Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (42)
- Vortrag (25)
- Posterpräsentation (22)
- Sonstiges (4)
- Beitrag zu einem Tagungsband (2)
- Dissertation (1)
- Forschungsdatensatz (1)
Sprache
- Englisch (82)
- Deutsch (14)
- Mehrsprachig (1)
Schlagworte
- Immunoassay (10)
- ICP-MS (8)
- Amperometry (7)
- ELISA (6)
- Antikörper (5)
- Estrogens (5)
- LA-ICP-MS (5)
- LC-MS/MS (5)
- Laser ablation (5)
- Nanoparticle (5)
- Cell (4)
- Mass Spectrometry (4)
- Transformationsprodukte (4)
- Warfarin (4)
- Amoxicillin (3)
- BFR (3)
- Comparability (3)
- Cyclic voltammetry (3)
- Diclofenac (3)
- Effect based Method (3)
- GC-MS (3)
- MS based method (3)
- Mass spectrometry (3)
- Metabolomics (3)
- Metrology (3)
- Nontarget analysis (3)
- Ochratoxin A (3)
- Reliable measurements (3)
- Umweltsimulation (3)
- Wastewater (3)
- XRF (3)
- Abwasser (2)
- Accurate mass (2)
- Benz[a]anthracene (BaA) (2)
- Benzo[a]pyrene (BaP) (2)
- Biosensor (2)
- Cancer (2)
- Combustion Ion Chromatography (2)
- Compound annotation (2)
- E. coli (2)
- Electrochemistry (2)
- Electrospray ionization (2)
- Environmental simulation (2)
- Fertilizer (2)
- Finow Canal (2)
- Food analysis (2)
- Gas chromatography (GC) (2)
- Heart failure (2)
- ILC (2)
- Imaging (2)
- Isotope dilution (2)
- Isotope dilution (ID) (2)
- Legacy pollution (2)
- Liquid chromatography (LC) (2)
- Magnetic beads (2)
- Mass Spectroscopy (2)
- Mass spectrometry (MS) (2)
- Metformin (2)
- Method development (2)
- Methylmercury (2)
- Mobile phase (2)
- Multicellular spheroid (2)
- Nickel (2)
- PBFSM (2)
- PEG (2)
- Peptide analysis (2)
- Per- and Polyfluoroalkyl substances (PFAS) (2)
- Pollutants (2)
- Polycyclic aromatic hydrocarbon (PAH) (2)
- Polyethylene glycole (2)
- Polymer (2)
- Polypropylen (2)
- Polystyrol (2)
- Probenvorbereitung (2)
- Purity assessment (2)
- R package (2)
- RFA (2)
- Retrospective analysis (2)
- SARS-CoV-2 (2)
- Schadstoffaustrag (2)
- Schadstoffe (2)
- Sewage sludge (2)
- Umweltverhalten (2)
- Validation (2)
- WFD (2)
- Wasser (2)
- Whole water samples (2)
- 6xHis (1)
- ACE2-Rezeptor (1)
- ATCUN (1)
- Adsorption (1)
- Affinity chromatography (1)
- Affinitätschromatographie (1)
- Aluminum oxide (1)
- Amino acid analysis (1)
- Analytical Sciences (1)
- Analytical methods (1)
- Antibiotics (1)
- Antibodies (1)
- Antibody (1)
- Antibody Quantification (1)
- Antibody quantification (1)
- Arzneimittel (1)
- Automation (1)
- BPA (1)
- Bacterial lysates (1)
- Bakterien (1)
- Basic solvent (1)
- Bead injection spectroscopy (1)
- Bewitterung (1)
- Biomarker (1)
- Biomarkers (1)
- Bioseparation (1)
- Bisphenol A (1)
- Bisphenol-A (1)
- Bisphenols (1)
- Bivalves (1)
- Blood-brain barrier (1)
- CCQM (1)
- CCQM key comparison (1)
- COVID-19 (1)
- Cardiolipins (1)
- Carrier (1)
- Chemical coverage (1)
- Chromatography (1)
- Chronic kidney disease (1)
- Climate Changes (1)
- Clinical samples (1)
- Cocaine (1)
- Copper (1)
- Corona (1)
- Corundum (1)
- Cyclization (1)
- Cylic Voltammetry (1)
- Cytoplasm (1)
- D-glucose (1)
- DCF (1)
- Data Analyses (1)
- Degradation (1)
- Diastolic dysfunction (1)
- Downstream processing (1)
- Dynamische Lichtstreuung (1)
- EDC (1)
- EDTAD (1)
- EPR spectroscopy (1)
- EQS (1)
- EU-WFD (1)
- Einzelzellanalyse (1)
- Electrochemical (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Environment (1)
- Environmental analysis (1)
- Enzyme Immobilisation (1)
- Ergot alkaloids (1)
- Escherichia coli (1)
- Ethylenediaminetetraacetic acid (1)
- Expression (1)
- FTIR spectroscopy (1)
- Fatty acid metabolism (1)
- Fenton (1)
- Festphasenextraktion (1)
- Fingerprint (1)
- Flammschutzmittel (1)
- Flux Analysis (1)
- Folic acid (1)
- Fow injection analysis (1)
- Glucose (1)
- Größenausschlusschromatographie (1)
- HPLC (1)
- HPLC-MS (1)
- HPLC–MS (1)
- Halomonas elongata (1)
- Hapten Immunoassay (1)
- HexaHis-Tag (1)
- High pH (1)
