Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Vortrag (360) (entfernen)
Sprache
- Englisch (264)
- Deutsch (94)
- Mehrsprachig (2)
Referierte Publikation
- nein (360)
Schlagworte
- Mikroplastik (21)
- Synchrotron (19)
- Process Analytical Technology (18)
- BAMline (16)
- XRF (16)
- Online NMR Spectroscopy (15)
- HR-CS-GFMAS (13)
- Prozessanalytik (13)
- PFAS (12)
- ICP-MS (11)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (252)
- 1.1 Anorganische Spurenanalytik (98)
- 6 Materialchemie (85)
- 1.4 Prozessanalytik (76)
- 1.6 Anorganische Referenzmaterialien (50)
- 6.6 Physik und chemische Analytik der Polymere (41)
- 6.3 Strukturanalytik (37)
- 4 Material und Umwelt (30)
- 1.8 Umweltanalytik (24)
- 1.7 Organische Spuren- und Lebensmittelanalytik (20)
Therapeutic monoclonal antibodies are the fastest-growing group of biological agents which generated a yearly turnover of USD 210 billion in 2022 and whose sales are expected to grow by 10% annually over the next 10 years. With steadily increasing market importance, analytical methods for reliable quantification of therapeutic antibodies also become more and more relevant. Liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) has become the main technology for antibody quantification. This approach, however, requires enzymatic digestion of the intact protein into peptides, for which a wide range of different protocols exists that often lead to different results depending on the digestion procedure or trypsin variants used. In particular, the amount and type of detergents added for protein unfolding prior to digestion is known to create significant bias in measurement results. The overall goal of the presented project is the application of novel thermostable and surface-functionalized trypsin particles for improved antibody digestion. Specifically, a trypsin-variant described in the literature exhibiting increased activity and thermal stability above 80°C, will be examined. The application of this enzyme should allow to perform digestion at elevated temperatures where the protein is naturally unfolding thereby increasing enzyme accessibility without the need for detergents. Furthermore, we will immobilize the thermostable trypsin onto the surface to further enhance enzyme stability, prevent self-digestion, and enable separation of trypsin from target peptides before LC–MS/MS analysis. As an immobilization platform, cheap and non-porous corundum particles will be used as these show high chemical stability and low levels of interaction of matrix proteins with the functionalized surface. adsorption. In a multidisciplinary collaboration with the SALSA Photonics Lab, we will investigate the characteristics of covalent enzyme binding and unspecific peptide binding using an interface-sensitive analytical tool, vibrational sum-frequency generation (VSFG) spectroscopy. The insights gained will not only lead to new competencies in peptide and enzyme surface analysis using VSFG spectroscopy in SALSA but will also significantly contribute to optimizing antibody quantification.
Die Angabe von Unsicherheiten bei zertifizierten Werten von Referenzmaterialien ist von entscheidender Bedeutung. Die korrekte Einbindung der Unsicherheiten zur Berechnung von Verfahrensmessunsicherheiten ist wesentlich für die Gewährleistung der Genauigkeit und Zuverlässigkeit von Messungen. In diesem Vortrag werden die verschiedenen Einflussfaktoren auf die Unsicherheit zertifizierter Werte gemäß ISO Guide 35 dargestellt. Dabei werden insbesondere die Charakterisierung, Homogenität und Stabilität als entscheidende Faktoren für die Bestimmung der Unsicherheit eines Referenzmaterials betrachtet. Abschließend wird das Konzept anhand eines konkreten Beispiels veranschaulicht, um die praktische Anwendung und die Auswirkungen auf die Berechnung von Verfahrensmessunsicherheiten zu verdeutlichen.
This presentation highlights ongoing scientific misconduct as found in academic literature. This includes data- and image manipulation, and paper mills. Starting with an expose of examples, it delves deeper into the causes and metrics driving this phenomenon. Finally a range of possible tools is presented, that the young researcher can use to prevent themselves from sliding into the dark scientific methods.
By automatically recording as much information as possible in automated laboratory setups, reproducibility and traceability of experiments are vastly improved. This presentation shows what such an approach means for the quality of experiments in an X-ray scattering laboratory and an automated synthesis set-up.
Metabolomics
(2024)
In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. VOC in combination may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. Emission concentrations can become further elevated in new or refurbished buildings where the rate of air exchange with fresh ambient air may be limited due to improved energy saving aspects. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use (building) materials proved to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable emission reference materials (ERM). For the emission test chamber procedure according to EN 16516, no artificial ERM is commercially available. The EU-funded EMPIR project MetrIAQ aims to fill this gap by developing new and improved ERMs. The goal is to obtain a material with a reproducible and temporally constant compound release (less than 10 % variability over 14 days). Two approaches were tested: the impregnation of porous materials with VOC, and the encapsulation of VOC in polymer microcapsules. Impregnation is performed with help of an autoclave and supercritical CO2. The encapsulation is done by interfacial polymerisation on VOC droplets. For both approaches, synthesis and/or material parameters were varied to obtain an optimal ERM. Findings about the optimisation of ERM generation, as well as performance of the best emission reference materials, will be presented.
The principles of (Hard) X-ray photoelectron spectroscopy and some application in the field of (core-shell) nanoparticles will be presented. The presentation should answer hoe to get reliable results. Furthermore, examples of the correlation between physical-chemical measurments and toxicological results are given which are crucial for the risk assessment of nanoparticles.
An overview of personal experience with laser-induced plasma (LIP) will be given. The combination of LIP with laser-induced fluorescence, atomic absorption, Raman spectroscopy and spatial heterodyne spectroscopy for elemental and isotopic analysis will be discussed. Unusual applications of LIP will be covered, such as LIP-based lasers and LIP-based chemical reactors.
This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, micro reactions, pump and probe diagnostics, tomography,
temporal and spatial resolution. Basis of plasma computer modeling will be presented.
X-rays without X-rays: Can muon tomography provide pictures from within concrete and other objects?
(2024)
Until the 1980s radiography was used to inspect civil structures in case of special demands and showed a much better resolution than other NDT techniques. However, due to safety concerns and cost issues, this method is almost never used anymore. Meanwhile, non-destructive techniques such as ultrasound or
radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features when applied to reinforced or prestressed concrete inspection.
Muon tomography has received much attention recently. Muons are particles generated naturally by cosmic rays in the upper atmosphere and pose no risk to humans. Novel detectors and tomographic imaging algorithms have opened new fields of application, mainly in the nuclear sector, but also in spectacular cases such as the Egyptian pyramids.
As a first step towards practical application in civil engineering and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results have been at least of similar quality compared to ultrasonic and radar imaging, potentially even better. Recently, the research was expanded to more realistic testing problems such as the detection of voids in certain structural elements. However, before practical implementation, more robust, mobile, and affordable detectors would be required as well as user-Friendly imaging and simulation software.
The talk also discusses other applications , such as volcanology, mining and geothermal exploration.
Sr isotope ratio analysis
(2023)
Pb isotope ratio analysis
(2023)
Detector deadtime
(2023)
Isotope Ratio Analysis
(2023)
Thermal Destruction of PFAS
(2023)
Thermal treatment processes are currently the only full-scale option for thedestruction of per- and polyfluoroalkyl substances (PFAS) in large waste streams. While all organic molecules including PFAS are susceptible to thermal destruction, their decomposition rates are controlled by process variables such as temperature, reaction atmosphere, and residence time. Concerns exist about the formation of products of incomplete destruction and their emission from hazardous waste incinerators. This talk will summarize the current stateof-the-art of thermal PFAS destruction, identify research needs, and showcase future research designed to address critical knowledge gaps.
