Chemische Charakterisierung und Spurenanalytik
Filtern
Erscheinungsjahr
- 2022 (25) (entfernen)
Dokumenttyp
- Posterpräsentation (25) (entfernen)
Referierte Publikation
- nein (25)
Schlagworte
- Process Analytical Technology (4)
- Benchtop NMR (3)
- Modular production (3)
- BAMline (2)
- Fluorine (2)
- HR-CS-GFMAS (2)
- Machine Learning (2)
- PFAS (2)
- Soil (2)
- TED-GC/MS (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (17)
- 6 Materialchemie (6)
- 1.8 Umweltanalytik (5)
- 1.1 Anorganische Spurenanalytik (4)
- 1.4 Prozessanalytik (4)
- 4 Material und Umwelt (4)
- 1.6 Anorganische Referenzmaterialien (3)
- 6.3 Strukturanalytik (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
Contamination of the environment with antibiotics is of great concern as it promotes the evolution of antimicrobial resistances. In case of amoxicillin (AMX) in the aquatic environment, further risk arises from hydrolysis products (HPs) which can cause allergy. To assess these risks, a comprehensive investigation and understanding of the degradation of AMX is necessary. We investigated the hydrolysis rate of AMX in different types of water as well as the influence of temperature and irradiation. The content of the heavy metal ions copper and zinc was found to be crucial for the hydrolysis rate of AMX and stability of HPs. Eventually, a new degradation pathway for AMX could be elaborated and confirmed by tandem mass spectrometry (LC-MS/MS).
Steps Forward in the Application of 3,3’,5,5’- Tetramethylbenzidine (TMB) in Amperometric Assays
(2022)
Electrochemical methods make great promise to meet the demand for user-friendly on-site devices for monitoring important parameters. Food industry often runs own lab procedures, e.g. for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with miniaturized technologies. Enzyme-linked immunosorbent assays, with photometric detection of the horseradish peroxidase (HRP) substrate, 3,3’,5,5’-tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straight-forward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material.
It was found that screen-printed gold electrodes and a highly acidic pH value (pH 1) are well-suited to perform the electrochemical detection of TMB, due to the reversible character of the redox reaction under these conditions. This set-up provides a good signal stability over several measuring cycles, providing the basis for analysing multiple samples. In contrast to this, for carbon screen-printed electrodes, it was found that the signal response has changed after the electrochemical reaction with TMB at pH 1. At a weakly acidic pH value (pH 4), neither with carbon nor with gold electrodes a reproducible electrochemical detection of TMB could be achieved [1].
Based on these findings we created a smartphone-based, electrochemical, immunomagnetic assay for the detection of ochratoxin A and ergometrine in real samples. Therefore, a competitive assay was performed on magnetic beads using HRP and TMB/H2O2 to generate the signal. Enzymatically oxidized TMB was quantified after addition of H2SO4 by amperometry with screen-printed gold electrodes in a custom-made wall-jet flow cell. The results are in good correlation with the established photometric detection method, providing a solid basis for sensing of further analytes in HRP-based assays using the newly developed miniaturized smartphone-based, electrochemical, immunomagnetic assay.
Die Thermo Extraktion Desorption Gas Chromatograpie Massen Spektrometrie (TED-GC/MS) ist ein schnelles thermoanalytisches Verfahren zur Bestimmung von Gehalten an Mikroplastik (MP). Die Kombination aus teils schwerflüchtigen Analyten und Kältebrücken führt zu Memory-Effekten, denen u.a. durch häufige Blindwertmessungen begegnet werden muss. Reduzierte Probedurchsätze sind die Folge. Um Messergebnisse abzusichern und den Gerätestatus bei gleichzeitig hoher Messleistung überwachen zu können, wurde die sequentielle Standardmethode überarbeitet.