- High-resolution mass spectrometry (1)
- His6 (1)
- His8 (1)
- Hormone (1)
- Human serum (1)
- Hydrolysis (1)
- Hydrolysis products (1)
- Hypothalamus (1)
- ICP-ToF-MS (1)
- IMAC purification (1)
- Immunocapture (1)
- Interlaboratory comparison (1)
- Interlaboratory key comparison (1)
- Iron disorders (1)
- Isotopologue Distribution (1)
- JNP POLMO (1)
- Kläranlage (1)
- Konjugate (1)
- L-alanine (1)
- LC-MS/MS peptide quantification (1)
- LFIA (1)
- Lab-on-chip (1)
- Lactate (1)
- Laser Ablation/Imaging (1)
- Lebensmittel (1)
- Linear dynamic range (1)
- Lipidomic profile (1)
- Lipidomics (1)
- Lipids (1)
- Liquid chromatography (1)
- Liquid chromatography-mass spectrometry (1)
- Liver X receptor (1)
- MALDI-TOF-MS (1)
- MALDI-ToF-MS (1)
- MOF (1)
- MST (1)
- Magnetic nanocatalyst (1)
- Magnetpartikel (1)
- Maillard reaction (1)
- Mass Isotopomer Distribution (1)
- Massenspektrometrie (1)
- Matrixeffekte (1)
- Melanoidin (1)
- Melanoidine (1)
- Mercury speciation (1)
- Meta-study (1)
- Metabolic Flux (1)
- Metabolic stress (1)
- Metabolites (1)
- Metalloprotein (1)
- Microdialysis (1)
- Microfluidic (1)
- Microparticles (1)
- Migration (1)
- Molecular imprinted polymers (1)
- Monoamine oxidase B (1)
- Mycotoxin (1)
- Mycotoxins (1)
- Mykotoxine (1)
- N-capsid (1)
- NMR spectroscopy (1)
- NSO-Heterozyklen (1)
- Nanobody (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Naphthalene (Nap) (1)
- Nickel chelate (1)
- Non-target (1)
- Non-targeted analysis (1)
- Nontargeted approach (1)
- Nuclear receptor (1)
- Oberflächenwasser (1)
- Organic calibration solution (1)
- Organic contaminants (1)
- PEGomics (1)
- PFAS (1)
- PFAS TOP Assay soil contamination (1)
- PP (1)
- PS (1)
- Parkinsons's disease (1)
- Peptide (1)
- Peptide losses (1)
- Periplasma (1)
- Pharmaceutical Drugs (1)
- Pharmazeutika (1)
- Photocatalysis (1)
- Photodegradation (1)
- Photodynamische Inaktivierung (1)
- Photokatalyse (1)
- Photooxidation (1)
- Photosensibilisator (1)
- Phthalocyanin (1)
- Polishing (1)
- Pollution (1)
- Porphyrin (1)
- Prussian blue (1)
- Purity (1)
- QC (1)
- Quality control (1)
- RBD (1)
- Recombinant protein (1)
- Recovery (1)
- Reference material (1)
- Rekombinante Antikörper (1)
- Ringversuch (1)
- Round robin exercise (1)
- Round robin test (1)
- SDS-PAGE (1)
- Sample treatment (1)
- Sapphire (1)
- Screen-printed electrodes (1)
- Sensing (1)
- Sewage treatment plant (1)
- Silanization (1)
- Silbernanopartikel (1)
- Smartphone (1)
- Software (1)
- Solid-phase extraction (1)
- Sonochemical synthesis (1)
- Speroid (1)
- Spheroid (1)
- Spike-Protein (1)
- Stability (1)
- Standardization (1)
- Surface water (1)
- TMB (1)
- Terbutryne (1)
- Therapeutic Drug Monitoring (1)
- Toxikologie (1)
- Transcriptomic (1)
- Transformation products (1)
- Transformations products (1)
- Triazine herbicide (1)
- Tumor metabolism (1)
- UV Bestrahlung (1)
- Validation trial (1)
- Validierung (1)
- Vhh (1)
- Vibrational Sum-Frequency Generation Spectroscopy (1)
- Virus (1)
- Wasserproben (1)
- Water analysis (1)
- Weathering (1)
- Yerba mate tea (1)
- Zebrafisch (1)
- Zyklisierung (1)
- β-lactam (1)
Organisationseinheit der BAM
- 1.8 Umweltanalytik (97) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (25)
Analytical Sciences has developed from Ostwald’s “unentbehrlichen Dienstmagd” to a chemical discipline at the core of many of today’s fundamental and applied scientific problems and innovations. An atomic or molecular understanding of basic processes in chemistry, soft matter physics, materials and life science is enabled only through new analytical methods and instrumentation. Similar observations can be found for pressing sociopolitical conflicts of the future: A rational discussion of global climate change or new energy sources is only possible with reliable analytical results. Progress in Analytical Sciences is only possible if the underlying interdisciplinary character is acknowledged and valued. The talk will illustrate the scope of modern Analytical Science through examples from process analysis relevant to modern process intensification and industry 4.0 to bioanalysis and the use of synchrotron radiation to elucidate fundamental reactions materials.
