)
- Risk assessment (2)
- SC-ICP-ToF-MS (2)
- Sc-ICP-ToF-MS (2)
- Soil (2)
- Spectroscopy (2)
- Stability (2)
- Standarisierung (2)
- Synthesis (2)
- Thermogravimetrie (2)
- Umwelt (2)
- Wasseraufbereitung (2)
- X-ray fluorescence (2)
- XAFS (2)
- A4F (1)
- AG nanoparticle (1)
- AU nanoparticle (1)
- Absorption spectrometry (1)
- Acidic oxygen evolution reaction (1)
- Acoustic levitation (1)
- Acute myocardial infarction (1)
- Additive (1)
- Additive Manufacturing (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Amyloid (1)
- Analyse (1)
- Analytical Sciences (1)
- Analytical standards (1)
- Antibodies (1)
- Antibody Purification (1)
- Antikensammlung Berlin (1)
- Application properties (1)
- Archaeometry (1)
- Archäometrie (1)
- Artificial Intelligence (1)
- Aspergillus (1)
- Atomic layer deposition (1)
- Aufbereitung (1)
- Automated Purification (1)
- Barium (1)
- Battery (1)
- Bayes (1)
- Bbeverages (1)
- Beamline (1)
- Bernstorf (1)
- Biological & biomedical applications (1)
- Biomarker (1)
- Biosensor (1)
- Biosynthesis (1)
- Bismuth (1)
- Bisphenol A (1)
- Bone matrix (1)
- Borosilicate Glass (1)
- Böden (1)
- CCQM key comparison (1)
- Calcium monofluoride (1)
- Carboxyl group (1)
- Cardiac troponin (1)
- Cascade filtration (1)
- Catalysts (1)
- Cathode material (1)
- Causes leading to scientific misconduct (1)
- Channel access (1)
- Chemical composition (1)
- Chemical transformation (1)
- Chemiluminescence (1)
- Citizen Science (1)
- Classification (1)
- Cobalt deposition (1)
- Cocoa (1)
- Cocrystal (1)
- Color X-ray Camera (1)
- Column holder (1)
- Comparative test (1)
- Compost (1)
- Concentration step (1)
- Conjugate (1)
- Construction (1)
- Coordination polymers (1)
- Core-shell nanoparticles (1)
- Core/shell nanoparticle (1)
- Corrosion (1)
- Coupling reactions (1)
- Crystallization (1)
- Cyclic voltammetry (1)
- Cyclization (1)
- Cycloparaphenylenes (1)
- Cylic Voltammetry (1)
- DNA strand break (1)
- Data conversion (1)
- Data manipulation (1)
- Debye-Waller parameter (1)
- Deep work (1)
- Degradation (1)
- Density separation (1)
- Depth profile (1)
- Desorption (1)
- Detektion (1)
- Detektion von Mikroplastik (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Digital laboratory (1)
- Digitalization (1)
- Dispersive-XAS (1)
- Dose (1)
- Down Stream Processing (1)
- EPICS (1)
- Ectoine (1)
- Ectoine radiation protection (1)
- Egypt (1)
- Electrocatalysis (1)
- Electrochemistry (1)
- Electrohpresis (1)
- Elektronenmikroskopie (1)
- Emergency (1)
- Endocrine disruptor (1)
- Energy input (1)
- Energy storage (1)
- Environmental analysis (1)
- Environmental impacts (1)
- Epoxy (1)
- Extended X-ray absorption fine structure (1)
- FTIR (1)
- Farbenlehre (1)
- Fenton (1)
- Filter crucible (1)
- Filtration (1)
- Flow injection immunoassay (1)
- Fluorescence (1)
- Fluorine (1)
- Folic acid (1)
- Food safety (1)
- Fraktionierte Filtration (1)
- Framework (1)
- Fundamentals (1)
- Fusarium (1)
- GUI (1)
- Gaussian Process (1)
- General Chemistry (1)
- General Materials Science (1)
- Gilding (1)
- Glass (1)
- Glass Support (1)
- Goethe (1)
- Graphite furnace (1)
- Greek curse tablets (1)
- H/D-Austausch (1)
- H/D-Exchange (1)
- H2020 (1)
- HDF5 (1)
- HERFD-XAS (1)
- HR-CS-MAS (1)
- Hamonisierung (1)
- Handheld (1)
- Harmonisierung (1)
- Hazardous substances (1)
- Heart attack (1)
- Heavy metals (1)
- Hierarchical cluster analysis (1)
- High repetition-rate (1)
- High-Speed Separations (1)
- High-entropy alloy (1)
- High-resolution synchrotron XRF (1)
