Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Vortrag (11)
- Zeitschriftenartikel (7)
- Posterpräsentation (2)
- Sonstiges (1)
Schlagworte
- Metrology (21) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (11)
This document constitutes the Strategic Research Agenda (SRA) for the European Metrology Network for Mathematics and Statistics in Metrology (EMN Mathmet). The EMN Mathmet is an alliance of European National Metrology Institutes (NMIs), Designated Institutes (DIs) and an EMN Partner that aims to strengthen research and cooperation in the field. The SRA has been developed within a European project (EMPIR 18NET05 MATHMET) to promote and support the network. The SRA was developed based on a consultation process with stakeholders and the strategies of individual NMIs and DIs, and in alignment with the EURAMET 2030 strategy.
As a key result, the SRA defines a long-term research goal: the EMN Mathmet will coordinate research to strengthen the trust in algorithms, software tools and data to underpin digital transformation. For this purpose, new emerging research topics where algorithms, software tools and data play a significant role were identified: (i) Artificial Intelligence and Machine Learning, and (ii) Computational Modelling and Virtual Metrology. The foundation for the development of these new topics is given by the traditional focus on (iii) Data Analysis and Uncertainty Evaluation. The SRA characterises the future needs and challenges in the field of mathematics and statistics in metrology and provides an outline of how the EMN Mathmet can meet these new emerging requirements.
Ergot alkaloids form a toxicologically relevant group of mould toxins (mycotoxins) that are among the most common contaminants of food and animal feed worldwide. Reliable controls are essential to minimise health risks and economic damage. Due to their toxicological relevance, EU limit values for 12 priority ergot alkaloids have been introduced for the first time in 2022 and range from 500 µg/kg in rye milling products down to 20 ug/kg Processed cereal-based foods for infants and young children[1]. High-performance liquid chromatography - mass spectrometry is used to quantify low concentrations of ergots in food, however the European standard analytical procedure cannot be applied due to the lack of isotopically labelled reference standards.
The complex structure of the ergot alkaloids makes a total synthesis extremely challenging, expensive and time-consuming. Therefore, we are focusing on different semi-preparative methods (electrochemistry, organic synthesis, heterogeneous catalysis) to specifically N-demethylate the C8 carbon atom of the lysergic acid moiety. The norergot alkaloid formed is then isotopically labelled using an electrophilic methyl source, i.e. iodomethane or dimethyl sulphate to obtain the specific isotopic labelled ergot alkaloid. Initial experiments have shown that N-demethylation of the ergot alkaloid ergotamine is possible by both electrochemical and wet-chemical organic synthesis. The next step is to adapt the previously determined reaction conditions to enable the synthesis of norergotamine on a mg scale.
Demonstrating competency and equivalence for the measurement capacity of contaminants and nutrients in primary foodstuffs is a priority of the OAWG 10-year strategy for Track A core comparisons. Such measurements have posed significant challenges for reference material producers and calibration service providers. This key comparison (KC), under the topic of “non- polar analyte in high carbohydrate food matrix: trans-Zearalenone (trans-ZEN) in maize powder” , was a sector of the model system selected to align with this class within the OAWG strategy. Evidence of successful participation in formal, relevant international comparisons is needed to demonstrate the Calibration and Measurement Capabilities (CMCs) of national metrology institutes (NMIs) and designated institutes (DIs).
17 NMIs and DIs participated in the Track A KC CCQM- 168 “non-polar analyte in high carbohydrate food matrix: trans-ZEN in maize powder” . Participants were requested to evaluate the mass fraction (μg/kg) of trans-ZEN in maize powder material. Methods like liquid-liquid extraction and SPE were applied in the pre-treatment, and HPLC-MS/MS and HPLC-FLD were used for detection by the participants. The mass fractions for trans-ZEN were in the range of (91.8 to 169) μg/kg with standard uncertainties of (1.5 to 24.7) μg/kg, and corresponding relative standard uncertainties from 1.5% to 14.6%. Two labs, INTI and BAM were excluded from the KCRV evaluation. INTI result was identified as an outlier and confirmed their method had insufficient specificity. For BAM the calibration approach they used does not meet the CIPM traceability requirements. The other 15 labs included in the calculation of the consensus KCRV all agreed within their standard uncertainties. Hierarchical Bayes was used as estimators in calculating KCRV and standard uncertainty.
Successful participation in CCQM-K168 demonstrates the measurement capabilities in determining mass fraction of organic compounds, with molecular mass of 100 g/mol to 500 g/mol, having low polarity pKow < -2, in mass fraction range from 1 μg/kg to 1000 μg/kg in a high carbohydrate food matrix.
This presentation provides a short introduction to the Commission on Isotopic Abundances and Atomic Weights (CIAAW). It describes the role of the Commission and provides an insight into its work and the corresponding principal tasks. Finally, it provides the reader with the latest achievements and with the most recent publications.
IRWG strategy update
(2023)
Climate change and related energy policies, exacerbated by unforeseen geopolitical developments, pose new challenges for gas analytics, such as the use of hydrogen, hydrogen-containing alternative gaseous fuels (NH3, etc.), the use of alternative methane-based energy gases (LNG, LPG, etc.) or decarbonisation via CCSU. In all topics, the quality, i.e. the actual chemical composition of the gases, naturally plays a decisive role. BAM is meeting this strategic importance with the further development of hydrogen analytics and is continuing to develop the methods used in order to support the German economy and research landscape with traceability, reference materials and analytical procedures as quickly as possible.