The investigation of metabolic fluxes and metabolite distributions within cells by means of tracer molecules is a valuable tool to unravel the complexity of biological systems. Technological advances in mass spectrometry (MS) technology such as atmospheric pressure chemical ionization (APCI) coupled with high resolution (HR), not only allows for highly sensitive analyses but also broadens the usefulness of tracer‐based experiments, as interesting signals can be annotated de novo when not yet present in a compound library. However, several effects in the APCI ion source, i.e., fragmentation and rearrangement, lead to superimposed mass isotopologue distributions (MID) within the mass spectra, which need to be corrected during data evaluation as they will impair enrichment calculation otherwise. Here, we present and evaluate a novel software tool to automatically perform such corrections. We discuss the different effects, explain the implemented
algorithm, and show its application on several experimental datasets. This adjustable tool is available as an R package from CRAN.
Natural and synthetic estrogens are key endocrine-disrupting chemicals. Despite occurring at ultra-trace levels (below ng L-1), it is believed that they are contributing to an increase in feminized fish and other endocrine disruptive effects, and hence, their inclusion in the Watch list was not unexpected. One of the main sources ofestrogens to surface waters is wastewater effluent. Once in surface waters, they can partition into different compartments, i.e., water and suspended particulate matter. For this reason, there is an urgent need for a methodology to monitor estrogen levels below the environmental quality standards (EQS) set by the Water Framework Directive requirements.
In this study, a precise and accurate gas chromatography-mass spectrometry method (GC-MS/MS) for the analysis of estrone (E1), 17β-estradiol (17β-E2), 17α-estradiol (17α- E2), 17-alpha-ethinylestradiol (EE2), and estriol (E3) in whole water samples with ng L-1 limit of quantification (LOQ) was developed and validated in accordance with CEN/TS 16800:2020 guidelines.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve. The project EDC-WFD “Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive” aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17aE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods - Mass Spectrometry based method and effect-based methods (EBM) - and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four EBM will be deeply investigated in order to improve their rationale use and their support in water quality assessment.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve. The project EDC-WFD “Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive” aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17aE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods - Mass Spectrometry based method and effect-based methods (EBM) - and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four EBM will be deeply investigated in order to improve their rationale use and their support in water quality assessment.
Increasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a series of spiked water samples yielded results with low to moderate intra- and inter-assay variations and in good agreement with LC–MS/MS reference analysis. The assay principle can be transferred to other, e.g., microfluidic, formats, as well as applied to other analytes and may replace ELISA as the standard immunochemical method.
