Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (18) (entfernen)
Schlagworte
- CONSENS (2)
- Prozessanalytik (2)
- UFP (2)
- Umweltsimulation (2)
- Africa (1)
- Analytics (1)
- Analytik (1)
- Betriebspunktoptimierung (1)
- Bewitterung (1)
- Bias (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (8)
- 4 Material und Umwelt (6)
- 1.4 Prozessanalytik (5)
- 4.2 Material-Mikrobiom Wechselwirkungen (4)
- 8 Zerstörungsfreie Prüfung (3)
- 1.1 Anorganische Spurenanalytik (2)
- 1.8 Umweltanalytik (2)
- 4.5 Kunst- und Kulturgutanalyse (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 1.5 Proteinanalytik (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.2 Gefahrguttanks und Unfallmechanik (1)
- 4.0 Abteilungsleitung und andere (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 4.3 Schadstofftransfer und Umwelttechnologien (1)
- 6 Materialchemie (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
- 7 Bauwerkssicherheit (1)
- 7.0 Abteilungsleitung und andere (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
Ionische Flüssigkeiten als neuartige Sensorbeschichtung für coulometrische Spurenfeuchtesensoren
(2018)
Die Arbeit präsentiert erste Messungen mit coulometrischen Sensoren, die mit einer ionischen Flüssigkeit beschichtet sind. Diese Sensoren werden in der Industrie verwendet, um die Spurenfeuchte in unterschiedlichen Gasen zu messen. Normalerweise erfolgt eine Beschichtung der Sensoren mit Phosphorpentoxid und dessen Hydrolyseprodukte. In dieser Arbeit wurde stattdessen eine hygroskopische ionische Flüssigkeit benutzt. Die generierte Gasfeuchte für die Untersuchungen betrug bezogen auf die Frostpunkttemperatur -80 °C bis -30 °C, was gleichbedeutend mit einem Wasserdampf-Stoffmengenanteil von 0,5 μmol·mol-1 bis 376 μmol·mol-1 ist. Zusätzlich zu der Messung mit coulometrischen Sensoren erfolgte eine Referenzmessung der Gasfeuchte mittels eines Taupunkthygrometers. Erste Ergebnisse haben gezeigt, dass es möglich ist mit dieser Art der Beschichtung unterschiedliche Gasfeuchten zu messen. Aber es ergaben sich trotz gleicher Feuchte unterschiedliche Signalintensitäten bei den benutzen Sensoren und es zeigte sich eine Drift des Sensorsignales.
Nach 1850 wurde zur weiteren Herabsetzung der Einbrenntemperatur von Glasmalfarben Borax (Na2B4O7 · 10 H2O) zugesetzt. Das Verhältnis war nun 1 Teil SiO2, 3 Teile PbO und 0,5 Teile Borax. Der analytische Nachweis von Bor in eingebrannten Malschichten war bisher jedoch nicht möglich.Daher wurden in Laborversuchen Glasmalfarben mit unterschiedlichem Gehalt an Borax auf Modellgläser aufgetragen, eingebrannt und anschließend unter simulierten Umweltbedingungen zeitraffend im Klimaschrank bewittert.
Mit Hilfe von elektronenmikroskopischen Untersuchungen können Malschichten charakterisiert werden und somit Hinweise auf mögliche Schadensursachen liefern. Erste Versuche zum Nachweis von Bor erfolgten mit Hilfe von LIBS-Messungen (Laser Induced Breakdown Spectroscopy) an im Labor hergestellten Glasmalfarben mit unterschiedlichem Boraxgehalt.
Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which require excessive calibration effort. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environ¬ments for advanced process monitoring and control, as demonstrated within the European Union’s Horizon 2020 project CONSENS.
We present a range of approaches for the automated spectra analysis moving from conventional multivariate statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants or derivatives and robust automation schemes.
Produzieren Sie schon oder kalibrieren Sie noch? – Online-NMR-Spektrometer als Smarte Feldgeräte
(2018)
Der Vortrag zeigt allgemeine Anforderungen an "smarte Feldgeräte" und deren Entwicklung in den vergangenen Jahren. Am Beispiel eines smarten Online-NMR-Sensors, der in einem EU-Projekt von der BAM entwickelt wurde, wird die Umsetzung der Anforderung aufgezeigt. Schließlich werden weitere Technologieanforderungen und Lösungsansätze vorgestellt.
Bulk enstatite chondrites (EC) and their achondritic counterpart, the aubrites, have the lightest measured Si isotope composition of all rocks in the solar system. Some authors proposed that the enrichment of 28Si in EC metal by equilibrium or kinetic isotope fractionation processes in the solar nebula may have led to the negative δ30/28Si of bulk EC. Because EC are also depleted in refractory elements, loss of a heavy Si component with refractory elements might be an alternative explanation. To further constrain their genesis, we analysed for the first time in situ Si-isotope ratios simultaneously with major- and trace element abundances in silicate and metal phases of Sahara 97072 (EH3) and Indarch (EH4).
Im Zuge der Digitalisierung der Prozessindustrie werden zunehmend modellbasiere Echtzeitoptimierungsverfahren eingesetzt, sog. „Advanced Process Control“. Mithilfe der sogenannten Modifier-Adaptation ist eine iterative Betriebspunktoptimierung auch mit ungenauen Modellen möglich, sofern zuverlässige Prozessdaten zur Verfügung stehen. Am Beispiel eines smarten Online-NMR-Sensors, der in einem EU-Projekt von der BAM entwickelt wurde, konnte das Konzept in einer modularen Produktionsanlage zur Herstellung eines pharmazeutischen Wirkstoffs erfolgreich getestet werden.
Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umwelt-beständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden.