Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Posterpräsentation (158) (entfernen)
Referierte Publikation
- nein (158)
Schlagworte
- Process Analytical Technology (12)
- Nanoparticle (10)
- ICP-MS (9)
- Bioimaging (8)
- Benchtop NMR (7)
- Benchtop-NMR (7)
- LA-ICP-MS (7)
- Laser ablation (7)
- GD-OES (5)
- HR-CS-GFMAS (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (126)
- 1.1 Anorganische Spurenanalytik (44)
- 6 Materialchemie (27)
- 1.6 Anorganische Referenzmaterialien (22)
- 1.7 Organische Spuren- und Lebensmittelanalytik (22)
- 1.8 Umweltanalytik (22)
- 1.4 Prozessanalytik (21)
- 4 Material und Umwelt (15)
- 6.3 Strukturanalytik (12)
- 6.6 Physik und chemische Analytik der Polymere (11)
SWIR luminescent nanomaterials – key chemical parameters for bright probes for in vivo bioimaging
(2024)
A current challenge for studying physio-pathological phenomena and diseaserelated processes in living organisms with non-invasive optical bioimaging is the development of bright optical reporters that enable deep tissue penetration, a high detection sensitivity, and a high spatial and temporal resolution. The focus of this project are nanomaterials, which absorb and emit in the shortwave infrared (SWIR) between ~900–2500 nm where scattering, absorption, and autofluorescence of the tissue are strongly reduced compared to the visible and NIR.
Oxidative degradation processes of tetrabromobisphenol A (TBBPA), a brominated flame retardant (BFR) in wood, plastics and electronics, were investigated by electrochemistry (EC) coupled online to electrospray ionization mass spectrometry (ESI/MS). Oxidative phase I and II metabolites production was achieved using an electrochemical flow-through cell equipped with a boron doped diamond electrode. Structural elucidation and prediction of oxidative metabolism pathways of TBBPA according to type II ipso-substitution were based on retention time, m/z ratio in negative mode and fragmentation pattern. Using the data obtained through high resolution MS analysis and the identification of single electron transfer (SET) as the initial step of a two-electron oxidation provided the necessary information to propose a mechanism for the electrochemical oxidation of TBBPA. Oxidation reactions involving aromatic hydroxylation and β-scission were the main degradation observed when studying the electrochemical behavior of TBBPA. Computational chemistry experiments using density functional theory (DFT) allowed to identify mono-hydroxylated reaction intermediate and dismissed the mechanism involving two concurrent hydroxylation. TBBPA oxidation products were compared to known metabolites of its biological and environmental degradation confirming the ability of electrochemistry to simulate β-scission reactions.
Faecal contaminants in water are considered serious threats for human health, due to the presence of viruses, bacteria and other harmful microorganisms.1 Urobilin (UB) is a well-known faecal pigment and can be used as a marker for faecal matter in water.2 UB is commonly present in the urine of all mammals as the catabolic end product of bilirubin degradation.2 As the only simple chemical approach to its detection, Schlesinger’s test is usually used to enhance the weak fluorescence of UB in alcoholic media by complexation with Zinc.2, 3 The major limitation of this method is the only weak enhancement of the intrinsically weak UB fluorescence in aqueous media.3 This work presents an approach to introduce different Zn salts for improved fluorescence response, where we found a clear dependence of the fluorescence yield of UB-Zn(II) complexes on the counterion of the salt in water. By employing a combination of fluorescence parameters like transition energy, fluorescence intensity, and fluorescence lifetime, a photophysical understanding of the structure and conformation of the UB-Zn(II) complexes responsible for the fluorescence enhancement in water could be gained. The possibilities of developing a sensitive analytical method based on the acquired understanding are also discussed.
Per- and polyfluoroalkyl substances (PFAS) were classified as a group of highly concerning chemicals over the last decades. Because of the high persistence of PFAS, their previous use led to contamination of the environment and human population. Due to ongoing use and incomplete remediation or destruction methods, the PFAS background in the environment is growing continuously.
The presence of ultrashort PFAS (with ≤3 carbon atoms) in the environment is often overlooked despite their contributions to PFAS levels. These compounds may directly contaminate the environment and arise from degradation of polyfluorinated compounds as well as incomplete PFAS destruction in certain industrial processes. Nonetheless, few approaches for targeted analysis of ultrashort PFASs have been developed, except for trifluoroacetic acid (TFA). Beside liquid (LC-MS/MS), supercritical fluid (SFC-MS/MS), and ion chromatography (IC-MS)-based systems, gas chromatography coupled with mass spectrometry (GC-MS) is a promising method for detection and quantification of ultrashort PFAS.
The goal of this study was to develop a simple headspace GC-MS method for the quantification of ultrashort perfluorocarboxylic acids (PFCAs) and polyfluorinated alcohols (PFOHs) in water samples. In contrast to PFOHs, functionalization of PFCAs was required for quantification. This was done by esterification with methanol at 80 °C, which can be carried out directly in the headspace GC-MS system.
Moreover, several parameters were optimized to achieve a low limit of quantification (LOQ) for the analytes used: i) The ratio of the aqueous solution, methanol, and available gas phase within the analysis vessel, ii) the concentration of additional acid in esterification mixtures of PFCAs, iii) shaking frequency and iv) shaking time before analysis. After optimizing the procedure, we were able to quantify ultrashort PFCAs and PFOHs. Thus, our developed headspace GC-MS method has the potential to be used as an alternative target analysis for ultrashort-chain PFCAs and PFOHs in various water samples (groundwater, wastewater).
Lithium-ion batteries are a key technology for tackling challenges in energy and climate crisis, but up to 30 % are discarded right after production. Quality is closely related to the homogeneity of the used materials and coatings. Fluorine compounds, both in the polymer and from degradation of the electrolyte, are of special interest for the formation and aging of LIBs. Glow-discharge optical emission spectroscopy (GD-OES) emerged as a fast and convenient method for depth-profiling of battery materials. However, fluorine remains a spectroscopic challenge due to a high excitation energy and only few strong emission lines in the UV/Vis spectral range.
We investigated the partial substitution of argon with neon in the plasma gas. The main emission line at 685.603 nm was monitored by both photo multiplier tube (PMT) with Czerny-Turner monochromator at 20 µm slit-size, and charge-coupled device (CCD) with 1200 lines/mm grating. For calibration, we used a set of hot-pressed copper cylinders with varying calcium fluoride amount fraction, ranging from 1.6 % to 4.4 %. Plasma gas mixtures with a mole fraction of 5 %, 10 % and 20 % neon in argon were used. Sensitivity in comparison to pure argon was increased by factor 4, 7 and 14, respectively. In general, PMT detection was more sensitive than CCD. As expected, sputter rates decreased with higher neon content in the plasma gas. Depth-profiling of the cathodes was performed in pulsed mode at constant voltage and pressure, which resulted in stable plasma conditions. We achieve matrix-independent quantitative information on fluorine distribution by correction based on sputter rates.
This advancement in GD-OES provides a more accurate analytical approach for evaluating the homogeneity of lithium-ion battery materials, potentially leading to more sustainable and cost-effective manufacturing processes.
We developed a two-step semi-synthesis for the preparation of isotopically labeled EAs, starting from native EAs. This universal strategy enabled the successful synthesis of all isotopically labeled priority EAs. The structure of the isotopically labeled EAs was confirmed by HPLC-HR-MS/MS using native, unlabeled EAs as a reference standard. The next step will be the implementation of the isotopically labeled standards in the European standard procedure EN 17425 to improve the quantification of EAs in foodstuffs.
The variation of isotope ratios is increasingly used to unravel natural and technical questions. With new upcoming techniques and research topics in the last two decades, such as material provenance or food authenticity to animal and human migration studies, the number of published isotope data has strongly increased. Here, isotope reference materials are indispensable to enable a reliable method validation or even SI-traceability. The fast development and broad availability of inductively coupled plasma mass spectrometry instrumentation (ICP-MS) also lead to an expansion of the classical research areas and new elements are under investigation. Owing to this large expansion of the field, the production and certification of isotope reference materials for calibration and validation is lagging behind, even for classical applications such as conventional 87Sr/86Sr isotope ratio analysis. To improve this situation, BAM organized an interlaboratory comparison (ILC) comprising of thirteen international laboratories for the characterisation of 87Sr/86Sr isotope ratios in geochemical and industrial reference materials. Six reference materials (four cements and two rocks) were provided as powder requiring extensive sample preparation prior to isotopic measurement. Additional requirements included the use of the conventional method for obtaining 87Sr/86Sr isotope ratios, also known as radiogenic 87Sr/86Sr isotope ratios, and the assessment of the measurement uncertainty. The primary goal was to evaluate potential differences in the application of multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for conventional 87Sr/86Sr isotope ratio determination, with a secondary goal to provide reference values for the 87Sr/86Sr isotope ratios in these potential new reference materials. All reported results are accompanied by an uncertainty statement and are traceable to the conventional method, which will be described in detail within this presentation. Current state-of-the-art statistical models were used to ensure the proper evaluation of the reported results and their associated measurement uncertainties within the frame of this ILC. Combined with results from appropriate homogeneity assessment, reference values for 87Sr/86Sr isotope ratios will be assigned.
Global demand for pigments is expected to increase to around 13.4 million tons per year by 2030, representing approximately $22 billion – 5% of which will be azo pigments as the main organic pigments. Azo pigments, i.e., especially the azo bridge required for them, are almost exclusively produced in technology by the so-called azo coupling reaction in large-scale approaches on the scale of 50–100 cubic meters. Among other things, one of the reasons why large-scale production itself is still essentially discontinuous is the lack of analytical methods for a continuous azo pigment synthesis.
In an azo coupling process, an aromatic amine is diazotized to form the diazonium compound (diazo compound), which then reacts with a coupling component, i.e., "couples". A slight excess of the coupler is desired for the end of the reaction, which stoichiometrically consumes the remaining (harmful) diazo compound, i.e., below 500 ppm. This is carried out with a manual spotting reaction of a fast-binding coupler.
To carry out continuous azo coupling, care must be taken to ensure that the actual coupling reaction proceeds as rapidly as possible, i.e., preferentially, compared with possible side reactions. Reliable measuring methods are thus a decisive criterion for the useful performance of a continuous azo pigment synthesis. An analytical online procedure is difficult due to several limitations at once: solid dispersions extremely limit the range of reproducible analytical procedures. In addition, the appearance of a signal (e.g., excess of a starting material) in the ppm range must be reliably detected against the matrix background.
The back-titration method and benchtop NMR spectroscopy were used to overcome these problems. We present a feasibility study for a suitable process analysis with benchtop NMR spectroscopy on disperse systems for equimolar dosing of the "diazotization" or "coupling" sub-step in azo coupling, which was carried out in cooperation with a chemical company. This could replace tedious manual spotting
The application of compact NMR instruments to continuously flowing samples at higher temperatures or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is typically not designed for compensation of such effects. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements using an optical thermo-graphy setup, a model predictive control was set up to minimize any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, potentially extend the application of compact NMR instruments to flowing samples at higher temperature than the permanent magnet.
The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature.
Compact NMR Spectroscopy in the field: A Versatile PAT Tool for Production of Specialty Chemicals
(2023)
Companies of chemical industry find themselves more often in a rapidly changing environment, e.g., due to variability of raw material quality or energy costs and efficiency. Process optimization and new process concepts become more and more important. For example, flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds like exothermic reactions with high heat dissipation.
Highly automated “chemical” process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. A commercially available benchtop NMR spectrometer was integrated to the full requirements of an automated chemical production environment such as explosion safety, field communication, and robust evaluation of sensor data. Field studies in modular and conventional production plant setups show promising results gaining process knowledge for further optimization. NMR appeared as preeminent online analytical method and allow using a modular data analysis approach, which can even serve as reliable reference method for further calibration-dependent PAT applications (e.g., NIR or Raman spectroscopy).
Based on experiences from earlier field studies an improved NMR analyzer enclosure setup was developed and built, including the option of a secondary method (e.g., optical spectroscopy). Integrated control systems allow for a flexible implementation based on the available automation infrastructure at the chemical plant or pilot plant setup. In the future, fully integrated and intelligently interconnecting “smart” PAT systems and processes have the potential speed up the setup of production equipment for chemicals and pharmaceuticals and therefore help to reduce the time-to-market.
Iron isotopes are used in a variety of fields from e.g., geologic question to medical applications. Measurements of iron isotopes are usually performed as delta measurements to an artificial based delta zero standard. In the case of Fe isotopes is that delta zero standard IRMM-014, a pure Fe metal. Unfortunately, that conventional delta zero reference material defining the 56/54Fe scale is out of stock and therefore unavailable. To overcome that situation and fulfill the need for laboratories that measure Fe isotope on a regular basis we will provide a set of solutions with IRMM-014 and a second anchor point for Fe isotope ratio measurements that is based on a pure Fe metal. This new second anchor point, a high purity Fe from BAM, will be calibrated against IRMM-014 and can be used as bracketing standard or as reference value for stable Fe isotope measurements.
We are in the good situation that BAM ordered a large stock of IRMM-014 several years ago. That stock of IRMM-014 Fe cubes and IRMM-014 Fe wires will be dissolved in 6M HCl in a large quantity. The new anchor point, the high purity Fe metal, that is commercially available at BAM, is a pure Fe metal with only trace amounts of impurities. The high purity BAM material will also be dissolved in 6M HCl in large quantity. Several aliquots of both solutions will be measured on the Neptune Plus MC-ICP-MS to define this second anchor point with a low uncertainty. Further will we send several aliquots of both solutions to different laboratories to also measure this second anchor point of high purity Fe on the 56/54Fe scale.
We will report the values of that study on BAM high purity Fe and will provide a guide for scale conversion to the IRMM-014 scale and for uncertainty calculation to use that new anchor point instead of the exhausted IRMM-014.
Introduction
Lithium-ion batteries (LIBs) are one key technology to overcome the climate crisis and energy transition challenges. Demands of electric vehicles on higher capacity and power drives research on innovative cathode and anode materials. These high energy-density LIBs are operated at higher voltages, leading to increased electrolyte decay and the current collectors' degradation. Even though this fundamental corrosion process significantly affects battery performance, insufficient research is being done on the aluminum current collector. Fast and convenient analytical methods are needed for monitoring the aging processes in LIBs.
Methods
In this work glow-discharge optical emission spectrometry (GD-OES) was used for depth profile analysis of aged cathode material. The measurements were performed in pulsed radio frequency mode. Under soft and controlled plasma conditions, high-resolution local determination (in depth) of the elemental composition is possible. Scanning electron microscopy (SEM) combined with a focused ion beam (FIB) cutting and energy dispersive X-ray spectroscopy (EDX) was used to confirm GD-OES results and obtain additional information on elemental distribution.
Results
The aging of coin cells manufactured with different cathode materials (LCO, LMO, NMC111, NMC424, NMC532, NMC622, and NMC811) was studied. GD-OES depth profiling of new and aged cathode materials was performed. Quantitative analysis was possible through calibration with synthetic standards and correction by sputter rate. Different amounts of aluminum deposit on the cathode surface were found for different materials. The deposit has its origin in the corrosion of the aluminum current collector. The results are compatible with results from FIB-EDX. However, GD-OES is a faster and less laborious analytical method. Therefore, it will accelerate research on corrosion processes in high energy-density batteries.
Innovative aspects
- Quantitative depth profiling of cathode material
-Monitoring of corrosion processes in high energy-density lithium-ion batteries
- Systematic investigation of the influence of different cathode materials
ISO 14687 defines threshold limits for expectable impurities in hydrogen that is assigned for use in polymer electrolyte membrane (PEM) fuel cells. This work describes the establishment of the traceability of some selected impurities by preparation and analysis of reference gases with the lowest possible uncertainty in composition. Primary reference gases were produced by the gravimetric method according to ISO 6142-1 and the analysis was carried out by operating measurement protocols according to ISO 12963 on two customized trace GC analysers.