Lithium-ion batteries (LIBs) are one technology to overcome the challenges of climate and energy crisis. They are widely used in electric vehicles, consumer electronics, or as storage for renewable energy sources. However, despite innovations in batteries' components like cathode and anode materials, separators, and electrolytes, the aging mechanism related to metallic aluminum current collector degradation causes a significant drop in their performance and prevents the durable use of LIBs. Glow-discharge optical emission spectroscopy (GD-OES) is a powerful method for depth-profiling of batteries' electrode materials. This work investigates aging-induced aluminum deposition on commercial lithium cobalt oxide (LCO) batteries' cathodes. The results illustrate the depth-resolved elemental distribution from the cathode surface to the current collector. An accumulation of aluminum is found on the cathode surface by GD-OES, consistent with results from energy-dispersive X-ray spectroscopy (EDX) combined with focused ion beam (FIB) cutting. In comparison to FIB-EDX, GD-OES allows a fast and manageable depth-profiling. Results from different positions on an aged cathode indicate an inhomogeneous aluminum film growth on the surface. The conclusions from these experiments can lead to a better understanding of the degradation of the aluminum current collector, thus leading to higher lifetimes of LIBs.
Bisphenol A (BPA) is used in Polycarbonate, Polyacrylic resins, Polysulfones, Epoxy resins, and Polyetherimides. It is also used in recycled Polyvinyl chloride [1–3]. BPA has been classified as a substance of very high concern (SVHC) under REACH [4] due to its endocrine disrupting properties. The German competent authorities want to reduce the content of BPA in the environment. Possible substitutes for BPA are Bisphenol B (BPB), Bisphenol E (BPE),
Bisphenol F (BPF), or Bisphenol S (BPS), as they are similar in structure.
BPA-based materials have a wide area of application especially outside. These outdoor applications are exposed to different external influences, including physical, biological, mechanical and chemical influences. This results in damage and aging of the material with leaching or migration into the environment. There, the substance is transformed by various transformation processes. The emerging metabolites and transformation products (TPs) can have different properties than the parent substance. Understanding the fate and behavior of the emerging pollutants is very important.
Therefore, different transformation products of selected bisphenols will be generated and analyzed:
To investigate the fate of different bisphenols in water treatment plants technical transformation products [5] will be generated by chlorination, ozonization, the Fenton reaction, and UV-radiation.
For the investigation of the fate of Bisphenols in surface water global radiation will be simulated with UVA-lamps
Simulation of phase-I-metabolism with an electrochemical cell coupled to mass spectrometry (EC-MS).
Per- and polyfluorinated alkyl substances (PFASs) are a group of several thousand individual compounds. Many PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their various chemical and physical properties as well as the high number of compounds. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate realistic PFAS pollution levels.
PFAS sum parameters display the proportion of organically bound fluorine that can either be extracted (EOF) or adsorbed to activated carbon (AOF). For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) is a sensitive and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L.
In the present work a HR-CS-GFMAS method for EOF analysis was utilized for suspended particulate matter (SPM) analysis in German rivers in time lines from 2005–2020. Therefore, time and spatial resolved trends were investigated. In addition, SPM samples were analyzed for the Σ41PFAS using target analysis based on UHPLC-HRMS. Overall, target analysis drastically underestimated the total PFAS burden in SPM of German rivers compared to the EOF HR-CS-GFMAS analysis. Using a fluorine mass balance approach, only 0.2% to 38.6% of the EOF was explainable using the Σ41PFAS determined with target analysis. Our study highlights the need to integrate PFAS sum parameters (e.g., EOF with HR-CS-GFMAS) in PFAS risk assessment strategies.
Getting more efficient – The use of Bayesian optimization and Gaussian processes at the BAMline
(2022)
For more than 20 years, BAM is operating the BAMline at the synchrotron BESSY II in Berlin Adlershof. During this time, the complexity of the setup and the amount of data generated have multiplied. To increase the effectiveness and in preparation for BESSY III, algorithms from the field of machine learning are increasingly used.
After a short introduction to BO and GP, the first example is the automatic alignment of our double multilayer monochromator (DMM).
The second example is the optimization of measurement time in XRF scanning.
With the online coupling (or hyphenation) of chemically-resolved spectroscopy detection with classical size-exclusion chromatography (SEC) it is possible to correlate polymer molecular size with chemical structure in a single in-situ or on-flow measurement. Medium-resolution 1H-NMR (60 MHz) spectroscopy (i.e., “desktop NMR”) and Fouriertransform Infrared Spectroscopy (FTIR) have both been developed as coupled methods (SEC-MR-NMR, SEC-FTIR) for the detection of polymer analytes by monitoring e.g. alkene or carbonyl functionality.1,2 Here, we have investigated the potential for the detection of polymer end groups, using a slightly higher field-strength spectrometer (80 MHz 1H Larmor frequency) and taking advantage of a columnless injection method that provides bulk spectra for reference. End-functionalized polymers were synthesized by reaction of PEG with toluene isocyanate, yielding ,-functionalized polymers with exactly 2 IR- and NMR-detectable functional groups per chain, as proven by MALD-TOF mass spectrometry. We have investigated the sensitivity (limit of detection) and spectral resolution for these functional groups in chloroform, THF, and water. Results have demonstrated a good feasibility for the simultaneous online detection of PEG backbone (M~4000 g/mol) and these end groups at the level of ca. 2 mol%.
Our aim is to develop a simple and inexpensive method for full field X-ray fluorescence imaging.We combine an energydispersive array detector with a coded aperture to obtain high resolut ion images. To obtain the information from the recorded image a reconstruction step is necessary. The reconstruction methods we have developed, were tested on simulated data and then applied to experimental data. The first tests were carried out at the BAMline @BESSY II. This method enables the simultaneous detection of multiple elements,which is important e.g. in the field of catalysis.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve.
The project EDC-WFD Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17E2) and estriol (E3) will be included to demonstrate the reliability of the developed methods and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four selected effect-based methods (EBM) will be deeply investigated in order to improve their rationale use and their support in water quality assessment. In particular, the EBM sensitivity, specificity and accuracy on reference materials with single or mixture solutions of the five substances at a concentration of EQS values will be explored.
This contribution will present the objectives and methods applied within the EDC-WFD project.
Per- and polyfluoroalkyl substances (PFAS) are a large group of organofluorine surfactants used in the formulations of thousands of consumer goods, including aqueous film-forming foams (AFFF) used to suppress aviation fires in training scenarios, non-stick cookware, fast-food wrappers, water-repellent fabrics, medical equipment, and plastic and leather products. As a result of the perpetual use of PFAS containing products, effluents and sewage sludge from wastewater treatment plants (WWTPs) have been observed to be an important pathway for PFAS into the environment. In Germany, phosphorus and other nutrients from sewage sludge and wastewater should be recycled in WWTPs of cities with a large population. However, it is not clear if PFAS contamination from wastewater and sewage sludge end up in novel wastewater-based fertilizers. Normally, PFAS are analyzed using PFAS protocols typically with time-consuming extraction steps and LC-MS-MS quantification. However, for screening of PFAS contaminations in sewage sludge or wastewater-based fertilizers also passive sampler based on the Diffusive Gradients in Thin-films (DGT) technique can be used for the PFAS extraction. Afterwards, combustion ion chromatography (CIC) can be applied to analyse the “total” amount of PFAS on the passive sampler. Here, we show results from the DGT method in comparison to those of the extractable organic fluorine (EOF) method for a variety of wastewater-based fertilizers. Additionally, we analysed the adsorption of PFAS on the weak anion exchanger (WAX) based DGT passive sampler binding layer by infrared and fluorine K-edge X-ray adsorption near-edge structure (XANES) spectroscopy.
Several aspects were explored towards the standardization of a suitable procedure. The use of gaseous standards is necessary and a standard gas mixture containing 60 substances was successfully generated and employed for further investigations. The suitability of different chromatography columns was addressed: The use of PLOT (Porous Layer Open Tubular) columns is well suitable for VVOC analysis. The recoveries of the 60 analytes on several adsorbents and their combinations were determined: A combination of a graphitized carbon black and a carbon molecular sieve showed great results for all analytes. Carbon molecular sieves adsorb water which can impair the analysis. Different options such as purging, the use of a drying system or splitting were investigated for water removal. This contribution will present experimental results supporting the standardization of a method for VVOC analysis.
Soil acts as a final sink for pollutants. Microplastics from different sources such as plastic mulching, littering, compost, sewage sludge, sedimentary deposition, and tyre abrasion are expected to be found in soil. However, representative and comprehensive information is missing on the sources, transport, and fate. Therefore, a reliable analysis method for microplastics in soils needs to be developed.
The presented work describes the development of a procedure for microplastics analysis in soils. A representative sampling based on the on-site conditions and a sample preparation method was established and comprised of a drying step, the separation of microplastic particles > 1 mm, and a density separation for particles < 1 mm. The detection of the large microplastic particles (> 1 mm) was conducted with Attenuated Total Reflection - Fourier Transform infrared Spectroscopy (ATR-FTIR) , while Thermal Extraction Desorption - Gas Chromatography / Mass Spectrometry (TED-GC/MS) was applied for particles < 1 mm, gaining information on the type of polymer and mass fraction. Based on the established method, 14 environmental soil samples ? with different exposure of microplastics from agriculture, industrial sites, roads, and floods were investigated.
Due to the arbitrary microplastic particle distribution among the samples for large microplastics, it was reasoned that the found particles were unrepresentative. In contrast, microplastic particles < 1 mm were discovered in a high mass in soil samples exposed to plastic mulching or fertilization with sewage sludge or compost (0 – 115 mg/kg). On average, microplastic contents detected in soil samples taken from a construction site and an inner-city lake were higher (13 – 238 mg/kg). As expected, microplastic content in soil sampled in proximity to roads was more pronounced in the upper soil layers. In contrast, very remote sampling sites, expectably uncontaminated, did not lead to the detection of microplastic regarding to thermoanalytical detection method.
In a proof of concept experiment several in vivo and in vitro ecotoxicological tests were applied to evaluate the effect of microplastics (tyre abrasion, polystyrene containing hexabromocyclododecane) in natural soils. In summary, while no effects of the examined probes could be detected on higher levels of biological organization after exposures to earthworm E. andrei, significant changes in several oxidative stress related biomarkers were observed.
Deciphering microbiological influenced corrosion processes on steel with single cell-ICP-ToF-MS
(2022)
Microbiologically influenced corrosion (MIC) is a highly unpredictable process dictated by the environment, microorganisms, and the respective electron source. Interaction pathways between cells and the metal surface remain unclear. The development of this novel single cell-inductively coupled plasma-time of flight-mass spectrometry analytical method and a MIC-specific staining procedure facilitate the investigation of steel-MIC interactions. With this it is possible to analyze the multi-elemental fingerprint of individual cells. The detection method revealed elemental selectivity for the corrosive methanogenic archaeal strain Methanobacterium-affiliated IM1. The interface between material and environmental analysis thus receives special attention, e.g., when considering MIC on solid steel. Hence, the possible uptake of individual elements from different steel samples is investigated. Results showed the cells responded at a single-cell level to the different types of supplemented elements and displayed the abilities to interact with chromium, vanadium, titanium, cobalt, and molybdenum from solid metal surfaces. The information obtained will be used in the future to elucidate underlying mechanisms and develop possible material protection concepts, thus combining modern methods of analytical sciences with materials research.
References.
Safe food is a prerequisite for good human health, however currently almost one in ten people in the world fall ill after eating contaminated food. National food safety authorities need to be able to manage food safety risks along the entire food chain. The Official Controls Regulation (EU) 2017/625 was put in place to ensure that food and feed law stipulates the need for validated analytical methods. However, whilst method development for food control and proficiency testing are well established by European Union Reference Laboratories and National Reference Laboratories, validation of the measurements involved, certified reference materials and internationally recognised calibration and measurement capabilities are currently often (?) lacking. This may erode trust in the accuracy of the measurements.
This poster presents Food-MetNet, a coordinated preparatory initiative to establish the European Metrology Network for Safe and Sustainable Food, recently approved by the European Association of National Metrology Institutes (EURAMET). Food-MetNet aims to establish an ongoing dialogue between the metrology community, reference laboratories and regulatory bodies, in order to (i) identify stakeholders’ needs, (ii) develop a sustainable knowledge-sharing programme and web-based platform for stakeholders and (iii) develop roadmaps and a strategic research agenda. Improved access to more reliable and accurate food safety measurements will enable reference laboratories to more confidently and effectively compare their measurement results and support accreditation. This is particularly important where national food safety authorities need to assess potential new contaminants, novel food ingredients and newly emerging food risks, and new measurements methods may be required as well as input into new documentary standards. The activities for sustainable food intend to boost the activity within the "EU green deal framework" to reduce food waste and losses, and the development of standards and methods that allow for the reuse of food waste. The support to new business opportunities and innovation will allow increasing the market competitiveness of EU food industries and the valorisation of waste by reducing environmental impacts.
Compact NMR Spectroscopy in the field: A Versatile Tool for Automated Continuous-Flow Production
(2022)
Chemical companies must find new paths to successfully survive in a changing environment. The potential of digital technologies belongs to these. Flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds.