- Histology (1)
- Holistic science (1)
- Host–guest systems (1)
- Human Plasma (1)
- Hydrogen (1)
- ILC on detection methods (1)
- IgG determination (1)
- Image manipulation (1)
- Immuno assay (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Implant material (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In situ studies (1)
- Inlet ionization (1)
- Instrument control (1)
- Instrumentation (1)
- Instrumentation utilization (1)
- Inter-laboratory comparison (1)
- Interner Standard (1)
- Ion mobility (1)
- Ionizing radiation (1)
- Iridium oxide (1)
- Klassifizierung (1)
- LA-ICP-MS (1)
- Laboratory automation (1)
- Laboratory management (1)
- Lacunary Keggin ion (1)
- Lead ions (1)
- Lead isotopes (1)
- Levitation (1)
- Li-ion battery (1)
- Luminol (1)
- MALDI (1)
- MALDI Imaging (1)
- MALDI Imaging MS (1)
- MALDI-TOF Massenspektrometrie (1)
- MALDI-ToF MS (1)
- MAS NMR spectroscopy (1)
- MCC (1)
- MDG ICP-ToF-MS (1)
- MOF (1)
- MOUSE (1)
- Machining (1)
- Macrocycles (1)
- Macrophagen (1)
- Magnetic nanocatalyst (1)
- Maia detector (1)
- Mass contents (1)
- Mass spectrometry (1)
- Massenspektrometrie (1)
- Material characterization (1)
- Matrices (1)
- Measurement data conversion (1)
- Mechanism (1)
- Mechanochemical synthesis (1)
- Metal nanoparticles (1)
- Metal-tag (1)
- Metformin (1)
- Methodenentwicklung Böden (1)
- Methodology (1)
- Metrics (1)
- Microdosimetry (1)
- Microdroplet generator (1)
- Microfluidic system (1)
- Microplastic analysis (1)
- Microplastic mass (1)
- Microplastic particles (1)
- Microplastic pathways (1)
- Microplastics analytic (1)
- Microplastics detection (1)
- Microplastics sampling (1)
- Microplastics standardisation (1)
- Mikroplastik Böden (1)
- Mikroplastik Massegehalt (1)
- Mikroplastik in Luft (1)
- Mikroplastikreferenzmaterial (1)
- Modelling (1)
- Molecular recognition (1)
- Molecule (1)
- Monitoring (1)
- Monoclonal Antibodies (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Monolithic column (1)
- Motor controller (1)
- Multimodal (1)
- Multivariate Analyse (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- Mycotoxin (1)
- Mycotoxins (1)
- NIR spectroscopy (1)
- NMR (1)
- NXsas (1)
- Nano (1)
- Nanocarrier (1)
- Nanocrystal (1)
- Nanomaterials (1)
- Nanoparticles (1)
- Nanoparticles with same nominal diameter (1)
- Nanoparticles with same nominal diameter; surface coating; two-dimensional off-line coupling (1)
- Nanoplastic (1)
- Nanoplastics (1)
- Natural language processing (1)
- NeXus (1)
- Near edge X-ray absorption fine structure spectroscopy (1)
- Nebra (1)
- Neural Network (1)
- Neural networks (1)
- Nondestructive testing techniques (1)
- OECD (1)
- Ochratoxin A (1)
- Online biosensor (1)
- Open Science (1)
- Optimierung (1)
- Outreach (1)
- P-aminothiophenol (1)
- PET (1)
- PXRD (1)
- Paper mills (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle size distribution (1)
- Pb isotopes (1)
- Peroxidase (1)
- Pharmacy (1)
- Phosphonate esters (1)
- Phosphonates (1)
- Photocatalysis (1)
- Photodegradation (1)
- Photooxidation (1)
- Plastic bottles (1)
- Pollen grains (1)
- Pollenkörner (1)
- Polycapillaries (1)
- Polyclonal Antibodies (1)
- Polyethyleneglycol (1)
- Polymer blends (1)
- Polymere Eigenschaften (1)
- Polymorph (1)
- Polymorphs (1)
- Polyoxometalates (1)
- Polyurethanes (1)
- Pomodore (1)
- Poster presentation (1)
- Principal component analysis (1)
- Principal component analysis (PCA) (1)
- Prisma (1)
- Probenpräparation (1)
- Procedure (1)
- Protein A (1)
- Protein Purification (1)