Die NMR-Spektroskopie ist eine der zentralen nicht-invasiven Analysenmethoden in der organischen Chemie und aus dem Laboralltag nicht mehr wegzudenken. Die direkte Proportionalität zwischen der Anzahl der Atomkerne im Messvolumen und der Signalfläche im Spektrum ist vergleichbar mit einem „Zählen der Kernspins“. Der Kalibrieraufwand für die Quantifizierung ist minimal und aus dem NMR-Spektrum sind Informationen zu Struktur und Identität zugänglich.
Online-NMR-Spektroskopie wird unter Zuhilfenahme von speziellen Durchflussproben-köpfen und Messzellen bereits seit Jahrzehnten erforscht und eingesetzt. Durch die hohen Anforderungen an die Aufstellung und den Betrieb von klassischen Hochfeld-NMR-Spektrometern konnte sie allerdings nie den Sprung vom Labor in den Prozess schaffen. Dies hat sich durch die Entwicklungen im Bereich mobil einsetzbarer Benchtop-NMR-Spektrometer grundlegend verändert. Geringere Investitions- und Betriebskosten, sowie die Robustheit und einfache Bedienbarkeit dieser Systeme sind entscheidende Faktoren. Damit rückt eine Anwendung als Online-PAT-Methode technisch in greifbare Nähe. Designierte Prozess-NMR-Spektrometer sucht man heutzutage allerdings auf dem Markt meist noch vergebens.
Die Reaktionsverfolgung im Labormaßstab konnte an unterschiedlichen Systemen erfolgreich demonstriert werden. Dabei zeigten sich allerdings Limitierungen in Hinblick auf einen möglichen Prozesseinsatz. Insbesondere die Temperaturempfindlichkeit der Magnetsysteme ist hier zu nennen. Anhand eines Prototyps wurde eine aktive Temperaturisolation mittels temperierter Luftströmungen entwickelt und erprobt.
Eine Feldintegration von Laborsystemen geht sowohl technisch als auch regulatorisch mit zahlreichen Herausforderungen einher. Das raue Umfeld von Produktionsanlagen, sowie die Anforderungen an Explosionsschutz erfordern eine zugelassene Einhausung. Auf Basis von Erfahrungen mit einem ersten Prototyp erfolgte die gemeinsame Entwicklung eines möglichst flexibel einsetzbaren Analysenschranks. Neben der Hardware-Integration sind die automatisierte modellbasierte Auswertung der NMR-Spektren, sowie die Einbindung in die Prozessleittechnik essenziell für einen zuverlässigen Betrieb als PAT-Analysengerät.
Referenzmaterialien sind unter anderem ein wichtiges Werkzeug zur Qualitätskontrolle von Messungen bestimmter Merkmalswerte. Dabei ist zu berücksichtigen, dass zertifizierte Merkmalswerte immer eine gewisse Unsicherheit haben. Die Ermittlung dieser Unsicherheitsbeiträge ist Gegenstand des Vortrags. Referenzmaterialien sind gleichzeitig ein wertvolles Werkzeug zur Ermittlung der Unsicherheit von Messverfahren und -Analysen unbekannter Proben. Die Vorgehensweise bei der Ermittlung der Messunsicherheit mit Hilfe eines Referenzmaterials wird beschrieben.
Referenzmaterialien sind unter anderem ein wichtiges Werkzeug zur Qualitätskontrolle von Messungen bestimmter Merkmalswerte. Dabei ist zu berücksichtigen, dass zertifizierte Merkmalswerte immer eine gewisse Unsicherheit haben. Die Ermittlung dieser Unsicherheitsbeiträge ist Gegenstand des Vortrags. Referenzmaterialien sind gleichzeitig ein wertvolles Werkzeug zur Ermittlung der Unsicherheit von Messverfahren und -Analysen unbekannter Proben. Die Vorgehensweise bei der Ermittlung der Messunsicherheit mit Hilfe eines Referenzmaterials wird beschrieben.