Therefore, fully automated “chemical” process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. A commercially available benchtop NMR spectrometer was integrated to the full requirements of an automated chemical production environment such as, e.g., explosion safety, field communication, and robust evaluation of sensor data. It was thereof used for direct loop advanced process control and real-time optimization of the process. Field studies in modular and conventional production plant setups show promising results gaining process knowledge for further optimization. NMR appeared as preeminent online analytical method and allow using a modular data analysis tool, which even served as reliable reference method for further PAT applications (e.g. NIR spectroscopy). In the future, such fully integrated and intelligently interconnecting “smart” systems and processes can speed up the high-quality production of specialty chemicals and pharmaceuticals.
Compact NMR Spectroscopy in the field: A Versatile PAT Tool for Production of Specialty Chemicals
(2022)
Companies of chemical industry find themselves more often in a rapidly changing environment, e.g., due to variability of raw material quality or energy costs and efficiency. Process optimization and new process concepts become more and more important. For example, flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds like exothermic reactions with high heat dissipation.
Therefore, fully automated “chemical” process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. A commercially available benchtop NMR spectrometer was integrated to the full requirements of an automated chemical production environment such as explosion safety, field communication, and robust evaluation of sensor data. Field studies in modular and conventional production plant setups show promising results gaining process knowledge for further optimization. NMR appeared as preeminent online analytical method and allow using a modular data analysis approach, which can even serve as reliable reference method for further calibration-dependent PAT applications (e.g., NIR spectroscopy). Based on experiences from these field studies an improved analyzer enclosure setup was developed and built, including the option of a secondary method besides NMR spectroscopy. Integrated control systems allow for a flexible implementation based on the available automation infrastructure at the chemical plant or pilot plant setup. In the future, fully integrated and intelligently interconnecting “smart” PAT systems and processes have the potential speed up the setup of production equipment for chemicals and pharmaceuticals and therefore help to reduce the time-to-market.
Compact NMR Spectroscopy in the field: A Versatile PAT Tool for Production of Specialty Chemicals
(2022)
Chemical companies must find new paths to successfully survive in a changing environment, especially by utilizing the potential of digital technologies. Flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce time to market for new products.
Therefore, fully automated process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. A commercially available benchtop NMR spectrometer was integrated to the full requirements of chemical production environment such as explosion safety, field communication, and robust evaluation of sensor data. It was used for direct loop advanced process control and real-time optimization of the process. Field studies in modular and conventional production plants show promising results gaining process knowledge. NMR appeared as preeminent online analytical method and allow using a modular data analysis tool, which even served as reliable reference method for further PAT applications (e.g. NIR spectroscopy). In the future, fully integrated and interconnecting “smart” systems and processes can speed up the high-quality production of specialty chemicals and pharmaceuticals.
Compact NMR Spectroscopy in the field: A Versatile PAT Tool for Production of Specialty Chemicals
(2022)
Chemical companies must find new paths to successfully survive in a changing environment, especially by utilizing the potential of digital technologies. Flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce time to market for new products.
Therefore, fully automated process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. A commercially available benchtop NMR spectrometer was integrated to the full requirements of chemical production environment such as explosion safety, field communication, and robust evaluation of sensor data. It was used for direct loop advanced process control and real-time optimization of the process. Field studies in modular and conventional production plants show promising results gaining process knowledge. NMR appeared as preeminent online analytical method and allow using a modular data analysis tool, which even served as reliable reference method for further PAT applications (e.g. NIR spectroscopy). In the future, fully integrated and interconnecting “smart” systems and processes can speed up the high-quality production of specialty chemicals and pharmaceuticals.
Mycotoxins (toxic compounds formed by fungi) in food and feed have caused problems for mankind since the beginning of time. The group of ergot alkaloids plays a special role in human history. Several tens of thousands of deaths during the middle ages caused by to ergotism (the disease caused by continuous intake of ergot alkaloid contaminated food) underscore the importance of reliable analytical methods to ensure food safety.
