Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Vortrag (395) (entfernen)
Sprache
- Englisch (293)
- Deutsch (99)
- Mehrsprachig (2)
- Französisch (1)
Referierte Publikation
- nein (395)
Schlagworte
- Mikroplastik (22)
- Synchrotron (19)
- Process Analytical Technology (18)
- BAMline (16)
- XRF (16)
- Online NMR Spectroscopy (15)
- TED-GC/MS (14)
- HR-CS-GFMAS (13)
- PFAS (13)
- Prozessanalytik (13)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (270)
- 1.1 Anorganische Spurenanalytik (99)
- 6 Materialchemie (92)
- 1.4 Prozessanalytik (78)
- 1.6 Anorganische Referenzmaterialien (56)
- 6.6 Physik und chemische Analytik der Polymere (46)
- 6.3 Strukturanalytik (39)
- 4 Material und Umwelt (34)
- 1.8 Umweltanalytik (28)
- 1.7 Organische Spuren- und Lebensmittelanalytik (23)
This talk presents the EU funded project PlasticTrace. It shows the challenges in micro- and nanoplastic reference materials and gives some solutions regarding spectroscipc methods such as Raman or IR microscopy to determine the particle numbers. Materials are prepared by cryo milling to get some powder that is later pressed into tablets. The polymer type used is PET, because that is highly important for drinking water directive of EU commission.
Motivation: A precise diagnosis of atherosclerosis is of clinical importance, since cardiovascular disease remain one of the leading causes of death worldwide.
Goal(s): The goal of this study was to evaluate the feasibility of characterizing a disintegrin and metalloproteinase with thrombospondin motifs (ADAMTS4) using molecular magnetic resonance imaging in a preclnical model of atherosclerosis.
Approach: Molecular magnetic resonance imaging using a novel probe targeted against ADAMTS4 was used in a high-fat murine model.
Results: It was possible to image atherosclerotic lesions in a mouse model using an ADAMTS4- specific probe for magnetic resonance imaging.
Impact: Using molecular MRI targeting ADAMTS4 is a promising method for characterization of plaque composition and could possibly impact plaque vulnerability assessment in the diagnosis and treatment of atherosclerosis in patients.
Colloids provide manifold opportunities for targeted product design due to their tunable properties with respect to size, shape, composition, surface, and spectral characteristics. However, the determination of structure-property relationships is quite challenging as most particulate samples exhibit polydispersity of their disperse properties. Analytical ultracentrifugation (AUC) is a fractionating technique and highly accurate method for the multidimensional analysis of nanoparticles as it permits the differentiation of spectral information linked to hydro- and thermodynamic properties of the particles.
So far, characterization capabilities for fluorescent nanoparticles by AUC were limited, as the formerly commercially available fluorescence detector could not provide any spectral information. Using a multiwavelength emission detector developed in our group, it is possible to extract spectra of fluorescent particles and biomolecules alongside their sedimentation and diffusion coefficients within a single centrifugation experiment.
In our contribution, we will highlight that even narrowly distributed core/shell CdSe/CdS quantum dots still show size- and structure-dependent shifts of their fluorescence spectra, which can be resolved with our AUC system in an ensemble measurement. Thereby, we can link spectral changes of only a few nanometers to particle sizes retrieved with Angstrom size resolution. Single-particle measurements not only supported the results obtained with the AUC system but also provided deeper insights into the photophysical processes of individual QDs, clearly demonstrating the complementary nature of the techniques used. With our novel multiwavelength emission detector and the established extinction-based detector for AUC, a comprehensive platform for the holistic characterization of fluorescent colloids is now available.
Inorganic and organic functional nanomaterials (NM) of different size, shape, chemical composition, and surface chemistry are relevant for many key technologies of the 21st century. Decisive for most applications of NM are their specific surface properties, which are largely controlled by the chemical nature and number of ligands and functional groups (FG on the NM surface. The surface chemistry can strongly affect the physicochemical properties of NM, their charge, hydrophilicity/hydrophobicity, reactivity, stability, and processability and thereby their impact on the environment and biological species as well as their possible risk for human health. Thus, reliable, validated, and eventually standardized analytical methods for the characterization of NM surface chemistry, i.e., the chemical identification, quantification, and accessibility of FG and surface ligands 1,2] flanked by interlaboratory comparisons, control samples, and reference materials, 2 ,3 are of considerable importance for process and quality control of NM production and function. This is also important for the safe use of NM the design of novel NM, and sustainable concepts for NM fabrication. Here, we provide an overview of analytical methods for FG analysis and quantification and highlight method and material related challenges for selected NM. Analytical techniques address ed include electrochemical titration methods, optical assays, nuclear magnetic resonance (NMR) and vibrational (IR) spectroscopy, and X ray based and thermal analysis methods. Criteria for method classification and evaluation include the need for a signal generating label, provision of either the total or derivatizable number of FG, and suitability for process and production control.
A journey in science from a graduate student in physical chemistry to head of division biophotonics
(2024)
I will provide a personal overview of the most important steps of my career in science, a journey from a graduate student in physical chemistry in an environment dominated by male-scientists over a postdoc with a female professor in the US to the leader of a research group, head of division Biophotonics at BAM. This will include my choices of research topics, how I learnt to write well cited publications, even on topics such as reference materials and quality assurance,1-4 and eventually started to give lectures at Free University Berlin granting me the right to act as first supervisor of undergraduate and graduate students.
Optical measurements of scattering luminescent materials dispersed in liquid and solid matrices and luminescent powders play an important role in fundamental research and industry. Typical examples are luminescent nano- and microparticles and phosphors of different composition in different matrices or incorporated into ceramics with applications in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. The key parameter for the performance of these materials is the photoluminescence quantum yield QY, i.e., the number of emitted photons per number of absorbed photons. QY of transparent luminophore solutions can be determined relatively to a fluorescence quantum yield standard of known QY. Such standards are meanwhile available as certified reference materials.[1] The determination of QY of scattering liquid and solid samples like dispersions of luminescent nanoparticles, solid phosphors, and optoceramics requires, however, absolute measurements with an integrating sphere setup. Although the importance of reliable absolute QY measurements has been recognized, no interlaboratory comparisons (ILCs) on measurement uncertainties and the identification of typical sources of uncertainty have been yet reported. Also, no scattering reference materials with known QY are available.
We present here the results of a first ILC of 3 laboratories from academia and industry performed to identify and quantify sources of uncertainty of absolute QY measurements of scattering samples. Thereby, two types of commercial stand-alone integrating sphere setups with different illumination and detection geometries were utilized for measuring QY of transparent and scattering dye solutions and solid phosphors. As representative and industrially relevant solid and scattering samples, YAG:Ce optoceramics of varying surface roughness were chosen, applied, e.g., as converter materials for blue light emitting diodes. Special emphasis was dedicated to the influence of the measurement geometry, the optical properties of the blank, utilized to determine the number of photons of the incident excitation light absorbed by the sample, and the sample-specific surface roughness. While matching QY values could be obtained for transparent dye solutions and scattering dispersions, here using a blank with scattering properties closely matching those of the sample, QY measurements of optoceramic samples with different blanks revealed substantial differences, with the blank's optical
properties accounting for measurement uncertainties of more than 20 %. Based upon the ILC results, we recommend non-absorbing blank materials with a high reflectivity (>95 %) such as a 2 mm-thick PTFE target placed on the sample holder which reveals a near-Lambertian light scattering behavior, yielding a homogeneous light distribution within the integrating sphere.
Characterization and quantification of functional groups and coatings on nanoobjects an overview
(2024)
Characterization of Nanoparticles – Questions to Ask, Functional Nanoparticles (NPs) – Organic, Inorganic, and Hybrid Nanoparticles Nanomaterial Characterization Standardization – Addressing Remaining Gaps Surface FGs Particle Surface Chemistry - Why is it Important? Particle Surface Chemistry - A Key Driver for Performance, Applications, and Safety Aspects Method Development for Quantifying FGs and Ligands on Particle Surfaces FG Quantification – Method Choice & Criteria Relevant for Data Interpretation Quantifying the Amount of Total and Accessible FGs on Aminated Silica Nanoparticles (SiO2-NH2) Comparing the Total and Accessible –NH2 Content on Aminated Silica NPs of Different Size Characterization of Nanoparticles Standardization Standardized Measurements of Surface FGs on Nanoparticles EMP Project SMURFnano EMP Project SMURFnano Work Packages & Goals Certified Reference Materials from BAM
To reduce carbon dioxide emissions, energy carries such as hydrogen consider to be a solution. Consumption of hydrogen as a fuel meets several restrictions such as its low volumetric energy density in gas phase. To tackle this problem, storage as well as transportation in liquid phase is recommended. To be able to handle this component in liquid phase, an efficient thermal insulation e.g., MLI insulation is required. Some studies have been revealed vulnerability of this type of insulation against high heat flux, for instance a fire accident. Some investigations have been depicted the importance of consideration of the MLI thermal degradation in terms of its reflective layer. However, limited number of studies have been focused on the thermal degradation of spacer material and its effect on the overall heat flux.
In this study, through systematic experimental measurements, the effect of thermal loads on glass fleece, glass paper as well as polyester spacers are investigated. The results are reported in various temperature and heat flux profiles. Interpreting the temperature profiles revealed as the number of spacers in the medium increases, the peak temperature detectable by the temperature sensor on the measurement plate decreases. Moreover, the contribution of each individual spacer in all cases regarding the experimental temperature range is assessed to be around 8%. This value may increase to around 50% for glass paper and polyester spacers, and to around 25% for glass fleece spacers as the number of spacer layers increases up to six layers.
To utilize the outcomes of the experiment later and integrate the results into numerical and CFD simulations, a model is proposed for the mentioned experimental temperature range up to 300°C to predict a heat flux attenuation factor. The model proposes a fitting factor that can reproduce the least square fitted line to the experimental data.
Ensuring the purity of air and water is essential for the overall well-being of life on earth and the sustainability of the planet's diverse ecosystems. To achieve the goal of zero pollution, as outlined in the 2020 European Green Deal by the European Commission,[1] significant efforts are in progress. A key aspect of this commitment involves advancing more efficient and economically viable methods for treating wastewater. This includes the systematic monitoring of harmful pollutants such as heavy metals, microplastics, pesticides, and pharmaceuticals.
One example is the presence of the anti-inflammatory drug diclofenac in water systems, primarily originating from its use as a gel or lotion for joint pain treatment. Diclofenac contamination in surface waters has been detected at approximately 10 μg L-1 (0.03 μM)[2] which is not solely due to widespread usage but also because of the drug's resistance to microbial degradation. Conventional wastewater treatment plants (WWTPs), which rely on biodegradation, sludge sorption, ozone oxidation, and powdered activated carbon treatment, struggle to efficiently remove diclofenac from wastewater.[3],[4] For instance, to enable WWTPs to efficiently monitor and optimize their processes, it would be advantageous to develop on-site detection and extraction methods for persistent pharmaceutical residues in aqueous samples.
In this work, a sol-gel process was used to prepare Nile blue-doped silica nanoparticles (dSiO2-NPs) with a diameter of ca. 30 nm that were further functionalized to enable reversible-addition-fragmentation chain-transfer (RAFT) polymerization. To achieve fluorescence detection, a fluorescent monomer was used as a probe for diclofenac in ethyl acetate, generating stable complexes through hydrogen bond formation. The diclofenac/fluorescent monomer complexes were imprinted into thin molecularly imprinted polymer (MIP) shells on the surface of the dSiO2-NPs. Thus, the MIP binding behaviour could be easily evaluated by fluorescence titrations to monitor the spectral changes upon addition of the analyte. Doping the core substrate with Nile blue generates effective dual fluorescent signal transduction. This approach does not solely depend on a single fluorescence emission band in response to analyte recognition. Instead, it enables the fluorescent core to function as an internal reference, minimizing analyte-independent factors such as background fluorescence, instrumental fluctuation, and operational parameters.[5] Rebinding studies showed that the MIP particles have excellent selectivity towards the imprinted template and good discrimination against the competitor ibuprofen, with a discrimination factor of 2.5. Additionally, the limit of detection was determined to be 0.6 μM. Thus, with further optimization of the MIP, there is potential for the development of a MIP-based biphasic extract-&-detect fluorescence assay for simple, sensitive and specific sensing of diclofenac in aqueous samples down to the required concentrations of 0.03 μM.
Detektion, Quantifizierung und Entfernung von insbesondere ultrakurzkettigen PFAS in Grundwasser
(2024)
Da PFAS in großem Umfang in einer Vielzahl von Produkten verwendet wurde, sind sie im Grundwasser in der Nähe vieler industrieller und militärischer Anlagen weltweit zu finden. Darüber hinaus führten neue Vorschriften und Beschränkungen für die Verwendung von langkettigen PFAS zu einer vermehrten Produktion kurzkettiger Alternativen. Ultrakurzkettige PFAS (≥C3) können natürliche und anthropogene Barrieren durchdringen und schließlich in Trinkwasserquellen gelangen. Zudem entfernen die meisten gängigen Trinkwasser-aufbereitungsverfahren die ultrakurzkettigen PFAS nicht ausreichend. Im Kooperationsprojekt DEFEAT-PFAS wird daher das Ziel verfolgt, Wissenslücken über Nachweis, Quantifizierung und Entfernung von kurz- (C4-C7) und ultrakurzkettige (C1-C3) PFAS, in kontaminiertem Grundwasser zu schließen. Die israelischen und deutschen Projektpartner entwickeln dafür analytische Methoden and selektive Passivsammler, um das zeitliche Profil von PFAS-Spezies im Grundwasser zu erfassen und überwachen. Darüber hinaus ein zweistufiges Verfahren entwickelt, welches darauf ausgelegt ist, die relativ niedrigen PFAS-Konzentrationen im Grundwasser durch neuartige Membranverfahren, Umkehrosmose im Batchbetrieb mit geschlossenem Kreislauf sowie Verbund-Nanofiltrationsmembranen, zu konzentrieren. Anschließend werden die PFAS angereicherten Konzentrate mittels Koagulation behandelt und das verbleibende PFAS an kohlenstoffhaltigen Nanomaterialien adsorbiert.