Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (13)
- Vortrag (6)
- Posterpräsentation (2)
Schlagworte
- GDMS (4)
- Calibration (2)
- GD-OES (2)
- Halogene (2)
- Lithium (2)
- AAS (1)
- AFM (1)
- Algorithms (1)
- Aluminium (1)
- Atomic Absorption Spectrometry (1)
- Atomic Force Microscopy (1)
- Atomic absorption spectrometry (1)
- CCQM (1)
- CdSe/ZnS quantum Dots (1)
- Cell (1)
- Cellular uptake (1)
- Classical primary measurement method (CPM) (1)
- DC-Arc (1)
- Depht profiling (1)
- Direct metal assay (1)
- Fast flow GD (1)
- Fast single pulse response (1)
- GD-MS (1)
- Glow Discharge (1)
- Graphit (1)
- HT22 (1)
- HeLa (1)
- High purity (1)
- High purity material (1)
- High-purity elements (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hot-pressing (1)
- Human serum (1)
- Hydrogen (1)
- ICP-MS (1)
- Impurity assessment (1)
- Inorganic chemical analysis (1)
- Isotope (1)
- Isotope dilution (1)
- LA-ICP-SFMS (1)
- Laser ablation (1)
- Li-ion battery (1)
- Machine learning (1)
- Magnetically stabilized (1)
- Material Science (1)
- Matrix independent calibration (1)
- Metrology (1)
- Metrology in chemistry (1)
- Nanoparticle (1)
- Nichtmetalle (1)
- Nickel (1)
- Niobcarbid (1)
- Non metals (1)
- Non-metal analysis (1)
- Optical emission spectroscopy (1)
- Plasma (1)
- Plasmaspectrochemistry (1)
- Primary difference measurement method (PDM) (1)
- Primary standard (1)
- Primary transfer standards (PTSs) (1)
- Primäre Kalibriersubstanzen (1)
- Pulsed-GD-SFMS (1)
- Purity assessment (1)
- Quantitative bioimaging (1)
- Reference material (1)
- Reference materials (1)
- Referenzmaterialien (1)
- Reinstmetalle (1)
- Reinststoffe (1)
- SI Traceability (1)
- SI-traceability (1)
- Single cell (1)
- Spectroscopy (1)
- Sputtering (1)
- Titanium hydride (1)
- Traceability (1)
- Two-phase system (1)
- Vanadiumcarbid (1)
- Wolframcarbid (1)
- Zertifizierung (1)
- Zn (1)
- battery aging mechanism (1)
- current collector corrosion (1)
- depth profiles (1)
- pL-droplets (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (21)
- 1.6 Anorganische Referenzmaterialien (18)
- 1.1 Anorganische Spurenanalytik (6)
- S Qualitätsinfrastruktur (5)
- S.1 Qualität im Prüfwesen (5)
- 1.3 Instrumentelle Analytik (2)
- 1.4 Prozessanalytik (2)
- 9 Komponentensicherheit (2)
- 9.5 Tribologie und Verschleißschutz (2)
- P Präsident (2)
Eingeladener Vortrag
- nein (6)
Die metallischen Verunreinigungen in Metallen lassen sich mittels hochauflösender Massenspektrometer relativ einfach ermitteln. Die Glimmentladungs-Massenspektrometrie (GD-MS) stellt hierfür eine schnelle Multielementmethode dar. Aufgrund ihrer höheren Anregungs- und Ionisationsenergien ist die Bestimmung von Nichtmetallen eine weit größere Herausforderung. Außerdem fehlt es an für die direkte Feststofftechnik notwendigen Kalibrierstandards z.B. in Form zertifizierter Referenzmaterialien. Für die quantitative Bestimmung von Verunreinigungen wurden mit Standards dotierte Pulverpresslinge und dotierte, gesinterte Materialien auf ihre Eignung als Kalibrierstandards für die GD-MS untersucht. Dabei kamen unterschiedliche Plasmabedingungen (gepulster/ kontinuierlicher Betrieb; verschiedene Plasmagase) zum Einsatz. Ein Überblick über analytische Kenngrößen und Grenzen der verwendeten Kalibrierstrategien wird gegeben. Zur Validierung des Verfahrens wurde die hochauflösende Continuum Source Absorptionsspektrometrie (HR-CS-MAAS) verwendet. Die analytische Nutzung der Molekül-absorptionsspektrometrie zur Bestimmung von Halogenen basiert auf der Bildung insitu-generierter zweiatomiger Moleküle (AlCl, GaF). Die entstehenden Molekülspektren werden im Echelle-Spektrometer aufgespalten und mittels CCD-Array detektiert, was eine sehr empfindliche Messung und präzise Quantifizierung ermöglicht.
Die metallischen Verunreinigungen in Metallen lassen sich mittels hochauflösender Massenspektrometer relativ einfach ermitteln. Die Glimmentladungs-Massenspektrometrie (GD-MS) stellt hierfür eine schnelle Multielementmethode dar. Aufgrund ihrer höheren Anregungs- und Ionisationsenergien ist die Bestimmung von Nichtmetallen eine weit größere Herausforderung. Außerdem fehlt es an für die direkte Feststofftechnik notwendigen Kalibrierstandards z.B. in Form zertifizierter Referenzmaterialien. Für die quantitative Bestimmung von Verunreinigungen wurden mit Standards dotierte Pulverpresslinge und dotierte, gesinterte Materialien auf ihre Eignung als Kalibrierstandards für die GD-MS untersucht. Dabei kamen unterschiedliche Plasmabedingungen (gepulster/ kontinuierlicher Betrieb; verschiedene Plasmagase) zum Einsatz. Ein Überblick über analytische Kenngrößen und Grenzen der verwendeten Kalibrierstrategien wird gegeben. Zur Validierung des Verfahrens wurde die hochauflösende Continuum Source Absorptionsspektrometrie (HR-CS-MAAS) verwendet. Die analytische Nutzung der Molekül-absorptionsspektrometrie zur Bestimmung von Halogenen basiert auf der Bildung insitu-generierter zweiatomiger Moleküle (AlCl, GaF). Die entstehenden Molekülspektren werden im Echelle-Spektrometer aufgespalten und mittels CCD-Array detektiert, was eine sehr empfindliche Messung und präzise Quantifizierung ermöglicht.
Vortrag zur Bestimmung von Nichtmetallen in Carbiden halten.
Hierbei geht es um die Bestimmung von C, O und N in Vanadiumcarbid, Wolframcarbid und Niobcarbidmaterialien, einen hierzu durchgeführten Ringversuch mit Beteiligung der Kollegen des AK Sonderwerkstoffe und den Vergleich von Verfahrenskenngrößen.
Mixed copper and titanium hydride powder was hot-pressed and characterized by Carrier Gas Hot Extraction, XRay Diffraction, Thermal Gravimetric Analysis coupled with Mass Spectrometry, and Scanning Electron Microscopy.
The hot-pressed and five conventional samples were applied for calibration of hydrogen in Glow Discharge Optical Emission and Mass Spectrometry. Up to the introduction of 15 ng/s hydrogen the Emission yield model is useful in Glow Discharge Optical Emission Spectrometry. A correlation between saturation and even reversal of the emission yield of the spectral lines H121, H486 and H656 and low sputtering rates was found. Hydrogen effects exist for the spectral lines of Cu(II) 219 and Ti(I) 399. In Glow Discharge Mass Spectrometry, a linear dependency of the 1H ion current on the sputtered mass per time exists over the total range of hydrogen content investigated. Hydrogen effects also exist for the sensitivity of 48Ti and 63Cu. The sputtering rate of two-phase materials depends linearly on the sputtered mass per time of one phase, which allows the sputtering rate of two-phase materials with known composition to be predicted.
A candidate material for the use as primary standard for nickel determination was characterized with respect to total purity. For element determination a pure material can serve as primary standard. However, real world materials are never absolutely pure, hence the total purity of such materials need to be determined experimentally. A reasonable target uncertainty for the purity statement is 10-4 relative. Usually, the purer the material, the easier it is to achieve this target uncertainty. There are two basic ways in order to be able to establish a total purity statement. One is to determine the main component of a high purity material by a direct method such as coulometry, gravimetry or titrimetry. However, these methods are not selective enough for one element and therefore require certain efforts to analyse the material with respect to impurities with interfering analytes. Moreover, to reach the defined target uncertainty is not easy or often impossible to achieve. The second approach is to determine the sum of all possible impurities (as mass fraction) and to subtract it from the ideal purity of 100 % (1 kg/kg). In principle all impurities (all elements not being the matrix element), metals and non-metals must be considered. In this work both approaches to determine the total purity of the nickel material were followed and compared.
The primary (solid) standards are usually used to prepare primary calibration solutions to which secondary and lower order calibration solutions are linked.