- Purification (1)
- Purity assessment (1)
- Python (1)
- Quality (1)
- Qualitätssicherung (1)
- Quantum dot (1)
- Quick-XAS (1)
- RUSEKU (1)
- RXES (1)
- Radiation (1)
- Radiation damage (1)
- Raman (1)
- Refractory alloys (1)
- Regeneration (1)
- Reifenabrieb (1)
- Release kinetics (1)
- Reliabiilty (1)
- Renewable Energy (1)
- Rhizopus (1)
- Ringversuch (1)
- Ringversuche (1)
- River (1)
- Robustness (1)
- Röntgenfluoreszenz (1)
- Salt (1)
- Sample preparation (1)
- Sata corrections (1)
- Scattering (1)
- Scientific misconduct (1)
- Sedimentation box (SB) (1)
- Sedimentationskasten (1)
- Sedimenttaionskasten (1)
- Self-assembly (1)
- Sensing (1)
- Separation (1)
- Sers (1)
- Si wafer filter (1)
- Silver nanoparticles (1)
- Sintered Material (1)
- Size (1)
- Size exclusion chromatography (1)
- Slags (1)
- Small-angle scattering (1)
- Soft-templated mesoporous films (1)
- Software (1)
- Solid support (1)
- Solvent-free (1)
- Sonochemical synthesis (1)
- Spinel (1)
- Sportböden (1)
- Supramolecular chemistry (1)
- Surface chemistry (1)
- Surface coating (1)
- Suspended particulate matter (SPM) (1)
- Sustainability and the Environment (1)
- TGA-FTIR (1)
- TGA-MS (1)
- TMB (1)
- TXRF-XAS (1)
- Tattoo inks (1)
- Temperature (1)
- Tesserae (1)
- Textile fibres (1)
- The MOUSE (1)
- Therapeutic Antibodies (1)
- Thermal analysis (1)
- Thermal degradation (1)
- Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS), monitoring (1)
- Thermal extraction-desorption gas chromatography mass spectrometry (1)
- Thermo-desorption (1)
- Thermoanalyse (1)
- Thermoanalysis (1)
- Thermoanalytic (1)
- Thermoanalytical methods (1)
- Thermoanalytics (1)
- Thermoanalytik (1)
- Tire Wear (1)
- Tire particles (1)
- Tools to combat scientific misconduct (1)
- Toxic metals (1)
- Traceability (1)
- Transesterification (1)
- Two-dimensional off-line coupling (1)
- Ultrasound (1)
- Underwater LIBS (1)
- Urban (1)
- VAMAS (1)
- VRF (1)
- Vacuum ionization (1)
- Validation (1)
- Vanadium redox flow battery (1)
- WAXS (1)
- Wastewater (1)
- Water samples (1)
- Welding (1)
- X-Ray Fluorescence (1)
- X-ray absorption spectroscopy (1)
- X-ray and electron diffraction (1)
- X-ray fluorescence spectroscopy (1)
- X-ray photoelectron spectroscopy (1)
- X-ray scattering (1)
- X-ray spectroscopy (1)
- XAS (1)
- Xerogel (1)
- Zearalenone (1)
- Zinc analysis (1)
- Zirconium (1)
- electrocatalysis (1)
- microplastics, sampling, sampling techniques, water (1)
- nanostructured (1)
- µJ-DPSS laser (1)
- Ägyptisches Museum Berlin (1)
Organisationseinheit der BAM
- 6 Materialchemie (197) (entfernen)
Paper des Monats
- ja (1)
The electrocatalytic conversion of water into molecular hydrogen and oxygen under the utilization of excess renewable energies, such as wind power, photovoltaics and hydroelectric power is one possible pathway to establish a sustainable hydrogen economy. The obtained hydrogen is either stored and used in a fuel cell or consumed on-site in industrial applications.
Water electrolysis systems (WES) are based on two half cell reactions, such as oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) which both proceed simultaneously. The OER suffers from slow reaction kinetics and thus limits the overall performance.
The most promising compounds in acidic electrolysis are IrO2 and RuO2. Due to their rare abundance and extremely high price a wide use of acidic WES was prevented. Lowering the catalysts noble metal content by mixing iridium with titanium reduces the production costs.