Mass spectrometry plays an important role for trace analysis in hydrogen matrix. The presentation shows first experimental results from the application of PTR-TOF-MS (Proton Transfer Reaction Time-of-Flight Mass Spectrometry).
Safe food is a prerequisite for good human health, however currently almost one in ten people in the world fall ill after eating contaminated food. National food safety authorities need to be able to manage food safety risks along the entire food chain. The Official Controls Regulation (EU) 2017/625 was put in place to ensure that food and feed law stipulates the need for validated analytical methods. However, whilst method development for food control and proficiency testing are well established by European Union Reference Laboratories and National Reference Laboratories, validation of the measurements involved, certified reference materials and internationally recognised calibration and measurement capabilities are currently often (?) lacking. This may erode trust in the accuracy of the measurements.
This poster presents Food-MetNet, a coordinated preparatory initiative to establish the European Metrology Network for Safe and Sustainable Food, recently approved by the European Association of National Metrology Institutes (EURAMET). Food-MetNet aims to establish an ongoing dialogue between the metrology community, reference laboratories and regulatory bodies, in order to (i) identify stakeholders’ needs, (ii) develop a sustainable knowledge-sharing programme and web-based platform for stakeholders and (iii) develop roadmaps and a strategic research agenda. Improved access to more reliable and accurate food safety measurements will enable reference laboratories to more confidently and effectively compare their measurement results and support accreditation. This is particularly important where national food safety authorities need to assess potential new contaminants, novel food ingredients and newly emerging food risks, and new measurements methods may be required as well as input into new documentary standards. The activities for sustainable food intend to boost the activity within the "EU green deal framework" to reduce food waste and losses, and the development of standards and methods that allow for the reuse of food waste. The support to new business opportunities and innovation will allow increasing the market competitiveness of EU food industries and the valorisation of waste by reducing environmental impacts.
Introduction: The influence of copper, iron and zinc concentrations on the formation of ß-amyloid plaques and neurofibrillary tangles in Alzheimer’s disease (AD) is widely discussed in the community. The results from human and animal studies so far are mixed with some studies showing a correlation and others not. From a number of studies, it is known that disease state and isotopic composition of essential elements can be coupled.
Aim: The aim of the study was to identify changes in element content and isotopic composition in two transgenic mouse models used in AD research compared to their genetic WT relatives and to establish whether element content and isotopic signature between different laboratories is comparable.
Methods: ß-amyloid (5xFAD) and tau overexpressing (L66) mice together with their matching wild-types were bred at dedicated facilities in accordance with the European Communities Council Directive (63/2010/EU). Serum and brain were sampled after sacrifice and the samples distributed among the participants of the study. The tissues were acid digested for total element determination and high-precision isotope ratio determination. Element content was determined by either sector-field or quadrupole-based inductively coupled plasma mass spectrometry (ICPMS). For the determination of isotope ratios multi-collector ICPMS was used.
Results: Total copper content was significantly higher for L66 and their matched WT compared to 5xFAD and WT. Brains of L66 mice contained more Fe in brain than their WT, Zn and Cu were not significantly different between L66 and WT. Whereas 5xFAD mice had a slightly lower Cu and slightly higher Zn concentration in brain compared to WT. The isotopic signature in brain of L66 mice for Fe was different from their controls, whereas Zn isotope ratios were influenced in 5xFAD mice compared to their WT. The Cu isotopic ratio did not seem to be influenced in either strain. In serum, the shifts were less pronounced.
Conclusion: Even though neither Tau-protein nor amyloid precursor protein are known to be metal-dependent / -containing proteins, the overexpression of both influences the Fe, Cu and Zn metabolism in brain and to some extent also in serum as can be seen not only using total element determination but probably more clearly studying the isotopic signature of Fe, Cu and Zn.
The CCQM-K148.a comparison was coordinated by the BIPM on behalf of the CCQM Organic Analysis Working Group for NMIs and DIs which provide measurement services in organic analysis under the CIPM MRA. It was undertaken as a "Track A" comparison within the OAWG strategic plan. CCQM-K148.a demonstrates capabilities for assigning the mass fraction content of a solid organic compound having moderate molecular complexity, where the compound has a molar mass in the range (75 - 500) g/mol and is non-polar (pKow < −2), when present as the primary organic component in a neat organic solid and where the mass fraction content of the primary component in the material is in excess of 950 mg/g.
Participants were required to report the mass fraction of Bisphenol A present in one supplied unit of the comparison material. Participants using a mass balance method for the assignment were also required to report their assignments of the impurity components present in the material. Methods used by the seventeen participating NMIs or DIs were predominantly based on either stand-alone mass balance (summation of impurities) or qNMR approaches, or the combination of data obtained using both methods. The results obtained using thermal methods based on freezing-point depression methods were also reported by a limited number of participants. There was excellent agreement between assignments obtained using all three approaches to assign the BPA content.
The assignment of the values for the mass fraction content of BPA consistent with the KCRV was achieved by most of the comparison participants with an associated relative standard uncertainty in the assigned value in the range (0.1 - 0.5)%.