Over the past century, a range of synthetic compounds have been produced to improve humanity’s quality of life. These include pharmaceuticals, plastics, and other chemical compounds that possess properties making them potentially harmful when released to the environment (e.g., ecological and health impacts to humans and animals). Per- and polyfluoroalkyl substances (PFAS) are a large group of chemicals used in the formulations of thousands of consumer goods, including aqueous film-forming foams used to suppress aviation fires in training scenarios, non-stick cookware, fast-food wrappers, water-repellent fabrics, medical equipment, and plastic and leather products. Because of the recent regulations and restrictions on the use of long chain (≥C8) PFAS a significant shift in the industry towards short (C4-C7) and ultrashort (C1-C3) chain alternatives has been recognized the last years. Due to the high polarity and water solubility of ultrashort PFAS, the potential for bioaccumulation is low. However, the high persistence of ultrashort-chain PFAS will result in environmental accumulation, especially in aquatic environments, leading to potential risks for aquatic organisms and increased human external exposure through drinking water. Ultrashort PFAS like trifluoroacetic acid (TFA) are low to moderately toxic to a range of organisms. In addition, ultrashort PFAS can penetrate natural and anthropogenic barriers and eventually reach drinking water sources. Because common drinking water treatment techniques do not sufficiently remove them, they may reach human consumption. In the project we are focusing on detecting and removing PFAS, especially ultrashort-chain PFAS from contaminated groundwater. We are designing passive sampling devices, which can collect and monitor the temporal profile of PFAS species in groundwater. This will allow us to analyze PFAS contaminations in German and Israeli groundwater using state-of-the-art and novel analytical techniques and understand the extent of contamination. In addition to quantification, PFAS contaminated groundwater will be treated via a two-stage process to produce PFAS-free drinking water. As ultrashort-chain PFAS are difficult to analyze with the current target (LC-MS/MS) and sum parameter (AOF, EOF) analysis methods, we additionally using gas chromatography – mass spectrometry (GC-MS). Therefore, an analytical method based on GC-MS is in development to analyze the volatile ultrashort-chain PFAS (TFA, PFPrA, TFMS, PFEtS, PFPrS, trifluoroethanol, pentafluoropropanol and hexafluoro isopropanol) directly in contaminated groundwater samples with the headspace technique and in eluates of organic solvents from the developed passive sampler after direct injection. Moreover, a two-stages process is designed to increase the low concentrations found in groundwater using novel membranes processes such as closed-circuit reverse osmosis (CCRO) and mixed matrix composite nanofiltration membranes (MMCM). Next, the rejected streams containing higher concentrations of PFAS will be treated by coagulation, and the remaining PFAS adsorbed onto carbonaceous nanomaterials (CNMs). The DEFEAT-PFAS project will result in the development of novel tools to detect, quantify, and remove PFAS, especially ultrashort-chain PFAS from contaminated groundwater, and will acquire a new understanding of the extent of these contaminations.
HR-CS-GFMAS turned out to be a sensitive, fast and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) at a temperature of 1550°C. GaF can be detected at 211.248 nm providing limits of quantificationin the low μg/L range. However, several species specific effects where observed when analyzing PFASs.
Ergot alkaloids form a toxicologically relevant group of mould toxins (mycotoxins) that are among the most common contaminants of foodstuff and animal feed worldwide. Reliable controls are essential to minimise health risks and economic damage. Due to their toxicological relevance, EU limit values for 12 priority ergot alkaloids have been introduced for the first time in 2022 and range from 500 μg/kg in rye milling products down to 20 ug/kg Processed cereal-based foods for infants and young children[1]. High-performance liquid chromatography - mass spectrometry is used to quantify low concentrations of ergots in food, however the European standard analytical procedure cannot be applied due to the lack of isotopically labelled reference standards.
The complex structure of the ergot alkaloids makes a total synthesis extremely challenging, expensive and time-consuming. Therefore, we are focusing on different semi-preparative methods (electrochemistry, organic synthesis, heterogeneous catalysis) to specifically N-demethylate the C8 carbon atom of the lysergic acid moiety. The norergot alkaloid formed is then isotopically labelled using an electrophilic methyl source, i.e. iodomethane or dimethyl sulphate to obtain the specific isotopic labelled ergot alkaloid. Initial experiments have shown that N-demethylation of the ergot alkaloid ergotamine is possible by both electrochemical and wet-chemical organic synthesis. The next step is to improve the previously determined reaction conditions to enable the synthesis of norergotamine on a mg scale for further reactions.