The analytical potential of a nanosecond laser ablation inductively coupled plasma mass spectrometer (ns-LA-ICP-SFMS) system, equipped with an ultra-fast wash-out ablation chamber, is critically investigated for fast and highly spatially resolved (∼μm) qualitative elemental distribution within single cells. Initially, a low surface roughness (< 10 nm) thin In–SnO2 layer (total coating thickness ∼200 nm) deposited on glass is employed to investigate the size, morphology and overlapping of laser-induced craters obtained at different laser repetition rates, making use of Atomic Force Microscopy (AFM). Conical craters with a surface diameter of about 2 µm and depths of about 100 nm were measured after a single laser shot. Furthermore, the influence of the sampling distance (i.e. distance between the sample surface and the inner sniffer of the ablation chamber) on the LA-ICP-MS ion signal wash-out time is evaluated. A significant decrease of the transient 120Sn+ ion signal is noticed after slight variations (±200 μm) around the optimum sampling position. Ultra-fast wash-outs (< 10 ms) are achieved reducing the aerosol mixing from consecutive laser shots even when operating the laser at high repetition rates (25 – 100 Hz). Fast and highly spatially resolved images of elemental distribution within mouse embryonic fibroblast cells (NIH/3T3 fibroblast cells) and human cervical carcinoma cells (HeLa cells), incubated with gold nanoparticles (Au NPs) and Cd-based quantum dots (QDs), respectively, are determined at the optimized operating conditions. Elemental distribution of Au and Cd in single cells is achieved using a high scanning speed (50 µm/s) and high repetition rate (100 Hz). The results obtained for the distribution of fluorescent Cd-based QDs within the HeLa cells are in good agreement with those obtained by confocal microscopy. The size, morphology and overlapping of laser-induced craters in the fixed cells are also investigated using AFM, observing conical craters with a surface diameter of about 2.5 µm and depths of about 800 nm after a single laser shot.
Messergebnisse in der chemischen Analyse müssen vergleichbar sein. Dies wird durch die metrologische Rückführbarkeit (traceability) auf SI realisiert. In der Chemie dienen Reinststoffe als Primärnormale, deren Reinheit mit einer Unsicherheit von < 0.01% ermittelt werden soll. Ein eleganter Weg, die Reinheit eines realen Materials mit hoher Präzision zu bestimmen, ist, alle Verunreinigungen zu messen, diese aufzusummieren und von der idealen Reinheit von 100 Prozent abzuziehen. Die metallischen Verunreinigungen in Metallen lassen sich mittels hochauflösender Massenspektrometer ermitteln. Eine weit größere Herausforderung ist die Bestimmung von Nichtmetallen wie Sauerstoff, Wasserstoff und Stickstoff im Metall, zumal diese auch oft die Hauptverunreinigung darstellen. Für die quantitative Bestimmung von Verunreinigungen wurden mit Standards dotierte Pulverpresslinge und mit H, O und N dotierte, gesinterte Materialien auf ihre Eignung als Kalibrierstandards für die GD-OES und GD-MS untersucht. Dabei kamen unterschiedliche Plasmabedingungen (pulsed/ continuous mode; verschiedene Plasmagase) zum Einsatz. Ein Überblick über analytische Kenngrößen und Grenzen der verwendeten Kalibrierstrategien wird gegeben.
The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry.
For the first time, an international comparison was conducted on the determination of the purity of a high purity element. Participants were free to choose any analytical approach appropriate for their institute’s applications and services. The material tested was a high purity zinc, which had earlier been assessed for homogeneity and previously used in CCQM-K72 for the determination of six defined metallic impurities. Either a direct metal assay of the Zn mass fraction was undertaken by EDTA titrimetry, or an indirect approach was used wherein all impurities, or at least the major ones, were determined and their sum subtracted from ideal purity of 100 %, or 1 kg/kg. Impurity assessment techniques included glow discharge mass spectrometry, inductively coupled plasma mass spectrometry and carrier gas hot extraction/combustion analysis. Up to 91 elemental impurities covering metals, non-metals and semi-metals/metalloids were quantified. Due to the lack of internal experience or experimental capabilities, some participants contracted external laboratories for specific analytical tasks, mainly for the analysis of non-metals. The reported purity, expressed as zinc mass fraction in the high purity zinc material, showed excellent agreement for all participants, with a relative standard deviation of 0.011 %. The calculated reference value, w(Zn) = 0.999 873 kg/kg, was assigned an asymmetric combined uncertainty of + 0.000025 kg/kg and – 0.000028 kg/kg. Comparability amongst participating metrology institutes is thus demonstrated for the purity determination of high purity metals which have no particular difficulties with their decomposition / dissolution process when solution-based analytical methods are used, or which do not have specific difficulties when direct analysis approaches are used. Nevertheless, further development is required in terms of uncertainty assessment, quantification of non-metals and the determination of purity of less pure elements and/or for those elements suffering difficulties with the decomposition process.
High spatially resolved quantitative bioimaging of CdSe/ZnS Quantum Dots uptake in two kinds of cells is investigated combining laser ablation inductively coupled plasma mass spectrometry and the spatially resolved analysis of dried pL-droplets from a solution with a known concentration of Quantum Dots. Single cells and dried pL-droplets are morphologically characterized by Atomic Force Microscopy. A number concentration of CdSe/ZnS QDs between 3.5 104 and 48 104 is estimated to be uptaken by several selected single cells, after being incubated in the presence of a QDs suspension added to a standard cell culture medium. Mono-elemental bioimaging at subcellular resolution seems to show a higher number concentration of the CdSe/ZnS QDs in the cytosol around the cell nucleus.