Thin films are produced by dip coating a solution of metal oxide precursors alongside with a polymer template dissolved in ethanol. The obtained samples are subsequently calcined to the remove the template and adjust crystallinity. Finally, an additional iridium deposition step was performed on the outer surface plane area.
Understanding the influence of structural and morphological aspects on the OER-activity is beneficial to further optimize WES. The current presentation will thus give detailed insights to structural aspects obtained by Raman spectroscopy, small- and wide-angle X-ray scattering which are then combined with electrochemical parameters to deduce structure-activity relationships.
Cyclic poly(L-lactide)s were prepared by ring-opening polymerization combined with simultaneous polycondensation (ROPPOC) in bulk at 160 ° with dibutyltin bis(4-cyanophenoxide) as catalyst. It is demonstrated by MALDI TOF mass spectrometry and 1H NMR end group analyses that cycles are formed by endto-end cyclization in addition to “back-biting” transesterification. Formation of high molar mass cyclic poly L-lactide)s by means of several more reactive ROPPOC catalysts presented previously and in new experiments is discussed. These experimental results, together with theoretical arguments, prove that part of the Jacobson–Stockmayer theory is wrong. The critical monomer concentration, above which end-toend cyclization is seemingly impossible, does not exist and reversible like irreversible polycondensations can theoretically proceed up to 100% conversion, so that finally all reaction products will necessarily adopt a cyclic architecture.
The successful off-line coupling of asymmetrical flow field flow fractionation (AF4) and capillary electrophoresis (CE) for Separation of nanoparticles (NPs) with different surface coatings was shown.
Two mixtures of polystyrene nanoparticles (PS-NPs) with comparable core sizes (20 nm and 50 nm) but different coatings (no coating/carboxyl-coated) were studied. Separation in either method resulted in non-baseline resolved or non-separated peaks. In contrast, two-dimensional off-line coupling of AF4 and CE resulted in clearly separated regions in their 2 D plots and can obviouly improve separation resolution.
The analysis of pollen chemical composition is important to many fields, including agriculture, plant physiology, ecology, allergology, and climate studies. Here, the potential of a combination of different spectroscopic and spectrometric methods regarding the characterization of small biochemical differences between pollen samples was evaluated using multivariate statistical approaches. Pollen samples, collected from three populations of the grass Poa alpina, were analyzed using Fourier-transform infrared (FTIR) spectroscopy, Raman spectroscopy, surface enhanced Raman scattering (SERS), and matrix assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS). The variation in the sample set can be described in a hierarchical framework comprising three populations of the same grass species and four different growth conditions of the parent plants for each of the populations. Therefore, the data set can work here as a model system to evaluate the classification and characterization ability of the different spectroscopic and spectrometric methods. ANOVA Simultaneous Component Analysis (ASCA) was applied to achieve a separation of different sources of variance in the complex sample set. Since the chosen methods and sample preparations probe different parts and/or molecular constituents of the pollen grains, complementary information about the chemical composition of the pollen can be obtained. By using consensus principal component analysis (CPCA), data from the different methods are linked together. This enables an investigation of the underlying global information, since complementary chemical data are combined. The molecular information from four spectroscopies was combined with phenotypical information gathered from the parent plants, thereby helping to potentially link pollen chemistry to other biotic and abiotic parameters.
Perhaps due in no small part to its historical mystique, mechanochemistry has been shrowded in relative obscurity for quite some time. The successes of mechanochemistry in organic synthesis have often been curtailed by a fundamentally limited mechanistic understanding. Lately, however, the community has made great strides towards understanding the fundamentals, as well as large steps forward regarding industrially significant scale-up via twin-screw extrusion. A variety of recent work has traded in some of mechanochemistry’s mystique for simple, straight-forward chemical guidelines.
We present the optical sensing of phthalate Esters (PAEs), a group of endocrine-disrupting chemicals. The sensing takes place as changes in the fluorescence emission intensity of aminopyrene covalently bound to the organic ligands of the metal−organic framework compound ZIF-8. In the presence of PAEs, a quenching of the fluorescence emission is observed. We evaluated strategies to engineer colloidal size distribution of the sensing particles to optimize the sensory response to PAEs. A thorough characterization of the modified ZIF-8 nanoparticles included powder X-ray diffractometry, transmission electron microscopy, high-performance liquid chromatography, and photophysical characterization. The presented capability of the fluorophore-functionalized ZIF-8 to sense PAEs complements established methods such as chromatography-based procedures, which cannot be used on-site and paves the way for future developments such as hand-held quick sensing devices.