Ergot alkaloids form a toxicologically relevant group of mould toxins (mycotoxins) that are among the most common contaminants of food and animal feed worldwide. Reliable controls are essential to minimise health risks and economic damage. Due to their toxicological relevance, EU limit values for 12 priority ergot alkaloids have been introduced for the first time in 2022 and range from 500 µg/kg in rye milling products down to 20 ug/kg Processed cereal-based foods for infants and young children[1]. High-performance liquid chromatography - mass spectrometry is used to quantify low concentrations of ergots in food, however the European standard analytical procedure cannot be applied due to the lack of isotopically labelled reference standards.
The complex structure of the ergot alkaloids makes a total synthesis extremely challenging, expensive and time-consuming. Therefore, we are focusing on different semi-preparative methods (electrochemistry, organic synthesis, heterogeneous catalysis) to specifically N-demethylate the C8 carbon atom of the lysergic acid moiety. The norergot alkaloid formed is then isotopically labelled using an electrophilic methyl source, i.e. iodomethane or dimethyl sulphate to obtain the specific isotopic labelled ergot alkaloid. Initial experiments have shown that N-demethylation of the ergot alkaloid ergotamine is possible by both electrochemical and wet-chemical organic synthesis. The next step is to adapt the previously determined reaction conditions to enable the synthesis of norergotamine on a mg scale.
Per- and polyfluoroalkyl substances (PFAS) are a large, ever-growing and widely used class of chemicals. Due to the strength of the C-F bond, they do not decompose but accumulate in the environment posing a risk for nature and humans alike. While the use of some PFAS, like perfluorooctanoic acid (PFOA) is already regulated in the EU, new ‘precursor’ substances are used to replace them. However, these precursors may be equally harmful to the environment.
In recent years, many ‘hot spot’ sites with high PFAS contaminations in soil have been distinguished, but no German-wide background values have been determined yet. Knowing these background values is crucial to understand the degree of PFAS contamination, underpinning future regulatory decisions.
Due to the complexity and variety of different PFAS compounds, one needs to apply a broad spectrum of different techniques to capture most of the PFAS content in one sample.
In the framework of this project, 600 soil samples are taken at different sites all over Germany. The concentration of 30 PFAS - 13 carboxylic acids (C4-C18), 5 sulfonic acids (C4-C10) and 12 precursor substances) - is determined in these soil samples using three different sample preparation approaches: 1) ultrasonic extraction of the soil samples with Methanol; 2) preparation of eluates to test the leaching behaviour of the PFAS and 3) TOP assays following the method published by Houtz & Sedlak.
Targeted LC-MS/MS is used to determine PFAS concentration after all three preparation steps.
For the TOP-assay, the concentration of all 30 PFAS is compared prior to and after the oxidation reaction.
Besides the ‘classic’ TOP-Assay, two other TOP-Assay approaches, the dTOP Assay and the photoTOP-Assay, are tested and the results of all three approaches are compared. First, all three TOP-Assay approaches will be tested on a reference soil spiked with a solution including all 30 PFAS measured in the project. Later, soil samples taken in the frame of the priorly described project will be tested.
This poster will focus on the results of the experiments comparing the three different TOP Assay approaches in spiked reference soil. Additionally, some of the results of the other sample preparation methods, extraction and eluate preparation will be presented.
In the interest of exploring their potential in the field of single particle analysis, a Microdroplet Generator (MDG) was coupled to an ICP-ToF-MS. Isotopic Dilution Analysis was also incorporated for the size determination of three different Platinum nanoparticles samples (50, 63 and 70 nm). The performance of the technique was validated by comparison to traditional size characterization techniques (sp-ICP-ToF-MS, TEM), while the robustness of the technique was proven by incorporating NaCl in the samples’ matrix, up to 100 mg/L.