More than 50 compounds belong to the group of ergot alkaloids. The 12 most found structures – the major ergot alkaloids – are typically measured, when it comes to ergot alkaloid quantification. High performance liquid chromatography (HPLC) with a fluorescence detector (FLD) is typically used to quantify the ergot alkaloid content. The main disadvantage of this method are the high costs for calibration standards (12 different calibration substances are required). But also, the time and effort required for the analysis of 12 peaks and overlapping signals that occur in complex food samples such as bread. As all ergot alkaloids share the ergoline structure and just differ in the substituents attached to this backbone, measurement of all ergot alkaloids in one sum parameter presents a time and cost saving alternative. The most important step for the development of such a sum parameter method is the reaction used to transfer all ergot alkaloids to one uniform structure. Two promising reactions, the acidic esterification to lysergic acid methyl ester and hydrazinolysis to lysergic acid hydrazide, were examined for possible use in a routine analysis method. In addition to yield and reaction rate, factors such as handling of the reaction and the possibility of parallel sample workup play a role.
11 laser printers from 5 manufacturers were purchased in 2017 and tested for their UFP emissions. Size resolved sampling of the emitted particles was done with a 13 stage (30 nm to 10 µm) low pressure cascade impactor. The sampled particles were analysed for their chemical composition by thermal extraction (vaporization at 290°C) followed by GC-MS analysis. High boiling cyclic siloxanes (D10 to D16) were detected as constituents of UFP from laser printers. In comparison to measurements in 2008, aliphatic long-chain alkanes (C22 to C34) were detected additionally as chemical constituents of UFP from most of the tested printers and their amounts were higher than for cyclic siloxanes. Printers of one manufacturer showed very low UPF emissions compared to the other manufacturers.
The isotopic analysis of lithium is also relevant to the study of geological phenomena.1 In this work we propose improvements to the method for the isotopic analysis of lithium using a high-resolution continuum source atomic absorption spectrometer (HR-CS-AAS) coupled to a double echelle modular spectrometer (DEMON). 2 This tool for isotopic ratio determination is based on monitoring the isotopic components of lithium by their spin-orbit coupling and its isotopic shift of about 15 pm for the 22P←2 2S electronic transition around 670.788 nm. The data analysis was carried out by using a decision-tree-based ensemble machine learning (ML) algorithm. For the training of the algorithm (XGBoost), a set of samples with 6Li isotope amount fractions ranging from 0.06 to 0.99 mol-1 was used. Subsequently, the procedure was validated of a set of stock chemicals (Li2CO3, LiNO3, LiCl and LiOH) and a BAM candidate reference material, the cathode material LiNi1/3Mn1/3Co1/3O2 (NMC111). Finally, the ML model was applied to the set of geological samples, previously digested, for the determination of their isotope ratio. The optical resolution was improved from 140,000 to 790,000 to better deconvolution the lithium isotopic components in the atomic spectrum. And the method was compared with multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The results are metrologically comparable.
Natural and synthetic estrogens are key endocrine-disrupting chemicals. Despite occurring at ultra-trace levels (below ng L-1), it is believed that they are contributing to an increase in feminized fish and other endocrine disruptive effects, and hence, their inclusion in the Watch list was not unexpected. One of the main sources ofestrogens to surface waters is wastewater effluent. Once in surface waters, they can partition into different compartments, i.e., water and suspended particulate matter. For this reason, there is an urgent need for a methodology to monitor estrogen levels below the environmental quality standards (EQS) set by the Water Framework Directive requirements.
In this study, a precise and accurate gas chromatography-mass spectrometry method (GC-MS/MS) for the analysis of estrone (E1), 17β-estradiol (17β-E2), 17α-estradiol (17α- E2), 17-alpha-ethinylestradiol (EE2), and estriol (E3) in whole water samples with ng L-1 limit of quantification (LOQ) was developed and validated in accordance with CEN/TS 16800:2020 guidelines.
Per- and polyfluorinated alkyl substances (PFASs) are a substance class of over 4730 individual compounds. Several PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their different chemical and physical properties as well as the high number of target substances. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate a realistic PFAS pollution level.
PFAS sum parameters compromise the proportion of organically bound fluorine that can either be extracted (EOF) or adsorbed to activated carbon (AOF). For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) is a sensitive and highly selective tool for indirect fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L.
Here, we describe a fast and simple extraction method for the determination of the EOF using HR-CS-GFMAS in soil samples. Common approaches for the EOF determination use solid phase extraction (SPE). To omit the bias of this time consuming and expensive step we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol. Comparison of the method with and without an SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. In the next step, the applicability of our method was tested for other solid matrices. In view of steadily increasing numbers of PFASs, our method will make an important contribution in assessing the pollution situation as well as support policy makers in deriving exposure limits for PFASs in the future.