Besides conventional scanning X-ray fluorescence imaging at synchrotron sources, full-field X-ray fluorescence (FF-XRF) imaging techniques that do not implicitly require spatial scanning of the sample have become available. FF-XRF has become achievable thanks to the development of a new type of energy dispersive CCD-based 2D detector, also referred to as a 'color X-ray camera (CXC)' or 'SLcam'. We report on different imaging schemes for biological samples using FF-XRF imaging: (a) 2D 'zoom' imaging with pinhole optics using the 'camera obscura' principle; (b) 2D 'fixed magnification' imaging using magnifying polycapillary optics; and (c) 3D-FF-XRF imaging using an X-ray sheet beam or computed tomography (CT). The different FF-XRF imaging modes are illustrated using the crustacean Daphnia magna, a model organism for investigating the effects of metals on organism/ecosystem health, and foraminifera, a class of amoeboid protist. Detailed analytical characterization of the set-up is performed through analyzing various reference materials in order to determine limits of detection (LODs) and sensitivities. Experiments were performed using the BAMline at the BESSY synchrotron (Berlin, Germany) and using the P06 Hard X-ray Microprobe at the PETRAIII synchrotron (Hamburg, Germany).
The elemental analysis of seawater is often critical to the understanding of marine chemistry, marine geochemistry, and the deep-sea ecosystems. Laser-induced breakdown spectroscopy (LIBS) with the advantage of rapid multi-elements detection, has a great potential for in-situ elemental analysis of seawater. In practice, it is crucial to create a compact, low cost and power saving instrument for the long-term deep-sea observation. A recently appeared diode-pumped solid-state (DPSS) laser seems to be a promising candidate as it is both compact and robust. Additionally, its high repetition rate up to hundreds of kHz can provide a considerable throughput for LIBS analysis. However, the DPSS lasers operate at moderate pulse energies, usually less than one mJ, which cannot sustain stable breakdowns in bulk water. To ensure stable laser-induced plasmas underwater with such a μJ-DPSS laser, we introduced an ultrasound source to assist the breakdown process. The phase interface and mass flow generated by the near-field ultrasound can greatly reduce the breakdown threshold and enhance element-specific emissions. Meanwhile, the high repetition-rate pulses can also improve the breakdown probability and generate unique emission lines originated from the water molecule. We further demonstrate that the high repetition-rate DPSS laser combined with the Echelle spectrometer can provide effective quantitative analysis for metal elements in bulk water.
Matrix‐assisted ionization (MAI) mass spectrometry does not require voltages, a laser beam, or added heat to initiate ionization, but it is strongly dependent on the choice of matrix and the vacuum conditions. High charge state distributions of nonvolatile analyte ions produced by MAI suggest that the ionization mechanism may be similar to that of electrospray ionization (ESI), but different from matrix‐assisted laser desorption/ionization (MALDI). While significant information is available for MAI using mass spectrometers operating at atmospheric and intermediate pressure, little is known about the mechanism at high vacuum.
Eleven MAI matrices were studied on a high‐vacuum time‐of‐flight (TOF) mass spectrometer using a 266 nm pulsed laser beam under otherwise typical MALDI conditions. Detailed comparisons with the commonly used MALDI matrices and theoretical prediction were made for 3‐nitrobenzonitrile (3‐NBN), which is the only MAI matrix that works well in high vacuum when irradiated with a laser.
Screening of MAI matrices with good absorption at 266 nm but with various degrees of volatility and laser energies suggests that volatility and absorption at the laser wavelength may be necessary, but not sufficient, criteria to explain the formation of multiply charged analyte ions. 3‐NBN produces intact, highly charged ions of nonvolatile analytes in high‐vacuum TOF with the use of a laser, demonstrating that ESI‐like ions can be produced in high vacuum. Theoretical calculations and mass spectra suggest that thermally induced proton transfer, which is the major ionization mechanism in MALDI, is not important with the 3‐NBN matrix at 266 nm laser wavelength. 3‐NBN:analyte crystal morphology is, however, important in ion generation in high vacuum.
The 3‐NBN MAI matrix produces intact, highly charged ions of nonvolatile compounds in high‐vacuum TOF mass spectrometers with the aid of ablation and/or heating by laser irradiation, and shows a different ionization mechanism from that of typical MALDI matrices.