Regardless of its ban in agricultural use, the triazine derivative terbutryn is still used as a biocide against biofouling in building materials, such as façade colors and roof tiles. From there, it is washed off and may contaminate soil and surface waters, where it shows ecotoxicological behavior. For understanding of these leaching processes, analytical methods that can detect terbutryn in traces are necessary. In contrast to separation methods (Gas (GC) or liquid chromatography (LC)) coupled to mass spectrometry (MS), enzyme immunoassays (EIAs) have proven to be adequate tools for environmental monitoring. Compared to GC-or LC-MS, they are cheap, require only limited time and experimental expertise and enable high throughput. For quantification of terbutryn, EIAs have been established, with a limit of detection (LOD) of 50 ng L-1. For leaching experiments however, a lower LOD would be advantageous.
For detection of terbutryn we developed a direct competitive ELISA based on a monoclonal antibody: Terbutryn and an enzyme-terbutryn conjugate (“tracer”) compete for the binding sites of the immobilized antibody. The bound tracer converts a colourless substrate into a blue-coloured product, which can be detected via spectrophotometry. For quantification of terbutryn, a sigmoidal calibration curve is used. For establishing of the EIA, a new tracer based on a terbutryn surrogate (“hapten”) was synthesized. After optimization of the experimental conditions, the immunoassay exhibited a more than ten-fold increased sensitivity (LOD: 3 ng L-1), high stability against sample compounds (Ca2+, NaCl) and lower cross-reactivities against structurally related compounds, than reported before. Analysis of spiked samples was possible with high precision (inter-assay CV: < 10 %) and accuracy (recoveries from spiked samples: 89 % ± 10%). We therefore propose it as quick and reliable method for leaching studies of terbutryn out of building materials.
Lipid droplets, the dynamic organelles that store Triglycerides (TG) and cholesterol esters (CE), are highly accumulated in colon cancer cells. This work studies the TG and CE subspecies profile in colon carcinoma cell lines, SW480 derived from primary tumor, and SW620 derived from a metastasis of the same tumor. It was previously reported that the total TG and CE content is dramatically higher in SW620 cells; however, TG and CE subspecies profile has not been investigated in detail. The work presented here confirms that the total TG and CE Content is significantly higher in the SW620 cells. Moreover, the fatty acid (FA) composition of TG is significantly altered in the SW620 cells, with significant decrease in the abundance of saturated triglycerides. This resulted in a significantly decreased TG saturation index in the SW620 cells. The saturation index of CE was also significantly decreased in the SW620 cells.
Hepcidin-25 has attracted much attention ever since its discovery in 2001. It is widely recognized that this peptide hormone plays a major role in the regulation of iron levels in mammals and can reveal important clinical information about several iron-related disorders. However, the development of a reliable assay to quantify hepcidin proved to be problematic and serum hepcidin-25 concentrations determined by various assays differ substantially. Challenges arise in the MS analysis of hepcidin due to the “sticky” character of the peptide and the lack of suitable standards.
With the aim to tackle the current difficulties in hepcidin quantification and improve the status of this promising biomarker in the clinical field, we developed a rapid and robust analytical strategy for the quantification of hepcidin-25 in human samples based on HPLC-MS/MS (QqQ) as a reference method candidate to be implemented in routine laboratories. The novelty of the method is the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces. Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions where the use of acidic mobile phases was compared with a novel approach involving solvents at high pH containing 0.1% of ammonia. Both methods were carefully validated and applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with very good correlation of the results.
The antimicrobial photodynamic approach has been demonstrated as an efficient and sustainable process for the eradication of microbial pathogens. In this work, silica-coated Magnetite nanoparticles (NPs) were used as carriers of glycosylated porphyrins and phthalocyanines. Their subsequent cationization
resulted in the production of stable antimicrobial photosensitizing materials, effective against E. coli. Suspensions of the photocatalysts in water present bimodal size distributions formed by big clusters and small NPs with hydrodynamic diameters between 8 and 38 nm. The presence of small NPs in the suspensions is related to an effective photodynamic inactivation (PDI) of E. coli cells. Glycosylation of the PS showed a positive effect on the PDI performance, which could be related to a higher accumulation of the photocatalyst over the bacterial cell membrane. In addition, these biocidal agents proved to be photostable and their photoactive performance decreased only between 23% and 28% upon 5 PDI cycles, mostly because of the loss of material between cycles, which makes them promising materials for water disinfection purposes.